首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Koshima H  Onishi H 《Talanta》1980,27(10):795-799
Nanogram amounts of mercury(II) and methylmercury in artificial sea-water containing mineral acids as preserving reagents were shown to be collected quantitatively with activated carbon. Mercury concentrated on activated carbon was determined directly by combustion, trapping on gold and electrothermal atomic-absorption spectrophotometry. The activated carbon was purified by heating at 350 degrees for 2 hr. Sulphuric acid and hydrochloric acid were purified by treatment with activated carbon. Interference from iodide was eliminated by using a carbonate buffer wash before the atomic-absorption measurement. Less than 4 ng of mercury in 200-300 ml of artificial sea-water, whether acidified or not (with sulphuric, hydrochloric or nitric acid), was satisfactorily collected with 100 mg of activated carbon. Mercury was also collected quantitatively after oxidative treatment of artificial sea-water.  相似文献   

2.
A fully automated system for the direct determination of methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) at the ng/L level is described. It is based on solid phase extraction preconcentration incorporated in a flow injection (FI) system, high performance liquid chromatography (HPLC) separation, reduction combined with thermolysis and determination by cold vapour atomic absorption spectrometry (CVAAS). For preconcentration a microcolumn of bonded silica with octadecyl functional groups (C18 reversed phase material) was used as a sorbent for the mercury complexes formed on-line with ammonium pyrrolidine dithiocarbamate. Retained mercury species are eluted with a methanol-acetonitrile-water mixture and subjected to separation on an octadecylsilane (ODS) column before determination by CVAAS. The sensitivity of organo-mercury determination could be improved by using NaBH4 as a reductant combined with a thermolysis step. In order to perform on-line measurements the preconcentration microcolumn was mounted in a pressure-tight casing. Limits of detection for MeHg, EtHg, PhHg and Hg(II) employing a sample volume of 58.5 mL were 9, 6, 10 and 5 ng/L, respectively. The relative standard deviation (RSD) calculated from 9 repeated measurements was found to be 3.6%, 5.5%, 10.4% and 7.6% for MeHg, EtHg, PhHg and Hg(II), respectively. Finally, the application of this method for speciation of mercury in fish and human urine is described.  相似文献   

3.
Sulphur trioxide is directly titrated in fuming sulphuric acid (oleum) with water in the form of diluted sulphuric acid. A nickel electrode is used and a newly developed mercury/mercuric(I)-sulphate reference electrode. The heat of hydration must be hold under control by means of an ice bath and by variation of the speed of titration.  相似文献   

4.
Bhatty MK  Uden PC 《Talanta》1971,18(8):799-805
A method, based on the passivity of mercury(II) cyanide in dilute sulphuric acid and its reaction with hydrochloric acid to produce hydrogen cyanide, has been developed for the determination of small amounts of chloride. Hydrogen cyanide, distilled from a mercury(II) cyanide-halide-dilute sulphuric acid system is found by iodometric measurement to be directly proportional to the amount of chloride or bromide and of hydrogen ion in acids such as sulphuric acid. A linear correlation also holds for iodide but the stoichiometry is different, the titration values being about three times larger than expected. By conversion of the cyanide into a dye by means of the pyridine-pyrazolone reagent, 0.014-0.43 mug ml chloride concentrations have been determined. The method is also applicable to bromide and sulphuric acid in small amounts but not to fluoride and iodide. Results are reproducible to within +/-2%.  相似文献   

5.
Hafez MA  Kenawy IM  Akl MA  Lashein RR 《Talanta》2001,53(4):749-760
The use of chemically modified chloromethylated polystyrene-PAN, CMPS-PAN (ion-exchanger) for the preconcentration and separation of total mercury after digestion in preparation for determination by cold vapour atomic absorption spectrometry (CVAAS) was described. The effects on the percentage of recovered mercury by mass change of ion-exchanger, stirring time, pH of the solution samples and eluent concentration were studied. The distribution coefficient K(d) is 10(6.6) ml g(-1). The interfering effects of some foreign ions were described. The metal complex formed between CMPS-PAN ion-exchanger and mercury was characterized by IR spectroscopy, pH-metric titration and thermal analysis. The method is simple and rapidly applicable for the determination of total mercury (ng ml(-1)) in natural water, milk and urine.  相似文献   

6.
A fully automated system for the direct determination of methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) at the ng/L level is described. It is based on solid phase extraction preconcentration incorporated in a flow injection (FI) system, high performance liquid chromatography (HPLC) separation, reduction combined with thermolysis and determination by cold vapour atomic absorption spectrometry (CVAAS). For preconcentration a microcolumn of bonded silica with octadecyl functional groups (C18 reversed phase material) was used as a sorbent for the mercury complexes formed on-line with ammonium pyrrolidine dithiocarbamate. Retained mercury species are eluted with a methanol-acetonitrile-water mixture and subjected to separation on an octadecylsilane (ODS) column before determination by CVAAS. The sensitivity of organo-mercury determination could be improved by using NaBH4 as a reductant combined with a thermolysis step. In order to perform on-line measurements the preconcentration microcolumn was mounted in a pressure-tight casing. Limits of detection for MeHg, EtHg, PhHg and Hg(II) employing a sample volume of 58.5 mL were 9, 6, 10 and 5 ng/L, respectively. The relative standard deviation (RSD) calculated from 9 repeated measurements was found to be 3.6%, 5.5%, 10.4% and 7.6% for MeHg, EtHg, PhHg and Hg(II), respectively. Finally, the application of this method for speciation of mercury in fish and human urine is described. Received: 10 March 1997 / Revised: 29 January 1998 / Accepted: 5 February 1998  相似文献   

7.
An isocratic high-performance liquid chromatographic method has been developed to allow the simple and rapid determination of both vinburnine (I) and its main metabolite, 6-hydroxyvinburnine (II), in heparinized human plasma (0.5 ml). Compounds I and II and p-chlorodisopyramide (internal standard) were first extracted with alkalinized ethyl acetate and then with sulphuric acid. Separation was achieved on a reversed-phase muBondapak C18 column with a mobile phase of acetonitrile-water-0.1 M heptanesulphonate in acetic acid and with detection at 254 nm. Each run required 20 min. The within-day coefficients of variation for identical samples (20 ng/ml) were 7 and 6% and between-day coefficients of variation 8 and 26% for I and II, respectively. The detection limit was 5 ng/ml (normal therapeutic concentration, 10-300 ng/ml). The application of the method to drug monitoring was compared to that of a thin-layer chromatographic procedure.  相似文献   

8.
A comparative study of three mercury chelate forming reagents [diethyldithiocarbamate, pyrrolidin-1-yldithioformate and diphenylthiocarbazone (dithizone)] has been carried out for the preconcentration of ultratrace amounts of inorganic mercury and methylmercury in silica C(18) minicolumns as the solid sorbent. Sample flow injection in-line sorbent extraction was coupled with continuous cold vapour atomic absorption spectrometry (CVAAS) for detection. Results showed the superiority of the carbamate type reagents over the dithizone for the on-line formation and preconcentration of the corresponding mercury chelates. Using diethyldithiocarbamate (DDC) as reagent, aqueous sample volumes of 100 ml can be preconcentrated with 100% efficiency for both inorganic mercury and methylmercury. Quantitative release of the retained DDC chelates was obtained for volumes of eluent (ethanol) of 50 microl. Following the proposed procedure, detection limits of 16 ng/l. of mercury were achieved for sample volumes of 25 ml. The relative standard deviation was +/- 3.4% at 0.5 microg/l. Hg(II) levels. The method has been successfully applied to the determination of low levels of mercury in sea-water.  相似文献   

9.
A sensitive method was proposed and optimized for the determination of total mercury in fish tissue by using wet digestion, followed by cold vapor atomic absorption spectrometry (CVAAS) at the main resonance line of mercury (184.9 nm). The measurements were made using a new type of a non-dispersive mercury minianalyzer. This instrument was initially designed and built for atmospheric mercury-vapor detection. For determining mercury in aqueous samples, the minianalyzer was linked with a mercury/hydride system, Perkin Elmer Model MHS-10. To check the method, the analyzed samples were spiked with a standard solution of mercury. The recoveries of mercury spiked to wet fish tissue were >90% for 0.5 - 0.8 g samples. The results showed a better sensitivity (about 2.5 times higher) when using the mercury absorption line at 184.9 nm compared with the sensitivity obtained by conventional CVAAS at 253.7 nm.  相似文献   

10.
Sample preparation methods for non-separation cold vapor atomic absorption spectrometry (CVAAS) sequential inorganic mercury speciation in biological certified reference materials (CRMs) were investigated. The methylmercury concentration was calculated as the difference between total and inorganic mercury. Microwave-assisted decomposition method, and three ultrasonic extraction procedures based on acid leaching with HCl and HCOOH and solubilization with TMAH were employed as sample preparation methods. The replacement of a sample decomposition procedure by extraction prior to analysis by CVAAS, as well as the aspect of speciation analysis is discussed. The limits of detection in the sample were determined as 50 and 10 ng L−1 for inorganic and total mercury, which corresponds to absolute detection limits of 40 and 8 ng g−1 for inorganic and total mercury, respectively. The results were in good agreement with the 95% confidence level t-test of the certified values for total and inorganic mercury in the reference materials investigated. From the analysis of the CRMs, it was evident that the difference between the total and inorganic mercury concentrations agrees with the methylmercury concentration. The relative standard deviation was better than 11% for most of the samples.   相似文献   

11.
A novel and simple microprecipitation method was developed for the preconcentration of ultra-trace quantities of inorganic and methyl mercury species (iHg and MeHg) prior to their determination by cold vapour atomic absorption spectrometry (CVAAS). This method is based on the formation of anionic complexes of Hg2+ with KI followed by ion-associate complex with cetyltrimethyl ammonium bromide (CTAB) that forms a fluffy precipitate in perchloric acid medium. As a result, a fluffy coagulated mass separates and collects at the top of the liquid surface with clear phase separation without need of cooling or heating or centrifugation. The ion-association complex of iHg was then extracted into surfactant-rich phase (top layer) of CTAB-perchlorate precipitate while the uncomplexed MeHg remained in the aqueous phase (bottom layer). This condition also facilitates the removal of aqueous phase by simply draining out. The fluffy mass formed was dissolved in a mixture of HNO3 and HCl which was subsequently treated with chloroform to separate the surfactant from the mixture. Then the aqueous phase containing the preconcentrated iHg was analysed for mercury by CVAAS. Key factors such as sample pH, concentration of KI and CTAB that affect the performance of the proposed microprecipitation method were thoroughly investigated. For the determination of total mercury, another fresh aliquot of water was initially adjusted to pH ~ 3.5 with perchloric acid and subjected to oxidation by using modified UV-irradiation set-up and then taken through the microprecipitation procedure. This method allows speciation of mercury with a preconcentration factor of 200 and the limits of detection (LOD) of mercury obtained for CVAAS in conjunction with the present preconcentration method was found to be 2.4 ng L?1. Average recoveries obtained with the proposed approach were found to be in the range of 96–104% with RSD values < 5%. The interfering effects of various cations and anions were also investigated. The method was successfully applied for the determination of ultra-trace quantities of mercury species in real samples such as bottled water, tap water, lake water and ground waters.  相似文献   

12.
A highly selective spectrofluorometric method for the determination of total mercury (Hg) in waste waters is described. Fluorescence quenching of rhodamine B with Hg(II) in the presence of iodide, after a concentration step, is the basis of this sensitive method. All forms of mercury, including organic compounds, are pre-oxidized to ionic mercury by acidic potassium permanganate. The final and complete oxidation is achieved by adding potassium persulphate and heating. Hg(II) was reduced by tin(II) chloride and Hg vapour driven by an air stream into an absorption solution containing potassium permanganate and sulphuric acid, using a closed, recirculating air stream. In this solution fluorescence quenching of rhodamine B at an excitation wavelength of 485 nm and emission wavelength of 586 nm was measured. The recoveries were done by adding 3.0 g Hg/100 ml to each sample before the digestion. It was indicated that the recoveries for determining mercury in waste waters were 98.3%–102.7%. The method gives reliable results down to a concentration of 10 ng Hg/ml waste water.  相似文献   

13.
Kobayashi S  Nakahara T  Musha S 《Talanta》1979,26(10):951-957
A method has been developed for the determination of bismuth by generation of its gaseous hydride and introduction of the hydride into a premixed argon (entrained air)-hydrogen flame, the atomic-fluorescence lines from which are all detected by use of a non-dispersive system. The detection limit is 5 pg/ml, or 0.1 ng of bismuth, but the reagent blank found in a 20-ml sample volume was approximately 2 ng of bismuth. Analytical working curves obtained by measuring peak-heights and integrated peak-areas of the signals are linear over a range of about four orders of magnitude from the detection limit. Perchloric, phosphoric and sulphuric acids up to 2.0M concentration give no interference, but nitric acid gives slight depression of the signal. The presence of silver, gold, nickel, palladium, platinum, selenium and tellurium in 1000-fold ratio to bismuth causes pronounced depression of the signal, whereas mercury and tin slightly enhance the atomic-fluorescence signal. The method has been applied to the determination of bismuth in aluminium-base alloys and sulphide ores with use of the standard additions method. The results are in good agreement with those obtained by flame atomic-absorption spectrometry and optical emission spectrometry with an inductively coupled plasma.  相似文献   

14.
Kiekens P  Temmerman E  Verbeek F 《Talanta》1984,31(9):693-701
The reduction of Hg(II) at a glassy-carbon electrode in various electrolytes has been studied by rotating ring-disc voltammetry. Reduction proceeds directly to metallic mercury in a single 2-electron step. However, at the foot of the wave, and only during the first reduction sweep after pretreatment of the electrode surface, a small amount of Hg(I) species is detected at the ring. The appearance of an Hg(I) intermediate is most pronounced in sulphuric acid solution. The reduction of Hg(II) is found to proceed irreversibly and to be of first order. At sufficiently negative potentials the reduction is convective-diffusion controlled. Stripping voltammetric experiments indicate that the dissolution of mercury gives Hg(II) in complexing electrolytes. In non-complexing electrolytes the initially formed Hg(II) reacts with mercury atoms on the electrode surface to give Hg(I). During electrodissolution, two stripping peaks may be observed as a result of underpotential adsorption of mercury on glassy carbon. The difference in peak potential between the adsorption (mono) layer peak and the bulk mercury peak has been related to the difference in work functions of the deposit (mercury) and substrate (carbon). A rotating glassy-carbon electrode has been used for the anodic stripping determination of mercury. When an appropriate amount of a cation such as cadmium(II) or copper(II) is added to the test solution, mercury down to 2 x 10(-9)M (0.4 ng ml ) can be determined in acidified thiocyanate electrolyte with a relative standard deviation of about 22%.  相似文献   

15.
A non instrumental method for the semiquantitative determination of mercury in fish is described. The sample is acid digested and the mercury vapor released after chemical reduction with SnCl2. The mercury vapor is then collected on a detecting paper covered with an emulsion of Cu2I2, 3% carboxymethylcellulose and MgCl2 as moistener agent. The colored Cu2[HgI4] complex is formed and the color intensity is proportional to the mercury concentration in the original sample. Parameters such as sample mass/digestion solution volume ratio, emulsion composition, paper covering technique, carrier gas flow were investigated. Comparative studies using CVAAS and digital color analysis after scanning the papers confirmed the applicability of the method to real samples.  相似文献   

16.
The purpose of the study was to optimise analytical methods for determination of the chemical speciation of mercury in studies of protective mechanisms of selenium. Optimisation of the methods was performed using CRM DOLT-2 (Dogfish liver), both in its original form and after separation of various fractions. The sample was homogenised with 10 mM Tris-HCl buffer (pH 7.6) and ultracentrifuged. The soluble phase obtained was applied to a size exclusion chromatography column (Sephadex G-75 column) for separation of various protein fractions. Total mercury (total Hg), monomethyl mercury (MeHg) and selenium (Se) were determined in whole dogfish liver tissue and its soluble and insoluble phases (pellet). Different approaches for determination of total Hg and MeHg were compared. Simultaneous determination of MeHg and inorganic mercury (Hg2+) was based on alkaline dissolution and/or acid leaching, followed by ethylation, room temperature precollection, isothermal gas chromatography (GC), pyrolysis and detection with cold vapour atomic fluorescence spectrometry (CVAFS). The sum of MeHg and Hg2+ was compared to total Hg results obtained by acid digestion and CVAAS detection. The accuracy of MeHg determination was checked by its determination using acid leaching at room temperature, solvent extraction, back extraction into Milli-Q water, ethylation, GC and CVAFS detection. For the insoluble phase it is recommended to use solvent extraction for MeHg and acid digestion CVAAS for total Hg. For determination of MeHg and Hg2+ in the lyophilised sample and water soluble fractions containing low concentrations of mercury species, the simultaneous measurement of MeHg and Hg2+ after alkaline dissolution is the most appropriate method.  相似文献   

17.
《Analytical letters》2012,45(4):775-784
Abstract

A spectrofluorimetric method for the determination of ultratrace amounts of lead and mercury is described based on the sequential extraction of the ternary ion-association complexes formed between the cation, a cryptand as the ligand and eosin as counter ion. A linear working range from the detection limit (9 ng/ml) to 250 ng/ml of lead and 12 ng/ml of mercury was obtained.

The relative standarddeviation was 3.5 % – 2.1 %. We propose that this method could be used routinely to control lead and mercury simultaneous.  相似文献   

18.
A novel crosslinked chitosan (CCTS) has been synthesized by the reaction of water-soluble chitosan with epoxy chloropropane. In the presence of the chelating EDTA and in the pH range between 4–10, CCTS selectively adsorbed trace inorganic Hg in water samples with enrichment factors of 100. Inorganic Hg could be directly reduced using KBH4 without preceding elution and determined by CVAAS. Accordingly, the total mercury could be determined after all species of mercury in water samples were transformed into Hg2+. The detection limit (3σ) for mercury was 12 ng L–1 and the relative standard deviation less than 5% at the 50 ng L–1 level. Beer’s law was obeyed over the range 30–400 ng L–1 of mercury and the preconcentration method was applied to environmental water samples with the recoveries between 92–96%.  相似文献   

19.
建立了一种水中痕量汞的测定方法。通过活性炭定量吸附水中痕量汞,采用电热塞曼原子吸收光谱法测定活性炭富集的汞。与目前水中总汞测定方法相比,本方法避免了消解等步骤,减少了汞污染和汞损失,操作更加简单。考察了活性炭粒度、酸处理方法、酸介质和富集时间对富集效率的影响,以及热解温度和干扰离子对方法测定结果的影响。通过空白活性炭加标、空白溶液加标和环境水样加标3种方法制作标准曲线,三者的相关系数达0.9999,经统计检验,3条标准曲线的斜率无差异,表明了在此实验条件下环境水样中的共存物不干扰汞的测定,同时也表明可直接用空白活性炭加标的方法进行标准曲线的绘制。采用本方法对含5和50 ng/L汞的水样进行测定,其相对标准偏差分别为7.2%和4.2%(n=11)。本方法测定下限达到1.2 ng/L。地表水和自来水样中添加10 ng/L汞的加标回收率在92.0%~103.0%之间。用 ICP-MS作对照,二者分析结果相符合,相对误差在2.9%~ 3.4%之间,表明本方法准确可靠、精密度好。  相似文献   

20.
Cold Vapour Atomic Absorption Spectrometry (CVAAS) and Gas-Liquid Chromatography (GLC) have been used for determination and speciation of mercury. Total mercury, methylmercury, ethylmercury and phenylmercury concentrations in urine samples taken from students and staff of a dental work-place were investigated. Air samples were also analyzed. Detection limits, as three times the standard deviation, and in units of ng analyte per ml urine were found to be 1.7, 12, 2.4 and 21 for total mercury, methylmercury chloride, ethylmercury chloride and phenylmercury chloride, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号