首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary A rapid and accurate LC method is described for simultaneous determination of pseudoephedrine hydrochloride (PSE), acetaminophen (AMP), dextromethorphen hydrobromide (DEX), and diphenhydramine hydrochloride (DPH) in a compound formulation. Chromatographic separation of the four drugs was achieved on a Hypersil CN column (150 mm × 4.6 mm, 5 m particle) by use of a mobile phase comprising a mixture of 3 mM ion-pairing solution, 2% aqueous triethylamine solution, and 2 M phosphoric acid, 68:48:88 (v/v), pH 3.0, delivered at 1.0 mL min–1. Compounds were detected at 215 nm and the run time was less than 10 min. The linearity, accuracy, and precision of the method were found to be acceptable over the concentration ranges 6.1–36.4 g mL–1 for PSE, 65.0–390.0 g mL–1 for AMP, 3.1–18.6 g mL–1 for DEX, and 5.0–30.0 g mL–1 for DPH.  相似文献   

2.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

3.
The aim of the present study was to develop a sensitive method to measure dextromethorphan and dextrorphan in urine by HPLC to support pharmacogenetic studies in ethnic groups. Linearity was assessed in the range: 0.015–10 g mL–1 for dextromethorphan and 1-10 g mL–1 for dextrorphan. Inter and intra-day coefficients of variation were < 10%. Limits of detection and quantitation were 0.003 g mL–1 and 0.015 g mL–1 for dextromethorphan and 0.24 g mL–1 and 1.0 g mL–1 for dextrorphan, respectively. The method is reliable in helping determine the phenotype of Mexican ethnic groups using model drugs such as dextromethorphan.  相似文献   

4.
Pfeffer  M.  Walenciak-Reddel  E. 《Chromatographia》1994,38(7-8):479-484
Summary A high-performance liquid chromatographic method is discribed for the determination of 6-amino-2,2-dimethyl-1,3-dioxepan-5-ol using Spherisorb ODS II stationary phase and mobile phase 30:70 (v/v) methanol: aqueous 1-octane sulfonic acid. Detection was fluorimetric following postcolumn derivatization with o-phthaladehyde/2-mercaptoethanol. The procedure was applied to the analysis of aqueous solutions and microcrystalline suspensions in liquid paraffin, prepared for investigation of the toxicological profile. The method was validated for selectivity, linearity of detector response, repeatability, limit of detection and quantitation. The HPLC method was selective. The instrumental limit of detection was 0.5 ng per injection (0.05 g mL–1). The method detection limits were 0.5 g mL–1 aqueous solution and 5 g mL–1 liquid paraffin suspension, the quantitation limit 0.05 mg mL–1 aqueous solution and 1.0 mg mL–1 liquid paraffin. Linearity was within 0.94–47.1 g mL–1. Intra-assay accuracy accounted for 99–100% in the range 0.05–226 mg mL–1 aqueous solution, intra-assay precision for 2% (C.V.). For microcrystalline liquid paraffin suspensions with 1 and 250 mg mL–1 99 and 109% was found for intra-assay accuracy. Intra-assay precision was 5% (C.V.). Reliable results over a wide concentration range can be obtained. The procedure is considered valid for determination of the analyte in aqueous solution or microcrystalline paraffin oil suspensions.  相似文献   

5.
A novel method for the direct determination of the aminoglycoside tobramycin was developed and validated based on reversed-phase high-performance liquid chromatography (RP-HPLC) with evaporative light scattering detector (ELSD). Using a Waters ODS-2 C18 Spherisorb column with an evaporation temperature of 45°C and nitrogen pressure of 3.5 bar, the selected mobile phase consisted of water/acetonitrile 55:45 containing 1.5 mL L–1 HFBA (11.6 mM) in an isocratic mode at a rate of 1.0 mL min–1. Tobramycins retention time was 4.3 min with an asymmetry factor of 1.7. A logarithmic calibration curve was obtained from 1 to 38 g mL–1 (r > 0.9998). LOD was 0.3 g mL–1; within-day %RSD was 1.0 (n = 3, 4.7 g mL–1) and between-day %RSD was 1.1 (3 days within a week). The developed method was applied to the determination of tobramycin in a pharmaceutical crude substance and formulations (eye drops and ointments). Dilution experiments revealed the absence of interference from excipients (no constant and proportional errors); recovery from spiked samples was 99–103% with %RSD < 2.2 (n = 3×3). The developed HPLC/ELSD method was also found to be applicable in the determination of tobramycin in human plasma (0.6–12.5 g mL–1) and urine (1.5–12.5 g mL–1) after solid-phase extraction using carboxylate cartridges followed by solvent evaporation (×2 preconcentration). A mean recovery of 86% for plasma and 91% for urine was obtained.  相似文献   

6.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

7.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

8.
A rapid and accurate HPLC method has been developed for simultaneous determination of pioglitazone and glimepiride. Chromatographic separation of the two pharmaceuticals was performed on a Cosmosil C18 column (150 mm × 4.6 mm, 5 m) with a 45:35:20 (v/v) mixture of 0.01 m triammonium citrate (pH adjusted to 6.95 with orthophosphoric acid), acetonitrile, and methanol as mobile phase, at a flow rate of 1.0 mL min–1, and detection at 228 nm. Separation was complete in less than 10 min. The method was validated for linearity, accuracy, precision, limit of quantitation, and robustness [1, 2]. Linearity, accuracy, and precision were found to be acceptable over the ranges 2.50–30.00 g mL–1 for pioglitazone and 0.10–10.00 g mL–1 for glimepiride.  相似文献   

9.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

10.
An isocratic liquid chromatographic method for determination of acetaminophen (AMP), caffeine (CAF), chlorphenamine maleate (CPM) and guaiacol glyceryl ether (GGE) in a compound cold formulation is described. Separation and quantitation were achieved on a Diamonsil C18 column using a binary mixture of methanol and 1.5% aqueous acetic acid (55: 45, v/v, pH 3.6) as mobile phase delivered at 0.4 mL min–1. Single wavelength detection was at 220 nm for all four drugs and the run time was < 10 min. The linearity, accuracy and precision of the method were found to be acceptable over the concentration ranges: 16.0–127.8 g mL–1 for AMP, 6.0–48.2 g mL–1 for CAF, 5.0–40.0 g mL–1 for CPM and 10.1–80.6 g mL–1 for GGE.  相似文献   

11.
A method has been developed for photometric detection of cyclodextrins (CD) in liquid chromatography using iodine (I2) generated electrochemically in-situ. Iodide ion in the mobile phase was electrochemically oxidized to I2 which was subsequently reacted with I, in an electrochemical flow cell, forming I3. The absorbance of I3 was found to be greatly enhanced when CD were present in the mobile phase. The absorbance enhancement was caused by the change in the mole fraction of I3, because of the inclusion reaction of I3 with CD. On the basis of this phenomenon, CD were detected by means of a photodiode-array UV–visible detector positioned downstream of the electrochemical flow cell. The signals were found to be linearly dependent on CD concentration. Because the formation constants of I3 with CD decrease in the order -CD>-CD>-CD, -CD was most detectable by the method. Detection limits were 1.0 mol L–1 for -CD, 65 mol L–1 for monoG1--CD, 100 mol L–1 for -CD, and 200 mol L–1 for -CD.  相似文献   

12.
Summary The hydrocarbon composition of the particle and gas phases in the urban atmosphere has been studied by filtration and parallel adsorption on active charcoal and polyurethane foam (PUF). Gas chromatography (GC) and GC coupled to mass spectrometry (GC-MS) have been used for the analysis of the organic matter extracts obtained with each system. In the case of the particle and PUF samples these extracts were fractionated into aliphatic and aromatic compounds. This approach has allowed to identify up to 247 hydrocarbon molecules showing that C0–C5 alkylbenzenes are the major compounds in the charcoal extracts whereas C14–C23 n-alkanes, C0–C4 alkylnaphthalenes, C0–C4 alkylbiphenyls and C3–C5 alkylbenzenes are those predominantly found in the PUF materials. The particles essentially contain C17–C38 n-alkanes and parent polycyclic aromatic hydrocarbons (PAH). These qualitative differences are paralleled by a progressive concentration decrease from the more to the less volatile hydrocarbons. Thus, the total charcoal extracts average 80 g/m3, the PUF compounds represent 4 /m3 and the particle hydrocarbons 0.7 g/m3. These latter airborne materials are essentially composed of petrogenic residues 0.6 g/m3 (aliphatic fraction) whereas the pyrolytic PAH only involve 0.08 g/m3.  相似文献   

13.
A method using headspace solid-phase microextraction (HS-SPME) then gas chromatography–mass spectrometry with selected ion monitoring (GC–MS, SIM) has been developed for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in soil and humic materials. Both fungicides were extracted on to a fused-silica fibre coated with 85 m polyacrylate (PA). Response-surface methodology was used to optimise the experimental conditions. For soil samples the linear dynamic range of application was 0.004–1.000 g g–1 for pyrimethanil and 0.013–1.000 g g–1 for kresoxim-methyl. The detection limits were 0.001 g g–1 and 0.004 g g–1 for pyrimethanil and kresoxim-methyl, respectively. HP-SPME–GC–MS analysis was highly reproducible—relative standard deviations (RSD) were between 6.7 and 12.2%. The method was validated by analysis of spiked matrix samples and used to investigate the presence of pyrimethanil and kresoxim-methyl above the detection limits in soil and humic materials.  相似文献   

14.
    
Zusammenfassung 2-Thiobarbitursäure wird zum Nachweis und zur Bestimmung von Fe(III) verwendet. Im Reagensglas kann noch 1 g Fe(III)/ml nachgewiesen werden. Eine größere Empfindlichkeit (0,2 g/ml) wird bei Anwendung eines mit Thiobarbitursäurelösung getränkten Papiers erreicht. Die photometrische Bestimmung ist im Konzentrationsbereich 4–40 g/ml mit einem Fehler von höchstens ±0,5 g möglich.
Summary 2-Thiobarbituric acid is recommended for the detection and determination of trivalent iron. In the test tube 1 g of Fe(III)/ml can be detected, whereas this limit can be reduced to 0.2 g of Fe(III)/ml by use of paper impregnated with the reagent. The photometric determination is possible within the range of 4–40 g of Fe(III)/ml with an error of not more than ±0.5 g.
  相似文献   

15.
New homopolynuclear nickel(II) xanthate complexes with nitrogen donor heterocycles as bridging ligands have been prepared, namely [Ni(Rxa)2(-L)]n and [Ni2(Rxa)4(-L1)], where R=i-Pr,i-Am; xa=OCS2– L=1,2-bis(4- pyridyl)ethane (bpe), 4,4-dithiodipyridyl (dtp), 1,2-bis(4- pyridyl)ethylene (dpe), 4,4-trimethylene-dipyridine (tmd); L1=2,3-bis(2-pyridyl)pyrazine (bpp), 2,4-bis(5,6- diphenyl-1,2,4-triazine-3-yl)pyridine (bdt), or 2,4,6-tris(2- pyridyl)-1,3,5-triazine (tpt). The compounds have been characterized by elemental analyses, i.r. and electronic spectroscopies, magnetochemical and conductivity measurements. The results show that the [Ni(Rxa)2(-L)]n complexes are linear polymers in which the nitrogen heterocycles bridge between the nickel(II) ions, which are coordinated by four sulfur and two nitrogen atoms and have trans-octahedral geometry. The nearly constant values of the effective magnetic moment (3.36–3.34 eff/B) over the 77–295 K temperature range indicate that exchange interactions are lacking among the paramagnetic centres in the linear structure, [Ni(i-Amxa)2(dpe)]n. The variable- temperature magnetic susceptibilities of the [Ni2(i-Prxa)4(bpp)] (3.00–2.95eff/B per Ni atom), [Ni2(i-Prxa)4(bdt)] (2.72–2.63 eff/B per Ni atom), and [Ni2(i-Amxa)4(tpt)] (2.76–1.87 eff/B per Ni atom) were measured down to liquid nitrogen temperature. In the case of binuclear nickel(II) complexes with bdt or tpt, antiferromagnetic coupling between the nickel(II) ions was detected, giving the exchange integral J=–4.0cm–1 and –29.6cm–1, respectively.  相似文献   

16.
The optimum conditions for the extractive spectrophotometric determination of dioxouranium(VI) with hexamethyleneiminecarbodithioate(HMICdt) have been established. Dioxouranium(VI) reacts with this ligand at pH 4.5 to form a yellowish-orange uncharged 12 metal-ligand complex which can be extracted by chloroform. The calibration graph was linear in the range of 1–20 g ml–1 of dioxouranium(VI) at 335 nm. The molar absorptivity of the extracted species is 5.952×103 l mol–1 cm–1 with Sandell's sensitivity of 0.04 g cm–2. The average of 10 determinations of dioxouranium was 49.75 g for the samples containing 50 g of U(VI) and the variation from the mean at 95% confidence limit was 49.75±0.5955.  相似文献   

17.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

18.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

19.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

20.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号