首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
LiMgPO4 (LMP) crystals were grown by micro pulling down technique. Samples were irradiated with different β-particle doses of the 90Sr/90Y source. Thermally and optically stimulated luminescence spectra were measured with the automatic Risø TL/OSL-DA20 reader under the different modes of stimulation. The dose–response dependence, reproducibility, the lowest measurable dose and short-time fading were investigated. TL and OSL dose–response of LiMgPO4 crystals was found to be linear up to around 1 kGy, what makes this material suitable for high dose measurements. Discrepancies between successive measurements did not exceed 10%, regardless of the applied growth parameters. The lowest measurable dose, defined as three standard deviations of the signal of unexposed detector, was determined around 0.5 mGy. About 73% of the initial OSL signal value was measured 24 h after the irradiation. For longer periods of time the level of signal stabilizes so that there was no further loss of signal observed. In case of TL, the level of signal does not stabilize and decreases to 69% within 2 weeks after the irradiation. The obtained results tend to suggest that LiMgPO4 crystals may be considered as promising dosimeters for both personal and high dose dosimetry.  相似文献   

2.
Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment.  相似文献   

3.
This study is focused on energy response of Ge-doped silicon dioxide optical fiber subjected to photon irradiation. The TL responses for photon energies, ranging from 20 keV to 20MeV, were investigated as energy absorbed in the TL materials of Ge-doped silicon dioxide optical fiber. The simulation was performed using Monte Carlo N-particle transport code version 5 (MCNP5). The input parameters included in this study are source information, geometry specification, material information and tallies F6. Comparisons of energy response were done between simulation and previous results of experiments. A flat response can only be seen in the energy range of 200 keV to 10 MeV.  相似文献   

4.
The badge system of personal thermoluminescence (TL) dosimeter for photon fields using LiF:Mg,Cu,Na,Si TL material, which was developed by Korea Atomic Energy Research Institute (KAERI) a few years ago, was developed by taking advantage of its dosimetric properties including energy dependencies. A badge filter system was designed by practical irradiation experiments supported by computational modeling using Monte Carlo simulation. Design properties and dosimetric characteristics such as photon energy response and angular dependence of new TL dosimeter system examined through the irradiation experiments are presented. Based on the experiments for the developed dosimeter, it is demonstrated that the deep dose response of dosimeter provided the value between 0.78 and 1.08, which is within the design limit by ISO standard. This multi-element TL dosimeter badge system allows the discrimination of the incident radiation type between photon and beta by using the ratios of the four TL detectors. Personal TL dosimeter using sintered LiF:Mg,Cu,Na,Si TL detectors has the ability to measure a personal dose equivalent Hp(d) for a wide range of photon energies.  相似文献   

5.
Within a systematic study of a novel system enabling 2D readout of TL foils, the X-ray energy and dose response was investigated in TL foils containing LiF:Mg,Cu,P (MCP-N) or CaSO4:Dy as activators. Foils were exposed to broad X-ray beams of mean energies ranging between 45 keV and 208 keV (ISO 4037 standard), with reference to 662 keV 137Cs gamma rays. The MCP-N foils, of about 380 nm emission wavelength, show a flat X-ray energy response, but low sensitivity. Due to poor TL light detection efficiency of the CCD (charge-coupled device) camera over this range of wavelengths, only doses exceeding 500 mGy can be reliably measured. In the case of CaSO4:Dy foils, their TL light emitted around 450 nm wavelengths is registered by the CCD camera with no loss of efficiency, enabling X-ray doses as low as 100 mGy to be evaluated. Unlike that of MCP-N, the dose response of CaSO4:Dy foils is highly supralinear. Nevertheless, within experimental conditions applied in this study, the 2D-TL technique may be applied to determine Entrance Surface Dose or Maximum Skin Dose in radiology. The more sensitive CaSO4:Dy foils could be used only in a well-specified radiation field (e.g., in mammography) or in qualitative dose mapping.  相似文献   

6.
Erasure of the thermoluminescence (TL) signal on detector readout is considered to be a disadvantage of TL dosimetry, as post-readout dose reassessment is then impossible in principle. A method of dose reassessment based on phototransferred thermoluminescence (PTTL) has been developed at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN) and applied to MTS-N (LiF:Mg,Ti) detectors. We demonstrate the possibility of applying PTTL for dose reassessment in MTS-N TL detectors routinely applied in the dosimetric service at IFJ PAN. Readings of TL detectors exposed to relatively high doses by the customers of our dosimetry service can now be reassessed using our automatic readers. A major obstacle in applying the PTTL method at lower exposures is the presence of residual dose accumulated in LiF:Mg,Ti detectors after many field exposure and readout cycles. Since most of the TL detectors in our service have been already used for a long time (e.g. for over 10 years in the case of some detector batches), we find that our PTTL method of dose reassessment is possible only in detectors which had received doses exceeding 5 mSv.  相似文献   

7.
In this study, lithium-tetraborate (LTB) was synthesized by three methods of high-temperature solid state, wet and combustion reactions. Copper was added to pure LTB by solution assisted method, to improve the thermoluminescence (TL) properties. The pellets of LTB were produced using pressing and sintering operations at 850 °C. The synthesized LTB pellets, exposed to the gamma radiation of 60Co source in the dose range of 5–20Gy and glow curves as well as dose–response diagrams were obtained. Ultimately, the effects of different factors on TL behaviors like dopant, crystallite size and particle morphologies were studied. The results show that between pure samples, LTB which synthesized by combustion method has higher TL sensitivity than those of other methods. However, it was seen a weak glow peak for 5Gy, due to the nanocrystalline structure of LTB. This property led to decrease TL intensity at low-doses and postponed saturation at high-doses. Fading of this sample was also less than others and has relatively better reproducibility. Among LTB:Cu pellets which synthesized by the wet reaction showed the higher TL response than others due to the creation of more traps and luminescence centers and had promising properties in the case of dose response linearity and fading.  相似文献   

8.
Nanosized ZnO:Mg phosphors were synthesized through a controlled chemical reaction. X-ray diffraction patterns confirmed that Mg entered in a substitutive way in Zn sites. To investigate their thermoluminescence (TL) properties, some samples were exposed to beta-particle irradiation. The results reported here show that Mg doping improves ZnO TL features that are important for TL dosimetry applications, such as the shape of the glow curve, the temperature at which the maximum TL intensity is observed, and the TL fading and reproducibility. No saturation clues of the TL response as a function of the dose is observed for doses below 1600 Gy.  相似文献   

9.
α-Al2O3:C晶体的热释光和光释光特性   总被引:1,自引:0,他引:1       下载免费PDF全文
杨新波  李红军  徐军  程艳  苏良碧  唐强 《物理学报》2008,57(12):7900-7905
以高纯α-Al2O3和石墨为原料,采用温梯法生长了α-Al2O3:C晶体,使用Ris TL/OSL-DA-15型热释光和光释光仪研究了其热释光和光释光特性.α-Al2O3:C晶体在462K附近有单一热释光峰,发射波长位于410nm.随着辐照剂量的增加,热释光强度逐渐增强,462K的热释光特征峰位置保持不变.α-Al2O3:C晶体的 关键词: 2O3:C')" href="#">α-Al2O3:C 热释光 光释光  相似文献   

10.
This paper reports the experimental results concerning the thermoluminescent (TL) characteristics of hydrogenated amorphous zirconium oxide (a-Zr:H) powder prepared by the sol–gel method. The advantages of this method are the homogeneity and the purity of the gels associated with a relatively low sintering temperature. Hydrogenated amorphous powder was characterized by thermal analysis and X-ray diffraction. The main TL characteristics investigated were the TL response as a function of the absorbed dose, the reproducibility of the TL readings and the fading. The undoped a-Zr:H powder presents a TL glow curve with two peaks centered at 150 and 260 °C, respectively, after beta irradiation. The TL response a-Zr:H as a function of the absorbed dose showed a linear behavior over a wide range. The results presented open the possibility to use this material as a good TL dosimeter.  相似文献   

11.
Aim of this work was to study the application of a new miniaturized Ce3+ doped SiO2 scintillation detector to in vivo dosimetry in high dose rate brachytherapy. Energy, dose-rate, temperature and angular dependences of the detector response to 192Ir HDR brachytherapy fields were investigated, as well as sensitivity reproducibility and linearity. To this aim, two ad hoc phantoms were designed and developed to perform measurements in water. Intra-session reproducibility resulted to be very high, however inter-session reproducibility showed too high statistical variation. Detector response resulted to increase linearly with dose (R2 = 0.997), with no evidence of energy and dose-rate dependence. Sensitivity resulted to increase linearly with temperature (R2 = 0.995), with a 0.2% increase each °C. Finally, no significant angular dependence for the source moving around a circle in the azimuthal plane centered at the scintillator was observed. The obtained results show that the proposed detector is suitable for in vivo real-time dosimetry in high dose rate brachytherapy.  相似文献   

12.
A batch of a naturally occurring fluorite (CaF2) from the Middle Benue Valley region of Nigeria has been studied in some detail for its thermoluminescence (TL) properties. TL glow peaks are observed at 119, 144 and 224°C at a heating rate of 10°C s−1. The TL response is observed to increase with increasing dose, as expected, over the dose range examined. Variations are observed in the decay curves of the various glow peaks with storage at room temperature. While the lower temperature peaks are observed to decay, enhancement of the TL signal is observed for the 224°C glow peak when stored for four weeks. A low-level radioactivity measurement showed no evidence of self-irradiation from naturally occurring radionuclides. UV exposure was suppressed by storage in a black sealed container to exclude sunlight contribution to the observed TL response. A scheme involving the formation of large defect complexes, from smaller ones, during storage, as possible route leading to loss of signal in low temperature glow peaks and a corresponding enhancement at higher temperature, is suggested.  相似文献   

13.
This paper presents the main thermoluminescence (TL) dosimetric characteristics of commercial Turkish transparent window glass. The structure of the glow curves, including the number of peaks, was found to be dose-dependent. A low-temperature glow peak that at 160 °C shifts to higher temperatures was also observed with increasing storage time at room temperature. This result suggests that this TL glow peak is actually made up of two or more overlapping peaks. These we have attributed to the glow peaks at lower temperatures, which decay faster than the ones at higher temperatures with storage time. The thermal fading of the window glass sample at room temperature showed a relatively sharp decay of about 60% occurring over a period of 28 days, after which the decay rate is small for a measured period of 250 days. In order to the improve the post-irradiation stability of the glow curve, the glass samples were heated after irradiation. To remove the unstable TL peaks responsible for the initial rapid fading, post-irradiation heating at 160 °C for 10 min was found to be the most suitable procedure. The dosimetric characteristics of the post-irradiation heated window glass examined in this study include fading, gamma photon dose-response, reproducibility, batch sensitivity, humidity influence, a dose-rate effect and photon energy response. Dose-response was found to be appropriate for dosimetry in the range 5 Gy to 10 kGy. The post-irradiation heating procedure did not affect the main dosimetric characteristics of the window glass samples. The results in this work suggest that the materials could, by using the TL technique, be a suitable candidate for alternative dose measurements in radiation processing, provided that a judicious choice of the post-irradiation heat temperature is made to minimize fading.  相似文献   

14.
Useful TL properties of TLD-100 that is an excellent candidate for using in TL dosimetry of ionizing radiation are demonstrated. This study is focused on response of TLD-100 subjected to photon irradiation. The thermoluminescence (TL) response of TLD-100 subject to various photon energy, ranging from 20 keV to 6 MeV, was investigated as energy absorbed in the TL material using Monte Carlo N-Particle transport code version 5 (MCNP5). The input parameters included in this study are experimental geometry specification, source information, material information, and tallies. Tally F6 is used in this simulation. The results from MCNP5 simulation show good agreement with previous experimental data. However, the data obtained from the simulation are greater than the experimental data especially in lower energy ranges.  相似文献   

15.
Well known, widely applied high sensitive thermoluminescence (TL) detector LiF:Mg,Cu,P (MCP-N) was investigated. This paper analyses changes of the TL emission spectrum of MCP-N after irradiation with ultra high doses (up to 500 kGy). Spectral dependence of TL on dose is very complex especially in the region of very high doses (>1 kGy). As a general trend we found that the number of peaks increases with dose in the long-wavelength region indicating new types of recombination centres (RCs). Wavelength peak positions for increasing doses are quite stable. Only some of them show slight red-shift.  相似文献   

16.
In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a 60Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation.  相似文献   

17.
Absolute measurement of photon flux under high-fluence rate X-rays was required in photon diagnostics for X-ray lasers. A free-air ionization chamber used for the reproducibility of air-kerma in high-fluence rate X-ray was designed, and the monoenergetic X-rays flux of (6–20) keV were absolutely measured on Beijing Synchrotron Radiation Facility. The energy spectrum of the monoenergetic X-rays was measured using a silicon drift detector, and the proportion of higher harmonics was determined. The saturation curve, air attenuation correction factor, and composite loss correction factor of the free-air ionization chamber were obtained experimentally. The air-kerma rate for the (6~20) keV monoenergetic X-ray was measured accurately, and the relative combined standard uncertainty of the air-kerma is 0.61%.  相似文献   

18.
The glow curve structures for LiF:Mg,Cu,Na,Si TL detectors with various dopant concentrations and sintering temperatures were investigated for the improvement of the glow curve structure and sensitivity of the TL detector. The dopant concentrations were varied over the following ranges: Mg (0–0.25 mol%), Cu (0–0.07 mol%), Na and Si (0–1.5 mol%). With increasing Cu concentration, the intensity of the main peak was intensified and reached a maximum at a concentration of 0.05 mol%. The high-temperature peak was reduced. The dependency of the main peak intensity on the Mg concentration exhibits a sharp maximum at 0.2 mol%. The intensity of the high-temperature peak tends to rise slightly with increasing Mg concentration. It was found that the optimum concentrations of the dopants in the LiF:Mg,Cu,Na,Si TL material are Mg: 0.2 mol%, Cu: 0.05 mol%, Na and Si: 0.9 mol%. The dependency of the main peak intensity on sintering temperature exhibits a very sharp maximum at 830°C. The high-temperature peak was rapidly reduced after 825°C.  相似文献   

19.
ABSTRACT

Number, energy and dose albedos are measured at a scattering angle of 180° for a broad beam of 662 keV gamma rays obtained from a radioactive source of 137Cs (having strength in µCi; 1 Ci?=?3.7?×?1010 disintegrations per second). The gamma beam is incident on semi-infinite thick targets of variable atomic numbers. The scattering media is divided into three sets, which are pure elements, alloys and composite materials. Experiments are carried out using a 3?×?3 NaI(Tl) scintillation detector. To obtain precision in data, the response unfolding of a scintillation detector is used, which converts the observed pulse-height distribution to a true photon spectrum over the energy range of 2.5 to 640 keV. The detector response unfolding results in the true intensity of back-scattered gamma flux by shifting the events resulting from partial absorption of photons to the full energy peak of the spectrum. In the present study, albedo factors are studied as a function of target thickness and their atomic number. The experimentally calculated numbers of back-scattered gamma photon are in good agreement with theoretically generated numbers of multiple back-scattered counts by using a Monte Carlo simulation code. The experimental data on energy and intensity of 662 keV gamma photons are used to evaluate the number, energy and dose albedos for different materials under investigation.  相似文献   

20.
LiF:Mg,Cu,P detectors produced at the Institute of Nuclear Physics in Krakow have shown very good dosimetric characteristics. Understanding of the effect of the concentration and type of dopants is important in the characterization of TL materials. The aim of work was to investigate the influence of the type and concentration of the dopants on the photon energy response of these detectors by irradiations “in air” and on the ISO water phantom in the range of mean photon energies between 33 and 164 keV. The influence of dopants on the glow curves, sensitivity and reproducibility was also examined. Results showed that measured energy dependence values are lower compared to the theoretical values both “in air” and on phantom. The type and concentration of the dopants influence the shape of the glow curves and sensitivity while for energy dependence is more important the presence of certain activators, namely copper.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号