首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive micromethod involving extraction, purification and thin-layer chromatography (TLC)-enzyme immunostaining was developed for the quantation of gangliosides and sulphatide, as markers for neuronal disorders and myelin disturbances, in individual samples of less than 5 ml of cerebrospinal fluid. The gangliosides of the gangliotetraose series were individually determined with cholera toxin subunit B by TLC-enzyme-linked immunosorbent assay (ELISA) after chromatography and subsequent sialidase hydrolysis to II3NeuAc-GgOse4Cer (GM1). Other gangliosides and sulphatide were determined with specific monoclonal antibodies by TLC-ELISA. The total ganglioside content varied between 100 and 230 nmol/l in ten normal cerebrospinal fluid samples from adults. The major gangliosides were of the gangliotetraose series, represented by GM1, IV3NeuAc,II3NeuAc-GgOse4Cer, (GD1a), II3(NeuAc)2-GgOse4Cer (GD1b) and IV3NeuAc,II3 (NeuAc)2-GgOse4Cer (GT1b) of which the b-series gangliosides dominated, i.e., GD1b and GT1b.  相似文献   

2.
A high-performance liquid chromatographic technique for the rapid assessment fatty acids in cardiac tissue is described. A level of 50.4 +/- 14.9 nmol fatty acids per g wet weight of rat myocardial tissue could be monitored. The content of the individual fatty acids C14:0, C16:0, C16:1, C18:0, C18:1, C18:2 and C20:4 amounted to 1.9, 13.5, 0.6, 14.4, 6.1, 6.5 and 7.2 nmol/g wet weight, respectively. A comparison of this method with a well established gas chromatographic technique yielded good agreement. In contrast with time-consuming gas chromatographic techniques, there is no need to isolate (unesterified) fatty acids from the other lipid classes with column chromatography or thin-layer chromatography, because the derivatizing reagent 9-anthryldiazomethane reacts highly specifically with fatty acids.  相似文献   

3.
The combination of ion mobility with matrix-assisted laser desorption/ionization allows for the rapid separation and analysis of biomolecules in complex mixtures (such as tissue sections and cellular extracts), as isobaric lipid, peptide, and oligonucleotide molecular ions are pre-separated in the mobility cell before mass analysis. In this study, MALDI-IM MS is used to analyze gangliosides, a class of complex glycosphingolipids that has different degrees of sialylation. Both GD1a and GD1b, structural isomers, were studied to see the effects on gas-phase structure depending upon the localization of the sialic acids. A total ganglioside extract from mouse brain was also analyzed to measure the effectiveness of ion mobility to separate out the different ganglioside species in a complex mixture.  相似文献   

4.
Liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) is suitable for analysis of glycosphingolipids such as fragile gangliosides avoiding the use of the sialic acid elimination. However, it was not possible to distinguish the structural isomers such as GD1a and GD1b with reversed‐phase LC/ESI‐MS by hydrophobic interaction. Here we report an effective method for targeted analysis of theoretically expanded ganglioside molecular species including structural isomers by hydrophilic interaction liquid chromatography (HILIC)/ESI‐MS with multiple reaction monitoring (MRM). As a result of MRM analysis of glycosphingolipid mixtures from porcine brain, each of the lipid classes was detected within 25 min in the following order: sulfatides > GM3 > GM2 > GM1 > GD3 > GD1a > GD2 > GD1b > GT1a > GT1b > GQ1b. For the advanced application, localization analysis of postnatal day 15 (P15) mouse cerebellum layered structures was carried out by combination of MRM and laser microdissection (LMD). As a result, GM3, GD1a, GT1b and GQ1b were abundantly detected in the molecular and granular layers, whereas GM1 was widely presented in each layered structure. These gangliosides were mainly composed of d18:1‐18:0 and d18:1‐20:0, but GM3 was d18:1‐16:0 and d18:1‐20:0. Meanwhile, sulfatide molecular species were mostly localized in the myelinated fibers and scarcely found in the molecular layer. These results suggested that our method is suitable to detect a variety of ganglioside classes and sulfatides with high sensitivity at the molecular species level and effective for localization analysis of these glycosphingolipids from mouse brain sections. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Free and protein-bound forms of early and advanced glycation-induced lysine (Lys) modifications were quantified in dairy products by LC-MS/MS using a stable isotope dilution assay. The glycation profiles for N(epsilon)-fructoselysine (FL), N(epsilon)-carboxymethyllysine (CML) and pyrraline (Pyr) were monitored in raw and processed cow milk to investigate whether free glycation products could serve as fast and simple markers to assess the extent of protein glycation in dairy products. In all milk samples, the fraction of free glycation adducts was predominantly composed of advanced modifications, e.g. 8.34+/-3.81 nmol CML per micromol of free Lys (Lys(free)) and 81.5+/-87.8 nmol Pyr micromol(-1) Lys(free)(-1) vs. 3.72+/-1.29 nmol FL micromol(-1) Lys(free)(-1). In contrast, the protein-bound early glycation product FL considerably outweighed the content of CML and Pyr in milk proteins of raw and processed cow milk, whereas severely heat treated milk products, e.g. condensed milk, contained a higher amount of protein-bound advanced glycation adducts. Typical values recorded for milk samples processed under mild conditions were 0.47+/-0.08 nmol FL micromol(-1) of protein-bound Lys (Lys(p-b)), 0.04+/-0.03 nmol CML micromol(-1) Lys(p-b)(-1) and 0.06+/-0.02 nmol Pyr micromol(-1)Lys(p-b)(-1). It was particularly noticeable, however, that mild heat treatment of raw milk, i.e. pasteurization and UHT treatment, did not significantly increase the amount of both free and protein-bound Lys modifications. In conclusion, the profiles of free and protein-bound glycation-induced Lys modifications were found to be different and a screening of free glycation adducts does, therefore, not allow for a conclusion about the protein glycation status of dairy products.  相似文献   

6.
Neolacto‐series ganglioside sialylparagloboside (SPG) is a ganglioside species present in various human tissues, and used in many important studies. In this study, four ganglioside analogs, GM3, GD3, SPG, and NeuAc‐Gal‐GlcNAc‐Gal‐GlcNAc‐Gal‐Glc‐Cer, were synthesized by the saccharide‐primer method using MDCK cells and β‐lactoside primer with different aglycons. As compared to former methods for producing SPG, the primer method was rapid and convenient. Moreover, the yield of SPG was much higher than that obtained by former methods. The production of gangliosides with an azido group in the aglycon moiety was also achieved by using MDCK cells.  相似文献   

7.
Y B Liu  K F Chan 《Electrophoresis》1991,12(6):402-408
Gangliosides are sialic acid-containing glycosphingolipids. In aqueous media, these glycolipids have been shown to exist as stable micelles. Ganglioside micelles could be analyzed by high-performance zonal capillary electrophoresis in uncoated fused-silica capillaries within 10 min. The mass sensitivity determined by monitoring the absorption of ultraviolet light at 195 nm was in the order of 10(-11) mol. Increasing the pH of the running buffer from 3.0 to 7.4 or the voltage from 10 to 30 kV increased the relative mobilities of gangliosides. By contrast, increasing the ionic strength of the buffer decreased the migration and broadened the elution peak widths of gangliosides. Ganglioside* micelles including GM1, GD1b, and GT1b were resolved into separate peaks by capillary electrophoresis at physiological pH shortly after mixing. Upon prolonged incubation, the ganglioside peaks merged to form a single species. The fusion process was temperature-dependent. At 50 degrees C, formation of mixed micelles between polysialogangliosides GD1b and GT1b was complete within 30 min. In contrast, no fusion of the ganglioside peaks was observed at 0 degrees C even after 75 h. Formation of mixed micelles between GD1b and other polysialogangliosides including GD1a, GT1b, and GQ1b at 37 degrees C required 1.5, 3.0, and 2.0 h, respectively. Formation of mixed micelles between monosialoganglioside GM1 and polysialogangliosides were 6- to 36-fold slower. No fusion was observed between monosialogangliosides GM1 and GM2 after 2 days of incubation. These findings indicate that polysialogangliosides may have higher propensities than monosialoganglioside to form mixed micelles.  相似文献   

8.
Biological thiols and disulfides in rat and hamster tissues were simultaneously determined by HPLC-fluorescence detection using 4-(aminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (ABD-F) and ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F). The coefficients of variation (CV) of the method for reduced glutathione (GSH) and oxidized glutathione (GSSG) in liver and for cysteine (CySH) and cystine (CySSCy) in kidney were less than 3.1%. In 11 tissues of Wistar rats (liver, spleen, heart, lung, stomach, bladder, ovary, uterus, adrenal, kidney and pancreas), only CySH, CySSCy, GSH and/or GSSG were detected. Other thiols and disulfides were at extremely low levels in all samples. Both concentrations of CySH and CySSCy in the livers of old rats (111 weeks old, F344) were significantly higher than those of young rats (8 weeks old) (CySH, 0.246 +/- 0.099 vs 0.130 +/- 0.020 mumol/g; CySSCy, 0.051 +/- 0.027 vs 0.013 +/- 0.002 mumol/g). Administration of N-nitrosobis(2-oxopropyl)amine (BOP), a selective carcinogen of hamster pancreatic cancer, to Syrian golden hamsters (38 weeks old) resulted in the increase in the pancreas of GSH to a level 19 times as high and of GSSG to a level 14 times as high as those in untreated hamsters (GSH, 1.173 +/- 0.272 vs 0.062 +/- 0.017 mumol/g; GSSG, 0.155 +/- 0.063 vs 0.011 +/- 0.001 mumol/g).  相似文献   

9.
We have previously reported a highly sensitive method for the measurement of catechol-O-methyltransferase (COMT) activities in rat erythrocytes with norepinephrine (NE), an endogenous native substrate, using high-performance liquid chromatography (HPLC)-fluorescence or peroxyoxalate chemiluminescence reaction detection. Applying this method to COMT activities in rat liver and kidney, known to have the highest activities of all organs, the optimum reaction conditions were investigated. Under the optimum conditions, soluble (S)-COMT and membrane-bound (MB)-COMT activities in rat liver, with NE as a substrate, were 2.17 +/- 0.33 and 0.16 +/- 0.02 nmol/min/mg protein (n = 5), respectively. In rat kidney, S-COMT and MB-COMT activities were 1.81 +/- 0.20 and 0.079 +/- 0.009 nmol/min/mg protein (n = 5), respectively. Since liver and kidney play important roles in inactivating catecholamines, using the proposed method would yield critical information to delineate the role of metabolism of catecholamines in rat tissues.  相似文献   

10.
Micellar inhibition effect of gangliosides on a degradation of drug was investigated, where ganglioside G(M1) (GM1), G(D1a) (GD1a) and G(T1b) (GTlb) whose sialic acid residue is one, two and three, respectively, were used. The base-catalyzed isomerization of prostaglandin A(2) (PGA(2)) to prostaglandin B(2) (PGB(2)) was chosen as a model experiment. The rate for the isomerization of PGA(2) was determined by measuring the concentration of PGA(2) (and PGB(2)) with a high-performance liquid chromatography. Gangliosides micelles inhibited the isomerization of PGA(2). The inhibition effect of GT1b micelles was larger than that of GD1a micelles. This result would be due to the larger absolute value of surface potential of GT1b micelles, which brings about a larger electrostatic repulsion between micellar surface and OH(-). The terminal sialic acid residue of ganglioside was effective to inhibit the isomerization of PGA(2). GM1 micelles without terminal sialic acid residue but with large aggregation number exhibited a superior steric shielding effect rather than an electrostatically repulsive effect. The inhibition effect of GM1 micelles was enhanced by the mixed micellization with the other ganglioside with a terminal sialic acid residue. GM1-GD1a or GM1-GT1b mixed micelles remarkably inhibited the isomerization of PGA(2). The physiological activity of PGs in the biological membranes containing gangliosides was also discussed.  相似文献   

11.
A method utilizing solvent extraction and analysis by gas chromatography-positive chemical ionization mass spectrometry (SE-GC-PCIMS) was developed for the analysis of three neutral hydrophobic perfluorooctanesulfonamide compounds [perfluorooctanesulfonamide (PFOSA), N-ethyl perfluorooctanesulfonamide (N-EtPFOSA), and N,N-diethyl perfluorooctanesulfonamide (N,N-Et2PFOSA)]. These compounds are suspected metabolic precursors of perfluorooctane sulfonate. The SE-GC-PCI-MS method was used to analyze all three perfluorooctanesulfonamides in fast food, fish, and Arctic marine mammal liver samples. The SE-GC-PCI-MS method produced relatively higher recoveries of the analytes (averaging 83 +/- 6%, 84 +/- 9%, and 89 +/- 19% for N,N-Et2PFOSA, N-EtPFOSA, and PFOSA, respectively) with lower coefficients of variation, and less susceptibility to matrix effects, than ion pair extraction-liquid chromatography-tandem mass spectrometric methods. Method detection limits (MDLs) were 100, 120, and 250 pg/g for N,N-Et2PFOSA, N-EtPFOSA, and PFOSA, respectively. The three compounds were found at concentrations ranging from below the MDL to 22 ng/g wet weight in fast food, fish, and Arctic marine mammal liver samples.  相似文献   

12.
A simple and reliable sample methodology based on simultaneous ultrasonic extraction, sulfuric acid clean-up and headspace solid-phase microextraction (SPME)-gas chromatography-mass spectrometry has been developed as an advantageous analytical tool for the determination of seven polychlorinated biphenyl congeners in bird livers at low levels. The influence of several parameters on the efficiency of the proposed method was systematically investigated. The clean-up efficiency of sulfuric acid treatment was tested and compared with those of column chromatography (Flosiril, silica gel and alumina) and solid-phase extraction (SPE) (Supelclean ENVI-Carb cartridge) procedures. The use of sulfuric acid in the clean-up step prior to headspace solid-phase microextraction analysis allows the removal of interfering matrix compounds present in the liver extracts that would otherwise cause severe ionization suppression of the polychlorinated biphenyls (PCBs) during the ionization process. The optimized method had good linearity (R2>0.99) over the range studied (5-500 ng/g wet weight) and showed satisfactory level of precision, with RSD values lower than 10.6%. The obtained relative recoveries ranged between 63 and 94%. The limits of detection (0.06-0.63 ng/g wet weight) were low enough to check for harmful levels of polychlorinated biphenyls in biological samples, and were well below most of the restrictive limits established by European Union regulations. The method was found to be reliable under the operational conditions proposed and was applied successfully to the analysis of individual polychlorinated biphenyls in liver tissues. The results obtained from five bird species from Greece revealed the presence of the target compounds in all samples analyzed, at levels ranging between 0.54 and 39.45 ng/g wet weight.  相似文献   

13.
Anthracyclines are very effective against soft tissue sarcomas, with cardiotoxicity being an important side effect after repeated administration. To estimate the relative cardiotoxicity of various anthracyclines and their metabolites, we developed an isolated mouse left atrium model. To relate an effect of doxorubicin, 4'-epidoxorubicin and their four main metabolites (doxorubicinol, epidoxorubicinol and the aglycons 7-deoxydoxorubicinon and 7-deoxydoxorubicinolon) to concentrations in the tissue instead of the incubation bath, a method of quantifying the anthracyclines in small tissue samples was developed. Atria were homogenized by sonication followed by extraction of the anthracyclines with methanol. The extract was directly analyzed by high-performance liquid chromatography with fluorescence detection. Recoveries for the six compounds tested ranged from 67.5% for 4'-epidoxorubicin to 100.6% for 7-deoxydoxorubinol aglycon with coefficients of variation of 2-3% at two spiked concentrations (0.1 and 1 nmol/mg of tissue). The calibration plots were linear (r2 greater than 0.996) over the concentration range tested (0.05-1 nmol/mg wet weight). The limits of detection (4-10 pmol/mg of tissue) were low enough to allow the determination of the anthracyclines at all relevant tissue concentrations.  相似文献   

14.
In this study, we developed a high-resolution tandem mass spectrometry (HR MS) approach to assess presumed changes in gangliosidome of a human hippocampus affected by temporal lobe epilepsy (TLE) in comparison with a normal hippocampus. Gangliosides, membrane glycolipids, are particularly diverse and abundant in the human brain, and participate in ion transport and modulation of neuronal excitability. Changes in structural ganglioside pattern potentially linked to TLE molecular pathogenesis have not been explored in detail. Aiming to characterize TLE-specific gangliosidome, we analyzed the native gangliosides purified from a human hippocampal tissue sample affected by TLE and a control hippocampus using HR MS. Marked differences of ganglioside expression were shown in TLE vs. control, particularly with respect to the sialylation degree of components, discovered as a characteristic feature of TLE. Another major finding is the occurrence of tetrasialofucogangliosides in TLE and species modified by either O-acetylation or CH3COO. Structural analysis by higher-energy collisional dissociation (HCD) MS/MS gave rise to fragmentation patterns implying that the GQ1b (d18:1/18:0) isomer is specifically associated with TLE. Further investigation in a larger sample is needed in order to confirm the discovery of ganglioside structures specifically expressed in human TLE and to provide information on the probable role of gangliosides in the molecular events underlying seizures.  相似文献   

15.
Abstract

As more and more biological functions1-10 of gangliosides are being revealed, their facile, stereocontrolled synthesis is strongly required. We have developed11-l4 an α-stereoselective glycosylation of sialic acids, α-sialyl-(2→8)-sialic acid and α-sialyl-(2→8)-α-sialyl-(2→8)-sialic acid, by using their 2-thioglycosides as the glycosyl donor and suitably protected acceptors, and dimethyl(methy1thio)sulfonium triflate (DMTST) or N-iodosuccinimide (NIS)-trifluoromethanesufonic acid (or TMS triflate) as the glycosyl promoter in acetonitrile. In this way, we have synthesized a variety of gangliosides15 and their analogs.16 Previously,13 we synthesized Ganglioside GD3 containing α-sialyl-(2-8)-sialic acid residue in the molecule, in connection with a novel approach for systematic synthesis of polysialo-glycoconjugates. As a part of our continuing studies on the synthesis and elucidation of the functions of gangliosides, we describe here a facile, stereocontrolled, total synthesis of ganglioside GD2. Ganglioside GD2, which was first isolated from human brain by R. Kuhn et al.,17 is well known as a human melanoma associated antigen.18  相似文献   

16.
A method of ultra-performance liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry (UPLC-ESI-MS/MS) has been established for simultaneous determination of major disialoganglioside 3 (GD3) and monosialoganglioside 3 (GM3) in infant formulas and whey protein concentrates. Gangliosides were extracted by using the technique of Svennerholm and Fredman and then cleaned up with OASIS HLB solid-phase extraction (SPE) cartridges. The various molecular species of gangliosides were separated on an Acquity UPLC BEH C8 column and analyzed under the negative ion mode. GD3 and GM3 were rapidly quantified using internal standard (IS) method. The developed method was further validated by determining the linearity, average recovery, sensitivity (limit of quantification), and precision. The results presented high correlation coefficients (R(2) > 0.993) of the selected 16 gangliosides molecular species and provided the respective linear ranges. The limit of quantification was 0.325-0.734 mg/100 g for eight molecular species of GD3 and 0.008-0.312 mg/100 g for eight molecular species of GM3, respectively. The reasonable average recoveries (81-95%) and precision (relative standard deviation [RSD] ≤15%) were also demonstrated in three different spiked levels. This new method would be very useful in the quantitative determination of gangliosides in infant formulas and whey protein concentrates.  相似文献   

17.
In this study we have explored the potential of PUVB (8-MOP + UVB) therapy for the reduction of luminal narrowing after arterial injury. In 15 rabbits, balloon dilation of iliac arteries was performed. In 20 arteries, dilation was combined with the delivery of pulsed ultraviolet light B (UVB) irradiation with 10 arteries being previously subjected to sensitizer infusion. Changes in vessel diameter, proliferation and extracellular matrix protein content at 6 weeks were evaluated by means of angiography and histomorphometry-immunohistochemistry. We found that PUVB, applied at the time of dilation, induced reduction in late loss (LL) at 6 weeks (percutaneous transluminal angioplasty vs UVB vs PUVB: 0.64 +/- 0.15 mm vs 0.61 +/- 0.05 mm vs 0.29 +/- 0.05 mm; p = 0.018). The same holds true for constrictive remodeling (0.53 +/- 0.15 mm vs 0.45 +/- 0.06 mm vs 0.15 +/- 0.05 mm; p = 0.016). In the irradiation groups, LL was independent of acute gain (AG), as opposed to the control. Collagen content increased significantly after PUVB in media and adventitia, without increased cellular proliferation in all vessel layers. Thus, PUVB at the time of dilation reduced luminal narrowing at follow-up without effecting proliferation. This effect was independent of AG and was associated with increased collagen content in media and adventitia.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) procedure for the determination and preparation of desmosine (DES) and isodesmosine (IDE), the major cross-links of elastin, has been developed. Hydrolysates of elastin are treated with a SEP-PAK silica-gel small column and then separated on a silica-gel normal phase column using n-propanol-water-25% ammonia (9:3:0.06, v/v/v) followed by detection at 275 nm. The quantitative yields of DES and IDE are 7.98 +/- 0.47 and 6.44 +/- 0.51 (mean +/- S.D., n = 10) mg/g dry weight, respectively, in bovine ligamentum nuchae. Preparations of cross-links are carried out by means of a preparative column (240 mm x 10 mm), using the same solvent system.  相似文献   

19.
A GD3-type ganglioside molecular species, LMG-4 (1), has been obtained from the polar lipid fraction of the chloroform/methanol extract of the starfish Luidia maculata. The structure of this ganglioside has been determined on the basis of chemical and spectroscopic evidence to be 1-O-[(N-acetyl-alpha-D-neuraminosyl)-(2-->8)-(N-acetyl-alpha-D-neuraminosyl)-(2-->3)-beta-D-galactopyranosyl-(1-->4)-beta-D-glucopyranosyl]-ceramide. The ceramide moiety was composed of heterogeneous 2-hydroxy fatty acid and phytosphingosine units. This is the first report on the isolation and structure elucidation of GD3-type ganglioside from echinoderms. Moreover, 1 exhibited neuritogenic activity toward the rat pheochromocytoma PC12 cells in the presence of nerve growth factor.  相似文献   

20.
4'-Epidoxorubicin, doxorubicin (internal standard) and eight metabolites were extracted from heart tissue homogenate by a mixture of tetrahydrofuran-water (1:2, v/v) and purified by C18 Sep-Pak cartridges. The buffer used to prepare the homogenate contained glucaric acid-1,4-lactone and glucose, to prevent decomposition of the 4'-epidoxorubicin glucuronides. Anthracyclines were separated by high-performance liquid chromatography within 14 min and detected by fluorescence. Recoveries ranged from 49 to 75%. The detection limits of the individual anthracyclines ranged from 0.5.10(-11) to 2.5.10(-11) mol/g wet weight. The peak-height ratios of the fluorescence intensities of the anthracyclines versus doxorubicin were linear from 2.5.10(-11) to 250.10(-11) mol/g wet weight. Within- and between-day precisions of the assay varied between the anthracyclines and were in the ranges 3-12% (n = 6) and 2-11% (n = 6), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号