首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
MALDI imaging and profiling mass spectrometry of proteins typically leads to the detection of a large number of peptides and small proteins but is much less successful for larger proteins: most ion signals correspond to proteins of m/z < 25,000. This is a severe limitation as many proteins, including cytokines, growth factors, enzymes, and receptors have molecular weights exceeding 25 kDa. The detector technology typically used for protein imaging, a microchannel plate, is not well suited to the detection of high m/z ions and is prone to detector saturation when analyzing complex mixtures. Here we report increased sensitivity for higher mass proteins by using the CovalX high mass HM1 detector (Zurich, Switzerland), which has been specifically designed for the detection of high mass ions and which is much less prone to detector saturation. The results demonstrate that a range of different sample preparation strategies enable higher mass proteins to be analyzed if the detector technology maintains high detection efficiency throughout the mass range. The detector enables proteins up to 70 kDa to be imaged, and proteins up to 110 kDa to be detected, directly from tissue, and indicates new directions by which the mass range amenable to MALDI imaging MS and MALDI profiling MS may be extended.  相似文献   

2.
Nanodiscs have become a leading technology to solubilize membrane proteins for biophysical, enzymatic, and structural investigations. Nanodiscs are nanoscale, discoidal lipid bilayers surrounded by an amphipathic membrane scaffold protein (MSP) belt. A variety of analytical tools has been applied to membrane proteins in nanodiscs, including several recent mass spectrometry studies. Mass spectrometry of full-length proteins is an important technique for analyzing protein modifications, for structural studies, and for identification of proteins present in binding assays. However, traditional matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry methods for analyzing full-length membrane proteins solubilized in nanodiscs are limited by strong signal from the MSP belt and weak signal from the membrane protein inside the nanodisc. Herein, we show that an optimized ultra-thin layer MALDI sample preparation technique dramatically enhances the membrane protein signal and nearly completely eliminates the MSP signal. First-shot MALDI and MALDI imaging are used to characterize the spots formed by the ultra-thin layer method. Furthermore, the membrane protein enhancement and MSP suppression are shown to be independent of the type of membrane protein and are applicable to mixtures of membrane proteins in nanodiscs.  相似文献   

3.
4.
The heterogeneous dielectric generalized Born (HDGB) methodology is an the extension of the GBMV model for the simulation of integral membrane proteins with an implicit membrane environment. Three large integral membrane proteins, the bacteriorhodopsin monomer and trimer and the BtuCD protein, were simulated with the HDGB model in order to evaluate how well thermodynamic and dynamic properties are reproduced. Effects of the truncation of electrostatic interactions were examined. For all proteins, the HDGB model was able to generate stable trajectories that remained close to the starting experimental structures, in excellent agreement with explicit membrane simulations. Dynamic properties evaluated through a comparison of B-factors are also in good agreement with experiment and explicit membrane simulations. However, overall flexibility was slightly underestimated with the HDGB model unless a very large electrostatic cutoff is employed. Results with the HDGB model are further compared with equivalent simulations in implicit aqueous solvent, demonstrating that the membrane environment leads to more realistic simulations.  相似文献   

5.
6.
Previously, we reported that the matrix‐assisted laser desorption ionization spectrum of a peptide became reproducible when an effective temperature was held constant. Using a calibration curve drawn by plotting the peptide‐to‐matrix ion abundance ratio versus the peptide concentration in a solid sample, a peptide could be quantified without the use of any internal standard. In this work, we quantified proteins by quantifying their tryptic peptides with the aforementioned method. We modified the digestion process; e.g. disulfide bonds were not cleaved, so that hardly any reagent other than trypsin remained after the digestion process. This allowed the preparation of a sample by the direct mixing of a digestion mixture with a matrix solution. We also observed that the efficiency of the matrix‐to‐peptide proton transfer, as measured by its reaction quotient, was similar for peptides with arginine at the C‐terminus. With the reaction quotient averaged over many such peptides, we could rapidly quantify proteins. Most importantly, no peptide standard, not to mention its isotopically labeled analog, was needed in this method. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
Matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry (IMS) is a powerful tool for the generation of multidimensional spatial expression maps of biomolecules directly from a tissue section. From a clinical proteomics perspective, this method correlates molecular detail to histopathological changes found in patient-derived tissues, enhancing the ability to identify candidates for disease biomarkers. The unbiased analysis and spatial mapping of a variety of molecules directly from clinical tissue sections can be achieved through this method. Conversely, targeted IMS, by the incorporation of laser-reactive molecular tags onto antibodies, aptamers, and other affinity molecules, enables analysis of specific molecules or a class of molecules. In addition to exploring tissue during biomarker discovery, the integration of MALDI-IMS methods into existing clinical pathology laboratory practices could prove beneficial to diagnostics. Querying tissue for the expression of specific biomarkers in a biopsy is a critical component in clinical decision-making and such markers are a major goal of translational research. An important challenge in cancer diagnostics will be to assay multiple parameters in a single slide when tissue quantities are limited. The development of multiplexed assays that maximize the yield of information from a small biopsy will help meet a critical challenge to current biomarker research. This review focuses on the use of MALDI-IMS in biomarker discovery and its potential as a clinical diagnostic tool with specific reference to our application of this technology to prostate cancer.  相似文献   

8.
Thermodynamics, the structure of integral membrane proteins, and transport   总被引:6,自引:0,他引:6  
Membranes are structures whose lipid and protein components are at, or close to, equilibrium in the plane of the membrane, but are not at equilibrium across the membrane. The thermodynamic tendency of ionic and highly polar molecules to be in contact with water rather than with nonpolar media (hydrophilic interactions) is important in determining these equilibrium and nonequilibrium states. In this paper, we speculate about the structures and orientations of integral proteins in a membrane, and about how the equilibrium and nonequilibrium features of such structures and orientations might be influenced by the special mechanisms of biosynthesis, processing, and membrane insertion of these proteins. The relevance of these speculations to the mechanisms of the translocation event in membrane transport is discussed, and specific protein models of transport that have been proposed are analyzed.  相似文献   

9.
Chaurand P  Caprioli RM 《Electrophoresis》2002,23(18):3125-3135
Mass spectrometry can be used to map the distribution of targeted compounds in tissue, providing important molecular information in many areas of biological research. Matrix assisted laser desorption/ionization - time of flight - mass spectrometry (MALDI-TOF-MS) is well suited for the analysis of tissue samples with a spatial resolution of about 30 microm for compounds in a mass range from 1000 to over 50 000 Da. Direct analysis of tissue sections requires spotting or coating of the tissue with a matrix compound typically sinapinic acid or other cinnamic acid analogs. A raster of this sample by the laser beam and subsequent mass analysis of the desorbed ions can record molecular intensities throughout the section. The overall process is illustrated by profiling and imaging of mouse epididymis sections where protein activity changes markedly throughout the section.  相似文献   

10.
Integral membrane proteins from human erythrocytes were fractionated in the presence of sodium dodecyl sulphate (SDS) on four types of high-performance hydroxyapatite columns. A column of 2-microns sintered hydroxyapatite beads from Asahi Optical (Tokyo, Japan) gave the best resolution. With this column, glycophorin was eluted early in a gradient of increasing sodium phosphate buffer concentration, the glucose transporter was eluted later in two zones, one of which contained this protein alone, and the anion transporter was eluted last. Water-soluble proteins applied in complex with SDS also separated reasonably well upon elution. The water-soluble proteins and the membrane proteins were all eluted mainly in the order of increasing polypeptide length, but with considerable individual variation. SDS-polypeptide complexes are probably adsorbed onto hydroxyapatite by the interaction of positively charged amino acid side groups with phosphate ions (at P-sites) and of negatively charged amino acid side groups and polypeptide-bound dodecyl sulphate anions with calcium ions (at C-sites). As a rule, the number of charged side groups and dodecyl sulphate anions, and thus the number of binding sites, increases with the polypeptide chain length, which explains the general order of release of the polypeptides.  相似文献   

11.
The implementation of high-throughput technologies based on qualitative and quantitative methodologies for the characterization of complex protein mixtures is increasingly required in clinical laboratories. MALDI profiling is a robust and sensitive technology although the serum high dynamic range imposes a major limitation hampering the identification of less abundant species decreasing the quality of MALDI profiling. A setup to improve these parameters has been performed for recombinant human erythropoietin (rhEPO) monitoring in serum, analyzing the effects of two commercially available columns (MARS Hu7 and Hu14) for immunodepletion, and two matrices (α-cyano-4-hydroxycinnamic acid and 2',4'-dihydroxyacetophenone) for peak quality improvement. The immunodepletion capability of both columns was determined by 2-D DIGE, which precisely revealed the efficacy of Hu14 in protein removal and the serum dynamic range decrement. In addition, the type of matrix, the sample dilution, and the efficacy of optimized parameters were used for serum profiling of ten healthy subjects before and after rhEPO treatment. The principal component analysis indicates that a combination of Hu14 column and 2',4'-dihydroxyacetophenone matrix increases data quality allowing the discrimination between treated and untreated samples, making serum MALDI profiling suitable for clinical monitoring of rhEPO.  相似文献   

12.
Although cleavable detergents were first synthesized a number of years ago, they have only recently been successfully applied to problems involving biological molecules. Recent reports have demonstrated that these compounds are useful for applications involving both 2D PAGE and mass spectrometry. However, most cleavable surfactants have utilized acid-labile functional groups to affect cleavage. In applications where extreme pH is required, acid cleavable detergents have limited usefulness. We report the synthesis of fluoride cleavable silane compounds and photolabile cinnamate esters as cleavable detergents having alternative cleavage chemistries than previously reported cleavable detergents. These compounds were applied to whole cell analysis using MALDI mass spectrometry, and it was demonstrated that their use results in an increase in the number of proteins analyzed by increasing protein solubility.  相似文献   

13.
《Chemistry & biology》1997,4(10):739-749
Background: A key structural issue for all integral membrane proteins is the exposure of individual residues to the intracellular or extracellular media. This issue involves the basic transmembrane topology as well as more subtle variations in surface accessibility. Direct methods to evaluate the degree of exposure for residues in functional proteins expressed in living cells would be highly valuable. We sought to develop a new experimental method to determine highly surface-exposed residues, and thus transmembrane topology, of membrane proteins expressed in Xenopus oocytes.Results: We have used the in vivo nonsense suppression technique to incorporate biotinylated unnatural amino acids into functional ion channels expressed in Xenopus oocytes. Binding of 125I-streptavidin to biotinylated receptors was used to determine the surface exposure of individual amino acids. In particular, we studied the main immunogenic region of the nicotinic acetylcholine receptor. The biotin-containing amino acid biocytin was efficiently incorporated into five sites in the main immunogenic region and extracellular streptavidin bound to one residue in particular, α70. The position of α70 as highly exposed on the receptor surface was thus established.Conclusions: The in vivo nonsense suppression technique has been extended to provide the first in a potential series of methods to identify exposed residues and to assess their relative exposure in functional proteins expressed in Xenopus oocytes.  相似文献   

14.
Integral proteins containing two or more alpha-helical membrane-spanning domains are underrepresented in two-dimensional gels. While sodium dodecyl sulfate (SDS)-polyacrylamide gels separate these proteins, staining profiles are usually dominated by high-abundance hydrophilic proteins in the specimen. A fluorescence-based stain is presented that selectively highlights integral proteins containing two or more alpha-helical transmembrane domains but does not detect lipoproteins or proteins with hydrophobic pockets, such as albumin. The stain detects as little as 5-10 ng of bacteriorhodopsin, a seven-helix transmembrane protein. Stained proteins are detected using a laser scanner or charge-coupled device (CCD) camera imaging system. Fluorescence intensity of stained bands is linear with protein quantity over at least two orders of magnitude. After visualizing transmembraneous proteins, the total protein profile may be revealed using a general protein stain. Analysis of the multisubunit protein F1F0 ATP synthase revealed selective staining of the a and c subunits, polypeptides known to possess 5 and 2 transmembrane domains, respectively.  相似文献   

15.
16.
A new analytical approach using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) for the study of honeybee venom is shown. In vitro and in vivo models simulating the bee sting have been developed using live honeybees and, as the envenomation sites, pig ears and rat legs; MALDI MSI has been used to map, over time, the diffusion and distribution of three venom allergens (Api m 1, Api m 4, and Api m 6) and two venom toxins (apamine and mast cell degranulating peptide). In conjunction with other classical biochemical techniques and high resolution mass spectrometry (HRMS), structural data have been obtained that contribute to current understanding of honeybee venom composition. Initial data have also been obtained demonstrating the feasibility of mapping the organism's response to the sting. The opportunity to monitor venom diffusion and the organism's response at the same time might open new pathways for in vivo preclinical studies in designing and testing new venom immunotherapy (VIT).  相似文献   

17.
Summary A mixture of integral membrane proteins from Sendai virus was used as a model to study the effect of various detergents and organic solvent on the purification by size-exclusion high-performance liquid chromatography (HPLC) on two tandemly linked Superose-6 columns. The best separations were obtained with either 0.1% sodium dodecyl sulphate, 0.05% sarkosyl or 0.1% lauryldimethylamineoxide in the eluent. In addition, the effect of the eluent on the immunological activity as a measure of intact structure was studied. A considerable part of the protein structure remained intact after HPLC and was able to react with antibodies directed against the intact virus proteins.  相似文献   

18.
Aromatic residues are frequently found in helical and beta-barrel integral membrane proteins enriched at the membrane-water interface. Although the importance of these residues in membrane protein folding has been rationalized by thermodynamic partition measurements using peptide model systems, their contribution to the stability of bona fide membrane proteins has never been demonstrated. Here, we have investigated the contribution of interfacial aromatic residues to the thermodynamic stability of the beta-barrel outer membrane protein OmpA from Escherichia coli in lipid bilayers by performing extensive mutagenesis and equilibrium folding experiments. Isolated interfacial tryptophanes contribute -2.0 kcal/mol, isolated interfacial tyrosines contribute -2.6 kcal/mol, and isolated interfacial phenylalanines contribute -1.0 kcal/mol to the stability of this protein. These values agree well with the prediction from the Wimley-White interfacial hydrophobicity scale, except for tyrosine residues, which contribute more than has been expected from the peptide models. Double mutant cycle analysis reveals that interactions between aromatic side chains become significant when their centroids are separated by less than 6 A but are nearly insignificant above 7 A. Aromatic-aromatic side chain interactions are on the order of -1.0 to -1.4 kcal/mol and do not appear to depend on the type of aromatic residue. These results suggest that the clustering of aromatic side chains at membrane interfaces provides an additional heretofore not yet recognized driving force for the folding and stability of integral membrane proteins.  相似文献   

19.
Comprehensive metabolome analysis using mass spectrometry (MS) often results in a complex mass spectrum and difficult data analysis resulting from the signals of numerous small molecules in the metabolome. In addition, MS alone has difficulty measuring isobars and chiral, conformational and structural isomers. When a matrix-assisted laser desorption ionization (MALDI) source is added, the difficulty and complexity are further increased. Signal interference between analyte signals and matrix ion signals produced by MALDI in the low mass region (<1500 Da) cause detection and/or identification of metabolites difficult by MS alone. However, ion mobility spectrometry (IMS) coupled with MS (IM-MS) provides a rapid analytical tool for measuring subtle structural differences in chemicals. IMS separates gas-phase ions based on their size-to-charge ratio. This study, for the first time, reports the application of MALDI to the measurement of small molecules in a biological matrix by ion mobility-time of flight mass spectrometry (IM-TOFMS) and demonstrates the advantage of ion-signal dispersion in the second dimension. Qualitative comparisons between metabolic profiling of the Escherichia coli metabolome by MALDI-TOFMS, MALDI-IM-TOFMS and electrospray ionization (ESI)-IM-TOFMS are reported. Results demonstrate that mobility separation prior to mass analysis increases peak-capacity through added dimensionality in measurement. Mobility separation also allows detection of metabolites in the matrix-ion dominated low-mass range (m/z < 1500 Da) by separating matrix signals from non-matrix signals in mobility space.  相似文献   

20.
The alignment of membrane proteins provides pertinent structural and dynamic information. Structural topology data gleaned from such studies can be used to determine the functional mechanisms associated with a wide variety of integral membrane proteins. In this communication, we successfully demonstrate, for the first time, the determination of the structural topology and helical tilt of an antimicrobial peptide magainin 2 using aligned X-band spin-label EPR spectroscopic techniques. This novel comparison unlocks many possibilities utilizing EPR spectroscopy to probe antimicrobial peptide topologies with increased sensitivity and may also give further clues to elucidate their corresponding mechanisms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号