首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Highly luminescent complexes of Eu and Tb ions with norfloxacin (NFLX) and gatifloxacin (GFLX) were prepared in sol–gel matrix. The red and green emissions of Eu and Tb ions were obtained by the energy transfer from the triplet state of (NFLX) and (GFLX) to the excited emitting states (5D0 and 5D4) of Eu and Tb, respectively. The intensity of the electric field emission bands (5D07F2, 617 nm and 5D47F5, 545 nm) of Eu and Tb ions were proportional to the concentration of (NFLX at pH 6.0) and (GFLX at pH 3.5) in acetonitrile with excitation wavelengths (λex) (340 and 395) and (370 and 350 nm) for Eu and Tb ions, respectively. The monitored luminescence intensity of the system showed a good linear relationship with the concentration of NFLX within a range of 5×10?9–5.8×10?6 and 5×10?8–1.0×10?6 mol L?1 with a correlation coefficient of 0.990, and for GFLX within a range of 2.4×10?9–3.2×10?5 and 5×10?8–8.0×10?6 mol L?1 with a correlation coefficient of 0.995. The detection limit (LOD) was determined as 3.0×10?9 and 1.0×10?8 mol L?1 for NFLX and 1.6×10?10 and 2.0×10?8mol L?1 for GFLX. The limit of quantification (LOQ) is 9×10?9 and 3.0×10?8 and 4.8×10?10 and 6.0×10?8 in case of Eu and Tb, respectively.  相似文献   

2.
Abstract

The effects of three systems on the chemiluminescence (CL) intensity have been studied in this paper, such as leucogen–potassium permanganate–rhodamine B, leucogen–cerium (IV)–rhodamine B, and leucogen–luminol–hydrogen peroxide (called system 1, system 2, and system 3, respectively). The mechanism of these reactions is also discussed. Surfactant (CTMAB) has a remarkably sensitive effect on these systems mentioned above. Therefore, three new flow injection chemiluminescence methods for the determination of leucogen have been established. For system 1, the linear range is 8.0×10?8 to 4.0×10?5 g mL?1, with limits of detection 2×10?8 g mL?1; the relative standard deviation is 2.5% (n=11, Cs=4.0×10?6 g mL?1). For system 2, the linear range is 1.0×10?8 to 5.0×10?6 g mL?1, with limits of detection 3×10?9 g mL?1; the relative standard deviation is 5.1% (n=11, Cs=1.0×10?6 g mL?1). For system 3, the linear range is 4.0×10?8 to 2.0×10?6 g mL?1, with limits of detection 1×10?8 g mL?1; the relative standard deviation is 1.3% (n=11, Cs=1.0×10?7 g mL?1). Compared with the three methods above, system 3 is confirmed as the best method. This method has been applied to the determination of leucogen with satisfactory results.  相似文献   

3.
A novel, sensitive, and convenient method for the determination of uracil and thymine by functionalized CdS nanoparticles (NPs) was proposed. CdS NPs were prepared by hydrothermal process and modified with thioglycollic acid (TGA) in aqueous solution. The fluorescence intensity of functionalized CdS NPs was quenched in the presence of uracil or thymine. Under optimal conditions, the relative fluorescence intensity (F0/F) was proportional to the concentration in the range of 9.0×10?6–1.0×10?4 mol/L for uracil (r=0.9985) and 8.8×10?7–1.5×10?4 mol/L for thymine (r=0.9960). The corresponding detection limits were 9.6×10?7 mol/L and 3.2×10?7 mol/L, respectively. In addition, the possible quenching mechanism was also discussed.  相似文献   

4.
We report on the stress–density and rate-dependent response for Ta, ramp compressed to 330?GPa with strain rates up to 5?×?108?s?1. We employ temporally shaped laser drives to compress Ta stepped foils over several to tens of nanoseconds. Lagrangian wave-profile analysis reveals a stress–density relationship which falls below the Hugoniot, above the hydrostat, and is consistent with ramp-compression experiments at lower strain rates. We also report on the peak elastic stress prior to plastic deformation as a function of strain rate for laser-driven ramp and shock-compression data spanning the 1–50?×?107?s?1 strain-rate range. When combined with previously published lower strain data (101–107?s?1), we observe a change in rate dependence, suggesting a transition from thermally activated to defect-limited (phonon drag) dislocation motion occurring at a strain rate of about 105?s?1.  相似文献   

5.
GaP(001) cleaned by argon-ion bombardment and annealed at 500°C showed the Ga-stabilized GaP(001)(4 × 2) structure. Only treatment in 10?5 Torr PH3 at 500°C gave the P-stabilized GaP(001)(1 × 2) structure. The AES peak ratio PGa is 2 for the (4 × 2) and 3.5 for the (1 × 2) structure. Cs adsorbs with a sticking probability of unity up to 5 × 1014 Cs atoms cm?2 and a lower one at higher coverages. The photoemission measured with uv light of 3660 Å showed a maximum at the coverage of 5 × 1014 atoms cm?2. Cs adsorbs amorphously at room temperature, but heat treatment gives ordered structures, which are thought to be reconstructed GaP(001) structures induced by Cs. The LEED patterns showed the GaP(001)(1 × 2) Cs structure formed at 180°C for 10 h with a Cs coverage of 5 × 1014 atoms cm?2, the GaP(001)(1 × 4) Cs formed at 210°C for 10 hours with a Cs coverage of 2.7 × 1014 atoms cm?2, the GaP(001)(7 × 1) and the high temperature GaP(001)(1 × 4), the latter two with very low Cs content. Desorption measurements show three stability regions: (a) between 25–150°C for coverages greater than 5 × 1014 atoms cm?2, and an activation energy of 1.2 eV; (b) between 180–200°C with a coverage of 5 × 1014 atoms cm?2, and an activation energy of 1.8 eV; (c) between 210–400°C with a coverage of 2.7 × 1014 atoms cm?2, and an activation energy of 2.5 eV.  相似文献   

6.
Abstract

Three new bands of the B 2Σ+X 2Σ+ system of 12C17O+ have been investigated using conventional spectroscopic techniques. The spectra were observed in a graphite hollow‐cathode lamp by discharging molecular oxygen (enriched in about 45% of the 17O2 isotope) under 1.0 Torr pressure. The rotational analysis of the 2–4, 2–5, and 2–6 bands was performed with the effective Hamiltonian of Brown (Brown et al., J. Mol. Spectrosc. 1979; 74: 294–318). Molecular constants were derived from a merge calculation, including both the current wavenumbers and the spectroscopic data published by the authors previously. The principal equilibrium constants for the ground state of 12C17O+ are ωe=2185.9658(84), ωe x e = 14.7674(11), B e=1.927001(38), αe=1.8236(22)×10?2, γe=?0.331(28)×10?4, D e=6.041(12)×10?6, βe=0.100(31)×10?7 cm?1, and the equilibrium constants for the excited state are σe=45876.499(15), ωe=1712.201(12), ωe x e=27.3528(39), B e=1.754109(35), αe=2.8706(57)×10?2, γe = ?1.15(19)×10?4, D e=7.491(20)×10?6, βe=2.13(12)×10?7, γe = 2.0953(97)×10?2, and αγe=?9.46(59)×10?4 cm?1, respectively. Rydberg–Klein–Rees potential energy curves were constructed for the B 2Σ+ and X 2Σ+ states of this molecule, and Franck–Condon factors were calculated for the vibrational bands of the BX system.  相似文献   

7.
A novel biosensor has been constructed by incorporating modified nanosized natural zeolite and 3-hydroxypropanaminium acetate (HPAA) as a novel room temperature ionic liquid, supported on multiwalled carbon nanotube (MWCNTs) and employed for the simultaneous determination of dopamine (DA) and uric acid (UA). A detailed investigation by transmission electron microscopy and electrochemistry is performed in order to elucidate the preparation process and properties of the composites. The voltammetric studies using the modified carbon paste electrode show two well-resolved anodic peaks for DA and UA with a potential difference of 160 mV, revealing the possibility of the simultaneous electrochemical detection of these compounds. The modified carbon paste electrode shows good conductivity, stability, and extraction effect due to the synergic action of HPAA, MWCNTs, and iron ion-doped natrolite zeolite. Under optimized conditions, the peak currents are linear from 8.12?×?10?7 to 3.01?×?10?4?mol?L?1 and from 9.31?×?10?7 to 3.36?×?10?4?mol?L?1 with detection limits of 1.16?×?10?7 and 1.33?×?10?7?mol?L?1 for DA and UA using the differential pulse voltammetric method, respectively. Finally, the modified carbon paste electrode proved to have good sensitivity and stability and is successfully applied for the simultaneous determination of DA and UA in human blood serum and urine samples.  相似文献   

8.
In this study, poly (vinyl chloride)(PVC) membrane electrodes with/without multi-walled carbon nanotubes (MWCNTs) based on a calix[4]arene derivative for perchlorate ion were described. The influence of membrane composition, pH, conditioning solution on the potentiometric response of the electrodes was investigated. Perchlorate-selective PVC membrane electrode exhibited a slope of 47.8 ± 0.6 mV/pClO4 in the range of 1.0 × 10?7–1.0 × 10?1 mol L?1at pH 4.0 while the coated Pt electrodes with MWCNT-OH, MWCNT-COOH and MWCNT displayed slopes of 46.1 ± 0.7 mV/pClO4 (5.0 × 10?6–1.0 × 10?1 mol L?1), 50.4 ± 1.9 mV/pClO4 (1.0 × 10?6–1.0 × 10?1 mol L?1) and 44.4 ± 0.3 mV/pClO4 (1.0 × 10?5–1.0 × 10?1 mol L?1), respectively. Other response characteristics of these electrodes such as response time, lifetime and detection limit were identified, and the selectivity coefficients towards various anions were calculated by separate solution method. Moreover, the perchlorate-selective electrodes described here were successfully used as an indicator electrode for the determination of perchlorate in real samples such as tap water, river water and human urine by direct calibration method.  相似文献   

9.
The CdSe quantum dots (QDs) capped with 2-mercaptonicotinic acid (H2MN) were prepared through a controllable process at 80 °C. The prepared QDs were characterized by XRD, TEM, IR, UV–Vis and fluorescence (FL) techniques. It was found that the QDs were nearly mono-disperse with the diameters in the range of 8–10 nm. These QDs are capable to exhibit strong FL even in concentrated acidic media. They exhibit an enhanced fluorescence in the presence of Cr(VI), which was used for the determination of Cr(VI) in water samples. The linear range was found to be 1?×?10?7–6.0?×?10?6 M with the RSD and DL of 0.92 % and 5?×?10?8 M, respectively. Except that Ca2+ and Fe3+ which can be eliminated through a simple precipitation process, the other co-existent ions present in natural water were not interfered. The recoveries obtained for the added amounts of Cr(VI) were in the range of 96.9–103.2 %, which denote on application of the method, satisfactorily.  相似文献   

10.
ABSTRACT

The interaction between metal complex Cu2+–ARS (Alizarin Red S) and l-cysteine was investigated via fluorescence and absorption spectroscopies. In pH 5.2 Britton–Robinson buffer, the addition of L-cysteine into Cu2+–ARS system resulted in a fluorescence enhancement because cysteine reduced Cu2+ to Cu+, which led to Cu2+–ARS decompound, and ARS was released. The result was also supported by absorption spectroscopy change. A good linear response of fluorescence intensity as a function of cysteine concentration was obtained ranging from 1.0 × 10?6 to 4.0 × 10?5 mol L?1 with the detection limit as 1.08 × 10?7 mol L?1. The introduced method has high selectivity over other amino acids such as cystine, tyrosine, tryptophan, methionine, and glycine. It was applied to determine cysteine in protein hydrolysate of fresh pig blood with recovery of 88.4–100.2%.  相似文献   

11.
A chitosan/ionic liquid composite electrode was prepared and used to determine uric acid (UA) in the presence of a large excess of ascorbic acid (AA) and dopamine (DA) by linear sweep voltammetry (LSV). The modified electrode shows large peak separations between DA, AA, and UA. Due to the existence of chitosan and ionic liquid in the composite, the modified electrode exhibits strong electrochemical catalytic activity toward the oxidation of UA. Under optimal conditions, the peak current is linearly dependent on the UA concentration in the range of 5?×?10?7–2?×?10?4 M in the presence of 5?×?10?4 M AA and 5?×?10?5 M DA with a correlation coefficient of 0.9978, and the detection limit is 5?×?10?8 M at a signal-to-noise ratio of 3. With good sensitivity and stability, the constructed sensor was applied in the determination of UA in human serum samples and satisfactory results were obtained.  相似文献   

12.
Jing Li  Huaqing Xie 《Ionics》2013,19(1):105-112
A sensitive hydroxylamine sensor is developed by electrodeposition of Pt nanoparticles on pre-synthesized polypyrrole nanoparticles modified glassy carbon electrode. The modified electrode presents distinctly electrocatalytic activity toward hydroxylamine oxidation. The kinetic parameters such as the overall numbers of electrons involved in hydroxylamine oxidation, the electron transfer coefficient, standard heterogeneous rate constant, and diffusion coefficient are evaluated. The current response increases linearly with increasing hydroxylamine concentrations and exhibits two wide linear ranges of 5.0?×?10?7–1.1?×?10?3 and 1.1?×?10?3–18.8?×?10?3 M with a detection limit of 0.08 μM (s/n?=?3). The proposed electrode presents excellent operational and storage ability for determining hydroxylamine. Moreover, the sensor shows good sensitivity, selectivity, and reproducibility properties.  相似文献   

13.
At fusion plasma electron temperature and number density regimes of 1?×?103–1?×?107?K and 1?×?1028–1?×?1031/m3, respectively, the excited states and radiative transition of hydrogen-like ions in fusion plasmas are studied. The results show that quantum plasma model is more suitable to describe the fusion plasma than the Debye screening model. Relativistic correction to bound-state energies of the low-Z hydrogen-like ions is so small that it can be ignored. The transition probability decreases with plasma density, but the transition probabilities have the same order of magnitude in the same number density regime.  相似文献   

14.
This work is devoted to studying the parameters of the cathode spot of a vacuum arc. According to calculations under conditions of autoelectronic emission, the temperature of the cathode spot is T n = (1–2.5) × 103 K, the electric-field strength is E = (1–6) × 107 V cm?1, and the current density in the spot is j n = (0.15–3) × 107 A cm?2. The values of the cathode-spot parameters for cathodes of different materials are obtained and the type of electron emission is determined.  相似文献   

15.
Sulan Liao 《光谱学快报》2013,46(5):473-485
Abstract

A new flow‐injection chemiluminescence (CL) method is described for the determination of carbendazim. The method is based on the CL reaction of luminol and hydrogen peroxide (H2O2). Carbendazim can greatly enhance the chemiluminescence intensity in sodium hydroxide–sodium dihydrogen phosphate (NaOH–NaH2PO4) medium (pH=12.6). Under the optimum conditions, the linear range for the determination of carbendazim is 2.00×10?8 to 2.00×10?6 g mL?1 with a detection limit (S/N=3) of 7.24×10?9 g mL?1. The relative standard deviation is 1.8% for 1.0×10?7 g mL?1 carbendazim (n=8). The proposed method has been applied to the determination of carbendazim in tap‐water samples. Furthermore, the possible enhanced CL mechanism is discussed by examining the CL spectra and fluorescence spectra.  相似文献   

16.
The frequency (ν = 10?1–107 Hz) dependences σ(ν) of the conductivity of single crystals of the Pb0.67Cd0.33F2 superionic conductor with the fluorite-type structure (CaF2) in the temperature range of 132–395 K have been studied. The dependences σ(ν) have been discussed in the framework of the hopping relaxation of ionic carriers, which are mobile anions F?. From experimental curves σ(ν), the direct-current (dc) conductivity σdc and the average charge carrier hopping frequency νh have been determined. This has made it possible to calculate the charge carrier mobility μmob and charge carrier concentration n mob in these crystals. At room temperature (293 K), the electrical parameters are σdc = 1.6 × 10?4 S/cm, νh = 2.7 × 107 Hz, μmob = 2.0 × 10?7 cm2/(s V), and n mob = 5.1 × 1021 cm?3.  相似文献   

17.
A new fluorescence enhancement phenomenon in the europium(III)–balofloxacin–sodium dodecyl sulfate system was observed when yttrium(III) was added. Based on this, a sensitive cofluorescence assay for the estimation of balofloxacin was established. Under the optimized conditions, the enhanced fluorescence signal was linear over the concentration of balofloxacin ranging from 3.0 × 10?9 to 7.0 × 10?6 mol L?1 with a correlation coefficient of 0.9993. The detection limit (3 σ) was determined as 8.3 × 10?10 mol L?1. The presented method was successfully applied to determination of balofloxacin in pharmaceutical preparations, human serum, and urine. The possible fluorescence enhancement mechanism was also discussed.  相似文献   

18.
Epitaxially grown GaAs(001), (111) and (1?1?1?) surfaces and their behaviour on Cs adsorption are studied by LEED, AES and photoemission. Upon heat treatment the clean GaAs(001) surface shows all the structures of the As-stabilized to the Ga-stabilized surface. By careful annealing it is also possible to obtain the As-stabilized surface from the Ga-stabilized surface, which must be due to the diffusion of As from the bulk to the surface. The As-stabilized surface can be recovered from the Ga-stabilized surface by treating the surface at 400°C in an AsH3 atmosphere. The Cs coverage of all these surfaces is linear with the dosage and shows a sharp breakpoint at 5.3 × 1014 atoms cm?2. The photoemission reaches a maximum precisely at the dosage of this break point for the GaAs(001) and GaAs(1?1?1?) surface, whereas for the GaAs(111) surface the maximum in the photoemission is reached at a higher dosage of 6.5 × 1014 atoms cm?2. The maximum photoemission from all surfaces is in the order of 50μA Im?1 for white light (T = 2850 K). LEED measurements show that Cs adsorbs as an amorphous layer on these surfaces at room temperature. Heat treatment of the Cs-activated GaAs (001) surface shows a stability region of 4.7 × 1014 atoms cm?2 at 260dgC and one of 2.7 × 1014 atoms cm?2 at 340°C without any ordering of the Cs atoms. Heat treatment of the Cs-activated GaAs(111) crystal shows a gradual desorption of Cs up to a coverage of 1 × 1014 atoms cm?2, which is stable at 360°C and where LEED shows the formation of the GaAs(111) (√7 × √7)Cs structure. Heat treatment of the Cs-activated GaAs(1?1?1?) crystal shows a stability region at 260°C with a coverage of 3.8 × 1014 atoms cm?2 with ordering of the Cs atoms in a GaAs(1?1?1?) (4 × 4)Cs structure and at 340°C a further stability region with a coverage of 1 × 1014 at cm?2 with the formation of a GaAs(1?1?1?) (√21 × √21)Cs structure. Possible models of the GaAs(1?1?1?) (4 × 4)Cs, GaAs(1?1?1?)(√21 × √21)Cs and GaAs(111) (√7 × √7)Cs structures are given.  相似文献   

19.
A. K. Nath  A. Kumar 《Ionics》2014,20(12):1711-1721
Swift heavy ion (SHI) irradiation has been used as a tool to enhance the electrochemical properties of ionic liquid-based nanocomposite polymer electrolytes dispersed with dedoped polyaniline (PAni) nanorods; 100 MeV Si9+ ions with four different fluences of 5?×?1010, 1?×?1011, 5?×?1011, and 1?×?1012 ions cm?2 have been used as SHI. XRD results depict that with increasing ion fluence, crystallinity decreases due to chain scission up to fluence of 5?×?1011 ions cm?2, and at higher fluence, crystallinity increases due to cross-linking of polymer chains. Ionic conductivity, electrochemical stability, and dielectric properties are enhanced with increasing ion fluence attaining maximum value at the fluence of 5?×?1011 ions cm?2 and subsequently decrease. Optimum ionic conductivity of 1.5?×?10?2 S cm?1 and electrochemical stability up to 6.3 V have been obtained at the fluence of 5?×?1011 ions cm?2. Ac conductivity studies show that ion conduction takes place through hopping of ions from one coordination site to the other. On SHI irradiation, amorphicity of the polymer matrix increases resulting in increased segmental motion which facilitates ion hopping leading to an increase in ionic conductivity. Thermogravimetric analysis (TGA) measurements show that SHI-irradiated nanocomposite polymer electrolytes are thermally stable up to 240–260 °C.  相似文献   

20.
The e + e ?→ηγ→7γ process was studied in the energy range 2E=600–1060 MeV with an SND detector on a VEPP-2M e + e ? collider. The decay branching ratios B(φ→ηγ)=(1.353±0.011±0.052)×10?2, B(ω→ηγ)=(4.62±0.71±0.18)×10?4, and B(ρ→ηγ)=(2.73±0.31±0.15)×10?4 were measured.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号