首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dynamic slice-wise shimming improves B0 field homogeneity by updating shim coil currents for every slice in a multislice acquisition, producing better field homogeneity over a volume than can be obtained by a single static global shim. The first aim of this work was to evaluate the performance of slice-wise field-map-based second-order dynamic shimming in a human high-field 7 T clinical scanner vis-à-vis image based second order static global shimming. Another goal was to characterize eddy currents induced by second and third order shim switching. A final aim was to compare global and dynamic shimming through shim orders to elucidate the relative benefits of going to higher orders and to dynamic shim updating from a static shimming regime. An external hardware module was used to store and dynamically update slice-optimized shim values during multislice data acquisition. High-bandwidth multislice gradient echo scans with B0 field mapping and low-bandwidth single-shot echo planar scans were performed on phantoms and humans using second-order dynamic and static global shims. For the measurement of second and third order shim induced eddy currents, step response temporal phase changes of individual shims were measured and fit to shim harmonics spatially and to multiexponential decay functions temporally. Finally, an order-wise field-map-based comparison was performed with first, second and third order global static shimming, first and second order dynamic shimming, as well as combined second or third order global and first order dynamic shim. Dynamic shimming considerably improved B0 homogeneity compared to static global shimming both in phantoms and in human subjects, reducing image distortion and signal dropout. The unshielded second and third order shims generated strong B0 and self and cross-term eddy fields, with multiple time constants ranging from milliseconds to seconds. Field homogeneity improved with increasing order of shim, with dynamic shimming performing better than global shimming. Hybrid global and dynamic shimming approach yielded field homogeneity better than global static shims but worse than dynamic shims.  相似文献   

2.
High quality magnetic field homogenization of the human brain (i.e. shimming) for MR imaging and spectroscopy is a demanding task. The susceptibility differences between air and tissue are a longstanding problem as they induce complex field distortions in the prefrontal cortex and the temporal lobes. To date, the theoretical gains of high field MR have only been realized partially in the human brain due to limited magnetic field homogeneity.A novel shimming technique for the human brain is presented that is based on the combination of non-orthogonal basis fields from 48 individual, circular coils. Custom-built amplifier electronics enabled the dynamic application of the multi-coil shim fields in a slice-specific fashion. Dynamic multi-coil (DMC) shimming is shown to eliminate most of the magnetic field inhomogeneity apparent in the human brain at 7 T and provided improved performance compared to state-of-the-art dynamic shim updating with zero through third order spherical harmonic functions. The novel technique paves the way for high field MR applications of the human brain for which excellent magnetic field homogeneity is a prerequisite.  相似文献   

3.
胡洋  王秋良  李毅  朱旭晨  牛超群 《物理学报》2016,65(21):218301-218301
在磁共振成像设备中,为了消除目标区域内的高阶谐波磁场分量,传统方法采用无源匀场,但该方法匀场精度较低,针对性较差,适用于全局匀场,而有源匀场则可以通过优化线圈分布来产生所需要的特定的磁场分布.但是,由于匀场线圈线型的复杂度会随着线圈阶数的增加而增加,难以满足设计需要,因此本文提出了一种用于磁共振成像超导匀场线圈系统的多变量非线性优化设计方法.该方法基于边界元方法,将匀场线圈所产生的磁场与目标磁场之间的偏差作为目标函数,线匝间距、线圈半径等作为约束条件,通过非线性优化算法,得到满足设计要求的线圈分布.通过一个中心磁场为0.5 T的开放式双平面磁共振成像超导轴向匀场线圈的设计案例,说明本方法具有计算效率高、灵活性好的特点.  相似文献   

4.
The use of high magnetic fields increases the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS) of brain metabolites. Practical limitations arise, however, from susceptibility-induced field distortions, which are increased at higher magnetic field strengths. Solutions to this problem include optimized shimming, provided that active, i.e., electronic, shimming can operate over a sufficient range. To meet our shim requirements, which were an order of magnitude greater than the active shim capacity of our 7T MR system, we developed a combined passive and active shim approach. Simple geometries of ferromagnetic shim elements were derived and numerically optimized to generate a complete set of second-order spherical harmonic shim functions in a modular manner. The major goals of the shim design were maximization of shim field accuracy and ease of practical implementation. The theoretically optimized ferro-shim geometries were mounted on a cylindrical surface and placed inside the magnet bore, surrounding the subject's head and the RF coil. Passive shimming generated very strong shim fields and eliminated the worst of the field distortions, after which the field was further optimized by flexible and highly accurate active shimming. Here, the passive-shimming procedure was first evaluated theoretically, then applied in phantom studies and subsequently validated for in vivo 1H MRS in the macaque visual cortex. No artifacts due to the passive shim setup were observed; adjustments were reproducible between sessions. The modularity and the reduction to two pieces per shim term in this study is an important simplification that makes the method applicable also for passive shimming within single sessions. The feasibility of very strong, flexible and high-quality shimming via a combined approach of passive and active shimming is of great practical relevance for MR imaging and spectroscopy at high field strengths where shim power is limited or where shimming of specific anatomical regions inherently requires strong shim fields.  相似文献   

5.
A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties.  相似文献   

6.
Low-field nuclear magnetic resonance magnet(2 MHz) is required for rock core analysis. However, due to its low field strength, it is hard to achieve a high uniform B_0 field only by using the passive shimming. Therefore, active shimming is necessarily used to further improve uniformity for Halbach magnet. In this work, an equivalent magnetic dipole method is presented for designing shim coils. The minimization of the coil power dissipation is considered as an optimal object to minimize coil heating effect, and the deviation from the target field is selected as a penalty function term. The lsqnonlin optimization toolbox of MATLAB is used to solve the optimization problem. Eight shim coils are obtained in accordance with the contour of the stream function. We simulate each shim coil by ANSYS Maxwell software to verify the validity of the designed coils. Measurement results of the field distribution of these coils are consistent with those of the target fields.The uniformity of the B_0 field is improved from 114.2 ppm to 26.9 ppm after using these shim coils.  相似文献   

7.
An optimized passive shimming method with iron shims is presented in this paper. First, the influence value of a single iron or magnetized shim is fast calculated and determined by analytic solution with a single practical measurement. Then, the correlation between the influence value and parameters of a single shim is analyzed, and the proper parameters, including the position, polarity, and size (radius and thickness), of the shimming pieces are well selected. Finally, the numbers and locations of the passive shims are optimized by mixed-integer linear programming method based on a modified central magnetic field. The optimized method is applied to a 0.5 T Bi-planar permanent magnet magnetic resonance imaging system, and the presented results prove the efficacy of this optimized passive shimming methodology.  相似文献   

8.
Dynamic B(0) shimming (DS) can produce better field homogeneity than static global shimming by dynamically updating slicewise shim values in a multislice acquisition. The performance of DS however is limited by eddy current fields produced by the switching of 2nd and 3rd order unshielded shims. In this work, we present a novel method of eddy field compensation (EFC) applied to higher order shim induced eddy current fields in multislice DS. This method does not require shim shielding, extra hardware for eddy current compensation or subject specific prescanning. The interactions between shim harmonics are modeled assuming steady state of the medium and long time constant, cross and self term eddy fields in a DS experiment and 'correction factors' characterizing the entire set of shim interactions are derived. The correction factors for a given time between shim switches are shown to be invariable with object scanned, shim switching pattern and actual shim values, allowing for their generalized prospective use. Phantom and human head, 2nd and 3rd order DS experiments performed without any hardware eddy current compensation using the technique show large reductions in field gradients and offsets leading to significant improvements in image quality. This method holds promise as an alternative to expensive hardware based eddy current compensation required in 2nd and 3rd order DS.  相似文献   

9.
Hyperpolarized noble gases (HNGs) provide exciting possibilities for MR imaging at ultra-low magnetic field strengths (<0.15 T) due to the extremely high polarizations available from optical pumping. The fringe field of many superconductive magnets used in clinical MR imaging can provide a stable magnetic field for this purpose. In addition to offering the benefit of HNG MR imaging alongside conventional high field proton MRI, this approach offers the other useful advantage of providing different field strengths at different distances from the magnet. However, the extremely strong field gradients associated with the fringe field present a major challenge for imaging since impractically high active shim currents would be required to achieve the necessary homogeneity. In this work, a simple passive shimming method based on the placement of a small number of ferromagnetic pieces is proposed to reduce the fringe field inhomogeneities to a level that can be corrected using standard active shims. The method explicitly takes into account the strong variations of the field over the volume of the ferromagnetic pieces used to shim. The method is used to obtain spectra in the fringe field of a high-field (1.89 T) superconducting magnet from hyperpolarized 129Xe gas samples at two different ultra-low field strengths (8.5 and 17 mT). The linewidths of spectra measured from imaging phantoms (30 Hz) indicate a homogeneity sufficient for MRI of the rat lung.  相似文献   

10.
Dynamic shim updating on the human brain   总被引:1,自引:0,他引:1  
Dynamic alteration of shim settings during a multi-slice imaging experiment can improve static magnetic-field homogeneity over extended volumes. In this report, a pre-emphasized dynamic shim updating (DSU) system capable of rapidly updating all non-degenerate zeroth through second-order shims is presented and applied to high-field multi-slice imaging studies on the human brain. DSU is utilized in both non-oblique and oblique slicing geometries while updating in-plane and through-slice shims. Image-based magnetic-field maps are used to quantify homogeneity improvements and comparisons are made on a slice-specific basis between static global shimming and increasing orders of shim inclusion utilized DSU. The influence of oblique slicing geometry on DSU-utilized global homogeneity is also quantified computationally. Finally, the effect of DSU on susceptibility artifact reduction in single-shot axial-sliced EPI is analyzed using experimental acquisitions.  相似文献   

11.
The first step in the process of shimming a magnetic field is to characterize it by obtaining a field map and decomposing that map into a convenient set of basis functions. The strength of each member of the set is then calculated. Finally, a set of correction elements which generate fields corresponding to the same spatial distribution as the basis functions is energized so that the sum of their fields and the error fields is substantially zero. The basis functions used typically are solutions to Laplace’s equation and have been shown to be very effective when the region of interest is substantially free space. This paper addresses issues associated with shimming the magnetic field in a region in which there is a distribution of materials with different susceptibilities and which therefore is not free space. In such a region, Laplace’s equation is no longer valid and in principle cannot be used to describe the magnetic field there. It is demonstrated that in spite of this, the same set of basis functions suffices for analyzing the field and the same set of elements suffices for correcting the field. The motivation for this study stems from the need to improve the magnetic field homogeneity when biological specimens are being imaged by magnetic resonance. In particular, this paper describes a study carried out by various simulated shimming strategies to improve the uniformity of the magnetic field over a multitissue model of susceptibility of the human head. The topics of magnetic susceptibility, the effect of shimming on MR images, shimming hardware and shimming methods are briefly reviewed. Two slices of the human head model were selected for detailed study, both offset inferior to the origin and including the base of the brain and the anterior sinus. The results of the study include comparisons between the strategies of global shimming, local slice-selective shimming and combinations of the two; the effects of shimming to various orders of spherical harmonics; and the effects of rotation and displacement of the head with respect to the shim frame of reference.  相似文献   

12.
A new approach to optimizing shim coil currents for magnetic resonance magnets is presented. The new approach orthogonalizes the shim coil gradients to allow a simple one-dimensional optimization for each orthogonalized "composite shim." The technique demands no specialized equipment, requiring only the acquisition of simple one-dimensional NMR spectra. Examples from two high-resolution NMR spectrometers are presented, where the shim currents found by the new algorithm provide higher resolution than was obtained by the spectrometer vendor's installation engineers using field-mapping techniques. The examples shown demonstrate the advantages of the technique for high-resolution NMR, but we expect the approach will also find application in a broad variety of areas including imaging and in vivo spectroscopy.  相似文献   

13.
A subject-specific local in vivo passive shimming method, focusing on the prefrontal and temporal regions, is proposed. The aim of the investigation is to show that subject variability exists in optimal passive shimming and that the proposed method can be effectively used to overcome these differences. A shimming structure capable of adjusting the position of the passive shims to within a millimeter resolution is built. The optimal shim positions for each individual subject are computed from obtained field map using a convex optimization algorithm. Passive shim experiments at predetermined fixed shim positions vs. individually adjusted shim positions were performed and compared. The results show that intersubject variability exists in the optimal shim positions and that the location-sensitive method proposed can be useful for improving main field homogeneity in vivo.  相似文献   

14.
The main magnetic fields of mobile nuclear magnetic resonance (NMR) magnets differ from those of conventional NMR and magnetic resonance imaging (MRI) magnets. In the Halbach magnet, the main field B 0 is perpendicular to the longitudinal axis, the symmetry of the current distribution with respect to the symmetry of the magnetic field differs from that in conventional target-field applications, and the current distribution on the coil surface cannot be expressed in terms of periodic basis functions. To obtain the winding pattern of the coil, an efficacious target-field approach. The surface of a coil is divided into small discrete elements, where each element is represented by a magnetic dipole. From the stream function of the elements, the resultant magnetic field is calculated. The optimization strategy follows an objective function defined by the power dissipation or efficiency of the coil. This leads to the optimum stream function on the coil surface, whose contour lines define the winding patterns of the coil. This paper shows winding patterns designed of shim coils for Halbach magnet and illustrates the craft of a shim coil using flexible printed circuit board. The performance of the coils is verified by simulating the fields they produce over the sensitive volume.  相似文献   

15.
For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylindrical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume.  相似文献   

16.
梯度和匀场线圈性能的好坏直接影响磁共振成像质量.常规线圈在成像过程中存在一些固有的不足,如产生的磁场形态单一、不灵活,需要的线圈种类较多,结构较复杂等.而新型矩阵梯度线圈可以较好地弥补这些缺点.本文首先介绍了矩阵梯度线圈的概念及其特性,然后根据结构和功能对其研究现状进行分类汇总,在此基础上对矩阵线圈未来的发展趋势进行分析.此外,本文还对矩阵梯度线圈的前期研究基础进行了介绍.  相似文献   

17.
强流回旋加速器综合试验装置的磁场测量与垫补   总被引:2,自引:0,他引:2  
强流回旋加速器综合试验装置的主体是一台紧凑型回旋加速器, 加速器主磁铁材料的不均匀性, 磁铁加工和安装的非理想因素将引起中心平面的磁场的非理想分布, 因此有必要对其中心平面的磁场进行测量和垫补. 本文主要讲述该综合试验装置的霍尔感应磁场测量系统的设计和使用;通过磁场测量数据分析进行镶条的再加工, 最终实现对等时性磁场和束流的纵向聚焦的垫补;研究与实践了一种对磁场一次谐波进行垫补的方法, 垫补的结果满足了设计的要求.  相似文献   

18.
Many technical and logistical questions must be addressed when planning the installation of an NMR imaging system. These considerations become particularly significant when the facility is being established within an existing medical center complex. This paper presents a report on the practical aspects and experience obtained in siting a 6-coil 0.15 T resistive magnet system. The topics discussed include: floor loading; ferromagnetic environment; the effect of iron on the magnet field strength and homogeneity characteristics; shimming procedures; temperature stability requirements; rf shielding; and effects of the magnetic field on common medical instrumentation and magnetic media. It was found that the field shift as a function of the distance of a steel mass from the center of the magnet exhibited an (1/r)5.2±0.5 to (1/r)4.2±0.3 dependence for axial and radial positions respectively which, as expected, is somewhat weaker than the (1/r)6 dependence expected by point dipole approximations. Field distortions caused by the presence of ferromagnetic material in radial positions may be essentially fully compensated with first order transverse shim coils (most conveniently, the x and y imaging gradient coils could be used). Axially distributed material requires, in addition to first order z-gradient correction, higher order axial shim compensation. The temperature stability of the magnet system over the scan period must be better than 0.2°C to insure that temperature-induced field fluctuations are less than the intrinsic static inhomogeneity: and, ideally, below 0.01°C to reduce these fluctuations to less than those caused by power supply instability.  相似文献   

19.
本文详细叙述了超导磁体的磁场分布和匀场线圈的设计。并对匀场电源、匀场线圈的精度和稳定性等要求作了估算。  相似文献   

20.
In vivo echo-planar imaging of rat spinal cord   总被引:1,自引:0,他引:1  
An integrated approach to echo-planar imaging of rat spinal cord in vivo with a small field of view (FOV) is presented. This protocol is based on a multishot interleaved echo-planar imaging (EPI) sequence and includes: 1) use of an inductively coupled implantable coil for improved signal-to-noise ratio (SNR); 2) three-dimensional (3D) automatic shimming of the magnetic field over the spinal cord; and 3) post-acquisition data processing using a multireference scan for minimizing image artifacts. Some of the practical issues in implementing this protocol are discussed. This imaging protocol will be useful in characterizing the spinal cord pathology using techniques that are otherwise time-consuming, such as diffusion tensor imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏