首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For immediate discrimination among isolated cells we propose a novel device and technique for isolation of cells and sequential detection of specific gene(s) within them by polymerase chain reaction (PCR). In this study, we isolated Salmonella enterica cells and detected the Salmonella-specific invA gene from isolated cells by PCR on a compact disk (CD)-shaped device. This device enabled liquid flow by centrifugal force without a micro pump, and was fabricated from silicon wafer and glass to avoid evaporation of a small amount of reagent. One device has 24 microchannels, and 313 microchambers integrated on each microchannel. One microliter of PCR mixture containing cells was separated into microchambers on the device at 5000 rpm for 30 s. Each microchamber contained approximately 1.5 nL PCR mixture. A Poisson distribution of S. enterica cells was observed for different densities of cell suspension. At 200 cells μL?1 of S. enterica or less, isolated single cells could be determined on the device by amplification of DNA of the invA gene; at 400 cells μL?1, chambers containing no, one, two, or three cells could be determined on the device. Selective detection of S. enterica was achieved by PCR from a mixture of S. enterica and Esherichia coli on the CD-shaped device.  相似文献   

2.
TD Rane  HC Zec  C Puleo  AP Lee  TH Wang 《Lab on a chip》2012,12(18):3341-3347
In this article we present a novel droplet microfluidic chip enabling amplification-free detection of single pathogenic cells. The device streamlines multiple functionalities to carry out sample digitization, cell lysis, probe-target hybridization for subsequent fluorescent detection. A peptide nucleic acid fluorescence resonance energy transfer probe (PNA beacon) is used to detect 16S rRNA present in pathogenic cells. Initially the sensitivity and quantification abilities of the platform are tested using a synthetic target mimicking the actual expression level of 16S rRNA in single cells. The capability of the device to perform "sample-to-answer" pathogen detection of single cells is demonstrated using E. coli as a model pathogen.  相似文献   

3.
4.
Integrated DNA extraction and amplification have been carried out in a microfluidic device using electro-osmotic pumping (EOP) for fluidic control. All the necessary reagents for performing both DNA extraction and polymerase chain reaction (PCR) amplification were pre-loaded into the microfluidic device following encapsulation in agarose gel. Buccal cells were collected using OmniSwabs [Whatman?, UK] and manually added to a chaotropic binding/lysis solution pre-loaded into the microfluidic device. The released DNA was then adsorbed onto a silica monolith contained within the DNA extraction chamber and the microfluidic device sealed using polymer electrodes. The washing and elution steps for DNA extraction were carried out using EOP, resulting in transfer of the eluted DNA into the PCR chamber. Thermal cycling, achieved using a Peltier element, resulted in amplification of the Amelogenin locus as confirmed using conventional capillary gel electrophoresis. It was demonstrated that the PCR reagents could be stored in the microfluidic device for at least 8 weeks at 4 °C with no significant loss of activity. Such methodology lends itself to the production of 'ready-to-use' microfluidic devices containing all the necessary reagents for sample processing, with many obvious applications in forensics and clinical medicine.  相似文献   

5.
《Analytical letters》2012,45(1):12-21
In this article, we introduce a novel real-time polymerase chain reaction (PCR) chip, which integrated the pretreatment of biological sample, the PCR reaction, and the real-time fluorescent detection. We have built a dam in the chamber of the chip and formed a crack underneath it to separate the white blood cell from the whole blood. After the lysis of white blood cells, which were separated from the whole blood, the real-time PCR reaction was produced by the integrated microheaters and resistance temperature detector (RTD), and the real-time fluorescent measurement was made in the identical chamber. Compared with conventional tubular PCR analysis, this chip-based PCR analysis can obtain more accurate results with a smaller amount of samples and reagents. We have designed the corresponding detection and control platform, which is composed of syringe pump module, temperature control module, and fluorescence sampling module. We also used the constructed chip for the examination of HLA-B27 related to ankylosing spondylitis, and the results show that the chip is available for the accurate and rapid analysis of HLA-B27 in whole blood.  相似文献   

6.
7.
Li H  Yeung ES 《Electrophoresis》2002,23(19):3372-3380
On-line capillary polymerase chain reaction (PCR) coupled with laser-induced fluorescence detection was successfully demonstrated for individual human cells. A single 50 num inner diameter (ID) fused-silica capillary served both as the reaction vessel and for isolating single cells. SYBR Green I dye was added into the reaction mixture for dynamic fluorescence labeling. Because of the small ID of the capillary, PCR-amplified DNA fragments from single cells were localized in the capillary, providing discrete product zones with concentrations at readily detectable levels. With selective primer design, only cells containing the DNA of interest were amplified. By counting the number of peaks in the capillary via electromigration past a detection window, the number of targeted cell templates could be determined. Identification of the 295 bp fragment beta-actin gene from individual human lymphoblast cell was demonstrated. Independent on-column cell counting provided positive correlation between the starting cell templates and the final PCR products. This opens up the possibility of highly selective and sensitive disease diagnosis at an early stage, when only a few cells in the population are defective.  相似文献   

8.
High-density microfluidic arrays for cell cytotoxicity analysis   总被引:12,自引:0,他引:12  
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl(2), NiCl(2), acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.  相似文献   

9.
Mao S  Gao D  Liu W  Wei H  Lin JM 《Lab on a chip》2012,12(1):219-226
In this work, we developed a microfluidic device for the imitation of drug metabolism in human liver and its cytotoxicity on cells. The integrated microfluidic device consists of three sections: (1) bioreactors containing poly(ethylene) glycol (PEG) hydrogel encapsulated human liver microsomes (HLMs); (2) cell culture chambers for cytotoxicity assay; and (3) integrated micro solid-phase extraction (SPE) columns to desalt and concentrate the products of enzymatic reaction. To verify the feasibility of the integrated microchip, we studied uridine 5'-diphosphate-glucuronosyltransferase (UGT) metabolism of acetaminophen (AP) and the cytotoxicity of products on HepG2 cells. The products of the reaction in one region of the device were injected into the cell culture chamber for cytotoxicity assay, while those in another region were directly detected online with an electrospray ionization quadrupole time-of-flight mass spectrometer (ESI-Q-TOF MS) after micro-SPE pre-treatment. Semiquantitative analysis achieved in the experiments could be related to the drug-induced HepG2 cell cytotoxicity. Total analysis time for one product was about 30 min and only less than 4 μg HLM protein was required for one reaction region. The results demonstrated that the established platform could be used to imitate drug metabolism occurring in the human liver, thereby replacing animal experiments in the near future. In addition, the integrated microchip will be a useful tool for drug metabolism studies and cytotoxicity assays, which are pivotal in drug development.  相似文献   

10.
A precolumn reaction chamber was integrated into a polyester microfluidic device with a miniaturized detection system. The reaction chamber was designed to be a zigzag channel, 70 microm in width, 8 mm in length, followed by a wider straight channel, 150 microm in width, 2 mm in length. The detection system is composed of an embedded light-emitting diode (LED), an integrated optical fiber, and a photomultiplier tube (PMT). A success in amino acid analysis using the integrated microchemical analysis device proved that the precolumn reaction chamber was compatible with the integrated detection system. Three kinds of amino acids, arginine, glycine, and phenylalanine, mixed and reacted with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) in the precolumn reaction chamber to produce fluorescent products, were separated by micellar eletrokinetic chromatography (MEKC) and detected by LED-excited fluorescence. The detection limits for arginine, glycine, and phenylalanine were 1, 1, and 0.5 mM, respectively, which can be improved by further optimizations of the reaction system and detection system.  相似文献   

11.
An integrated system of a silicon-based microfabricated polymerase chain reaction (microPCR) chamber and microfabricated electrophoretic glass chips have been developed. The PCR chamber was made of silicon and had aluminum heaters and temperature sensors integrated on the glass anodically bonded cover. Temperature uniformity in the reaction chamber was +/-0.3 degrees C using an improved novel "joint-heating" scheme. Thermal cycling was digitally controlled with a temperature accuracy of +/- 0.2 degrees C. Small operating volumes together with high thermal conductivity of silicon made the device well suited to rapid cycling; 16 s/cycle were demonstrated. For analysis of the PCR products, the chamber output was transferred to the glass microchip by pressure. Analysis time of PCR amplified genomic DNA was obtained in the microchip in less than 180 s. The analysis procedure employed was reproducible, simple and practical by using viscous sieving solutions of hydroxypropylmethylcellulose and dynamically coated microchip channels with poly(vinylpyrrolidone). DNA fragments that differ in size by 18 base pairs (bp) were resolved. Analysis of genomic male and female amplified DNA by microPCR was achieved in microchip, and application of the integrated microPCR-microchip for the identification of bird sex was tested. Genomic DNA samples from several bird species such as pigeon and chicken were analyzed. Hence, the system could be used as well to determine the sex of avian species.  相似文献   

12.
Zhu L  Zhang Q  Feng H  Ang S  Chau FS  Liu WT 《Lab on a chip》2004,4(4):337-341
A filter-based microfluidic device was combined with immunofluorescent labeling as a platform to rapidly detect microbial cells. The coin-sized device consisted of micro-chambers, micro-channels and filter weirs (gap = 1-2 microm), and was demonstrated to effectively trap and concentrate microbial cells (i.e., Cryptosporidium parvum and Giardia lamblia), which were larger in size than the weir gap. After sample injection, a staining solution containing fluorescently-labeled antibodies was continuously provided into the device (flow rate = 20 microl min(-1)) to flush the microbial cells toward the weirs and to accelerate the fluorescent labeling reaction. Using a staining solution that was 10 to 100 times more dilute than the recommended concentration used in a conventional glass method, those target cells with a fluorescent signal-to-noise ratio of 12 could be microscopically observed at single-cell level within 2 to 5 min prior to secondary washing.  相似文献   

13.
14.
15.
Huh YS  Choi JH  Huh KA  Kim KA  Park TJ  Hong YK  Kim do H  Hong WH  Lee SY 《Electrophoresis》2007,28(24):4748-4757
A microfluidic cell lysis chip equipped with a micromixer and SPE unit was developed and used for quantitative analysis of intracellular proteins. This miniaturized sample preparation system can be employed for any purpose where cell disruption is needed to obtain intracellular constituents for the subsequent analysis. This system comprises a magnetically actuated micromixer to disrupt cells, a hydrophobic valve to manipulate the cell lysate, and a packed porous polymerized monolith chamber for SPE and filtering debris from the cell lysate. Using recombinant Escherichia coli expressing intracellular enhanced green fluorescent protein (EGFP) and lipase as model bacteria, we optimized the cell disruption condition with respect to the lysis buffer composition, mixing time, and the frequency of the diaphragm in the micromixer, which was magnetically actuated by an external magnetic stirrer in the micromixer chamber. The lysed sample prepared under the optimal condition was purified by the packed SPE in the microfluidic chip. At a frequency of 1.96 Hz, the final cell lysis efficiency and relative fluorescence intensity of EGFP after the cell disruption process were greater than 90 and 94%, respectively. Thus, this microfluidic cell disruption chip can be used for the efficient lysis of cells for further analysis of intracellular contents in many applications.  相似文献   

16.
A valveless microdevice has been developed for the integration of solid phase extraction (SPE) and polymerase chain reaction (PCR) on a single chip for the short tandem repeat (STR) analysis of DNA from a biological sample. The device consists of two domains--a SPE domain filled with silica beads as a solid phase and a PCR domain with an ~500 nL reaction chamber. DNA from buccal swabs was purified and amplified using the integrated device and a full STR profile (16 loci) resulted. The 16 loci Identifiler? multiplex amplification was performed using a non-contact infrared (IR)-mediated PCR system built in-house, after syringe-driven SPE, providing an ~80-fold and 2.2-fold reduction in sample and reagent volumes consumed, respectively, as well as an ~5-fold reduction in the overall analysis time in comparison to conventional analysis. Results indicate that the SPE-PCR system can be used for many applications requiring genetic analysis, and the future addition of microchip electrophoresis (ME) to the system would allow for the complete processing of biological samples for forensic STR analysis on a single microdevice.  相似文献   

17.
The LacZ gene, which encodes Escherichia coli β‐galactosidase, is widely used as a marker for cells with targeted gene expression or disruption. However, it has been difficult to detect lacZ‐positive cells in living organisms or tissues at single‐cell resolution, limiting the utility of existing lacZ reporters. Herein we present a newly developed fluorogenic β‐galactosidase substrate suitable for labeling live cells in culture, as well as in living tissues. This precisely functionalized fluorescent probe exhibited dramatic activation of fluorescence upon reaction with the enzyme, remained inside cells by anchoring itself to intracellular proteins, and provided single‐cell resolution. Neurons labeled with this probe preserved spontaneous firing, which was enhanced by application of ligands of receptors expressed in the cells, suggesting that this probe would be applicable to investigate functions of targeted cells in living tissues and organisms.  相似文献   

18.
We describe initial studies utilizing three methods to detect differences in gene expression: (i) differential display with polyT-anchored primers; (ii) differential display with RNA arbitrarily primed polymerase chain reaction (RAP-PCR), and (iii) cDNA subtractive hybridization. Subtractive hybridization, which detects qualitative differences in gene expression, revealed no differences between a human cell line (MCF10A), originated by spontaneous immortalization of breast epithelial cells, and MCF10CA1 cells, a recently derived fully malignant, metastatic variant. The standard method of differential display with polyT anchored primers detected in excess of 100 differentially displayed bands but differential expression could seldom be verified by Northern blotting. However, RAP-PCR products frequently represent the coding region and fewer bands are detected. One gene of interest is a zinc finger protein which may be expressed more in the preneoplastic lesion-forming cells than in nonlesion-forming cells. Because most bands are not consistently differentially displayed among the variants of the MCF10 model, we suspect that point mutations rather than differential quantitative gene expression is responsible for some stage of progression. We propose that differential display of RAP-PCR products on nondenaturing gels might also detect point mutation differences.  相似文献   

19.
Chen X  Cui da F  Liu CC 《Electrophoresis》2008,29(9):1844-1851
Integrating cell lysis and DNA purification process into a micrototal analytical system (microTAS) is one critical step for the analysis of nucleic acids. On-chip cell lysis based on a chemical method is realized by sufficient blend of blood sample and the lyzing reagent. In this paper two mixing models, T-type mixing model and sandwich-type mixing model, are proposed and simulation of those models is conducted. Result of simulation shows that the sandwich-type mixing model with coiled channel performs best and this model is further used to construct the microfluidic biochip for on-line cell lysis and DNA extraction. The result of simulation is further verified by experiments. It asserts that more than 80% mixing of blood sample and lyzing reagent which guarantees that completed cell lysis can be achieved near the inlet location when the cell/buffer velocity ratio is less than 1:5. After cell lysis, DNA extraction by means of a solid-phase method is implemented by using porous silicon matrix which is integrated in the biochip. During continuous flow process in the microchip, rapid cell lysis and PCR-amplifiable genomic DNA purification can be achieved within 20 min. The potential of this microfluidic biochip is illustrated by pretreating a whole blood sample, which shows the possibility of integration of sample preparation, PCR, and separation on a single device to work as portable point-of-care medical diagnostic system.  相似文献   

20.
《Electroanalysis》2003,15(10):862-865
An integrated microfluidic device is used to derivatize, separate, and amperometrically detect amino acids and peptides in the presence of naphthalene‐2,3‐dicarboxyaldehyde (NDA). The integrated system offers a rapid (4 min) simultaneous measurements of 5 amino acids (Arg, Lys, Gly, Cys, PhenA) down to the 3.2 μM level in connection to a precolumn reaction chamber, an electrophoretic separation channel, and an end‐column thick‐film carbon‐electrode detector. The effect of the separation voltage, detection potential, reagent concentration, and other variables on the response is examined. Calibration and precision experiments indicate a linear and reproducible response. Applicability for the separation and detection of small peptides is demonstrated. Such on‐chip generation of electroactive products offers great promise for detecting other nonelectroactive analytes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏