首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Non-aqueous capillary electrophoresis with electrochemical detection (NACE-ED) was applied to the determination of cannabinoids in hair. The effect of different electrolyte compositions on the selectivity of the separation of tetrahydrocannabinol (THC), cannabinol (CBN), cannabidiol (CBD) and tetrahydrocannabinol carboxylic acid (THCA) was studied. Complete electrophoretic resolution was obtained using a strongly basic background electrolyte consisting of 5 mM sodium hydroxide dissolved in acetonitrile-methanol (1:1). Electrochemical detection yielded well defined signals in the oxidation mode. In order to obtain low limits of detection experimental parameters, which determine the sensitivity and the noise level, were optimized. A crucial parameter for sensitive measurements using a wall-tube flow cell as end-column detector is the distance between the capillary outlet and the working electrode. The highest signal-to-noise ratio using a 50 microm I.D. capillary was obtained at a distance of 25 microm. When the capillary outlet was moved away from the working electrode, thus reducing the strength of the separation field present at the working electrode, a large low frequency noise developed. This rise was attributed to disturbances of the hydrodynamic pattern in the flow cell. Analytical aspects such as sensitivity, reproducibility and selectivity were addressed in this work. The precision of NACE-ED regarding migration time and peak height for a sample containing 1 microg/ml THC was 0.4% and 1.1% (RSD), respectively (n=5). The calibration curve was linear for concentrations ranging between 0.1 and 10 microg/ml (r=0.998). The limit of detection for THC was 37 ng/ml, which is almost two orders of magnitude lower when compared with on-column UV detection. The method was evaluated using hair samples containing cannabinoids as sample material.  相似文献   

2.
Psurek A  Matysik FM  Scriba GK 《Electrophoresis》2006,27(5-6):1199-1208
Nonaqueous capillary electrophoresis with electrochemical detection (NACE-ED) was applied to the analysis of enkephalin peptides. The effect of different buffer compositions on the electrophoretic behavior of methionine enkephalin, leucine enkephalin, and [D-Ala2]-leucine enkephalin was studied. Separation of the protonated and the deprotonated peptides was obtained using ACN/methanol-based electrolyte systems. The electrochemical behavior of the enkephalins was studied by the capillary batch injection analysis technique. NACE-ED yielded well-defined signals in the oxidation mode only for the negatively charged analytes. The optimized BGE for the counterelectroosmotic separation consisted of 10 mM ammonium acetate in ACN/methanol (3:1 v/v). Using a platinum microdisk electrode set to an actual potential of +0.65 V detection limits in the submicromolar range were observed which are about one order of magnitude lower compared to UV detection. Problems concerning EOF instability and electrode fouling caused by water and other neutral sample impurities transported by the EOF can be avoided in the EOF-inverted mode using poly(ethylene glycol)-coated capillaries and an actual working electrode potential of +1.0 V. For the quantification of the enkephalins [D-Ala2]leucine enkephalin was used as internal standard. The practical utility for the determination of enkephalins in spiked plasma samples after SPE was demonstrated.  相似文献   

3.
A solid-phase microextraction fiber was prepared by polyaniline/graphene oxide nanocomposite as sorbent on the surface of a platinized stainless steel wire using electrospinning technique. The nanocomposite structure was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The polyaniline/graphene oxide nanocomposite fiber was used for the determination of nicotine from tobacco samples using headspace solid-phase microextraction method and gas chromatography–flame ionization detection. Influential experimental variables on the extraction efficiency of nicotine, such as extraction time and temperature, humidity and desorption conditions, were evaluated and optimized. Under the optimal experimental conditions? the limit of detection, linear dynamic range, intraday and inter-days precisions were found to be 0.01 μg g?1, 0.05–700 µg g?1 (R2?=?0.996), 6.9 and 8.1%, respectively. Comparison of the polyaniline/graphene oxide nanocomposite sorbent with polyaniline and commercial fibers shows longer durability, larger capacity and higher extraction efficiency. The polyaniline/graphene oxide nanocomposite fiber was successfully applied for the determination of nicotine in tobacco samples.  相似文献   

4.
A fully automated procedure is proposed for the Fourier transform infrared (FTIR) determination of nicotine in tobacco. The method is based on the on-line extraction of nicotine with CHCl3. Samples, weighed inside empty extraction cartridges, were humidified with NH3 and the cartridges were installed in a flow manifold in which they were extracted with 2 ml CHCl3 for 2 min, then 400 microliters of the extract were introduced into a micro-flow cell using a carrier of CHCl3 and the IR spectrum was registered continuously. The absorbance, in the wavenumber range 1334-1300 cm-1, was measured, obtaining a peak as a function of time. The area of this peak was interpolated on a calibration line established from standard solutions of nicotine in chloroform treated in the same way as samples. The method provided a limit of detection of 0.1 mg ml-1 nicotine, an RSD lower than 2% and a sampling frequency of the whole procedure of 6 h-1. Results obtained for natural samples of cut tobacco and cigar compared well with those obtained by a batch FTIR procedure, involving an off-line extraction with a total time of 16 min. However, for yellow tobacco cigarette, an on-line extraction time of 10 min was required to obtain a good recovery of nicotine.  相似文献   

5.
In this study, a sensitive and selective method based on liquid chromatography combined with diode array and tandem mass spectrometry detection (LC-DAD-MS/MS) was developed for the simultaneous quantitative determination of fenofibric acid, pravastatin and its main metabolites in human plasma. In this method, an automated solid-phase extraction (SPE) on disposable extraction cartridges (DECs) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-DAD-MS/MS system. On-line LC-DAD-MS/MS system using an atmospheric pressure ionization (TurboIonSpray) was then developed for the simultaneous determination of pravastatin, 3-hydroxy isomeric metabolite (3-OH metab), pravalactone and fenofibric acid. The separation is obtained on an endcapped dodecyl silica based stationary phase using a mobile phase consisting of a mixture of acetonitrile, methanol and 5mM ammonium acetate solution (30:30:40, v/v/v). Sulindac and triamcinolone were used as internal standards (ISs). The detection of the fenofibric acid and sulindac was achieved by means of a DAD system. The MS/MS ion transitions monitored were m/z 442.2-->269.1, 442.2-->269.1, 424.3-->183.0 and 435.2-->397.2 for pravastatin, 3-OH metab, pravalactone and triamcinolone, respectively. The method was validated regarding stability, selectivity, extraction efficiency, response function, trueness, precision lower limit of quantitation and matrix effect. The limits of quantitation (LOQs) were around 0.50 ng/ml for pravastatin, 0.25 ng/ml for 3-OH metab, 0.05 ng/ml for pravalactone and 0.25 microg/ml for fenofibric acid.  相似文献   

6.
The present study is concerned with the application of nonaqueous capillary electrophoresis (NACE) with electrochemical detection (ED) to the separation and quantitative determination of hydrazine (Hy) and its methyl derivatives. The best performance of NACE-ED was found when using 4 mM sodium acetate/10 mM acetic acid/methanol: acetonitrile = 1:2 as the running buffer, with a bare platinum working electrode set at +1.0 V in an end-column amperometric detection cell. The choice and ratio of suitable solvents for the separation and injection media played an essential role for the performance characteristics of the method. The limits of detection for Hy, methylhydrazine, symmetrical dimethylhydrazine, and unsymmetrical dimethylhydrazine were 5, 2, 12, and 1 ng/mL, respectively. This is between one and two orders of magnitude lower than that achieved by previously reported CE-ED methods in aqueous buffer systems in conjunction with various types of chemically modified electrodes. The practical utility of the new NACE-ED methodology is demonstrated in terms of the determination of traces of Hys in spiked environmental samples containing a wide range of explosives and related compounds.  相似文献   

7.
A method to determine 21 organochlorine pesticides in vegetation samples using microwave-assisted extraction (MAE) is described and compared with Soxhlet extraction. Samples were extracted with hexane–acetone (1:1, v/v) and the extracts were cleaned using solid-phase extraction with Florisil and alumine as adsorbents. Pesticides were eluted with hexane–ethyl acetate (80:20, v/v) and determined by gas chromatography and electron-capture detection. Recoveries obtained (75.5–132.7% for Soxhlet extraction and 81.5–108.4% for MAE) show that both methods are suitable for the determination of chlorinated pesticides in vegetation samples. The method using microwave energy was applied to grass samples from parks of A Coruña (N.W. Spain) and to vegetation from the contaminated industrial area of Torneiros (Pontevedra, N.W. Spain).  相似文献   

8.
为准确测定烟草浸膏中烟碱含量,以2-甲基喹啉为内标建立了测定烟草浸膏中烟碱的气相色谱-氢火焰离子化法(GC-FID),并测定了5个烟草浸膏样品.结果表明,方法的回收率为95.00%~98.58%,检出限为0.27 mg/g,定量限为0.89 mg/g.所测烟草浸膏中烟碱的质量分数在19.66~54.97 mg/g之间.方法简单、灵敏、准确,适用于烟草浸膏中烟碱的测定.  相似文献   

9.
The pressurized liquid extraction (PLE) followed by dispersive liquid–liquid micro‐extraction (DLLME) has been developed for extraction of volatile components in tobacco. 35 volatile components were detected by gas chromatography mass spectrometry (GC‐MS). Methanol–methyl tert‐butyl ether (MTBE) (8:2, v/v) was selected as PLE extraction solvent. The optimized DLLME procedure, 3 mL of pure water and 1.0 mL tobacco extract solution, 40 μL of chloroform as extraction solvent, 0.5 mL of acetonitrile as disperser solvent, was validated. Under the optimum conditions, the enrichment factors were in the range of 96‐159. The limits of detection were between 0.14 and 0.33 μg/kg. The repeatability of the proposed method, expressed as relative standard deviation, varied between 4.3 and 7.5% (n = 6). The recoveries of the analytes evaluated by fortification of tobacco samples were in the range of 84.7‐96.4%. Compared with the conventional sample preparation method for determination of volatile components in tobacco, the proposed method was quick and easy to operate, and had high‐enrichment factors and low consumption of organic solvent.  相似文献   

10.
通过优化实验条件,选择洗脱温度80℃、加热时间5min、萃取压力10.4MPa、洗脱溶剂为300mL的甲醇/乙酸(90∶10,V/V),静态萃取时间8min、吹扫时间100s,对1.000g尼古丁印迹聚合物中的模板分子进行连续6次的萃取洗脱,洗脱效率达94.2%,模板渗漏量仅为9.8μg/L,萃取时间<70min。将2000mg洗脱后的印迹聚合物颗粒装填于3mL的聚丙烯固相萃取小柱中,用10mL甲醇/乙酸(90∶1,V/V)淋洗小柱,用高效液相色谱检测淋洗液中的尼古丁,获得模板的渗漏量为9.8μg/L。  相似文献   

11.
张佳杰  孟子晖  薛敏  魏天晔 《色谱》2018,36(11):1081-1087
烟碱是评价烟草及其制品的感官品质及内在质量的重要指标,同时也是监测食品、环境及人体中尼古丁暴露程度的关键因素。烟碱所在基质复杂,样品多样,针对不同检测环境及要求选择合适高效的分析方法对成功测定烟碱含量至关重要。该文介绍了测定烟草及生物样品中烟碱含量的样品前处理技术(固相/液相微萃取技术和分子印迹法)和常用的检测方法(分光光度法、液相色谱法、气相色谱法、毛细管电泳法、电化学法),评述了每种方法的适用范围、应用实例和研究进展,并讨论了各种检测方法的灵敏度、准确性和检测效率等。  相似文献   

12.
A selective and sensitive method for the determination of piritramide in human plasma is described. A 1-ml aliquot of plasma was extracted with 10 ml of hexane-isoamyl alcohol (99.5:0.5, v/v) (extraction efficiency 86%) after addition of 50 microliters of 2 M ammonia and 20 microliters of aqueous strychnine solution (100 ng per 10 microliters) as internal standard. Gas chromatography was performed with J&W DB-1, 30 m x 0.53 mm I.D. separation column, film thickness 1.5 microns, using an nitrogen-phosphorus-sensitive detector. The assay was linear in the concentration range 3.75-2250 ng/ml (r = 0.999), with a lower limit of detection of 1-2 ng/ml. The precision was determined using spiked plasma samples (10 and 50 ng/ml), with coefficients of variation of 3.5 and 3.1% (intra-day; n = 5) and 4.6 and 4.1% (inter-day; n = 4). In the range 3.75-150 ng/ml, the accuracy of the assay was 3.36%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or post-operative analgesia.  相似文献   

13.
We describe a high-performance liquid chromatographic method with electrochemical detection for quantifying pyronaridine in rhesus monkey (Macaca mulata) blood and urine samples. The detection limit is 20 ng/ml at a signal-to-noise ratio of 4 in 0.5-ml samples of blood or urine. Blood analysis includes a liquid-liquid extraction and a subsequent solid-phase extraction that removes an interferent present in blood. For urine, a back-extraction is substituted for the solid-phase extraction step. The method uses an analogue of amodiaquine as internal standard, a 10-microns rigid macroporous styrene-divinylbenzene copolymer column and a mobile phase of 1% (v/v) triethylamine in methanol-water (34:66, v/v). The method was applied to samples of blood and urine from a monkey after a single intramuscular dose of pyronaridine tetraphosphate (160 mg as base).  相似文献   

14.
Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ≤9.4 and ≤9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.  相似文献   

15.
Quantitation of nicotine in tobacco products by capillary electrophoresis   总被引:3,自引:0,他引:3  
A simple and rapid capillary electrophoresis (CE) method was developed for the quantitation of nicotine in commercial tobacco products. The method involves a 6 min run at 30 kV, using a 50 mM phosphate buffer (pH 2.5), paraquat as internal standard, and UV detection at 260 nm. Nicotine was extracted from tobacco products in <15 min. Recoveries from spiked extracts were >95%, and the extraction efficiencies of water, 1 M HCI, 1 M acetic acid, 5 mM phosphate buffer (pH 2.5), and 1% triethanol amine were similar. Nicotine concentrations in 67 samples of cigarettes, cigars, and bidis varied between 0.37 and 2.96% (w/w). An established gas chromatography/mass spectrometry method using toluene extraction consistently yielded lower nicotine values than the CE method. Experimental evidence suggests that this is due to insufficient extraction of nicotine by toluene.  相似文献   

16.
An isocratic reversed-phase ion-pair liquid chromatographic method for the determination of tianeptine and its two main metabolites in plasma, urine and tissues, using an internal standard, is reported. The influence of two stationary phases on the retention of the drugs was studied. The drugs were extracted as ion pairs, using a heptane-octanol-tetraheptylammonium bromide mixture (98:2:0.5, v/v/w) as extraction solvent. This extraction procedure yielded plasma drug recoveries of greater than 60% and allowed UV detection at 220 nm without interference from endogenous components of plasma, urine or tissues. Linear standard curves up to 1.00 micrograms/ml and drug determination down to 0.01 microgram/ml were observed. This method has been successfully applied to the analysis of human plasma and urine samples and of encephales from tianeptine-dosed rats.  相似文献   

17.
A liquid chromatographic-mass spectrometric method for the simultaneous determination of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma was developed and validated. Analytes and deuterated internal standards were extracted from human plasma using solid-phase extraction and analyzed by liquid chromatography/atmospheric pressure chemical ionization-mass spectrometric detection with selected ion monitoring (SIM). Limits of detection and quantification were 1.0 and 2.5 ng/ml, respectively, for all analytes. Linearity ranged from 2.5 to 500 ng/ml of human plasma using a weighting factor of 1/x; correlation coefficients for the calibration curves were > 0.99. Intra- and inter-assay precision and accuracy were < 15.0%. Recoveries were 108.2-110.8% nicotine, 95.8-108.7% cotinine, 90.5-99.5% trans-3'-hydroxycotinine, and 99.5-109.5% norcotinine. The method was also partially validated in bovine serum, owing to the difficulty of obtaining nicotine-free human plasma for the preparation of calibrators and quality control (QC) samples. This method proved to be robust and accurate for the quantification of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma collected in clinical studies of acute nicotine effects on brain activity and on the development of neonates of maternal smokers.  相似文献   

18.
采用QuEChERS前处理方法,建立了气相色谱-负化学电离源-飞行时间质谱(GC-NCI-TOF-MS)检测烟草中10种有机氯农药残留的分析方法。样品采用乙酸乙酯-正己烷(1 : 1, v/v)溶液提取,提取液经N-丙基乙二胺(PSA)、无水硫酸镁分散固相萃取净化,用GC-NCI-TOF-MS检测分析。根据有机氯化合物特征离子的精确质量数、同位素离子峰簇、碎片离子丰度比和保留时间对目标物定性鉴定,外标法定量。10种有机氯农药的线性关系良好,相关系数 (r2)均大于0.997;相对标准偏差小于6.5%;检出限为0.04~0.80 μ g/kg;加标回收率为77.2%~93.0%。该方法简单快速、灵敏度高、准确性好,适用于烟草中有机氯农药残留的定性分析和定量检测。  相似文献   

19.
A rapid and sensitive method for the determination of domperidone in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometry detection. The samples were rendered basic with 1 M Na2CO3 and the domperidone extracted using tert.-butyl methyl ether, followed by back-extraction into formic acid (2% in water). Chromatography was performed on a Phenomenex Luna C8 (2), 5 microm, 150x2 mm column with a mobile phase consisting of acetonitrile-0.02% formic acid (300:700, v/v), delivered at 0.2 ml/min. Detection was performed using an Applied Biosystems Sciex API 2000 mass spectrometer set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery of domperidone was +/- 100%, with a lower limit of quantification set at 0.189 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric detection resulting in a rapid (extraction and chromatography) and sensitive method for the determination of domperidone in human plasma, which is more sensitive than previously described methods.  相似文献   

20.
A sensitive and selective high-performance liquid chromatographic method with fluorescence detection is described for the determination of AJ-3941 (I), a possible agent for the treatment of cerebrovascular disorders, in plasma and brain tissue. A simple hexane extraction was used for plasma, and for brain homogenate the hexane extract was further purified by solid-phase extraction. The determination limit was ca. 3 ng/ml for both plasma (0.5 ml) and 10% (w/v) brain homogenate (1 ml). The method was applied to the determination of I in plasma and brain samples of experimental animals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号