共查询到18条相似文献,搜索用时 100 毫秒
1.
2.
氢化物发生-电感耦合等离子体原子发射光谱法测定钢中微量砷、锑、铋 总被引:1,自引:0,他引:1
样品经盐酸-硝酸(3+1)溶液溶解,高氯酸冒烟后,用氢化物发生-电感耦合等离子体原子发射光谱法测定钢中微量砷、锑和铋的含量。研究了介质的酸度、硼氢化钾的浓度对3种元素信号强度的影响,并考察了其他元素对3元素测量的化学干扰。选择波长为189.042,217.58,223.06nm的3条谱线依次作为测定砷、锑和铋的分析线。砷、锑和铋的检出限(3s/k)分别为0.48,3.5,2.0μg.L-1。应用此法测定2个标准样品(GSBH40064-93和BH4265)中3种元素的含量,测定值与标准值相一致。 相似文献
3.
氢化物发生电感耦合等离子体原子发射光谱法同时测定水和生物样品中… 总被引:13,自引:0,他引:13
研究了一种小型同心氢化物发生配置一个气液分离器后与多道ICP-AES联用,同时测定水和生物样品中砷、铋、锑、硒的方法。检出限为砷0.4μg/L,铋0.5μg/L,锑1.4μg/L,硒0.5μg/L,相对标准偏差为砷2.7%,铋1.5%,锑2.7%,硒1.9%。用本法测定美国和国家标准物质中的氢化元素,结果满意。 相似文献
4.
氢化物发生-电感耦合等离子体原子发射光谱法同时测定锑锭中氢化物元素和非氢化物元素 总被引:1,自引:0,他引:1
运用改进的同心喇叭口双溶液管雾化器,采用连续氢化物发生法,在酸性介质中,对锑锭样品溶液既发生雾化作用,又对可形成氢化物的元素(As、Se、Pb)发生氢化作用,使它们的发射强度得到显著提高,而对非形成氢化物的元素(Fe、Cu)的发射强度基本不受影响,利用ICP-AES同时测定锑锭中形成氢化物的元素和非形成氢化物的元素。对实际样品进行对比检测,结果令人满意。 相似文献
5.
氢化物发生-电感耦合等离子体原子发射光谱法测定环境样品中痕量硒 总被引:3,自引:0,他引:3
环境样品经硝酸-过氧化氢-氢氟酸体系微波消解,利用自制雾化器采用氢化物发生-电感耦合等离子体原子发射光谱法测定其中的痕量硒。选择硒的分析谱线为196.090nm。硒的质量浓度在32μg·L-1以内与其发射强度呈线性关系,方法的检出限(3S/N)为0.71μg·L-1。方法应用于国家标准物质中硒的的测定,测定值与认定相符,加标回收率在85.8%~102%之间,测定值的相对标准偏差(n=6)在0.38%~2.3%之间。 相似文献
6.
氢化物发生-电感耦合等离子体原子发射光谱法测定血样中硒含量 总被引:1,自引:0,他引:1
样品经高氯酸-硝酸(1+4)混合溶液消化,以盐酸作为预还原剂,用氢化物发生-电感耦合等离子体原子发射光谱法测定全血中硒。在6mol.L-1盐酸溶液中加入溶于20g.L-1氢氧化钠溶液的5g.L-1硼氢化钠溶液使与溶液中硒离子反应生成氢化物。方法的检出限(3s/k)为1.8μg.L-1。应用此法测定2份血液样品中硒含量,方法的回收率在94.9%~107%之间,测定值的相对标准偏差(n=10)小于3%。 相似文献
7.
流动注射-氢化物发生-电感耦合等离子体原子发射光谱法测定矿石中的砷、锑、铋 总被引:2,自引:0,他引:2
本文将流动注射-氢化物-ICP/AES 技术应用于矿石中痕量砷、锑、铋的测定。结果表明,本法具有分析速度快(60样/小时),灵敏度高(As、Sb、Bi 的测定下限达μg/g 级),精度好及操作简便等优点。 相似文献
8.
9.
用新型氢化物发生喇叭口Ⅱ型同心雾化器替代Meinhard同心雾化器,溶液雾化为气溶胶和氢化物发生反应生成氢化物气体就可以在雾化系统中同时进行,选用L-巯基丙氨酸(L-cysteine)和硫脲(thiourea)作为基体铜的掩蔽剂,无需分离基体铜,实现了电感耦合等离子体原子发射光谱(ICP-AES)同时测定纯铜样品中氢化物和非氢化物形成元素的目的。研究了酸度、NaBH4的浓度、载气流速及清洗时间对氢化物形成元素的影响,考察了铜基体对氢化物形成元素的化学干扰情况。用本方法测定了纯铜标准样品(NIST SRM400),结果令人满意。在1000mg/L纯铜样品溶液中,其氢化物形成元素As、Bi、Sb、Sn、Se和Te的检出限分别为0.08、0.15、0.10、0.17、0.21和0.23μg/L。 相似文献
10.
氢化物连续发生电感耦合等离子体原子发射光谱法测定高纯铟中砷锑锡 总被引:7,自引:0,他引:7
采用氢化物连续发生与电感耦合等离子体原子发射光谱联用技术对高纯铟中砷、锑和锡的测定进行了研究。考察了酸介质及其浓度、硼氢化钠浓度及还原剂等对信号强度的影响,砷、锑和锡的检出限分别为0.13,0.017和0.12μg·g-1,回收率分别为108%,93.1%和91.1%。 相似文献
11.
《Analytical letters》2012,45(5):942-953
Hydride generation from solution containing As(III), Bi(III), and Sb(III) by means of different borane reductants and acids using inductively coupled plasma optical emission spectrometry as a detection system was investigated. The As, Bi, Sb, B, C, H, and N lines as well as the OH and CN molecules were recorded. Their intensities in relation to hydride formation conditions were measured. Effects of the HCl, CH3COOH, and C6H8O7 acids as well as the NaBH4, H3B-NH(CH3)2, and H3B-NH2C(CH3)3 reductants on efficiency of the As, Sb, and Bi hydride generation were investigated and discussed. Influence of hydride generation conditions on plasma was studied. 相似文献
12.
The present work describes a study on the determination of arsenic in plant samples with hydride generation coupled with an
axial view inductively coupled plasma atomic emission spectrometer. The accuracy of the measurements was not affected by elements
present in high concentrations in the plant matrix (K, Ca, Mg, and P). Interference from transition metals was not observed
either. When using real samples (maize and oak leaves) with standard additions, a decrease in the recoveries was sometimes
observed when using KI to reduce As(V) to As(III), which reached 13.5% in the most unfavourable case. The use of a mixture
containing KI and ascorbic acid is recommended. The accuracy of the method was verified using three certified reference materials.
No statistically significant differences were observed between the measured concentrations and the certified values. The optimized
method was found to be sensitive (detection limit: 0.1 μg L−1) and reliable. The results obtained under routine conditions over a period of several months also demonstrated its reproducibility. 相似文献
13.
14.
15.
氢化物发生—电感耦合等离子体原子发射光谱法测定环境样品中痕量铅 总被引:4,自引:0,他引:4
提出了以重铬酸钾-铁氰经钾为氧化剂的铅氢化物发生氧化还原体系。采用连续氢化物发生器,对电感耦合等离子体原子发射光谱法,测定痕量铅的条件进行了研究。选定条件下,以02%硫氰酸钾-0.45草酸为干扰抑制剂,测得铅的检出限为0.09μg/L,相对标准偏差为0.49%。对环境标准物质进行分析,结果令人满意。 相似文献
16.
电感耦合等离子体原子发射光谱分析研究进展 总被引:3,自引:0,他引:3
魏良江 《广东微量元素科学》2010,17(4):1-8
介绍了近年来国内在电感耦合等离子体原子发射光谱分析(ICP-AES)有关基础理论、仪器设备、进样技术和ICP-AES应用方面取得的研究进展。引用文献76篇。 相似文献
17.
建立了电感耦合等离子体原子发射光谱(ICP-AES)法测定锌锭中的Pb、Cd、Fe、Cu、Sn 5种杂质元素的方法。样品用硝酸(1+1)溶解后,在稀硝酸介质中利用电感耦合等离子体原子发射光谱仪测定其中Pb、Cd、Fe、Cu、Sn的含量,测定的相对标准偏差(RSD,n=3)小于1.7%,对锌光谱标样BYG0505的测定结果与标准值基本一致。实现了对锌锭中多种杂质元素的简便、快速、准确的同时测定。 相似文献
18.
韩晓 《中国无机分析化学》2017,7(1):69-71
用HNO_3-HClO_4(4∶1)溶解硒片,电感耦合等离子体原子发射光谱(ICP-AES)法测定其中的硒、铁、钙和锌,实验表明硒片中硒、铁、钙和锌的含量较为丰富,与外包装承诺的含量一致。方法灵敏可靠,测量相对标准偏差3%,加标回收率在96.5%~101%,实验结果为探讨硒片对人体的保健作用提供了参考数据。 相似文献