首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An on-line Hg reduction technique using stannous chloride as the reductant was applied for accurate and precise mercury isotope ratio determinations by multi-collector (MC)-ICP/MS. Special attention has been paid to ensure optimal conditions (such as acquisition time and mercury concentration) allowing precision measurements good enough to be able to significantly detect the anticipated small differences in Hg isotope ratios in nature. Typically, internal precision was better than 0.002% (1 RSE) on all Hg ratios investigated as long as approximately 20 ng of Hg was measured with a 10-min acquisition time. Introducing higher amounts of mercury (50 ng Hg) improved the internal precision to <0.001%. Instrumental mass bias was corrected using 205Tl/203Tl correction coupled to a standard-sample bracketing approach. The large number of data acquired allowed us to validate the consistency of our measurements over a one-year period. On average, the short-term uncertainty determined by repeated runs of NIST SRM 1641d Hg standard during a single day was <0.006% (1 RSD) for all isotope pairs investigated (202Hg/198Hg, 202Hg/199Hg, 202Hg/200Hg, and 202Hg/201Hg). The precision fell to <0.01% if the long-term reproducibility, taken over 11 months (over 100 measurements), was considered. The extent of fractionation has been investigated in a series of sediments subject to various Hg sources from different locations worldwide. The ratio 202Hg/198Hg expressed as δ values (per mil deviations relative to NIST SRM 1641d Hg standard solution) displayed differences from +0.74 to −4.00‰. The magnitude of the Hg fractionation per amu was constant within one type of sample and did not exceed 1.00‰. Considering all results (the reproducibility of Hg standard solutions, reference sediment samples, and the examination of natural samples), the analytical error of our δ values for the overall method was within ±0.28‰ (1 SD), which was an order of magnitude lower than the extent of fractionation (4.74‰) observed in sediments. This study confirmed that analytical techniques have reached a level of long-term precision and accuracy that is sufficiently sensitive to detect even small differences in Hg isotope ratios that occur within one type of samples (e.g., between different sediments) and so far have unequivocally shown that Hg isotope ratios in sediments vary within approximately 5‰.  相似文献   

2.
The development and application of a calibration strategy for routine isotope ratio analysis by multi-collector inductively coupled plasma mass spectrometry (ICP-MS) is described and assessed. Internal standardization was used to account for the mass dependant determinate error (mass bias). The general solution for polynomial isotope ratio mass bias functions for use with internal standardization and isotope ratio measurements by multi-collector inductively coupled plasma mass spectrometry was derived. The resulting linear isotope ratio mass bias function was demonstrated to be mathematically consistent and experimentally realistic for the analysis of acidified aqueous solutions of analyte and internal standard elements (clean solutions) by multi-collector inductively coupled plasma mass spectrometry.  相似文献   

3.
4.
Elwaer N  Hintelmann H 《Talanta》2008,75(1):205-214
The performance of two different types of inductively coupled plasma mass spectrometry (ICP-MS) instruments for resolving spectral overlaps on Se isotopes was compared by means of selenium isotopic ratio measurements. Examined were a quadrupole-based, hexapole collisions cell CC-ICP-MS and a double-focusing sector field SF-ICP-MS. Due to the importance of precise and accurate isotope ratio determination in environmental, clinical and nutritional studies, a thorough investigation of the critical instrumental parameters of each technique was performed. A hydride generation system was coupled with SF-ICP-MS to maintain high signal-to-noise ratios (S/N) at high mass resolution. However, 80Se+ was not completely separated from the argon dimer (40)Ar2+ at m/z=80, even in high-resolution mode. The same hydride generation system was coupled to a collision cell instrument and it was found that argon dimers are significantly reduced using a mixture of H2 and He gas with the cell. A lower mass bias of 2.5% per amu was determined for measured Se isotopes using the SF-ICP-MS instrument compared 3.6% observed for the CC-ICP-MS instrument. Under optimized conditions, the precision for Se isotope ratio measurements of both instruments was evaluated and compared measuring NIST-3149 Se standard solution. On average, the uncertainty determined by repeated measurements over the span of three individual measuring sessions in a period of 3 weeks ranged from 0.06% to 0.15% and 0.09% to 0.30% R.S.D. for the various isotope ratios using the CC-ICP-MS and SF-ICP-MS instrument, respectively. The detection limits (3) for total Se were determined by measuring 82Se and found to be 1.7 and 4.0 ng L(-1) for the CC-ICP-MS and SF-ICP-MS, respectively.  相似文献   

5.
Sahoo YV  Nakai S  Ali A 《The Analyst》2006,131(3):434-439
Tungsten isotope composition of a sample of deep-seated rock can record the influence of core-mantle interaction of the parent magma. Samples of kimberlite, which is known as a carrier of diamond, from the deep mantle might exhibit effects of core-mantle interaction. Although tungsten isotope anomaly was reported for kimberlites from South Africa, a subsequent investigation did not verify the anomaly. The magnesium-rich and calcium-rich chemical composition of kimberlite might engender difficulty during chemical separation of tungsten for isotope analyses. This paper presents a simple, one-step anion exchange technique for precise and accurate determination of tungsten isotopes in kimberlites using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Large quantities of Ca and Mg in kimberlite samples were precipitated and removed with aqueous H(2)SO(4). Highly pure fractions of tungsten for isotopic measurements were obtained following an anion exchange chromatographic procedure involving mixed acids. That procedure enabled efficient removal of high field strength elements (HFSE), such as Hf, Zr and Ti, which are small ions that carry strong charges and develop intense electrostatic fields. The tungsten yields were 85%-95%. Advantages of this system include less time and less use of reagents. Precise and accurate isotopic measurements are possible using fractions of tungsten that are obtained using this method. The accuracy and precision of these measurements were confirmed using various silicate standard rock samples, JB-2, JB-3 and AGV-1.  相似文献   

6.
7.
A novel analytical technique for isotopic analysis of dissolved and particulate iron (Fe) from various marine environments is presented in this paper. It combines coprecipitation of dissolved Fe (DFe) samples with Mg(OH)2, and acid digestion of particulate Fe (PFe) samples with double pass chromatographic separation. Isotopic data were obtained using a Nu Plasma MC-ICP-MS in dry plasma mode, applying a combination of standard-sample bracketing and external normalization by Cu doping. Argon interferences were determined prior to each analysis and automatically subtracted during analysis. Sample size can be varied between 200 and 600 ng of Fe per measurement and total procedural blanks are better than 10 ng of Fe. Typical external precision of replicate analyses (1S.D.) is ±0.07‰ on δ56Fe and ±0.09‰ on δ57Fe while typical internal precision of a measurement (1S.E.) is ±0.03‰ on δ56Fe and ±0.04‰ on δ57Fe. Accuracy and precision were assured by the analysis of reference material IRMM-014, an in-house pure Fe standard, an in-house rock standard, as well as by inter-laboratory comparison using a hematite standard from ETH (Zürich). The lowest amount of Fe (200 ng) at which a reliable isotopic measurement could still be performed corresponds to a DFe or PFe concentration of ∼2 nmol L−1 for a 2 L sample size. To show the versatility of the method, results are presented from contrasting environments characterized by a wide range of Fe concentrations as well as varying salt content: the Scheldt estuary, the North Sea, and Antarctic pack ice. The range of DFe and PFe concentrations encountered in this investigation falls between 2 and 2000 nmol L−1 Fe. The distinct isotopic compositions detected in these environments cover the whole range reported in previous studies of natural Fe isotopic fractionation in the marine environment, i.e. δ56Fe varies between −3.5‰ and +1.5‰. The largest fractionations were observed in environments characterized by redox changes and/or strong Fe cycling. This demonstrates the potential use of Fe isotopes as a tool to trace marine biogeochemical processes involving Fe.  相似文献   

8.
9.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples.  相似文献   

10.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples. Received: 1 December 1998 / Revised: 25 January 1999 / Accepted: 31 January 1999  相似文献   

11.
为推动锶同位素在水产品溯源中的应用,本文建立了基于电感耦合等离子体质谱法(ICP-MS)测定水产品中锶同位素比值的分析方法。水产品组织经冻干研磨和微波消解后,用ICP-MS测定样品溶液中的锶同位素比值,并采用标准品-样品-标准品交叉测量方法降低质量歧视效应的影响。结果表明,通过稀释样品消解溶液,将总锶浓度控制在70-100 μg/L,并与80 μg/L的锶同位素标准品溶液进行交叉测量,可准确校正质量歧视效应;84Sr/86Sr、87Sr/86Sr和88Sr/86Sr的日内精密度分别为0.06%、0.03%和0.03%,日间精密度分别为0.08%、0.04%和0.03%;按照所建立的方法测定大虾和扇贝生物成分分析标准物质的锶同位素比值,84Sr/86Sr、87Sr/86Sr和88Sr/86Sr的相对标准偏差均低于0.1%。该方法前处理简单快捷并且测量精密度高,可为锶同位素比值测定并进一步应用于水产品溯源研究提供技术支撑。  相似文献   

12.
Isotope ratio measurements are found to have systematic bias when using the analog detection mode on an inductively coupled plasma time-of-flight (TOF) mass spectrometer. This bias is dependent upon the value of the ratio, the intensity of the signal, and the gain of the electron multiplier tube. The error should not appear if ion counting is employed instead of analog detection, although analog detection with time-of-flight has other distinct advantages. The cause of this isotope ratio inaccuracy is rooted in disproportionate recording of the analog signal because of the need to filter out noise by blocking analog signals below a threshold voltage. This attenuates smaller signals to a greater degree than larger signals. This variable “detection efficiency” causes a larger systematic error in the isotopic ratio as the isotopic abundances become more disparate. Ratios close to unity are generally accurate within the precision of the measurement. The use of an increased gain on the detector leads to improved ratio accuracy, but at the cost of decreased detector lifetime. This research presents a method of analyzing solutions using natural, known isotopic ratios to produce an efficiency correction curve. The average error of several isotope ratios for a 500 ng/mL solution of various elements with ratios between 3.4 and 10 was found to be 6.5% without correction, 3.0% with increased detector gain, 1.1% with efficiency correction and 0.6% with both increased gain and efficiency correction.  相似文献   

13.
A second-generation multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) was applied to lithium isotopic measurements. The high sensitivity of the ICP-MS enabled high precision (±0.82‰, 2σ) analyses with small amount of Li (∼45 ng Li). A single-step column separation protocol was established with which rapid purification of lithium from rock solutions can be carried out with reduced blank (<10 pg). The influence of potential sources of error for acquisition of lithium isotopic data introduced during the separation, such as matrix effects and isotopic fractionation due to incomplete recovery, were examined with an artificially mixed solution of a composition similar to that of basalt, which was doped with Li isotopic standard reagent. The examinations demonstrated that our protocol suffered from negligible isotopic fractionation.The Li isotopic ratios obtained by our method for seawater and standard rocks (JA-1, JB-2, and JB-3) agree well with those of previously reported data by Moriguti and Nakamura [1] and [2], which were determined using a four-step column separation method and thermal ionisation mass spectrometry (TIMS). Our separation protocol combined with a sensitive MC-ICP-MS will enable Li isotopic analyses on silicate rock with low Li contents, such as meteorite and peridotites with increased sample throughput.  相似文献   

14.
稳定同位素分析是分析化学一项颇具前景的分支,通过精确测定物质的稳定同位素比值,可以追溯物质来源并探究其转化过程。高精度稳定同位素分析技术的进步依赖于新一代质谱仪的不断发展。其中,多接收器电感耦合等离子体质谱(MC-ICP-MS)是近年发展迅速的一种同位素组成测定工具。稳定同位素分析对样品基质十分敏感,复杂基质能严重干扰同位素测定的精密度和准确度。这对MC-ICP-MS的样品净化提出了极高要求,目前也是同位素分析领域的热点问题。该文聚焦于近年来MC-ICP-MS在样品净化及仪器联用方法方面的相关研究进展,并展望了MC-ICP-MS稳定同位素分析的应用前景。  相似文献   

15.
Uranium isotope ratio U 234/238 can be measured by commercial high-performance inductively coupled plasma mass spectrometry (ICP-MS) with good precision and accuracy (relative standard deviation RSD<2%). The method is based on acquiring the data using a peak jump mode and a collecting signal 10 times longer for low abundance isotopes. Uranium isotope standards U-005 to U-200 from the National Bureau of Standards (NBS) were used for method development. The optimum uranium concentration range for analysis for dissolved samples is from 50 to 200 g l–1.  相似文献   

16.
A method was developed to improve the precision of inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) for the determination of boron isotope ratios (11B/10B) in various environmental materials including seawater. This approach is based on the common analyte internal standardization (CAIS) chemometric algorithm. The sample solution obtained after digestion is spiked with lithium, and both 7Li/6Li and 11B/10B values are measured using long-counting periods (20 min). The CAIS algorithm corrects the measured 11B/10B values for (a) statistical fluctuations resulting from short-term noise; (b) drift in 11B-to-10B ratio as a result of long-term deviation in instrumental parameters likely to occur during long counting times; (c) change in 11B-to-10B ratio caused by variation in matrix elements concentrations; and (d) drift in mass bias correction factor. Comparing boron isotopic ratios in seawater measured by conventional and the new isotope ratio methods validates the procedure. A synthetic isotopic mixture of boron SRM 951 and enriched 10B SRM 952 also was examined. The CAIS method provided a measured boron isotopic ratio precision of 0.05% R.S.D. while eliminating 5.1% matrix concentration error and 0.25% instrumental drift error.  相似文献   

17.
Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) was applied to the certification of Pb in four levels of NIST blood SRM, 955a. This standard reference material (SRM) represents a significant improvement over the previous blood reference material and will greatly aid method development. The lowest level, 47.76 ng/g Pb was determined with analysis uncertainty (95% CI, ID-ICP-MS uncertainties) of less than 1% and the highest level, 517.9 ng/g Pb to 0.3%. Uncertainty in the lowest level was due to sample inhomogeneity and variability in the analytical blank as the RSD on ratio measurements was typically better than 0.2%. Properly applied isotope dilution coupled with careful isotope ratio measurements on the ICP-MS offers precision and accuracy for blood Pb analyses beyond what is currently obtainable with routine methods.  相似文献   

18.
Isotope dilution-inductively coupled plasma mass spectrometry (ID-ICP/MS) was applied to determine mercury in living tissue. Microwave digestion method using HNO3/H2O2 media for the dissolution of solid sample was studied. The procedure for accurate determination of total mercury in tuna fish tissue sample by ID-ICP/MS is described. For the method validation, total Hg concentration in tuna fish CRM (BCR CRM 463) was determined by ID-ICP/MS after addition of 202Hg to CRM followed by acid decomposition of the spiked sample. This method was applied to the determination of Hg in tuna fish CCQM-P39 sample provided by IRMM (Institute for Reference Materials and Measurement, GEEL, Belgium) for the international comparison study.  相似文献   

19.
The analytical performance of five sample introduction systems, a cross flow nebulizer spray chamber, two different solvent desolvation systems, a multi-mode sample introduction system (MSIS), and a hydride generation (LI2) system were compared for the determination of Se isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). The optimal operating parameters for obtaining the highest Se signal-to-noise (S/N) ratios and isotope ratio precision for each sample introduction were determined. The hydride generation (LI2) system was identified as the most suitable sample introduction method yielding maximum sensitivity and precision for Se isotope ratio measurement. It provided five times higher S/N ratios for all Se isotopes compared to the MSIS, 20 times the S/N ratios of both desolvation units, and 100 times the S/N ratios produced by the conventional spray chamber sample introduction method. The internal precision achieved for the 78Se/82Se ratio at 100 ng mL−1 Se with the spray chamber, two desolvation, MSIS, and the LI2 systems coupled to MC-ICP/MS was 150, 125, 114, 13, and 7 ppm, respectively. Instrument mass bias factors (K) were calculated using an exponential law correction function. Among the five studied sample introduction systems the LI2 showed the lowest mass bias of −0.0265 and the desolvation system showed the largest bias with −0.0321. Figure Illustration of the multi-mode sample introduction system for Se isotope ratiomeasurements  相似文献   

20.
Two enriched isotopes, 99.94 at.% 56Fe and 99.90 at.% 54Fe, were blended under gravimetric control to prepare ten synthetic isotope samples whose 56Fe isotope abundances ranged from 95% to 20%. For multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements typical polyatomic interferences were removed by using Ar and H2 as collision gas and operating the MC-ICP-MS system in soft mode. Thus high-precision measurements of the Fe isotope abundance ratios were accomplished. Based on the measurement of the synthetic isotope abundance ratios by MC-ICP-MS, the correction factor for mass discrimination was calculated and the results were in agreement with results from IRMM014. The precision of all ten correction factors was 0.044%, indicating a good linearity of the MC-ICP-MS method for different isotope abundance ratio values. An isotopic reference material was certified under the same conditions as the instrument was calibrated. The uncertainties of ten correction factors K were calculated and the final extended uncertainties of the isotopic certified Fe reference material were 5.8363(37) at.% 54Fe, 91.7621(51) at.% 56Fe, 2.1219(23) at.% 57Fe, and 0.2797(32) at.% 58Fe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号