首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An environmentally friendly and rapid digestion procedure involving 10 mL of acid mixture (HNO3 : HCl : HF = 2:2:1) for 0.1 g of sample in closed vessel microwave digester following heating program : 250W for 10 min., hold time 2 min., 600 W for 17 min, and Ventilation time 10 min was developed. The operating parameters were varied and optimized by factorial design approach using "Steepest Ascent" method. The validity of the recommended digestion procedure were examined by analyzing several well characterized standard reference materials such as diabase (W2), basalt (BIR-1, JB-3, BHVO-1), granite (G2), gabbro (JGb-1), Mn-nodule (Nod-A-1, Nod-P-1), sediment (STSD-4, LKSD-2), limestone (KH-2), soil (SAu-1), ilmenite (IGS-31), rutile (IGS-32), Zircon (IGS-35) and titanium dioxide (SRM-154b) employing both inductively coupled plasma-atomic emission spectrometry (ICP-AES) and well known spectrophotometric method. An excellent agreement between the methods and the certified values of standard reference materials suggest that the digestion procedure can be used for quality control and allied purposes.  相似文献   

2.
Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultra-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B&C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS.  相似文献   

3.
Determination of selenium in soil by hydride generation AAS   总被引:2,自引:0,他引:2  
Hydride generation AAS was applied for the determination of total selenium in soil. The influence of various anions and cations present in the sample solution on the generation of selenium hydride was investigated. Special attention was paid to the wet oxidation procedure for the sample dissolution. The proposed procedure involves microwave sample preparation by using a mixture of H2O2/HNO3/H2SO4. The accuracy of the procedure was checked by the analysis of the standard reference material Buffalo River Sediment (SRM-2704, NIST). Satisfactory agreement of the results obtained with the values reported was achieved. The detection limit of the procedure was 25 ng Se/g of soil. The relative standard deviation of the measurements varied from 5.5% for SRM-2704 up to 10% for the real soil samples. Received: 20 January 1997 / Revised: 24 February 1997 / Accepted: 1 March 1997  相似文献   

4.
Nine decomposition procedures for soil samples, such as via acid mixtures and fusion in open systems and microwave and autoclave dissolution (in closed systems under elevated temperature and pressure) were assessed using certified soil reference materials. The determination of various elements in solutions was performed by FAAS and ICP-OES and the results were compared with certified values and with direct current arc OES analysis. Received: 3 March 1997 / Revised: 30 May 1997 / Accepted: 3 June 1997  相似文献   

5.
Neutron activation analysis (NAA) is one of the most used analytical techniques for trace element determination in rocks, because time consuming operations are avoided. We have analyzed different types of USGS reference materials (G-2, GSP-1, BHVO-1, STM-1, GXR-3, GXR-4, GXR-5), using both thermal (TNAA) and epithermal neutrons (ENAA). ENAA has been used to reduce interferences due to Sc-46 and to other high activities. The following elements have shown an improvement when analyzed by ENAA: Ba, Cs, Gd, Rb, Sb, Sr, Ta, Tb, Th, Tm, U, Yb, Zr; better results were found for Ce, Co, Cr, Eu, Fe, Hf, La, Lu, Na, Nd, Sc, Zn with TNAA. The accuracy of both methods has been tested comparing our results with some published values. The agreement is in general very good. The precision also is satisfactory, being for many elements better than 10%. After these tests, a study on some rock samples from the basaltic plateau of Kenya, east of Gregory Rift, has been performed by ENAA. Among the elements determined in this work, the rare earch elements (REE) can give significant petrogenetic information, by means of their distribution and fractionation in the rocks. The main parameters investigated are the degree of fractionation of light (La to Eu) relative to heavy (Gd to Lu) REE and the occurence of Eu anomalies, when the REE concentrations are compared to chondritic values. The evaluation of detection limits by TNAA has been performed for REE in sediment samples from Thyrrenian Sea (Central Italy).  相似文献   

6.
A flow injection hydride manifold was coupled to a 150 W tungsten coil electrothermal atomizer for in situ hydride collection followed by selenium and arsenic determination by ET AAS. Rhodium (200 μg), thermally reduced over the double layer tungsten atomizer, was very efficient at collecting selenium or arsenic hydrides. Prior to analysis, biological samples were digested in closed-vessels microwave digestion system. Prior to the hydride formation, both selenium and arsenic were reduced to valence state (IV) and (III), respectively. The detection limit was 35 ng L−1 for selenium and 110 ng L−1 for arsenic. Sample throughput was 70 h−1 using 30 s of hydride trapping time. Method accuracy was evaluated by analyzing biological-certified reference materials from the National Institute of Standard and Technology (SRM-1577a and SRM-1577b “bovine liver” and RM-8414 “bovine muscle powder”) and from the International Agency for Energy Atomic (A-13 “animal blood”) and one water-certified reference material from the National Institute of Standard and Technology (SRM-1640 trace elements in natural water). By applying a t-test, there was no significant difference at the 95% probability level between the results obtained with the proposed method and those certified values.  相似文献   

7.
Vitamin K is an essential micronutrient required for blood coagulation, regulation of vascular calcification and bone mineralization. Plasma and serum measurements of vitamin K1(phylloquinone, K1) made using high-performance liquid chromatography with fluorescence detection, or tandem mass spectrometry are used clinically and in population studies to assess vitamin K status. Standard reference materials provide a validation tool for laboratories, helping assure clinical diagnosis and the comparability of data from different populations. We manufactured two K1 standard reference materials, in 2009 (KEQAS SRM-001) and in 2019 (KEQAS SRM-002). The target concentrations of K1 were assigned to each SRM using the All Laboratory Trimmed Mean of results reported by selected laboratories enrolled in the Vitamin K External Quality Assurance Scheme (KEQAS). The assigned concentrations of K1 for KEQAS SRM-001 and SRM-002 were 0.25 and 0.36 μg/L respectively. In 2019 KEQAS SRM-001 was re-analysed simultaneously with KEQAS SRM-002 to provide traceability between the two standards, therefore aiding comparability of analysis performed using these materials. Both standards were stored as aliquots at −80°C in the dark; annual re-analysis of the materials indicated that K1 is stable for at least 12 years in these conditions.  相似文献   

8.
Radiochemical neutron activation method is presented for the determination of iridium in geological materials. The procedure consisted of thermal neutron irradiation of an 500 mg sample followed by sinterization with sodium peroxide, precipitation with tellurium and high resolution gamma-spectrometry with a hyper-pure Ge-detector. The procedure was evaluated by the analysis of the certified reference materials SARM-7 and W-1. The detection limit for the analytical conditions employed was 0.004 ng·g–1 Ir. The procedure was applied to the reference materials TDB-1 and WGB-1, which present provisional values for Ir concentration, and GXR-3, GXR-5 and GXR-6, which do not present any reported data for Ir contents.  相似文献   

9.
采用电感耦合等离子体质谱(ICP-MS)与等离子体光谱(ICP-OES)联机同时测定多金属结核样品中常量、微量、痕量元素。样品经高压密封溶样弹消解后,一次气动雾化进样,ICP-OES测定常量和微量元素,ICP-MS测定微量和痕量元素。详细探讨了不同浓度范围元素的测定方式、元素分析信号的采集模式、多原子离子干扰的校正因子。采用ICP-MS与ICP-OES二种方式同时测定Co、Cu、Ni、Zn、V、Ba、Sr,分析结果表明具有较好的一致性。所建立的ICP-MS与ICP-OES联机检测技术用于多金属结核标准样品的分析(Nod-A-1,GSPN-1,GSPN-2,GSPN-3),分析结果与推荐值符合,相对标准偏差小于10%。  相似文献   

10.
A comparison of two group separation techniques using either NaI(Tl) or Ge(Li) spectrometry is presented for trace element determination in biological materials by neutron activation analysis. The capabilities of both procedures are described in terms of detection limits, precision and accuracy for the determination of the elements As, Cd, Co, Cr, Cu, Fe, Hg, Mo, Ni, Sb, Se, Sn, and Zn in various types of biological samples. For this purpose the (standard) reference materials NBS SRM-1577 Bovine Liver, Bowen's Kale, IAEA Pig Kidney H-7 and IAEA Milk Powder A-11 were analyzed. An attempt was also made to minimize blank values for several elements.  相似文献   

11.
Preparation techniques for single-element and multielement standard solutions, with special emphasis on the potential progress in this field are presented. A short review of locally available reference materials is given. Some aspects of the experience accumulated in Romania regarding the various certification approaches of reference materials are presented and the main characteristics of these certified reference materials are listed. Received: 23 May 1997 / Revised: 15 August 1997 / Accepted: 15 August 1997  相似文献   

12.
The electrochemical dissolution of molybdenum and tungsten in a 0.5 M solution of sodium sulfate at various temperatures was studied. The conditions of the efficient recovery of molybdenum from the binary metal system Mo-W were determined.  相似文献   

13.
The capabilities of neutron and photon activation analysis (NAA and PAA, respectively) for low-level determination of silicon in biological materials have been examined. Sensitivities of a variety of modes of NAA and PAA with radiochemical separation have been evaluated. Results are presented for silicon in reference materials CSRM 12-2-03 Lucerne, Bowen's Kale, NIST SRM-1571 Orchard Leaves, and NIST SRM-1515 Apple Leaves. The results were obtained by employing the 29Si(n,p)29Al reaction with fast reactor neutrons and the radiochemical procedure developed for aluminium separation. Possibilities of further improvement of the silicon determination limit down to the microg g(-1) level by employing NAA and PAA with radiochemical separation are outlined.  相似文献   

14.
The metathesis reaction of Cp*(CO)3MoBr and NaW(CO)3Cp produced Cp*(CO)3Mo-W(CO)3Cp (1), featuring an unsupported Mo-W bond. Exposure of solutions of 1 to light leads to the quantitative formation of the corresponding homometallic dimers. In the solid state, the title complex exhibits an anti-arrangement of the η5-cyclopentadienyl and the η5-pentamethyl-cyclopentadienyl ligands and six terminal carbonyls. Comparison to corresponding complexes of molybdenum and tungsten reveals that the Mo-W distance is dictated by the presence of a Cp and a Cp* ligand. This is the first time that an unsupported Mo-W single bond distance is reported.  相似文献   

15.
Direct solid sampling graphite furnace AAS (SS-GF-AAS) provides an advantageous alternative to the conventional AAS which requires wet digestion of the samples. This method is suitable for trace element determination in calcium fluoride and other fluoride-containing samples. Matrix effects were studied by using calibration standards, certified reference materials with different matrices and by means of three-dimensional calibration. 3D calibration is suitable for selection of calibration samples for more reliable analyses. Cu, Pb, Cd, Zn, and Fe were determined by means of calibration with variation of sample weight using certified reference materials and suitable fluoride-containing calibration samples. Received: 25 July 1997 / Revised: 15 December 1997 / Accepted: 20 December 1997  相似文献   

16.
Direct solid sampling graphite furnace AAS (SS-GF-AAS) provides an advantageous alternative to the conventional AAS which requires wet digestion of the samples. This method is suitable for trace element determination in calcium fluoride and other fluoride-containing samples. Matrix effects were studied by using calibration standards, certified reference materials with different matrices and by means of three-dimensional calibration. 3D calibration is suitable for selection of calibration samples for more reliable analyses. Cu, Pb, Cd, Zn, and Fe were determined by means of calibration with variation of sample weight using certified reference materials and suitable fluoride-containing calibration samples. Received: 25 July 1997 / Revised: 15 December 1997 / Accepted: 20 December 1997  相似文献   

17.
    
Summary Instrumental and radiochemical neutron activation analysis results are reported for 28 elements in NIST SRM-1515 Apple Leaves and NIST SRM-1547 Peach Leaves which were analyzed as intercomparison samples before their certification. Results for NIST SRM-1571 Orchard Leaves and Bowen's Kale analyzed as control samples are also given. The very good accuracy of INAA and RNAA is shown by the close comparison of the present results with the certified, information, and literature data on the materials analyzed.  相似文献   

18.
The analytical literature about chromium speciation in solid samples has been surveyed. From 451 articles published on the speciation of chromium from 1983 to 1997, the methodologies to do speciation in solids after sample pretreatment are discussed, through consideration of the types of samples and their dissolution, the analytical techniques employed for chromium measurement, and the figures of merit of the 86 papers reported in the Analytical Abstracts data base. Received: 6 February 1998 / Revised: 6 March 1998 / Accepted: 7 March 1998  相似文献   

19.
Uranium-233 (t 1/2 ~ 1.59E5 years) is an artificial, fissile isotope of uranium that has significant importance in nuclear forensics. The isotope provides a unique signature in determining the origin and provenance of uranium-bearing materials and is valuable as a mass spectrometric tracer. Alpha spectrometry was employed in the critical evaluation of a 233U standard reference material (SRM-995) as a dual tracer system based on the in-growth of 229Th (t 1/2 ~ 7.34E3 years) for ~35 years following radiochemical purification. Preliminary investigations focused on the isotopic analysis of standards and unmodified fractions of SRM-995; all samples were separated and purified using a multi-column anion-exchange scheme. The 229Th/233U atom ratio for SRM-995 was found to be 1.598E?4 (±4.50 %) using recovery-corrected radiochemical methods. Using the Bateman equations and relevant half-lives, this ratio reflects a material that was purified ~36.8 years prior to this analysis. The calculated age is discussed in contrast with both the date of certification and the recorded date of last purification.  相似文献   

20.
The application of open vessel focused microwave acid digestion is described for the preparation of geological and environmental samples for analysis using inductively coupled plasma-mass spectrometry (ICP-MS). The method is compared to conventional closed-vessel high pressure methods which are limited in the use of HF to break down silicates. Open-vessel acid digestion more conveniently enables the use of HF to remove Si from geological and plant samples as volatile SiF4, as well as evaporation-to-dryness and sequential acid addition during the procedure. Rock reference materials (G-2 granite, MRG-1 gabbros, SY-2 syenite, JA-1 andesite, and JB-2 and SRM-688 basalts) and plant reference materials (BCR and IAEA lichens, peach leaves, apple leaves, Durham wheat flour, and pine needles) were digested with results comparable to conventional hotplate digestion. The microwave digestion method gave poor results for granitic samples containing refractory minerals, however fusion was the preferred method of preparation for these samples. Sample preparation time was reduced from several days, using conventional hotplate digestion method, to one hour per sample using our microwave method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号