首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Accurate measurement of estradiol (E2) is important in clinical diagnostics and research. High sensitivity methods are critical for specimens with E2 concentrations at low picomolar levels, such as serum of men, postmenopausal women and children. Achieving the required assay performance with LC–MS is challenging due to the non‐polar structure and low proton affinity of E2. Previous studies suggest that ionization has a major role for the performance of E2 measurement, but comparisons of different ionization techniques for the analysis of clinical samples are not available. In this study, female serum and endometrium tissue samples were used to compare electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) in both polarities. APPI was found to have the most potential for E2 analysis, with a quantification limit of 1 fmol on‐column. APCI and ESI could be employed in negative polarity, although being slightly less sensitive than APPI. In the presence of biological background, ESI was found to be highly susceptible to ion suppression, while APCI and APPI were largely unaffected by the sample matrix. Irrespective of the ionization technique, background interferences were observed when using the multiple reaction monitoring transitions commonly employed for E2 (m/z 271 > 159; m/z 255 > 145). These unidentified interferences were most severe in serum samples, varied in intensity between ionization techniques and required efficient chromatographic separation in order to achieve specificity for E2. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Anion attachment atmospheric pressure photoionization (AA-APPI) has been suggested as a means of expanding the range of compounds that may be analyzed by LC-MS, and has been found to enhance the ionization of some macromolecules (e.g., peptides, polymers) that were unable to be ionized by other techniques. In this study, AA-APPI was compared to APPI, using hexabromocyclododecane (HBCD) enantiomers as a model compound, to provide proof of principle of the use of AA-APPI for small molecule analysis. The use of AA-APPI, with 1,4-dibromobutane in toluene as a bromide source, offered increased sensitivity and lower limits of detection than APPI. Minimal matrix effects were found with AA-APPI in sediment extracts spiked with HBCD post-extraction, with less than a 6% enhancement in the ion signal. Furthermore, enantiomer fractions of HBCD enantiomers were racemic in spiked sediment extracts, in contrast to the more commonly used technique of electrospray ionization, for which matrix effects caused ion signal modification to cause non-racemic measurement artifacts. The use of AA-APPI offers a simple means of further extending the range of compounds ionizable by AA-APPI while maintaining minimal matrix effects.  相似文献   

3.
A comparison was made between the electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) tandem mass spectrometric (MS/MS) responses of eleven ultraviolet (UV) filters. Four of the target compounds were favourably ionized in negative ion mode, and the other seven compounds in positive ion mode. For nine of the compounds APPI generated a similar response to that of ESI, but the APPI signal‐to‐noise (S/N) ratios were 1.3–60 times higher. The two most polar of the UV filter compounds (PBSA and BP‐4) were more efficiently ionized by ESI, offering higher signal intensities and lower detection limits. APPI was, however, less susceptible to ion suppression than ESI when real samples were injected. In order to optimize the APPI conditions different dopant solvents were examined to enhance the efficiency of the photoionization process. Among the evaluated dopants, toluene was selected as the best compromise. At a toluene flow rate of 10% of the solvent flow rates the ionization response increased by a factor of 40–50 over the use of no dopant for the compounds in positive ion mode and by more than 300 for the compounds in negative ion mode. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

5.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

6.
Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.  相似文献   

7.
Capillary electrophoresis (CE) has been combined with atmospheric pressure photoionization (APPI) and electrospray ionization (ESI) for mass spectrometric (MS) detection. Separation conditions using potassium phosphate buffer and ammonium formate buffer have been compared for analysis of eleven pharmaceutical bases. The results showed improvements in separation efficiency and peak symmetry when phosphate buffer was used. The low flow in CE may enable utilization of these advances with MS detection. Compared with ESI, the APPI technique provided a cluster-free background. The enhanced signal-to-noise ratio in the total ion current (TIC) and the reduced spectral background indicated that the APPI process is less affected by non-volatile salts in the CE buffers. This results in a wider range of choice of CE buffers in CE/MS analysis when APPI is the ionization method.  相似文献   

8.
ESI and APCI ionization techniques in both negative and positive ion modes were evaluated for simultaneous LC-MS analysis of the four tocopherol homologues (alpha, beta, gamma and delta). The ESI and APCI ionization of tocopherols in positive ion mode was not efficient and proceeded via two competitive mechanisms, with the formation of protonated pseudo-molecular ions and molecular ions, which adversely influenced the repeatability of MS signal. Ionization in negative ion mode in both ESI and APCI was more efficient as it only produced target deprotonated pseudo-molecular ions. The APCI in negative ion mode showed larger linearity range, lower detection limits and was less sensitive to the differences in chemical structure of analytes and nature of applied solvents than negative ion ESI. Negative ion APCI was, therefore, chosen for the development of LC-MS method for simultaneous determination of the four tocopherols in foods. A baseline separation of the tocopherols was achieved on novel pentafluorophenyl silica-based column Fluophase PFP. The use of methanol-water (95:5, v/v) as a mobile phase was preferable to the use of acetonitrile-water due to considerable gain in MS signal. The limits of quantifications were 9 ng/mL for alpha-tocopherol, 8 ng/mL for beta- and gamma- and 7.5 ng/mL for delta-tocopherol when 2 microL was injected. This method was successfully applied to determination of tocopherols in sunflower oil and milk.  相似文献   

9.
This review presents our perspective on the state-of-the-art of atmospheric pressure photoionization (APPI) for LC/MS. Its focus is on APPI's capabilities and how to utilize them fully. The introduction includes a brief recounting of the history of APPI's development, as well as a summary of its operating principles and current position in the field. The primary ionization mechanisms in APPI are then addressed, including direct analyte photoionization (PI), dopant/solvent PI, and thermospray. Next a summary of the ion-molecule reaction pathways available for analyte ionization is presented, along with the conditions required for activating them. APPI's performance characteristics are then examined. In effect, this review is an interim report on progress made since Rafaelli and Saba concluded that “The ability…to direct the preferential ion formation towards one particular type…can be extremely useful for qualitative and quantitative determinations. For this purpose, a better insight in the processes involved in the ionization step is strongly needed” [A. Raffaelli, A. Saba, Mass Spectrom. Rev. 22 (2003) 318]. In the conclusion, we focus on areas of APPI technology identified as being either unoptimized or largely unexplored, and having the potential to be improved upon—the crux being that with further research and development improvements in the performance, capabilities, and ease-of-use of APPI may reasonably be anticipated.  相似文献   

10.
In sesame seeds, high concentrations of lignans are present. When these lignans are fermented in the human colon, a range of structurally different lignans is formed. A good liquid chromatography/mass spectrometry (LC/MS) protocol for the analysis of lignans in complex mixtures is lacking. In order to develop such a protocol, electrospray ionization (ESI)-MS and atmospheric pressure chemical ionization (APCI)-MS, both in the positive and negative ionization mode, were compared. An extract from defatted sesame meal was analyzed by APCI-MS and ESI-MS, before and after deglucosylation. APCI-MS was found to be a more generic method than ESI-MS because lignans, especially sesamolin, sesamin and pinoresinol, were better detected by APCI-MS than by ESI-MS. Positive and negative ionization modes had to be combined in order to detect all lignans in a bacterial culture grown on aglyconic, acid-treated lignans from sesame oil and defatted sesame meal. Lignans with methylenedioxy-bridged furanofuran structures mostly lack phenolic hydroxyl groups and were, therefore, optimally detected in positive ionization mode. Dibenzylbutadiene lignans, which were formed during fermentation, carry hydroxyl groups and were better detected in negative ionization mode.  相似文献   

11.
Gas chromatography (GC) and ion trap mass spectrometry (MS) were combined with microchip atmospheric pressure chemical ionization (microAPCI) and microchip atmospheric pressure photoionization (microAPPI) sources. Selected polychlorinated biphenyls (PCBs, IUPAC Nos. 28, 52, 101, 118, 138, 153 and 180) were analyzed by GC/microAPCI-MS and GC/microAPPI-MS to demonstrate the applicability of the miniaturized ion sources in negative ion mode analysis. The microAPCI and microAPPI methods were evaluated in respect of detection limit, linearity and repeatability. The detection limits for the PCB congeners were somewhat lower with microAPCI than with microAPPI, whereas microAPPI showed slightly wider linear range and better repeatability. With both methods, the best results were obtained for highly chlorinated or non-ortho-chlorinated PCBs, which possess the highest electron affinities. Finally, the suitability of the GC/microAPPI-MS method for the analysis of PCBs in environmental samples was demonstrated by analyzing soil extracts, and by comparing the results with those obtained by gas chromatography with electron capture detection (GC/ECD).  相似文献   

12.
The performance of dopant-assisted atmospheric pressure photoionization (DA-APPI) and electrospray ionization (ESI) for the coupling of micellar electrokinetic chromatography (MEKC) with ion trap mass spectrometry (ITMS) was compared using a set of test drugs comprising basic amines, steroids, esters, phenones and a quaternary ammonium compound. The influence of the surfactant sodium dodecyl sulfate (SDS) on analyte signals was studied by infusion of sample through the CE capillary into the respective ion sources. It was found that background electrolytes (BGEs) containing 20-50mM SDS in 10mM sodium phosphate (pH 7.5) caused major ionization suppression for both polar and apolar compounds in ESI-MS, whereas APPI-MS signal intensities remained largely unaffected. ESI gave rise to the formation of SDS clusters, which occasionally may cause space-charge effects in the ion trap. Furthermore, extensive sodium-adduct formation was observed for medium polar compounds with ESI-MS, whereas these compounds were detected as their protonated molecules with APPI-MS. Using the BGE containing 20mM SDS, MEKC-ESI-MS still provides slightly lower limits of detection (LODs) (2.6-3.1muM) than MEKC-APPI-MS (4.3-6.4muM) for basic amines. For less polar compounds, highest S/Ns were obtained with APPI-MS detection (LODs, 4.5-71muM). For BGEs containing 50mM SDS, the limits of detection for MEKC-APPI-MS were more favorable (factor 1.5-12) than MEKC-ESI-MS for nearly all tested drugs. Spray shield contamination by SDS was lower in DA-APPI-MS than in ESI-MS. It is concluded that DA-APPI shows the most favorable characteristics for MEKC-MS, especially when compounds of low polarity have to be analyzed.  相似文献   

13.
14.
A new method is described for performing hydrogen/deuterium (H/D) exchange in an electrospray ionization (ESI) source. The use of liquid chromatography (LC)-mass spectrometer equipped with an ESI source and deuterium oxide (D2O) as the sheath liquid allows H/D exchange experiments to be performed on-line. This directly provides information for determining the number and position of exchangeable hydrogens, aiding in the elucidation of the structures of drug metabolites. To demonstrate the utility of this method, LC-mass spectrometry (MS) and LC-MS/MS experiments were performed using either H2O or D2O as sheath liquid on a matrix metalloprotease (MMP) inhibitor (PD 0200126) and its metabolites. Examination of the mass shift of the deuteriated molecule from that of the protonated molecule allowed the number of exchangeable protons to be determined. Interpretation of the production-spectra helped to determine the location of the exchanged protons and assisted in the assignment of the site(s) of modification for each metabolite.  相似文献   

15.
The sensitivity of dopant-assisted atmospheric pressure photoionization (DA-APPI) for LC/MS is generally reduced at higher solvent flow rates. Theory suggests that quenching of excited-state precursors to the dopant ions, via collisions with vaporized solvent molecules, may be one mechanism responsible for this trend. To ascertain if the primary rate of ionization is affected by quenching, experiments were performed utilizing an ionization detector to determine the primary ion current generated by irradiating vaporized mixtures of toluene dopant and methanol solvent. The results indicate that no loss of primary ion current occurs as the solvent flow is increased, provided the dopant-to-solvent ratio is held constant. Additional primary ion current can always be generated by increasing the dopant flow rate and/or the lamp power. Thus, quenching of excited-state precursors to the dopant ions, leading to a reduction in the primary rate of ionization, is not the mechanism responsible for the observed loss of sensitivity at higher liquid solvent flow rates.  相似文献   

16.
An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells.  相似文献   

17.
The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.  相似文献   

18.
Mass spectra of urea nitrate were measured in electrospray ionization and in atmospheric pressure chemical ionization in the negative mode. In both ionization methods two characteristic adduct ions containing the intact molecule [urea nitrate+NO3]- and [urea nitrate+HNO3+NO3]- are shown. The structure of the two adduct ions was deduced using measurements of isotopically labeled urea nitrate. Collision-induced dissociation measurements of the adduct ions show typical losses enabling the identification of urea nitrate in trace amounts. Using these methods urea nitrate was identified in real cases.  相似文献   

19.
Diagnosis by online breath analysis using mass spectrometry is challenging because of the low concentrations of pertinent compounds in breath. Here we investigate extractive electrospray ionization and atmospheric pressure chemical ionization for the detection of narcotics in breath. The limit of detection was evaluated for morphine, fentanyl, norfentanyl, naloxone, cocaine, γ-hydroxybutyrolactone (GBL), and nicotine. They were found to be in the low fmol/s range, depending on the ionization system used. Data was obtained on four different mass spectrometers: A quadrupole time-of-fight instrument, a 3D ion trap, a linear ion trap, and a portable ion trap. A system was developed to mix reference compounds with breath for the investigation of the ionization sources as well as for standardization and online quantification of semi-volatile compounds in breath.  相似文献   

20.
Reduction of the oligomers formed from on-line electropolymerization of aniline, the compound N-phenyl-1,4-phenylenediimine, and the thiazine dye thionin was observed in both an atmospheric pressure chemical ionization and an atmospheric pressure photoionization source. The reduction, which alters the mass of these analytes by 2 Da, was shown to occur by means of a surface-assisted process which involves reactive species, possibly hydrogen radicals, generated from protic solvents in the ionization plasma. Reduction was minimized by limiting protic solvents, by using a high heated nebulizer temperature, and by using a clean, heated nebulizer probe liner. The expected generality of this reduction process, and the possibility of similar reduction processes in other plasma ionization sources are discussed in relation to the use of these ion sources for on-line electrochemistry/mass spectrometry experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号