 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this work, a high-throughput and high-performance bioanalytical system is described that is capable of extracting and analyzing 1152 plasma samples within 10 hours. A Zymark track robot system interfaced with a Tecan Genesis liquid handler was used for simultaneous solid-phase extraction of four 96-well plates in a fully automated fashion. The extracted plasma samples were injected onto four parallel monolithic columns for separation via a four-injector autosampler. The use of monolithic columns allowed for fast and well-resolved separations at a considerably higher flow rate without generating significant column backpressure. This resulted in a total chromatographic run cycle time of 2 min on each 4.6 x 100 mm column using gradient elution. The effluent from the four columns was directed to a triple quadrupole mass spectrometer equipped with an indexed four-probe electrospray ionization source (Micromass MUX interface). Hence, sample extraction, separation, and detection were all performed in a four-channel parallel format that resulted in an overall throughput of about 30 s per sample from plasma. The performance of this system was evaluated by extracting and by analyzing twelve 96-well plates (1152) of human plasma samples spiked with oxazepam at different concentrations. The relative standard deviation (RSD) of analyte sensitivity (slope of calibration curve) across the four channels and across the 12 plates was 5.2 and 6.8%, respectively. An average extraction recovery of 77.6% with a RSD of 7.7% and an average matrix effect of 0.95 with a RSD of 5.2% were achieved using these generic extraction and separation conditions. The good separation efficiency provided by this system allowed for rapid method development of an assay quantifying the drug candidate and its close structural analog metabolite. The method was cross-validated with a conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay.  相似文献   

2.
Organic polymers offer many advantages as materials for the construction of microfluidic devices but suffer frequently from the limitation that the electrodynamic flow they support can exhibit considerable instability. This article describes a split-channel microfluidic device that can be used to compensate for changes in electroosmotic flow. The design of the separation system divides an analyte plug after injection between two separation channels of differing length. The two channels are later recombined for single point detection, eliminating the need for a scanning optical detection system. The utility of this simple design lies in the fact that the migration time of any analyte can be referenced to its twin in the parallel separation channel. This eliminates the need for a separate electroosmotic marker and allows mobilities measured in multiple devices to be compared quantitatively. Using a model adopted from the literature, the data from the split channel system can be used to precisely account for the drift that characterizes electrophoretic separations made in a polymer chip. The relative standard deviations of the analyte mobilities measured for replicate runs on multiple devices were reduced from values as high as 20% to ca. 1% RSD. This internal standardization procedure also appears to address other sources of drift in the electroosmotic flow (EOF) supported by the polymer microchannel, eliminating the need for careful monitoring of either the temperature or reservoir pH between separation runs.  相似文献   

3.
A new parallel liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been developed, in which the mass detector was shared between two staggered parallel chromatographic runs. Since the chromatography for biofluids assay generally requires good analyte retention and thus tends to leave large blank chromatographic windows, this parallel system allowed the efficient use of the mass detector during these blank windows, resulting in significantly improved sample throughput. Also, in order to remove the bottleneck in sample extraction for this parallel separation system, a high-flow extraction device was used to perform on-line extraction. This allowed for the direct injection of biofluids onto the system. The performance and capability of this system was evaluated in tests that contained a single analyte (oxazepam) and multiple analytes (12-in-1). The results indicated that the data generated from this system were comparable to those obtained on a conventional single-column system. An application of the system for high-throughput pharmacokinetic screening of drug candidates was also demonstrated.  相似文献   

4.
A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.  相似文献   

5.
An automated parallel four-column supercritical fluid chromatography (SFC)/MS system to perform high-throughput enantioselective chromatographic method development and optimization is described in this paper. The initial screening was performed in parallel on four chiral SFC columns over several buffer conditions. Optimization of the separation of enantiomers was achieved on a single chiral column. The screening and optimization were accomplished in a fully automated, user-independent manner. Incorporation of column control valves in front of each chiral column allowed the system to switch from parallel four-column screening mode to single-column optimization mode. To facilitate the process, a custom software program, we termed, intelligent parallel optimization for chiral SFC separation (IPOCSS), was developed in-house. The custom software monitored each of the runs in real-time, processed each data set, and by incorporating user-defined criteria (e.g., resolution of the two enantiomer chromatographic peaks), selected the next set of experiments and automatically optimized the enantioseparation. This new approach, combining parallel SFC/MS screening and intelligent software-controlled method optimization, has resulted in a streamlined, high-throughput tool for enantioselective method development, which has been applied successfully to enantioseparations in support of drug discovery.  相似文献   

6.
For the first time, a multisyringe flow injection analysis capillary electrophoresis system is described. The potential of the hyphenation for sample treatment including analyte pre-concentration is demonstrated by its successful application to the determination of mono-nitrophenols (NPs) in different water samples. The analytical system was used to automate in-line sample acidification, analyte pre-concentration, elution, hydrodynamic injection, electrophoretic separation, and detection as well as the maintenance and re-conditioning of the solid-phase extraction (SPE) column and the separation capillary. A pre-concentration factor of better than 115 and detection down to 0.11 micromol L(-1) were achieved. Detection was carried out at visible wavelength using a blue LED as a low baseline-noise light source. High repeatability was obtained each for migration times and for peak heights with relative standard deviations typically below 2.5 and 6% including the pre-concentration procedure, respectively. Three injections per hour were achieved by running in parallel the pre-concentrating and the electrophoretic separation procedures. Instrumental control and data registration and evaluation were carried out with the software package AutoAnalysis, allowing autonomous operation of the analytical system.  相似文献   

7.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

8.
A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for simultaneous determination of resveratrol isomers in rat plasma. Cis-resveratrol was made by exposure of a trans-resveratrol solution to sunlight for 5 days followed by separation by HPLC and identification by mass spectrometry (MS). The assay procedure involved simple liquid-liquid extraction of resveratrol isomers and internal standard (IS, caffeine) from a small plasma volume directly into acetonitrile. The supernatant liquid was added an equal volume of water and injected onto a Hypersil ODS(2) C(18) column (5 microm, 4.6 x 250 mm). Mobile phase consisting of methanol and distilled water was used at a flow rate of 1.0 mL/min for the effective separation of cis-, trans-resveratrol and caffeine (IS). The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of cis-, trans-resveratrol and IS were 3.2, 4.3 and 6.1 min, respectively. The calibration curve was linear ranging from 0.066 to 6.64 and 0.134 to 13.4 microg/mL with correlation coefficients of 0.9998 and 0.9997 for trans and cis isomers, respectively. The absolute recovery of both isomers was more than 85%. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.066, 0.664 and 6.64 microg/mL of trans-resveratrol, were in the range 2.37-6.95% relative standard deviation (RSD) and 0.77-6.97% RSD, respectively. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.134, 1.34 and 13.4 microg/mL of cis-resveratrol, were in the range 1.93-3.72% relative standard deviation (RSD) and 1.13-6.57% RSD, respectively. Both analytes and IS were stable in the battery of stability studies and freeze-thaw cycles. Resveratrol isomers were found to be stable for a period of 30 days on storage at -20 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

9.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

10.
Chen G  Wang J 《The Analyst》2004,129(6):507-511
A newly designed capillary electrophoresis (CE) microchip with a simple and efficient sample introduction interface is described. The sample introduction is carried out directly on the separation channel through a sharp inlet tip placed in the sample vial, without an injection cross, complex microchannel layouts or hardware modification. Alternate placement of the inlet tip in vials containing the sample and buffer solutions permits a volume defined electrokinetic sample introduction. Such fast and simple sample introduction leads to highly reproducible signals with no observable carry over between different analyte concentrations. The performance of the system was demonstrated in flow-injection and CE measurements of nitroaromatic explosives and for on-chip enzymatic assays of glucose in the presence of ascorbic acid. Employing an 8 cm long separation channel and a separation voltage of 4000 V it offers high-throughput flow-injection assays of 100 samples h(-1) with a relative standard deviation of 3.7% for TNT (n= 100). Factors influencing the analytical performance of the new microchip have been characterized and optimized. Such ability to continuously introduce discrete samples into micrometer channels indicates great promise for high-speed microchip analysis.  相似文献   

11.
A novel and very simple microextraction approach for pre-concentration and direct solid phase spectrophotometric measurement has been developed for the determination of chromogenic analytes. The model analyte to assess this approach was the chromophore malachite green (MG). The analyte was extracted from water samples onto a small rotating disk made of Teflon containing a sorbent phase of polydimethylsiloxane (PDMS) on one of its surfaces. We refer to the extraction procedure as rotating disk sorptive extraction (RDSE). After extraction, the sorbent phase with the concentrated analyte was separated from the Teflon disk and used directly for MG determination by solid phase spectrophotometry at 624 nm, without the necessity of a desorption step. Chemical and extraction variables such as concentration of sodium sulfate, pH, disk rotational velocity, extraction time, and temperature were studied in order to establish the best conditions for extraction. Under optimum conditions, the extraction of MG was carried out in 18 min and 90 min, for sample volumes of 100mL or 1000 mL, respectively. The detection limit, based on three times the standard deviation of the blank phase (3σ(b)), was 1.4 μg L?1 and the repeatability, expressed as relative standard deviation (RSD), for 20 μg L?1 MG was 8.1%. This study also applied the method to real samples, obtaining quantitative recovery (mean recovery of 99.3%). The PDMS phases could be reused after desorbing the MG into methanol for 3h. Replacement of the PDMS film onto the disk is very easy and low cost.  相似文献   

12.
A flow injection (FI) on-line solvent extraction system for electrothermal atomic absorption spectrometry (ETAAS) was developed with nickel as a model trace element. The nickel pyrrolidine-dithiocarbamate chelate was extracted on line into isobutyl methyl ketone, which was delivered into the FI system by a peristaltic pump equipped with poly(tetrafluoroethylene) tubing. The organic phase was separated from the aqueous phase by a novel gravity phase separator with a small conical cavity, and stored in a collector tube, from which 50 μl organic concentrate was introduced into the graphite tube by an air flow. ETAAS determination of the analyte was performed in parallel with the extraction process. An enrichment factor of 25 was obtained in comparison with 50 μl direct introduction while achieving a detection limit of 4 ng l−1 (3σ), and a precision of 1.5% relative standard deviation for 1.0 μg l−1 nickel (n = 11). The proposed method was successfully applied to the determination of nickel in body fluids and other biological samples.  相似文献   

13.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of DRF-4367, a novel cyclooxygenase-2 inhibitor in rat plasma. The assay procedure involved simple liquid/liquid extraction of DRF-4367 and internal standard (IS, celecoxib) from plasma into dichloromethane. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C(18) column (4.6 x 250 mm, 5 microm). The mobile phase consisting of 0.01 M potassium dihydrogen ortho-phosphate (pH 3.2) and acetonitrile (40:60, v/v) was used at a flow rate of 1.0 mL/min. The eluate was monitored using an UV detector set at 247 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of DRF-4367 and IS were 6.6 and 11.2 min, respectively. The standard curve for DRF-4367 was linear (r(2) > 0.999) in the concentration range 0.1-20 micro g/mL. Absolute recovery was >86% from rat plasma for both analyte and IS. The lower limit of quantification of DRF-4367 was 0.1 micro g/mL. The inter- and intra-day precisions in the measurement of quality control samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 6.93-9.34% relative standard deviation (RSD) and 0.48-6.59% RSD, respectively. Accuracy in the measurement of QC samples was in the range 91.24-109.36% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. Stability of DRF-4367 was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats is described.  相似文献   

14.
In the present work, dispersive liquid-liquid microextraction based on solidification of floating organic drop was developed as a simple and rapid technique for separation of silver ions from aqueous samples. In this technique, 700 μL 0.02% of 5-(4'-dimethylamino benzyliden)-rhodanine (chelating agent) was added into the 10 mL analyte sample in a test tube and 30.0 μL 1-undecanol (extraction solvent) was injected shortly thereafter. The test tubes were sonicated, centrifuged and then some effective parameters on extraction and complex formation, such as type and volume of extraction and disperser solvent, pH, the amount of chelating agent and extraction time were optimized. The effect of the interfering ions on the analytes recovery was also investigated. The calibration graph was linear in the range of 0.10-10.0 ng mL(-1) with detection limit of 0.056 ng mL(-1) (n=8). The relative standard deviation (RSD) was ±4.3% (n=8, C=5.0 ng mL(-1)) and the enrichment factor was 250.0. The proposed method was applied for extraction and determination of silver in different water samples.  相似文献   

15.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tamsulosin (I), a highly selective alpha1-adrenoceptor antagonist used for the treatment of patients with symptomatic benign prostatic hyperplasia. The analyte and internal standard, mosapride (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Waters symmetry C18 column with a mobile phase of 0.03% formic acid-acetonitrile (30:70, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 409.1 solidus in circle 228.1 and m/z 422.3 solidus in circle 198.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-50.0 ng/mL for tamsulosin in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

16.
Benzylsuccinic acid (BSA) and methylbenzylsuccinic acid (methyl-BSA) are unambiguous biotransformation products resulting from anaerobic toluene and xylene biodegradation, respectively. A solid-phase extraction method based on polystyrene-divinylbenzene sorbent was developed for the quantitative BSA determination in groundwater samples as an alternative to liquid-liquid extraction. Gas chromatography coupled with mass spectrometry was used for separation and detection. The recovery from spiked 11 groundwater samples was 88 to 100%. The precision of the method, indicated by the relative standard deviation, was +/- 4% and the method detection limit was 0.2 microg/l. The concentration of BSA and methyl-BSA in groundwater samples from anaerobic BTEX (benzene, toluene, ethylbenzene and xylenes)-contaminated sites ranged from below the detection limit (3 microg/l) to 155 microg/l.  相似文献   

17.
The use of a poly(methylmethacrylate) capillary electrophoresis chip, provided with a high sample load capacity separation system (a 8500 nL separation channel coupled to a 500 nL sample injection channel) and a pair of on-chip conductivity detectors, for zone electrophoresis (ZE) determination of oxalate in urine was studied. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the separations performed on the chip. A low pH of the carrier electrolyte (4.0) provided an adequate selectivity in the separation of oxalate from anionic urine constituents and, at the same time, also a sufficient sensitivity in its conductivity detection. Under our working conditions, this anion could be detected at a 8 x 10(-8) mol/L concentration also in samples containing chloride (a major anionic constituent of urine) at 3.5 x 10(-3) mol/L concentrations. Such a favorable analyte/matrix concentration ratio (in part, attributable to a transient isotachophoresis stacking in the initial phase of the separation) made possible accurate and reproducible (typically, 2-5% relative standard deviation (RSD) values of the peak areas of the analyte in dependence on its concentration in the sample) determination of oxalate in 500 nL volumes of 20-100-fold diluted urine samples. Short analysis times (about 280 s), no sample pretreatment (not considering urine dilution) and reproducible migration times of this analyte (0.5-1.0% RSD values) were characteristic for ZE on the chip. This work indicates general potentialities of the present chip design in rapid ZE analysis of samples containing the analyte(s) at high ionic matrix/analyte concentration ratios.  相似文献   

18.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

19.
Yang XJ 《Talanta》1994,41(11):1807-1813
An easily applicable separation method has been developed for the accurate and simultaneous determination of trace amounts of Al, Ca, Co, Cr, Cu, Mg, Mn, Ni, Pb and Zn in high purity europium oxide by inductively coupled plasma atomic emission spectrometry (ICP-AES) combined with extraction chromatography. Spectral interferences and europium matrix effects were examined. The chromatographic separation procedure was carried out with a di-(2-ethylhexyl) phosphoric acid (HDEHP)-Levextrel resin as the stationary phase, which retained the matrix europium, and dilute nitric acid as the mobile phase, which eluted the analyte of interest. The effect of nitric acid concentration on the adsorption of europium and the analyte ions on the resin, the eluting behaviour of these elements on the chromatographic column, and the capacity of the resin for europium oxide were investigated. The quantitative limits for determination (10 sigma), based on a 0.5-g amount of europium oxide, are between 0.36 microg/g for Mn and 6.4 microg/g for Pb. The method was applied to two spiked samples and a high purity europium oxide certified reference material. Results were obtained for recoveries of 93.2-112% and precision of 4-13%, expressed as the relative standard deviation and excellent agreement with the certified value with a relative error of <4%.  相似文献   

20.
Azo dyes are widely used in formulations intended for children use. But their potential toxicity raised the need of an efficient and fast method of analysis. A study for the optimization of the extraction of some azo colorants used in toys was conducted. Several extraction methods for the selected analytes were evaluated and compared, i.e., supercritical fluid extraction (SFE), microwave-assisted extraction (MAE) and Soxhlet extraction. Poly(vinyl chloride) samples spiked with known quantities of the studied dyes were prepared. The influence of critical variables on analyte recoveries in SFE and MAE was investigated by using a full-level factorial design, where most significant parameters as well as order interactions were studied in each case. The analytes were subsequently detected by high-performance liquid chromatography with UV detection. The three extraction techniques were compared in terms of reproducibility, selectivity and analyte recoveries. MAE showed higher recoveries (above 98%), except for the diazo dye (nearly 60%). Reproducibilities were generally good for the three methods (relative standard deviation lower than 2.0%).  相似文献   