首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Surface reversible addition-fragmentation chain transfer (RAFT) polymerization method was firstly applied to the preparation of molecularly imprinted polymer (MIP) coated silicon solid-phase microextraction (SPME) fibers. With Sudan I as template, an ultra-thin MIP coating with about 0.55-μm thickness was obtained with homogeneous structure and controlled composition, due to the controllable radical growing and chain propagation in surface RAFT polymerization. The MIP-coated fibers were found with enhanced selectivity coefficients (3.0–6.5) to Sudan I–IV dyes in contrast with those reported in our previous work. Furthermore, the ultra-thin thickness of MIP coating was helpful to the effective elution of template and fast adsorption/desorption kinetics, so only about 18 min was needed for MIP-coated SPME operation. The detection limits of 21–55 ng L−1 were achieved for four Sudan dyes, when MIP-coated SPME was coupled with liquid chromatography (LC) and mass spectrometry (MS) detection. The MIP-coated SPME–LC–MS/MS method was tested for the monitoring of ultra trace Sudan dyes in spiked chilli tomato sauce and chilli pepper samples, and high enrichment effect, remarkable matrix peaks-removing capability, and consequent high sensitivities were achieved to four Sudan dyes.  相似文献   

2.
Sudan dyes are a family of lipophilic azo dyes, extensively used in industrial and scientific applications but banned for use as food colorants due to their carcinogenicity. Due to the continuing illicit use of Sudan dyes as food colorants their determination in different food matrices – especially in different chilli and tomato sauces and related products – has during the recent years received increasing attention all over the world. This paper critically reviews the published determination methods of Sudan I–IV dyes. LC–UV–vis and LC–MS are the dominating methods for analysis of Sudan I–IV dyes. Sudan dyes are usually found in food at mg kg−1 levels at which it may be necessary to use a preconcentration step in order to attain the desired detection limits. Liquid–solid extraction is the dominating sample preparation procedure. In recent years it has been supplemented by ultrasonic-assisted extraction and pressurized liquid extraction. Various solid phase extraction types have been used for sample cleanup. The large majority of works use conventional C18 columns and conventional LC eluents. Traditionally the UV–vis absorbance detection has been the most frequently used. In the recent years MS detection is applied more and more often as it offers more reliable identification possibilities.  相似文献   

3.
Tianhe Jiang  Baolin Chu  Wei Yan 《Talanta》2009,78(2):442-447
A molecularly imprinted polymer (MIP) has been synthesized by a thermo-polymerization method using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, acetonitrile as porogenic solvent, and 17β-estradiol as template. The MIP showed obvious affinity for 17β-estradiol in acetonitrile solution, which was confirmed by absorption experiments. After optimization of molecularly imprinted solid-phase extraction (MISPE) conditions, three structurally related estrogenic compounds (17β-estradiol, estriol, and diethylstilbestrol) were used to evaluate the selectivity of the MIP cartridges. The MIP cartridges exhibited highly selectivity for E2, the recoveries were 84.8 ± 6.53% for MIPs and 19.1 ± 1.93% for non-imprinted polymer (NIP) cartridges. The detection and quantification limits correspond to 0.023 and 0.076 mg L−1. Furthermore, the MISPE methods were used to selectively extract E2 from fish and prawn tissue prior to HPLC analysis. This MISPE-HPLC procedure could eliminate all matrix interference simultaneously and had good recoveries (78.3-84.5%).  相似文献   

4.
A simple and rapid analytical method based on in-matrix ethyl chloroformate (ECF) derivatization has been developed for the quantitative determination of bisphenol-A (BPA) in milk and water samples. The samples containing BPA were derivatised with ECF in the presence of pyridine for 20 s at room temperature, and the non-polar derivative thus formed was extracted using polydimethylsiloxane solid-phase microextraction (SPME) fibres with thicknesses of 100 μm followed by analysis using gas chromatography–mass spectrometry. Three alkyl chloroformates (methyl, ethyl and isobutyl chloroformate) were tested for optimum derivatisation yields, and ECF has been found to be optimum for the derivatisation of BPA. Several parameters such as amount of ECF, pyridine and reaction time as well as SPME parameters were studied and optimised in the present work. The limit of detection for BPA in milk and water samples was found to be 0.1 and 0.01 μg L−1, respectively, with a signal-to-noise ratio of 3:1. The limit of quantitation for BPA in milk and water was found to be 0.38 and 0.052 μg L−1, respectively, with a signal-to-noise ratio of 10:1. In conclusion, the method developed was found to be rapid, reliable and cost-effective in comparison to silylation and highly suitable for the routine analysis of BPA by various food and environmental laboratories.  相似文献   

5.
Urinary 8-hydroxy-2′-deoxyguanosine (8-OHdG) has been widely used as a biomarker of oxidative DNA damage. Measurements of 8-OHdG in urinary samples are challenging owing to the low level of 8-OHdG and the complex matrix. In this study, a novel molecularly imprinted polymer (MIP) monolithic column was synthesized with guanosine as a dummy template which was used as the medium for in-tube solid-phase microextraction (SPME). In-tube SPME coupled with HPLC/UV detection for extraction and determination of urinary 8-OHdG was developed. The synthesized MIP monolithic column exhibited high extraction efficiency owing to its greater phase ratio with convective mass transfer and inherent selectivity. The enrichment factor for 8-OHdG was found to be 76 and the limits of detection and quantification of the method for urinary samples were 3.2 nmol/L (signal-to-noise ratio 3) and 11 nmol/L (signal-to-noise ratio 10), respectively. The MIPs selectivity also made the sample preparation procedure and chromatographic separation much easier. The linear range of the proposed method was from 0.010 to 5.30 μmol/L (r = 0.9997), with a relative standard deviation of 1.1–6.8%, and the recovery for spiked urine samples was 84 ± 3%. The newly developed method was successfully applied to determine urinary samples of healthy volunteers, coking plant workers, and cancer patients. The 8-OHdG level in cancer patients was significantly higher than that in healthy people.  相似文献   

6.
An improved multiple co-polymerization technique was developed to prepare a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber with propranolol as template. Investigation was performed for the characteristics and application of the fibers. The MIP coating was highly crosslinked and porous with the average thickness of only 25.0 μm. Consequently, the adsorption and desorption of β-blockers within the MIP coating could be achieved quickly. The specific selectivity was discovered with the MIP-coated fibers to propranolol and its structural analogues such as atenolol, pindolol, and alprenolol. In contrast, only non-specific adsorption could be shown with the non-imprinted polymer (NIP)-coated fibers, and the extraction efficiencies of propranolol and pindolol with the MIP-coated fibers were higher markedly than that with the commercial SPME fibers. A MIP-coated SPME coupled with high-performance liquid chromatography (HPLC) method for propranolol and pindolol determination was developed under the optimized extraction conditions. Linear ranges for propranolol and pindolol were 20–1000 μg L−1 and detection limits were 3.8 and 6.9 μg L−1, respectively. Propranolol and pindolol in the spiked human urine and plasma samples, extracted with organic solvent firstly, could be simultaneous monitored with satisfactory recoveries through this method.  相似文献   

7.
A restricted access media–molecularly imprinted polymer (RAM–MIP) for cyclobarbital has been developed for selective extraction of antiepileptics in river water samples. The RAM–MIP was prepared using 4-vinylpyridine and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and polymerization method followed by a surface modification technique. The RAM–MIP for cyclobarbital showed molecular recognition abilities for phenobarbital, amobarbital and phenytoin as well as cyclobarbital. Thus, selective analysis of antiepileptics in river water samples was attained with RAM–MIP extraction followed by column-switching liquid chromatography–tandem mass spectrometry. The concentrations of phenobarbital and phenytoin in river water samples were about 15 and 4 ng/L, respectively, while that of amobarbital was below the limit of quantitation.  相似文献   

8.
9.
A simple, precise and accurate method for the simultaneous determination of four UV filters and five polycyclic musks (PCMs) in aqueous samples was developed by solid-phase microextraction coupled with gas chromatography–mass spectrometry (SPME-GC–MS). The operating conditions affecting the performance of SPME-GC–MS, including fiber thickness, desorption time, pH, salinity, extraction time and temperature have been carefully studied. Under optimum conditions (30 μm PDMS fiber, 7 min desorption time, pH 7, 10% NaCl, 90 min extraction time at 24 °C), the correlation coefficients (r2) of the calibration curves of target compounds ranged from 0.9993 to 0.9999. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.2 to 9.6 ng L−1 and 0.7 to 32.0 ng L−1, respectively. The developed procedure was applied to the determinations of four UV filters and five PCMs in river water samples and internal standard was used for calibration to compensate the matrix effect. Good relative recoveries were obtained for spiked river water at low, medium and high levels. The proposed SPME method was compared with traditional SPE procedure and the results found in river water using both methods were in the same order of magnitude and both are quite agreeable.  相似文献   

10.
A new simple and rapid dispersive liquid–liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 µL) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 µg L?1and the relative standard deviation (RSD, n = 5) for 50 µg L?1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples.  相似文献   

11.
A novel liquid–liquid–solid microextraction (LLSME) technique based on porous membrane-protected molecularly imprinted polymer (MIP)-coated silica fiber has been developed. In this technique, a MIP-coated silica fiber was protected with a length of porous polypropylene hollow fiber membrane which was filled with water-immiscible organic phase. Subsequently the whole device was immersed into aqueous sample for extraction. The LLSME technique was a three-phase microextraction approach. The target analytes were firstly extracted from the aqueous sample through a few microliters of organic phase residing in the pores and lumen of the membrane, and were then finally extracted onto the MIP fiber. A terbutylazine MIP-coated silica fiber was adopted as an example to demonstrate the feasibility of the novel LLSME method. The extraction parameters such as the organic solvent, extraction and desorption time were investigated. Comparison of the LLSME technique was made with molecularly imprinted polymer based solid-phase microextraction (MIP-SPME) and hollow fiber membrane-based liquid-phase microextraction (HF-LPME), respectively. The LLSME, integrating the advantages of high selectivity of MIP-SPME and enrichment and sample cleanup capability of the HF-LPME into a single device, is a promising sample preparation method for complex samples. Moreover, the new technique overcomes the problem of disturbance from water when the MIP-SPME fiber was exposed directly to aqueous samples. Applications to analysis of triazine herbicides in sludge water, watermelon, milk and urine samples were evaluated to access the real sample application of the LLSME method by coupling with high-performance liquid chromatography (HPLC). Low limits of detection (0.006–0.02 μg L−1), satisfactory recoveries and good repeatability for real sample (RSD 1.2–9.6%, n = 5) were obtained. The method was demonstrated to be a fast, selective and sensitive pretreatment method for trace analysis of triazines in complex aqueous samples.  相似文献   

12.
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage. Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results. Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity (detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds were identified and quantified.   相似文献   

13.
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) with fluorescence detection was optimized for extraction and determination of four benzimidazole fungicides (benomyl, carbendazim, thiabendazole, and fuberidazole) in water. We studied extraction and desorption conditions, for example fiber type, extraction time, ionic strength, extraction temperature, and desorption time to achieve the maximum efficiency in the extraction. Results indicate that SPME using a Carboxen–polydimethylsiloxane 75 μm (CAR–PDMS) fiber is suitable for extraction of these types of compound. Final analysis of benzimidazole fungicides was performed by HPLC with fluorescence detection. Recoveries ranged from 80.6 to 119.6 with RSDs below 9% and limits of detection between 0.03 and 1.30 ng mL−1 for the different analytes. The optimized procedure was applied successfully to the determination of benzimidazole fungicides mixtures in environmental water samples (sea, sewage, and ground water).  相似文献   

14.
15.
A novel multiwalled carbon nanotubes–polyaniline composite (MWCNTs–PANI) film coated platinum wire was fabricated through electrochemical deposition. The coating was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry and thermogravimetry. It was found that the coating was porous and had large specific area and adsorption capacity; in the composite MWCNTs and polyaniline interacted with each other and the film kept stable up to 320 °C. The as-made fiber was used for the headspace solid-phase microextraction (HS-SPME) of some phenolic compounds (i.e. 2-chlorophenol, 2,4-dichlorophenol, 2-methylphenol, 3-methylphenol, 2,6-dimethylphenol, 2-nitrophenol), followed by gas chromatographic analysis. The MWCNTs–PANI coating showed better analytical performance than PANI. Under the optimized conditions, the detection limits were 1.89–65.9 ng L−1, the relative standard deviations (RSDs) were 2.7–6.5% for six successive measurements with single fiber, the RSDs for fiber-to-fiber were 5.2–12.4%, the linear ranges exceeded two magnitudes with correlation coefficient above 0.992. The fiber could be used for more than 250 times without decrease of efficiency. The proposed method was successfully applied to the extraction and determination of phenolic compounds in water sample, and the recoveries were 87.7–111.5% for different analytes. In addition, the fiber also presented advantages of easy preparation and low cost. Therefore, it is a promising SPME fiber.  相似文献   

16.
17.
A semi-automatic flow-based method for the simultaneous determination of 9 pharmaceuticals and 3 hormones in water samples in a single analytical run is proposed. The analytes were retained on a solid-phase extraction sorbent column and 1 μL of the eluate analysed by gas chromatography in combination with electron impact ionization mass spectrometry in the SIM mode. The sorbent used, Oasis-HLB, provided near-quantitative recovery of all analytes. The proposed method was validated with quite good analytical results including low limits of detection (0.01–0.06 ng L−1 for 100 mL of water) and good linearity (r2 > 0.993) throughout the studied concentration ranges. The method provided good accuracy (recoveries of 85–103%) and precision (between- and within-day RSD values less than 7%) in the determination of the pharmaceuticals and hormones in tap, river, pond, well, swimming pool and wastewater.  相似文献   

18.
Cytokinins (CTKs) are a class of growth-regulating hormones involved in various physiological and developmental processes. More novel analytical methods for the accurate identification and quantitative determination of trace CTKs in plants have been desired to better elucidate the roles of CTKs. In this work, a novel method based on monolithic molecularly imprinted solid-phase extraction followed by liquid chromatography–electrospray tandem mass spectrometry (mMI-SPE-LC-MS/MS) was developed for accurate determination of four CTKs in plant samples. The molecularly imprinted polymer monolith was prepared by using kinetin as the template in syringes and exhibited specific recognition ability for the four CTKs in comparison with that of non-imprinted polymer monolith. Several factors affecting the extraction performance of mMI-SPE, including the pH of loading sample solution, the nature and volume of elution solvent, the flow rate of sample loading, and sample volume, were investigated, respectively. Under the optimized conditions, the proposed mMI-SPE-LC-MS/MS method was successfully applied in the selective extraction and determination of four CTKs in plant tissues, and it offers detection limits (S/N?=?3) of 104, 113, 130, and 89 pg/mL and mean recoveries of 85.9%, 79.3%, 73.5%, and 70.1% for kinetin, kinetin glucoside, trans-zeatin, and meta-topolin (mT), respectively, with the corresponding RSDs less than 15%.
Figure
Trace determination of cytokinins in different plant samples by monolithic molecularly imprinted solid-phase extraction and liquid chromatography–mass spectrometry  相似文献   

19.
A fast and simple ultrasound-assisted dispersive liquid–liquid microextraction method for determination of Sodium Closantel has been developed. High-performance liquid chromatography with ultraviolet detector has been used for the determination of Sodium Closantel. The effect of influencing parameters such as type and volume of extraction and disperser solvents, pH of sample solution, extraction time and amount of salt was also investigated. Optimization of method was performed using Plackett–Burman experimental design and surface response methodology. Under the optimal conditions, the linear dynamic range of Sodium Closantel was from 10 to 3000 µg L?1 with a correlation coefficient of 0.997 and a detection limit of 1.0 µg L?1. The relative standard deviation was less than 3.5% (n = 5). The method has been successfully applied for determination of Sodium Closantel in real samples. The enrichment factor was 48 under optimal conditions.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号