首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Volatile organic compounds (VOCs) emitted from in vitro cultures may reveal information on species and metabolism. Owing to low nmol L−1 concentration ranges, pre‐concentration techniques are required for gas chromatography–mass spectrometry (GC–MS) based analyses. This study was intended to compare the efficiency of established micro‐extraction techniques – solid‐phase micro‐extraction (SPME) and needle‐trap micro‐extraction (NTME) – for the analysis of complex VOC patterns. For SPME, a 75 μm Carboxen®/polydimethylsiloxane fiber was used. The NTME needle was packed with divinylbenzene, Carbopack X and Carboxen 1000. The headspace was sampled bi‐directionally. Seventy‐two VOCs were calibrated by reference standard mixtures in the range of 0.041–62.24 nmol L−1 by means of GC–MS. Both pre‐concentration methods were applied to profile VOCs from cultures of Mycobacterium avium ssp. paratuberculosis. Limits of detection ranged from 0.004 to 3.93 nmol L−1 (median = 0.030 nmol L−1) for NTME and from 0.001 to 5.684 nmol L−1 (median = 0.043 nmol L−1) for SPME. NTME showed advantages in assessing polar compounds such as alcohols. SPME showed advantages in reproducibility but disadvantages in sensitivity for N‐containing compounds. Micro‐extraction techniques such as SPME and NTME are well suited for trace VOC profiling over cultures if the limitations of each technique is taken into account.  相似文献   

2.
A needle trap device (NTD) packed with silica composite of multi-walled carbon nanotubes (MWCNTs) prepared based on sol–gel technique was utilized for sampling and analysis of volatile organohalogen compounds (HVOCs) in air. The performance of the NTD packed with MWCNTs/silica composite as sorbent was examined in a variety of sampling conditions and was compared with NTDs packed with PDMS as well as SPME with Carboxen/PDMS-coated fibers. The limit of detection of NTDs for the GC/MS detection system was 0.01–0.05 ng mL−1 and the limit of quantitation was 0.04–0.18 ng mL−1. The RSD were 1.1–7.8% for intra-NTD comparison intended for repeatability of technique. The NTD-MWCNTs/silica composite showed better analytical performances compared to the NTD-PDMS composite and had the same analytical performances when compared to the SPME-Carboxen/PDMS fibers. The results show that NTD-MWCNTs-GC/MS is a powerful technique for active sampling of occupational/environmental pollutants in air.  相似文献   

3.
Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2–30 ml/min) and volume (10–100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1–5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.  相似文献   

4.
A needle‐trap device, with immobilized sorbent inside the syringe, coupled with GC–MS was applied for air sampling and determination of chlorinated volatile organic compounds such as dichloromethane, trichloromethane, and tetrachloromethane. The application of a needle trap packed with combination of three sorbents including Tenax TA, Carbopack X, and Carboxen 1000 resulted in detection limits of few pg for chlorinated volatile compounds and recoveries of 99.2–102.8%. The extraction and desorption parameters were optimized within the study. As a result, the precision determined as RSD was equal to 5.05 and 3.03 and 6.52% for dichloromethane, trichloromethane, and tetrachloromethane, respectively. The storage time for chlorinated compounds up to 48 h and reusability of the needle‐trap device were verified. The obtained results have proved the ability of needle traps to compete with other solventless sampling and sample preparation extraction techniques.  相似文献   

5.
A needle trap device (NTD) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from liquid samples followed by determination by gas chromatography–mass spectrometry (GC-MS). The extraction was performed using the dynamic sampling approach, in which a liquid sample was pumped through the system. Due to the flexibility and softness of graphene, its application in NTD may be difficult. Herein, the effectiveness of reduced graphene oxide (rGO) packed in NTD in dynamic extraction of PAHs was evaluated. Several experimental parameters, such as the adsorbent mass, eluent type and its volume, as well as the sample volume were optimized to achieve satisfactory performance for dynamic extraction. Comparative studies showed that the extraction performance of rGO-NTD was better than using NTDs packed with other sorbents such as activated carbon. The recovery rate for reduced graphene oxide exceeded 92%. Comparison of dynamic and headspace sampling showed comparable results but the dynamic mode is more suitable for field measurements. The recovery rates of PAHs spiked in water samples were from 76.5 to 100.2% and the relative standard deviation values were from 2.7 to 7.5% under the optimal conditions. This work reveals the potential of NTD with a graphene-based material for sample preparation before chromatographic analysis of liquid samples.  相似文献   

6.
Gaseous benzene, toluene, ethylbenzene and o‐xylene (BTEX) were extracted by using the divinylbenzene (DVB) particles (mesh sizes 60–80, 80–100 and 100–120) as sorbents packed in passive needle trap samplers (NTS). This study performed feasibility tests of these self‐designed DVB‐NTS as diffusive time‐weighted average (TWA) samplers and compared extraction efficiency with that of 100 mm polydimethylsiloxane‐solid phase microextration (PDMS‐SPME) fiber for sampling gaseous and particle‐bound volatile organic compounds (VOCs) from burning mosquito coils. Experimental results indicated that extraction rate of NTS is a reliable index in extracting VOCs. Additionally, comparisons of the NTS in extracting BTEX mass showed the NTS packed with the smallest diameters of adsorbent particles (100–120 mesh DVB) were the most effective. The mass of gaseous BTEX extracted by 100 μm PDMS‐SPME fiber were substantially lower than that extracted by DVB‐NTS of all meshes for the 30‐min TWA sampling of burning mosquito coils, and NTS packed with 100–120 mesh DVB adsorbed BTEX 50–120 ng BTEX. Particles clogging inside the packed phase of NTS inhibited VOC extraction performance after 3–5 samplings of burning particles, especially NTS packed with small‐diameter adsorbents.  相似文献   

7.
Lu CJ  Zellers ET 《The Analyst》2002,127(8):1061-1068
A small multi-adsorbent preconcentration/focusing module for a portable GC with microsensor-array detector designed to determine complex mixtures of volatile and semi-volatile organic compounds encountered in indoor working environments is described. Candidate adsorbents were assessed on the basis of analyte thermal-desorption bandwidth and efficiency, chromatographic peak shape, and breakthrough volume against mixtures of organic compounds ranging over four orders of magnitude in vapor pressure. A capillary packed with just 12.3 mg of adsorbent material comprising Carbopack B (8 mg), Carbopack X (2.5 mg) and Carboxen 1000 (1.8 mg) provided the best tradeoff in operating variables, while maintaining sufficient capacity for a 1 L air sample containing a mixture of up to 43 compounds, each at 100 parts-per-billion, at an ambient relative humidity of up to 100%. On-column focusing and temperature programming were used to enhance chromatographic separations, and detection limits as low as 100 parts-per-trillion were achieved for a 1 L air sample using an integrated array of polymer-coated surface-acoustic-wave (SAW) sensors. Implications for field analysis of indoor air quality are emphasized.  相似文献   

8.
For air/headspace analysis, needle trap devices (NTDs) are applicable for sampling a wide range of volatiles such as benzene, alkanes, and semi-volatile particulate bound compounds such as pyrene. This paper describes a new NTD that is simpler to produce and improves performance relative to previous NTD designs. A NTD utilizing a side-hole needle used a modified tip, which removed the need to use epoxy glue to hold sorbent particles inside the NTD. This design also improved the seal between the NTD and narrow neck liner of the GC injector; therefore, improving the desorption efficiency. A new packing method has been developed and evaluated using solvent to pack the device, and is compared to NTDs prepared using the previous vacuum aspiration method. The slurry packing method reduced preparation time and improved reproducibility between NTDs. To evaluate the NTDs, automated headspace extraction was completed using benzene, toluene, ethylbenzene, p-xylene (BTEX), anthracene, and pyrene (PAH). NTD geometries evaluated include: blunt tip with side-hole needle, tapered tip with side-hole needle, slider tip with side-hole, dome tapered tip with side-hole and blunt with no side-hole needle (expanded desorptive flow). Results demonstrate that the tapered and slider tip NTDs performed with improved desorption efficiency.  相似文献   

9.
Solid-phase micro-extraction (SPME) was studied as a solvent free alternative method for the extraction and characterization of volatile compounds in intact and plucked flowers of Jasminum sambac at different day time intervals using gas chromatography (GC-FID) and gas chromatography-quadrupole mass spectrometry. The analytes identified included alcohols, esters, phenolic compounds, and terpenoids. The main constituents identified in the flower aroma using different fibers were cis-3-hexenyl acetate, (E)-beta-ocimene, linalool, benzyl acetate, and (E,E)-alpha-farnesene. The benzyl acetate proportion decreased from morning to afternoon and then increased in evening collections. PDMS fiber showed a high proportion of (E,E)-alpha-farnesene in jasmine floral aroma. Among other constituents identified, cis-3-hexenyl acetate, linalool, and benzyl acetate were major aroma contributors in plucked and living flowers extracts using PDMS/DVB, Carboxen/PDMS, and DVB/Carboxen/PDMS fibers. PDMS/DVB recorded the highest emission for benzyl acetate while the (E)-beta-ocimene proportion was highest in DVB/Carboxen/PDMS when compared with the rest. The highest linalool content, with increasing proportion from morning to noon, was found using mixed coating fibers. Almost negligible volatile adsorption was recorded for the polyacrylate fiber for intact flower aroma, whereas it was most effective for benzyl acetate, followed by indole under plucked conditions. Moreover, the highest amounts extracted, evaluated from the sum of peak areas, were achieved using Carboxen/PDMS, and DVB/Carboxen/PDMS. Introduction of a rapid, and solvent free SPME method for the analysis of multicomponent volatiles can be successfully employed to monitor the extraction and characterization of flower aroma constituents.  相似文献   

10.
Different capillary needle trap (NT) configurations are studied and compared to evaluate the suitability of this methodology for screening in the analysis of volatile organic compounds (VOCs) in air samples at ultra-trace levels. Totally, 22 gauge needles with side holes give the best performance and results, resulting in good sampling flow reproducibility as well as fast and complete NT conditioning and cleaning. Two different types of sorbent are evaluated: a graphitized carbon (Carbopack X) and a polymeric sorbent (Tenax TA). Optimized experimental conditions were desorption in the GC injector at 300°C, no make-up gas to help the transport of the desorbed compounds to the GC column, 1 min splitless time for injection/desorption, and leaving the NT in the hot injector for about 20 min. Cross-contamination is avoided when samples containing high VOC levels (above likely breakthrough values) are evaluated. Neither carryover nor contamination is detected for storage times up to 48 h at 4°C. The method developed is applied for the analysis of indoor air, outdoor air and breath samples. The results obtained are equivalent to those obtained with other thermal desorption devices but have the advantage of using small sample volumes, being simpler, more economical and more robust than conventional methodologies used for VOC analysis in air samples.  相似文献   

11.
In this paper solid phase microextraction (SPME) and needle trap device (NTD) as two in-progress air monitoring techniques was applied with silylated composite of carbon nanotubes for sampling and analysis of perchloroethylene in air. Application of SPME and NTD with proposed nano-structured sorbent was investigated under different laboratory and experimental parameters and compared to the SPME and NTD with CAR/PDMS. Finally the two samplers contained nano-sorbent used as a field sampler for sampling and analysis of perchloroethylene in dry cleaning. Results revealed that silica composite form of CNTs showed better performance for adsorbent of perchloroethylene. SPME and NTD with proposed sorbent was demonstrated better responses in lower levels of temperature and relative humidity. For 5 days from sampling the relative responses were more than 97% and 94% for NTD and SPME, respectively. LOD were 0.023 and 0.014 ng mL−1 for SPME coated CNTs/SC and CAR/PDMS, and 0.014 and 0.011 ng mL−1 for NTD packed with CNTs/SC and CAR/PDMS, respectively. And for consecutive analysis RSD were 3.9–6.7% in laboratory and 4.43–6.4% in the field. In the field study, NTD was successfully applied for determining of the PCE in dry cleaning. The results show that the NTD packed with nanomaterial is a reliable and effective approach for the sampling and analysis of volatile compounds in air.  相似文献   

12.
Solid-phase microextraction (SPME) fibers with supported fluorinated glassy carbon are demonstrated for the first time. Oligo[1,3-dibutadiynylene-1,3-(tetrafluoro)phenylene] was synthesized and heated to temperatures that varied from 200 to 1000 degrees C to produce the fluorinated glassy carbon. The extent of graphitization of the glassy carbon increased as the processing temperature increased. The fluorinated glassy carbon selectively extracted monohalogenated benzenes from an aqueous solution when compared to the extraction of toluene. The selectivity increased in the order of phi-F < phi-Cl < phi-Br < phi-I. The selectivity for the halogenated compounds was greatest for the fluorinated glassy carbon phase processed at temperature below approximately 400 degrees C. Preliminary studies on the retention mechanism of the LTGC phase show that dispersive interactions are very important to the retention of halocarbons on the fluorinated LTGC. Finally, the selectivity of the fluorinated LTGC for halogenated compounds was compared to that of commercially available SPME fibers, such as poly(dimethylsiloxane), poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB), and poly(dimethylsiloxane)/Carboxen (PDMS/Carboxen) fibers. As expected the fluorinated LTGC was more selectivity for the halogenated compounds. Interestingly the order of the increase in selectivity is opposite when comparing the fluorinated-LTGC and the three commercial fibers. A decrease in selectivity was observed going from fluorobenzene to iodobenzene using PDMS/DVB and PDMS/Carboxen fibers. While for the pure PDMS phase, there is a slight increase in selectivity from fluorobenzene to chlorobenzene but the remaining trend shows little change for bromobenzene and iodobenzene.  相似文献   

13.
Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography–mass spectrometry (GC–MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.  相似文献   

14.
Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels.  相似文献   

15.
赵金凤  王希越  娄大伟 《化学通报》2024,87(4):410-418,397
随着检测需求的提高与分析技术的发展,简单、自动化、环保与小型化的微型样品前处理技术越来越受到关注。针阱微萃取(NTME)是在固相微萃取(SPME)技术的理论基础上发展起来的一种新型微型萃取技术,其萃取装置将吸附剂填充到不锈钢针内制得,可避免固相微萃取纤维易碎及涂层脱落的问题,而且通过动态萃取,可使目标物被彻底萃取,具有更好的耐用性和富集能力。近年NTME结合气相色谱法在挥发性和半挥发性有机污染物分析中获得广泛应用,已有诸多关于NTME的研究被报道。吸附剂是影响NTME萃取性能的核心,本文简要概述了近年NTME的吸附剂种类,并综述了其在环境、食品、生物领域的应用进展。  相似文献   

16.
The organic volatile flavor compounds in fermented stinky tofu (FST) were studied using SPME-GC/MS. A total of 39 volatile compounds were identified, including nine esters, seven alcohols, five alkenes, four sulfides, three heterocycles, three carboxylic acids, three ketones, two aldehydes, one phenol, one amine and one ether. These compounds were determined by MS, and conformed by comparison of the retention times of the separated constituents with those of authentic samples and by comparison of retention indexes (RIs) of separated constituents with the RIs reported in the literature. The predominant volatile compound in FST was indole, followed by dimethyl trisulfide, phenol, dimethyl disulfide and dimethyl tetrasulfide. In order to find a better extraction time, the extraction times was optimized for each type of SPME fiber; the results show that the best extraction time for Carboxen/PDMS is 60 min, for PDMS/DVB 30 min, for DVB/CAR/PDMS 60 min and for PDMS 75 min. Of the four fibers used in this work, Carboxen/PDMS is found to be the most suitable to extract the organic volatile flavor compounds in fermented stinky tofu.  相似文献   

17.
Lärstad M  Loh C  Ljungkvist G  Olin AC  Torén K 《The Analyst》2002,127(11):1440-1445
A method for the determination of exhaled ethane, pentane and isoprene was developed and validated. The method was based on pre-concentration of the analytes on a multi-bed solid adsorbent tube containing Tenax TA, Carboxen 569 and Carboxen 1000, thermal desorption and gas chromatography (GC) with flame ionisation detection (FID). A pre-column in an end-cut GC system was used to avoid problems with water and strongly retained substances. The detection limits were 5, 2 and 6 pmol per sample for ethane, pentane and isoprene, respectively, using a sample volume of 500 ml. The linearity was good for all analytes with correlation coefficients exceeding 0.999. The repeatability for exhaled air samples was 7, 10 and 12% for ethane, pentane and isoprene, respectively. Analysis of a certified reference material of ethane and pentane did not differ significantly from the certified values. Ethane and pentane levels were stable up to six days of storage in sample tubes. Isoprene levels were not stable during storage in the sample tubes used here, but using Carbopack X instead of Carboxen 569, levels were stable up to two days. The levels of exhaled ethane, pentane and isoprene in healthy subjects (n = 4) were 8.1+/-5.8 pmol l(-1), 11+/-5.8 pmol l(-1) and 2.4+/-0.90 mnol l(-1), respectively. The method could, with minor modifications, be used to determine other low-molecular hydrocarbons in exhaled air as well.  相似文献   

18.
A method was developed for the determination of trichloroanisole, tribromoanisole and pentachloroanisol by solid-phase microextraction and gas chromatography in paper samples (Kraft liner, Test liner and Miolo). Four commercial SPME fibers were evaluated: Polydimethylsiloxane (PDMS), Polyacrylate (PA), Carbowax/Divinylbenzene (CW/DVB) and Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS). DVB/CAR/PDMS gave the best results and was therefore selected. Other variables involved in the extraction procedure were studied and optimized, such as: sample volume, salting-out effect, temperature and extraction time, effect of organic solvent and previous sample preparation. Optimum conditions were obtained using 20 mL of sample with 5 mol L−1 NaCl in a 40 mL vial, extraction temperature of 70 °C and sonication and extraction time of 30 and 40 min, respectively. Detection limits ranged from 0.43 to 1.32 ng g−1 for all analytes. Recoveries between 70 and 100% were obtained and relative standard deviation was below 10% for all compounds.  相似文献   

19.
Needle trap devices (NTDs) are improving in simplicity and usefulness for sampling volatile organic compounds (VOCs) since their first introduction in early 2000s. Three different sample transfer methods have been reported for NTDs to date. All methods use thermal desorption and simultaneously provide desorptive flow to transfer desorbed VOCs into a GC separation column. For NTDs having 'side holes', GC carrier gas enters a 'side hole' and passes through sorbent particles to carry desorbed VOCs, while for NTD not having a 'side hole', clean air as desorptive flow can be provided through a needle head by a air tight syringe to sweep out desorbed VOCs or water vapor has been reported recently to be used as desorptive flow. We report here a new simple sample transfer technique for NTDs, in which no side holes and an external desorptive flow are required. When an NTD enriched by a mixture of benzene, toluene, ethylbenzene, and xylene (BTEX) or n-alkane mixture (C6-C15) is exposed to the hot zone of GC injector, the expanding air above the packed sorbent transfers the desorbed compounds from the sorbent to the GC column. This internal air expansion results in clean and sharp desorption profiles for BTEX and n-alkane mixture with no carryover. The effect of desorption temperature, desorption time, and overhead volumes was studied. Decane having vapor pressure of approximately 1 Torr at 20 degrees C showed approximately 1% carryover at the moderate thermal desorption condition (0.5 min at 250 degrees C).  相似文献   

20.
Adsorption of water vapour from humid air by selected carbon adsorbents   总被引:2,自引:0,他引:2  
The water uptake by carbon molecular sieves (CMS) and graphitized carbons, all of which are used to determine volatile organic compounds in air, was investigated using a direct experimental approach. CMS, e.g. Carboxen 1002, Carboxen 1003 and Anasorb CMS adsorb substantial amounts of water, in the range 400 to 450 mg per gram of adsorbent. Graphitized carbons, e.g. Carbrogaph 5TD and Carbopack X show low water trapping, less than 30 mg g(-1) and Carbopack Y as little as 5 mg g(-1) or less. The water sorption capacity for graphitized carbons is strongly dependent on the relative humidity (RH). The change of RH from 95 to 90% decreases the amount of adsorbed water by more than a factor of 2. Two different water adsorption mechanisms are operative: adsorption on polar centers and micropore volume filling. For graphitized carbons and CMS at low RH, adsorption on polar centers is involved. For CMS, once the threshold value of relative humidity (RHth) is surpassed, micropore volume filling becomes predominant. RHth is 44 +/- 3 and 42 +/- 3% for Carboxen 1002 and 1003, respectively, and 32 +/- 3% for Anasorb CMS. The CMS mass in the trap was found not to affect the mass of retained water under condition of incomplete saturation of adsorbent bed with water. Thus, the restrictions commonly imposed on the CMS mass are not necessary. The dry purging technique is suggested to remove adsorbed water. Carbograph 5TD and Carbopack X require only a few hundred ml of dry air to remove adsorbed water entirely. Water can also be purged out from CMS; however, much larger volumes of dry air are needed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号