首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have developed a molecularly imprinted polymer (MIP) electrochemical sensor for entacapone (ETC) based on an electropolymerised polyphenylenediamine (Po-PD) on a glassy carbon electrode (GCE) surface. The direct electropolymerisation of the o-phenylenediamine monomer (o-PD) was carried out with ETC as a template. The steps of electropolymerization process, template removal and binding of the analyte were tested by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/[Fe(CN)6]4 − as a redox probe. The operation of the sensor has been investigated by differential pulse voltammetry (DPV). Under optimal experimental conditions, the response of the DPV was linearly proportional to the ETC concentration between 1.0×10−7 and 5.0×10−6 M ETC with a limit of detection (LOD) of 5.0×10−8 M. The developed sensor had excellent selectivity without detectable cross-reactivity for levodopa and carbidopa. The MIP sensor was successfully used to detect ETC in spiked human serum samples.  相似文献   

2.
An all solid state potentiometric sensor using anthracene thiourea derivative as ionophore was developed. It exhibited a near‐Nernstian slope of 30.8±1.0 mV/decade of activity for HPO42? ions in the concentration range of 1.0×10?7–1.0×10?3 M at pH 7.4. It displayed excellent selectivity for monohydrogen phosphate over other anions and the selectivity sequence was determined as HPO42?>SO42?>Cl?>NO3?>OAc?>I?>ClO4?. The developed sensor was evaluated for the analysis of monohydrogen phosphate ions in a standard reference material (SRM 1548) as well as in the potentiometric titration of phosphate ions with a barium chloride solution.  相似文献   

3.
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with −81.7 ± 1.7 (r2 = 0.9986) and −146.2 ± 2.3 mV/decade (r2 = 0.9991) slopes over the linearity range 1.5 μM–1.5 mM with 0.8 and 1.0 μM detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)6]−3/−4 redox-active electrolyte. Sensors achieved detection limits of 4.3 × 10−8 and 1.8 × 10−7 M over the linear ranges of 5.2×10−8–1.0×10−4 M and 1.4×10−6–1.4×10−3 M, with 0.09 ± 0.004 and 0.168 ± 0.009 log Ω/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.  相似文献   

4.
《中国化学会会志》2017,64(7):860-868
One‐pot electrodeposited copper‐graphene (Cu‐GE ) nanocomposite acting as sacrificial template for the division electrosynthesis of palladium nanoparticles (PdNPs ) on pyrolytic graphite electrode (PGE ) was synthesized. The designed PdNPs‐GE nanocomposite was evaluated as a new material for highly sensitive determination of hydrazine (N2H4 ). Scanning electron microscopy revealed that the PdNP‐GE ‐modified PGE had uniform morphology. The results of energy‐dispersive X‐ray spectrograms confirmed the ingredients of the division electrosynthesis process. Electrochemical experiments were performed to characterize the sensing properties of PdNPs‐GE toward the electrocatalytic oxidation of N2H4 at 0.20 V in sodium phosphate buffered saline (0.1 M pH 7.0). The sensor showed fast response (<3 s), high sensitivity [398 (1 × 10−6 A) (1 × 10−3 M)−1], and broad linearity in the range 2.5 × 10−8–2.7 × 10−4 M with a relatively low detection limit of 1.0 × 10−8 M (S/N = 3).  相似文献   

5.
In this study, for the first time, the electro-polymerization of Direct blue15 (DB15), an azo dye, was carried out on the surface of ITO. Furthermore, the poly(DB15) surface was electrochemically decorated with Ag nanoparticles (AgNPs), and the fabricated AgNPs/PDB15 electrodes were examined as nitrate sensors. Compared to unmodified ITO electrode, the AgNPs/PDB15 electrode had greatly improved electrochemical response to nitrate reduction. The nitrate determination in a linear range from 1.0×10−5 mol L−1 to 2.27×10−3 mol L−1 was performed with a detection limit of 9.66 μM. The synthesized electrode is a promising sensor for the electrochemical detection of nitrate pollutants in water.  相似文献   

6.
《Electroanalysis》2017,29(9):2138-2146
Mefloquine (MQ) is a quinoline based antimalarial drug, which is potent against multiple drug‐resistant Plasmodium falciparum . It is widely prescribed for the prophylactic treatment of malaria. Due to extensive usage of MQ, constant monitoring of the drug level in human body is of paramount importancein order to ensure that optimum drug exposure is achieved. The present work describes a gold nanourchins (AuNUs) based electrochemical sensor for the determination of MQ.AuNUs were synthesized via seed‐mediated method and characterized using ultraviolet‐visible spectroscopy, energy‐dispersive X‐ray spectroscopy, field emission scanning electron microscopy, zeta‐sizer and electrochemical techniques (electrochemical impedance spectroscopy and cyclic voltammetry). Fabrication of the sensor was done by drop‐coating the synthesized AuNUs onto a glassy carbon electrode. The fabricated sensor exhibited enhanced voltammetric response, which was attributed to the excellent conductivity and high surface area of AuNUs. Under optimum square wave voltammetric conditions, the sensor displayed two linear response ranges (from 2.0×10−9 to 1.0×10−6 M and from 1.0×10−6 to 1.0×10−3 M) with a detection limit of 1.4 nM. The electrode demonstrated good reproducibility, stability and selectivity over common interferents. The utility of the sensor was successfully assessed for quantification of the drug in pharmaceutical preparation and spiked human urine sample. Thus, the present study demonstrates a promising approach for determination of MQ with practical utility in quality control and clinical analysis.  相似文献   

7.
Sevgi Güney 《Electroanalysis》2023,35(7):e202200477
The electrochemical sensing of ornidazole (OR) was achieved with a highly selective sensor fabricated by a combination of an electrochemically reduced graphene oxide (ERGO) and molecularly imprinted polydopamine (PDA). The sensor (OR-imp@PDA/ERGO/GCE) was synthesized by electrochemical polymerization of dopamine (DA) on ERGO modified glassy carbon electrode (GCE). The analytical response of the sensor changed linearly with OR concentration varying from 1.5 × 10−9 M to 1.0 × 10−8 M and 1.0 × 10−8 M to 2.0 × 10−7 M, and the detection limit was defined as 1.1 × 10−9 M. The proposed sensor ensured the highly sensitive detection of OR concentration because of the advantages of ERGO and molecularly imprinted PDA.  相似文献   

8.
A platform based on praseodymium doped dysprosium oxide-carbon nanofibers modified electrode was constructed for the simultaneous determination of SY and TAR. SEM, EDX and XRD techniques were utilized for characterizing the proposed material. The voltammetric behaviour and properties of SY and TAR were gradually improved at materials in order from CNFs to Dy2O3−CNFs and Pr6O11@Dy2O3−CNFs. The working range was found to be 1.0×10−9–3.5×10−8 M and 1.5×10−9–4.0×10−8 M for SY and TAR, respectively. The value of LOD was 3.12×10−10 M and 5.35×10−10 M for SY and TAR, respectively. The platform (Pr6O11@Dy2O3−CNFs/GCE) was successfully applied to the electroanalysis of samples.  相似文献   

9.
A multi-responsive Cd metal–organic framework {[Cd (ttpe)(H2O)(ip)]•4H2O•DMAC}n ( 1•4H 2 O•DMAC ) was synthesized using hydrothermal method (ttpe = 1,1,2,2-tetra(4-(1H-1,2,4-triazol-1-yl)phenyl)ethylene, ip = isophthalate, DMAC = N,N-dimethylacetamide), and characterized. 1 exhibits a 2D (4,4) network. The luminescent sensing experimrnts showed that 1•4H 2 O•DMAC as a new MOF luminescent sensor can detect Cr2O72−, CrO42−, MnO4, Cu2+, Ag+ and Fe3+ in aqueous solution with simultaneously high efficiency and high sensitivity. The quenching constants Ksv for Cr2O72−, CrO42−, MnO4, Cu2+, Ag+ and Fe3+ are 4.231 × 104 M−1, 2.471 × 104 M−1, 6.459 × 103 M−1, 7.617 × 103 M−1, 1.563 × 104 M−1 and 3.574 × 104 M−1, respectively. The detection limits are 0.094 μM for Cr2O72−, 0.108 μM for CrO42 − , 0.346 μM for MnO4, 0.302 μM for Cu2+, 0.221 μM for Ag + , and 0.100 μM for Fe3+. 1•4H 2 O•DMAC exhibits high photocatalytic efficiency for degradation of methylene blue under visible light irradiation.  相似文献   

10.
《Arabian Journal of Chemistry》2020,13(12):8708-8716
The determination of azathioprine (AZA), a mercaptopurine derivative, has attracted a particular attention in most researches. Herein, spectrofluorometric (I) and chemiluminescence (II) methods were successfully confirmed to estimate azathioprine (AZA) in bulk powder form and pharmaceutical preparation. The optimum conditions to improve the fluorescence and chemiluminescence intensity of AZA were investigated. The method (I) measured the native fluorescence intensity of AZA in methanol as solvent, without any addition. The micelle-enhanced fluorescence of AZA was affected by the surfactant addition, type of solvent, pH value, and the volume of sodium dodecyl sulfate (SDS). The method (II) consisted in the improvement of the weak signal of calcein–KMnO4 chemiluminescence system by introducing synthesized silver nanoparticles (AgNPs) in the presence of AZA. The analytical curves were linear in the concentrations range 5.0 × 10−8 − 1.0 × 10−4 M and 5.0 × 10−9 − 2.0 × 10−3 M with a detection limit equal to 1.5 × 10−9 M and 2.6 × 10 −10 M for techniques (I) and (II), respectively. The statistical analysis indicated no significant difference between the proposed and reported methods. The suggested techniques were successfully used to determine azathioprine in its tablet form and were validated according to ICH guidelines.  相似文献   

11.
A potentiometric sensor modified with a nanocomposite of montmorillonite sheets decorated with polyaniline nanofibers (MT-PANI-NFs) as an efficient electroactive material and tricresyl phosphate (TCP) as a solvent mediator has been developed for the estimation of clomipramine HCl (CLP.HCl). The optimum potentiometric performance of the sensor was achieved by mixing of MT-PANI-NFs : TCP : graphene with a ratio of 2.69 : 30.11 : 67.20 (% wt/wt). The sensor exhibited a Nernstian slope of 59.0±0.1 mV decade−1 over the concentration range of 1.0×10−5−1.0×10−2 mol L−1 with a theoretically calculated detection limit of 5.0×10−6 mol L−1. The sensor performance was scrutinized in terms of several factors including thermal stability, pH effect, response time and selectivity. As, it displayed a high thermal stability at various temperature degrees (10–60 °C) with pH independency in the range of 3.5–8.5. Additionally, the developed sensor exhibited a very rapid performance for CLP.HCl detection with a fast response time of 4 s and reflecting a superior selectivity towards CLP.HCl over the other interfering species. SEM (scanning electron microscope) was used as a characteristic tool for the investigation of the proposed graphene sensor surface. Furthermore, the graphene sensor has been efficiently used for CLP.HCl estimation in its pharmaceutical formulations.  相似文献   

12.
The oxidative behavior of 1-[1-(phenylmethyl)butyl]pyrrolidine, prolintane, was studied at a glassy carbon electrode using linear-sweep and differential-pulse voltammetry. The oxidation process was shown to be irreversible using 0.04 M Britton–Robinson buffer and was diffusion-adsorption controlled. Two voltammetric methods were developed for the determination of prolintane using different techniques: linear-sweep and differential-pulse voltammetry. The peak current varied linearly with prolintane concentrations in the range of 1.0 × 10−5 −2.5 × 10−4 M, with a detection limit of 8.5 × 10−6 and 4.0 × 10−6 M, and with relative standard deviations of 2.1 % and 3.1 %, respectively. The methods were applied to commercial preparations, giving relative errors less than 3.1 % and relative standard deviations lower than 4.8 % (n = 10). Determination of prolintane (down to the 8.5 × 10−8 M level) can be performed by using a preconcentration step prior to the determination by differential-pulse voltammetry in 0.04 M Britton–Robinson buffer (pH 8.0) with preconcentration potential of 0.0 V. The detection limit was found to be 6.2 × 10−8 M (4 min preconcentration) and the relative standard deviation for 2.5 × 10−7 M prolintane (n = 5) was 4.6 %. Applicability to human urine analysis is illustrated (recovery 98 ± 2 %). Standard additions method can be used to determine prolintane in real samples of urine.  相似文献   

13.
《中国化学会会志》2018,65(6):743-749
A glassy carbon electrode (GCE) modified with a copper‐based metal‐organic framework (MOF) [HKUST‐1, HKUST‐1 = Cu3(BTC)2 (BTC = 1,3,5‐benzenetricarboxylicacid)] was developed as a highly sensitive and simple electrochemical sensor for the determination of dopamine (DA). The MOF was prepared by a hydrothermal process, and the morphology and crystal phase of the MOF were characterized by scanning electron microscopy (SEM) and X‐ray diffraction (XRD), respectively. Meanwhile, the electrochemical performance was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the modified electrode showed excellent electrocatalytic activity and high selectivity toward DA. The linear response range was from 5.0 × 10−7 to 1.0 × 10−4 M and the detection limit was as low as 1.5 × 10−7 M. Moreover, the electrochemical sensor was used to detect DA in real samples with excellent results. MOF‐based sensors hold great promise for routine sensing applications in the field of electrochemical sensing.  相似文献   

14.
A molecularly imprinted polymer (MIP) sensor was successfully constructed on glassy carbon electrode for the determination of 1-naphthol (1-Nph). The sensor was constructed by electropolymerization on bare GCE in the presence of the target molecule. The recognition of 1-Nph was conducted indirectly using [Fe(CN)6]3−/4− as redox probe. The MIP sensor presented wide linear working range and limit of detection of 1.5×10−9 mol L−1. The MIP sensor was applied for the determination of 1-Nph in oilfield produced water. The results obtained showed good selectivity and sensitivity of the proposed sensor in terms of 1-Nph quantification.  相似文献   

15.
《Electroanalysis》2017,29(7):1794-1804
The sensitivity enhancing properties of sodium dodecyl sulphate (SDS) and multi‐walled carbon nanotubes (MWCNTs) were associated to construct a nanosensor based on carbon paste electrode (CPE) by adopting drop cast method. The drop cast method makes use of minimum modifier and the entire modified surface of the sensor is available for the analyte. Surface characterization of the electrodes was carried out using FE‐SEM and EDX. EIS was used for the electrochemical characterization. We report for the first time the electrochemical analysis based on the oxidation of the ‐OH group of a novel drug, alpha‐hydrazinonitroalkene ( I ) which was found to have antibacterial and antimicrobial properties. The electron transfer kinetic parameters such as the charge transfer coefficient α and heterogeneous rate constant k′ were calculated and they have been found to be 0.64 and 9.62 × 10−2 cm s−1 respectively. The linear response ranges for ( I ) obtained at this sensor are 1.0 × 10−7 M − 7.0 × 10−7 M and 1.0 × 10−6 M – 4.5 × 10−5 M with a detection limit of (7.03 ± 0.41) × 10−8 M (S/N=3). The interference study suggested that the sensor was free from 1000‐fold excess of UA in the determination of ( I ). It was important to note that the sensor completely eliminated Ascorbic acid (AA) signal which offered a significant analytical advantage for the determination of the drug at this sensor. The practical usefulness of the modified sensor was demonstrated by the analysis of ( I ) in blood serum.  相似文献   

16.
A composite graphite (CG) electrode modified with poly(2,6‐diaminopyridine) (PDAP) was used as solid state‐ion selective electrode for determination of mercury. The electrooxidation of monomer 2, 6 diaminopyridine (DAP) onto CG was accomplished from the 30 mM DAP in 5% H2SO4 and 0.5 M ZnSO4. The electrode displayed Nernstian response with slope of 28.4±1 mV decade−1 in concentration range of 1×10−6 to 1×10−1 M and in solution of pH 3–5. The limit of detection for electrode was 3×10−8 M with response time of 25 s. The electrode was also suitable as an indicator electrode in the potentiometric titration of Hg2+ with iodide.  相似文献   

17.
The influence of hydrogen phosphate (HPO42−) and molybdate ions (MoO42−) on the behavior of tin corrosion in 0.2 M maleic acid was compared using experimental and theoretical techniques. The experimental studies consisted of the electrochemical investigations (potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS)), along with the surface analytical techniques (SEM and EDX). Additionally, the theoretical analysis (the chemical quantum computations at MP4/SDD level of theory in the aqueous phase), was conducted. The experimental outcomes illustrated that the inhibition efficiency (η%) increases with the concentration of the inhibitors, reaching 88 % and 81 % at 2×10−2 M concentration of MoO42− and HPO42−, respectively. The potentiodynamic polarization curves revealed that HPO42− performance is a cathodic-type inhibitor, while MoO42− shows a mixed-type behavior. The increase in temperature decreased the η% values of both inhibitors. Based on surface analysis and thermodynamic study, the presence of the two inhibitors formed protective films on the tin surface through a physisorption mechanism. The chemical quantum computations using the complete fourth-order Møller Plesset perturbation theory (MP4 with SDD basis) method results outlined the favorable affinity of the investigated inorganic inhibitors to interact with the tin surface, which interprets the well-observed inhibition efficiencies.  相似文献   

18.
A comparison of the analytical performances of four different (bio)sensor designs in H2O2 determination is discussed. The (bio)sensor designs developed were based on the use of (i) multiwalled carbon nanotubes (MWCNT), zinc oxide nanoparticles (ZnONP), prussian blue (PB); (ii) MWCNT, ZnONP, PB and ionic liquid (IL); (iii) MWCNT, ZnONP and horseradish peroxidase (HRP) and (iv) MWCNT, ZnONP, HRP and IL modified glassy carbon electrode (GCE). A performance comparison of (bio)sensors showed that the one based on HRP/IL-MWCNT-ZnONP/GCE showed the best analytical characteristics with a linear dynamic range of 9.99×10−8–7.55×10−4 M, detection limit of 1.37×10−8 M and sensitivity of 17.00 μA mM−1.  相似文献   

19.
《Electroanalysis》2017,29(11):2579-2590
In this study, an electrochemical sensor was developed and used for selective determination of bisfenol‐A (BPA) by integrating sol‐gel technique and multi‐walled carbon nanotubes (MWCNTs) modified paste electrode. BPA bounded by covalently to isocyanatopropyl‐triethoxy silane (ICPTS) was synthesized as a new precursor (BPA‐ICPTS) and then BPA‐imprinted polymer (BPA‐IP) sol‐gel was prepared by using tetramethoxysilane (TMOS) and BPA‐ICPTS. Non‐imprinted polymer (NIP) sol‐gel was obtained by using TMOS and (3‐Aminopropyl) triethoxysilane. Both BPA‐IP and NIP sol‐gels were characterized by nitrogen adsorption‐desorption analysis, FTIR, SEM, particle size analyzer and optical microscope. Carbon paste sensor electrode was fabricated by mixing the newly synthesized BPA‐IP with MWCNTs, graphite powder and paraffin oil. The electrochemical characterization of the sensor electrode was achieved with cyclic and differential pulse voltammetric techniques. The response of the developed sensor under the most proper conditions was linear in BPA concentration range from 4.0×10−9 to 1.0×10−7 mol L−1 and 5.0×10−7 to 5.0×10−5 mol L−1 and the detection limit was 4.4×10−9 mol L−1. The results unclosed that the proposed sensor displayed high sensitivity and selectivity, superior electrochemical performance and rapid response to BPA.  相似文献   

20.
《Electroanalysis》2003,15(2):139-144
A highly selective and sensitive membrane electrode based on vanadyl salen complex (VS), which responds to monohydrogenphosphate (MHP) ions is described. The response of the sensor is Nernstian over the wide concentration range (1.0×10?1 ? 5.0×10?6 M) of MHP. The sensitivity of the electrode is high enough to permit the detection of as little as 0.6 μg/mL of MHP without any significant interference from high levels of other anions. The potentiometric selectivity coefficient data revealed negligible interference from 11 common anions. The electrode has a fast response time (<25 s), good slope stability at pH 8.2 for a period of at least eight weeks. It was successfully applied for the direct determination of monohydrogenphosphate in fertilizer and, as indicator electrode, in potentiometric titration of HPO42? ion with barium chloride.  相似文献   