首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
《Analytical letters》2012,45(17):2690-2704
A disposable immunosensor for the detection of Escherichia coli O157:H7 based on a multiwalled carbon nanotube–sodium alginate nanocomposite film was constructed. The nanocomposite was placed on a screen-printed carbon electrode, and horseradish peroxidase-labeled antibodies were immobilized to E. coli O157:H7 on the modified electrode to construct the immunosensor. The modification procedure was characterized by atomic force microscopy and cyclic voltammetry. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to E. coli O157:H7 in a concentration range of 103–1010 cfu/mL, with a relatively low detection limit of 2.94 × 102 cfu/mL (S/N = 3). This immunosensor exhibited satisfactory specificity, reproducibility, stability, and accuracy, making it a potential alternative tool for early assessment of E. coli O157:H7.  相似文献   

2.
A novel electrochemical immunosensor based on a magnetic glassy carbon electrode (MGCE) was developed for the quantitative determination of human immunoglobulin G (IgG). The immunosensing interface was fabricated by initially depositing silver nanoparticles on the MGCE surface and then immobilizing anti‐human IgG antibodies via the magnetic force between MGCE and Fe3O4 nanoparticles. The antibodies were covalently bonded to the amine‐functionalized Fe3O4 nanoparticles. Under optimal conditions, the magnetism‐assisted immunosensor exhibited a wide linear range from 0.1 pg/mL to 1.0 µg/mL with the detection limit of 0.05 pg/mL. Furthermore, the immunosensor displayed the advantages of good reproducibility and satisfactory stability.  相似文献   

3.
The exploitation of antibiotics has caused many side effects on the agriculture, environment, and human health. The existing methods have numerous shortcomings in determining gentamicin (GEN), a broad-spectrum antibiotic that causes nephrotoxicity and ototoxicity when found in excess. Here, an immunosensing platform to detect GEN using multiwalled carbon nanotubes (MWCNTs) and molybdenum disulfide (MoS2) nanocomposite, deposited electrophoretically on indium tin oxide (ITO) glass has been developed. A novel 2-D graphene analog MoS2@ MWCNTs nanocomposite was made via a facile and low-cost hydrothermal technique using l-cysteine to achieve remarkable electrochemical properties. Subsequently, a highly sensitive electrochemical immunosensor was fabricated by assembling monoclonal antibodies against gentamicin (anti-GEN) on a MoS2@MWCNTs modified ITO electrode. The hetero-nanostructure formed on the immunosensor surface appeared relatively good conductor for accelerating the electron transfer. GEN was determined on anti-GEN modified electrodes by utilizing the differential pulse voltammetry technique by measuring the difference in current owing to the transfer of electrons directly between the redox species and immunoelectrodes. Under optimal experimental conditions, the fabricated immunosensor had a wide linear detection range of 1 × 10?6–40 μg/mL, a high sensitivity of 13.55 μA (log μg/mL)?1 and a low limit of detection and limit of quantification of 0.039 μg/mL and 0.130 μg/mL, respectively. The developed immunosensor also exhibits high reproducibility, repeatability, and good selectivity against various interferences. This electrochemical immunosensor having MoS2 modified MWCNTs displays the excellent potential for the point-of-care device for GEN testing.  相似文献   

4.
Xiao‐Hong Fu 《Electroanalysis》2007,19(17):1831-1839
A new electrochemical immunosensor for the detection of carbohydrate antigen‐125 (CA125), a carcinoma antigen, was developed by immobilization CA125 antibody (anti‐CA125) on gold hollow microspheres and porous polythionine (PTH) modified glassy carbon electrodes (GCE). The gold hollow microspheres provided a biocompatible microenvironment for proteins, and greatly amplified the coverage of anti‐CA125 molecules on the electrode surface. The performance and factors influencing the immunosensor were investigated in detail. The detection is based on the current change before and after the antigen‐antibody interaction. Under optimal conditions, the amperometric changes were proportional to CA125 concentration ranging from 4.5 to 36.5 U/mL with a detection limit of 1.3 U/mL (at 3σ). The CA125 immunosensor exhibited good precision, high sensitivity, acceptable stability, accuracy and reproducibility. The as‐prepared immunosensors were used to analyze CA125 in human serum specimens. Analytical results suggest that the developed immunoassay has a promising alternative approach for detecting CA125 in the clinical diagnosis.  相似文献   

5.
A simple and portable electrochemical immunosensor for the detection of total prostate specific antigen (t‐PSA) in human serum was developed using a double‐layer nanogold particles and dendrimer‐functionalized polyvinyl chloride (PVC) membrane as immunosensing interface. To fabricate such a multifunctional PVC electrode, an o‐phenylenediaminedoped PVC membrane was initially constructed, then nanogold particles and poly(amidoamine) G4‐dendrimer with a sandwich‐type format were assembled onto the PVC membrane surface, and then t‐PSA antibodies (anti‐PSA) were adsorbed on the nanogold surface. The detection principle of the immunosensor is based on the change in the electric potential before and after the antigen‐antibody interaction. The experimental conditions and the factors influencing the performance of the immunosensor were investigated. Under optimal conditions, the proposed immunosensor exhibits good electrochemical behavior in the dynamic range of 0.5–18 ng/mL relative to t‐PSA concentration with a relative low detection limit of 0.1 ng/mL (S/N=3). The precision, reproducibility, and stability of the immunosensor are acceptable. In addition, 43 serum specimens were assayed by the as‐prepared immunosensor, and consistent results were obtained in comparison with those obtained by the standard enzyme‐linked immunosorbent assay (ELISA). Compared with the conventional ELISAs, the developed immunoassay system was simple and rapid without labeling and separation steps. Importantly, the immobilization and detection methodologies could be extended for the immobilization and detection of other biomarkers.  相似文献   

6.
A gravimetric technique is proposed for the determination of antibodies to Yersinia enterocolitica serovar O: 3 using a piezoelectric quartz crystal immunosensor based on immobilized lipopolysaccharides. Conditions are optimized and a procedure is developed for the flow-injection analysis of blood serum samples using the immunosensor as the detector. The detection limit for antibodies is found to be 1.3 μg/mL, RSD is 8%, and the analytical range is 3–100 μg/mL. The rapidity (the duration of analysis was no longer than 10 min) and the direct detection of the formed agglutinate without additional labeling are the advantages of the proposed technique.  相似文献   

7.
Rapid and accurate tracing of biomarkers is essential for early detecting and diagnosing of cancer. Therefore, a valid and convenient strategy needs to be developed for efficient monitoring of cancer biomarkers. Herein, we constructed a portable microfluidic electrochemical immunosensor based on three-dimensional reduced graphene oxide (3D rGO) doped with gold nanoparticles (Au NPs) for ultrasensitive determination of alpha-fetoprotein (AFP). The designed microfluidic chip, with the advantages of small injection volume, detachable structure and high integration, was fabricated by 3D printing, which only needed 9 μL of reagent to realize the high sensitivity detection. In addition, the 3D Au NPs-rGO composites with high specific surface area and electrons transfer capacity can effectively increase electroactive sites and enhance electrochemical signals. Benefiting from these features, the 3D Au NPs-rGO microfluidic electrochemical immunochip showed a wide detection range between 0.1 pg/mL–200 ng/mL and a best detection limit of 0.045 pg/mL with the high sensitivity of 175.008 μA (ng/mL)−1 cm−2. Meanwhile, the proposed immunosensor exhibited reliable AFP detection in human serum samples, which demonstrated that this portable smartphone-based microfluidic electrochemical immunosensor hold great promises in clinical detection and huge potential in personalized healthcare.  相似文献   

8.
Biofunctionalizing a simple and disposable graphene oxide-modified screen-printed carbon electrode with anti-interleukin-15 antibodies has been successfully demonstrated for the first time for the label-free electrochemical detection of interleukin-15, a biomarker of early HIV infection. To improve the electrochemical reactivity and introduce carboxylic groups on the surface of screen-printed carbon electrode, high-quality graphene oxide was used for the modification of screen-printed carbon electrode. With simple modification of the screen-printed carbon electrode, the device exhibited satisfactory sensitivity, selectivity, stability, reproducibility, and regenerability. The immunosensor provided a detection limit of 3.51?ng?mL?1 and a sensitivity of 0.5655?µA cm?2?mL?ng?1. The simply constructed immunosensor thus rendered promising device for immunoreactions on the surface of the electrode.  相似文献   

9.
In this work, a novel sandwich-type electrochemical immunosensor based on host-guest interaction was fabricated for the detection of alpha-fetoprotein (AFP). Due to the large specific surface area of multiwalled carbon nanotubes and the unique supramolecular recognition ability of β-cyclodextrins, ferrocenecarboxylic acid (Fc) was incorporated into this sensor platform by host-guest interaction to generate an electrochemical signal. And β-cyclodextrins functionalized silver supported adamantine-modified glucose oxidase (GOD-CD-Ag), was used as a label to improve the analytical performance of the immunosensor by the dual amplification strategy. The obtained GOD-CD-Ag conjugates could convert glucose into gluconic acid with the formation of hydrogen peroxide (H2O2). And then silver nanoparticles could in situ catalyze the reduction of the generated H2O2, dramatically improving the oxidation reaction of Fc. The developed immunosensor shows a wide linear calibration range from 0.001 to 5.0 ng/mL with a low detection limit (0.2 pg/mL) for the detection of AFP. The method, with ideal reproducibility and selectivity, has a wide application prospect in clinical research.  相似文献   

10.
闵丽根  袁若  柴雅琴  陈时洪  许阳  付萍 《化学学报》2008,66(14):1676-1680
采用纳米金(nano-Au)、多壁碳纳米管-纳米铂-壳聚糖的纳米复合物(MWNT-Pt-CS)及电子媒介体硫堇(Th)固载抗体制得高灵敏癌胚抗原免疫传感器.首先, 于壳聚糖溶液中用NaBH4还原H2PtCl6, 并将多壁碳纳米管分散于其中制得碳纳米管-纳米铂-壳聚糖纳米复合物, 并将其滴涂在玻碳电极上成膜; 然后, 吸附电子媒介体硫堇制得硫堇/碳纳米管-纳米铂-壳聚糖(Th/MWNT-Pt-CS)修饰电极.利用壳聚糖和硫堇分子中大量的氨基固定纳米金并吸附癌胚抗体(anti-CEA); 最后, 用辣根过氧化物酶(HRP)封闭活性位点从而制得高灵敏电流型免疫传感器.在优化的实验条件下, 该传感器响应的峰电流值与癌胚抗原(carcinoembryonic antigen)浓度在0.5~10和10~120 ng/mL的范围内保持良好的线性关系, 检测限为0.2 ng/mL.  相似文献   

11.
制备了基于金标记物诱导银沉积电化学溶出分析的超灵敏甲胎蛋白传感器。通过壳聚糖将多壁碳纳米管修饰在玻碳电极上,利用戊二醛共价固定捕获抗体制得传感器。通过夹心免疫反应,抗体功能化的纳米金被捕获到传感器表面并进一步诱导银沉积。沉积的纳米银可在KCl溶液中直接通过阳极溶出法进行分析,从而实现对α-甲胎蛋白的检测。利用甲胎蛋白作为模型分析物,在0.02~200μg/L范围内,电流强度随着甲胎蛋白的质量浓度呈线性降低(r=0.992 8),检出限(S/N=3)为8 ng/L。将该传感器用于3个血样中甲胎蛋白的测定,所得结果与电致化学发光法测定结果一致。该免疫传感器显示了良好的稳定性、重复性和准确度,在临床诊断中具有较好的应用前景。  相似文献   

12.
In this paper a Mg2Al‐Cl layered double hydroxide (Mg2Al‐LDH) modified carbon ionic liquid electrode (CILE) was prepared and further used for the electrochemical detection of rutin. Cyclic voltammograms of rutin on Mg2Al‐LDH/CILE were recorded with a pair of well‐defined redox peaks appeared in pH 2.5 phosphate buffer solution, which was ascribed to the electrochemical reaction of rutin. Due to the presence of Mg2Al‐LDH on the electrode surface, the redox peak currents increased greatly and the electrochemical parameters were calculated. Under the optimal conditions the oxidation peak current was proportional to rutin concentration in the range from 0.08 μmol L‐1 to 800.0 μmol L‐1 with the detection limit on 0.0255 μmol L‐1 (3σ). The fabricated electrode showed good reproducibility and stability, which was successfully applied to rutin tablet samples determination.  相似文献   

13.
巫远招  干宁  胡富陶  李天华  曹玉廷  郑磊 《分析化学》2011,39(11):1634-1640
采用Fe3O4(核)/ZrO2(壳)纳米磁珠(ZMPs)标记待测物识别抗体,并用HRP酶封闭和DNA链接,建立了一类新型的"珠链状"一维磁性纳米探针制备方法。将甲胎蛋白(AFP)一抗固定于纳米金修饰的玻碳电极表面,构建了免疫电极(GCE?AFP Ab1)。基于该电极和上述合成探针,通过双抗体夹心法测定免疫产物上HRP酶对过氧化脲(CP)氧化对苯二酚反应的催化电流,研制了一类基于一维纳米结构组装的夹心型安培免疫传感器。研究表明:此一维纳米结构探针不仅大大增加了酶在电极表面的富集量,成倍扩增了催化电流,显著提高了传感器的灵敏度,而且易于通过外磁场与背景液可控分离,简化了分析步骤,并提高了结果的重复性。此传感器对AFP检测的线性范围为0.01~25 mg/L;检出限达4 ng/L(3σ),并被用于人血清中痕量AFP的测定,结果满意。  相似文献   

14.
Cucumber mosaic virus (CMV) causes major losses to agricultural and horticultural crops around the world. Hence, a rapid assay for the detection of CMV which can be employed in both laboratory and field is essential. A portable electrochemical immunosensor system for the detection of CMV, based on immobilized CMV specific antibodies conjugated with gold nanoparticle was developed for this purpose. The conjugated antibodies were added with polymer and deposited onto carbon screen printed working electrodes. Optimization of the modified surface immunosensor was performed using sandwich immunoassay format (ELISA). The initial ELISA result for the standard curve development showed a limit of detection down to 0.1mg/mL. Subsequently, the immunosensor was tested for cross reactivity with other plant pathogens. The performance of the electrochemical immunosensor revealed that it has a high selectivity in sample matrix with other organism. This immunosensor provides a promising technology for simple and sensitive detection system that is essential in rapid detection of plant pathogens.  相似文献   

15.
A porous metal organic frameworks (MOFs) material (MIL-101) based on trivalent chromium skeleton were synthesized by hydrothermal synthesis method, and loaded with Au nanoparticles (Au NPs) to prepare Au NPs@MIL-101 composite materials which were used as a marker to label anti microcystin-LR (Anti-MC-LR). The composite materials have strong catalytic properties to the oxidation of ascorbic acid. Anti-MC-LR was immobilized on glassy carbon electrode surface using electrodeposition graphene oxide (GO) as a fixed matrix to construct a competitive microcystin-LR immunosensor.  相似文献   

16.
A label-free electrochemical immunosensor was developed for the ultra-sensitive detection of β-lactoglobulin (β-LG). The novel nanocomplex of carbon nanochips, colloidal gold nanoparticles and titanium dioxide nanoparticles TiO2/CNC/AuC were constructed on conducting polymer, chitosan, and were characterised using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). This nanocomplex interface was studied using cyclic voltammetry (CV) and showed great improvement at the gold electrode surface with enhanced electrochemical performance, sensitivity and selectivity for β-lactoglobulin. Under optimal parameters, the square wave voltammetry (SWV) response curve was determined from 0.01 pg/mL to 500 pg/mL using [Fe(CN)6]3−/4−] redox probe. The calibration plot illustrates a linear relationship between log β-LG concentration and SWV current, with the limit of detection determined to be 0.01 pg/mL. This immunosensor displayed high sensitivity, selectivity, reproducibility and stability, and can be utilised for the detection of β-LG in real food samples.  相似文献   

17.
Various sensor‐based immunoassay methods have been extensively developed for the detection of cancer antigen 15‐3 (CA 15‐3), but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. The aim of this work is to develop a simple and sensitive electrochemical immunoassay for CA 15‐3 in human serum by using nanogold and DNA‐modified immunosensors. Prussian blue (PB), as a good mediator, was initially electrodeposited on a gold electrode surface, then double‐layer nanogold particles and double‐strand DNA (dsDNA) with the sandwich‐type architecture were constructed on the PB‐modified surface in turn, and then anti‐CA 15‐3 antibodies were adsorbed onto the surface of nanogold particles. The double‐layer nanogold particles provided a good microenvironment for the immobilization of biomolecules. The presence of dsDNA enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The performance and factors influencing the performance of the immunosensor were evaluated. Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 1.0 to 240 ng/mL with a relatively low detection limit of 0.6 ng/mL (S/N=3) towards CA 15‐3. The stability, reproducibility and precision of the as‐prepared immunosensor were acceptable. 57 serum specimens were assayed by the developed immunosensor and standard enzyme‐linked immunosorbent assay (ELISA), respectively, and the results obtained were almost consistent. More importantly, the proposed methodology could be further developed for the immobilization of other proteins and biocompounds.  相似文献   

18.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

19.
A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL(-1) with a slope value of 7.0 nA mL ng(-1). The limit of detection was 3.74 ng mL(-1). Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.  相似文献   

20.
In this study, a novel and enzyme-free electrochemical immunoassay was developed for the detection of alpha-fetoprotein (AFP; as a model biomarker) by using a novel redox nanocatalyst, patterned gold-iridium oxide nanoparticle assemblies (Au-IrOx), on a Prussian blue (PB) functionalized glassy carbon electrode. The as-prepared Au-IrOx nanospheres were not only used for the labeling of secondary anti-AFP antibody but also executed for water oxidation. With a sandwich immunoassay format, the electrochemical measurement was carried out in 0.1 M KNO3-HCl, pH 3.2, containing 1.0 mM p-aminophenol (AP). Initially, the added AP was oxidized to p-quinone imine (QI) with the help of the immobilized PB on the electrode, and then the generated QI was reduced back to AP by hydrogenation reaction from water oxidation. The self-produced QI reactants were catalytically recycled and thus amplified the signal of electrochemical response. Under optimal conditions, the electrochemical immunosensor displayed a wide working range of 0.005 to 200 ng/mL with a low detection limit of 0.5 pg/mL AFP (at 3sB). Intra- and inter-assay coefficients of variation were below 10%. In addition, the methodology was validated with real serum samples, receiving a good agreement with the results obtained from commercially available electrochemiluminescence automated analyzer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号