首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We introduce herein an efficient microfluidic approach for continuous transport and localized collection of nanoparticles via hybrid electrokinetics, which delicately combines linear and nonlinear electrokinetics driven by a composite DC-biased AC voltage signal. The proposed technique utilizes a simple geometrical structure, in which one or a series of metal strips serving as floating electrode (FE) are attached to the substrate surface and arranged in parallel between a pair of coplanar driving electrodes (DE) in a straight microchannel. On application of a DC-biased AC electric field across the channel, nanoparticles can be transported continuously by DC bulk electroosmotic flow, and then trapped selectively onto the metal strips due to AC-field induced-charge electrokinetic (ICEK) phenomenon, which behaves as counter-rotating micro-vortices around the ideally polarizable surfaces of FE. Finite-element simulation is carried out by coupling the dual-frequency electric field, flow field and sample mass transfer in sequence, for guiding a practical design of the microfluidic nanoparticle concentrator. With the optimal device geometry, the actual performance of the technique is investigated with respect to DC bias, AC voltage amplitude, and field frequency by using both latex nanospheres (∼500 nm) and BSA molecules (∼10 nm). Our experimental observation indicates nanoparticles are always enriched into a narrow bright band on the surface of each FE, and a horizontal concentration gradient even emerges in the presence of multiple metal strips, which therefore permits localized analyte enrichment. The proposed trapping method is supposed to guide an elaborate design of flexible electrokinetic frameworks embedding FE for continuous-flow analyte manipulation in modern microfluidic systems.  相似文献   

2.
Induced‐charge electroosmosis (ICEO) has attracted tremendous popularity for driving fluid motion from the microfluidic community since the last decade, while less attention has been paid to ICEO‐based nanoparticle manipulation. We propose herein a unique concept of hybrid electroosmotic kinetics (HEK) in terms of bi‐phase ICEO (BICEO) actuated in a four‐terminal spiral electrode array, for effective electrokinetic enrichment of fluorescent polystyrene nanoparticles on ideally polarizable metal strips. First, by alternating the applied AC voltage waves between consecutive discrete terminals, the flow stagnation lines where the sample nanoparticles aggregate can be switched in time between two different distribution modes. Second, we innovatively introduce the idea of AC field‐effect flow control on BICEO; by altering the combination of gating voltage sequence, not only the number of circulative particle trapping lines is doubled, but the collecting locations can be flexibly reconfigured as well. Third, hydrodynamic streaming of DC‐biased BICEO is tested in our device design, wherein the global linear electroosmosis dominates BICEO contributed from both AC and DC components, resulting in a reduction of particle enrichment area, while with a sharp increase in sample transport speed inside the bulk phase. The flow field associated with HEK is predicted using a linear asymptotic analysis under Debye–Huckel limit, with the simulation results in qualitative agreement with in‐lab observations of nanoparticle trapping by exploiting a series of improved ICEO techniques. This work provides an affordable and field‐deployable platform for real‐time nanoparticle trapping in the context of dilute electrolyte.  相似文献   

3.
J S Buch  P C Wang  D L DeVoe  C S Lee 《Electrophoresis》2001,22(18):3902-3907
The application of the field-effect for direct control of electroosmosis in a polydimethylsiloxane (PDMS)-based microfluidic system, constructed on a silicon wafer with a 2.0 microm electrically insulating layer of silicon dioxide, is demonstrated. This microfluidic system consists of a 2.0 cm open microchannel fabricated on a PDMS slab, which can reversibly adhere to the silicon wafer to form a hybrid microfluidic device. Aside from mechanically serving as a robust bottom substrate to seal the channel and support the microfluidic system, the silicon wafer is exploited to achieve field-effect flow control by grounding the semiconductive silicon medium. When an electric field is applied through the channel, a radial electric potential gradient is created across the silicon dioxide layer that allows for direct control of the zeta potential and the resulting electroosmotic flow (EOF). By configuring this microfluidic system with two power supplies at both ends of the microchannel, the applied electric potentials can be varied for manipulating the polarity and the magnitude of the radial electric potential gradient across the silicon dioxide layer. At the same time, the longitudinal potential gradient through the microchannel, which is used to induce EOF, is held constant. The results of EOF control in this hybrid microfluidic system are presented for phosphate buffer at pH 3 and pH 5. It is also demonstrated that EOF control can be performed at higher solution pH of 6 and 7.4 by modifying the silicon wafer surface with cetyltrimethylammonium bromide (CTAB) prior to assembly of the hybrid microfluidic system. Results of EOF control from this study are compared with those reported in the literature involving the use of other microfluidic devices under comparable solution conditions.  相似文献   

4.
Colloidal particles and biological cells are patterned and separated laterally adjacent to a micropatterned electrode array by applying AC electric fields that are principally oriented normally to the electrode array. This is demonstrated for yeast cells, red blood cells, and colloidal polystyrene particles of different sizes and zeta-potentials. The separation mechanism is observed experimentally to depend on the applied field frequency and voltage. At high frequencies, particles position themselves in a manner that is consistent with dielectrophoresis, while at low frequencies, the positioning is explained in terms of a strong coupling between gravity, the vertical component of the dielectrophoretic force, and the Stokes drag on particles induced by AC electroosmotic flow. Compared to high frequency dielectrophoretic separations, the low frequency separations are faster and require lower applied voltages. Furthermore, the AC electroosmosis coupling with dielectrophoresis may enable cell separations that are not feasible based on dielectrophoresis alone.  相似文献   

5.
Horiuchi K  Dutta P 《Lab on a chip》2006,6(6):714-723
A field-effect transistor is developed to control flow in microfluidic chips by modifying the surface charge condition. In this investigation, zeta potential at a particular location is altered locally by applying a gate voltage, while zeta potential at other locations is maintained at its original value. This non-uniform zeta potential results in a secondary electroosmotic flow in the lateral direction, which is used for flow control in microgeometries. Here, microchannel structures and field-effect transistors are formed on polydimethylsiloxane (PDMS) using soft lithography techniques, and a micro particle image velocimetry technique is used to obtain high resolution velocity distribution in the controlled region. The flow control is observed at relatively low gate voltage (less than 50 V), and this local flow control is primarily due to current leakage through the interface between PDMS and glass layers. A leakage capacitance model is introduced to estimate the modified zeta potential for the straight channel case, and excellent agreement is obtained between the predicted and experimental zeta potential results. This leakage-current based field-effect is then applied to a T-channel junction to control flow in the branch channel. Experiments show that the amount of discharge in the branch channel can be controlled by modulating gate voltage.  相似文献   

6.
Johann R  Renaud P 《Electrophoresis》2004,25(21-22):3720-3729
Selective transport and sorting of particles in microfluidic devices by electroosmosis is complicated due to superposition of uncontrolled hydrodynamic pressure contributions on the electroosmotic force. In this paper, we present a microfluidic concept for the reliable and simple separation and sorting of particles in a microchip by electroosmosis combined with pressure-driven flow. The presented device allows fluid quantities to be switched and particles to be sorted within a channel manifold using only a single power supply with fixed voltage and an electric switch. Consequently, chip operation and fluid switching procedure are greatly simplified compared to a situation, in which several independent power sources are used for flow balancing, as is the common procedure. With the triple-T channel design presented, backpressure flow disturbing the electrokinetic fluid and particle separation process is eliminated by introducing controlled opposed hydrodynamic flow of buffer from side channels. This pressure-driven flow is generated on-chip by setting up differences in the reservoir pressures in a defined manner. A detailed flow analysis based on the equivalence of fluid flow and electric current is performed and the conditions for reliable chip function are worked out.  相似文献   

7.
Islam N  Reyna J 《Electrophoresis》2012,33(7):1191-1197
This paper discusses the principle of biased alternating current electroosmosis (ACEO) and its application to move the bulk fluid in a microchannel, as an alternative to mechanical pumping methods. Previous EO-driven flow research has looked at the effect of electrode asymmetry and transverse traveling wave forms on the performance of electroosmotic pumps. This paper presents an analysis that was conducted to assess the effect of combining an AC signal with a DC (direct current) bias when generating the electric field needed to impart electroosmosis (EO) within a microchannel. The results presented here are numerical and experimental. The numerical results were generated through simulations performed using COMSOL 3.5a. Currently available theoretical models for EO flows were embedded in the software and solved numerically to evaluate the effects of channel geometry, frequency of excitation, electrode array geometry, and AC signal with a DC bias on the flow imparted on an electrically conducting fluid. Simulations of the ACEO flow driven by a constant magnitude of AC voltage over symmetric electrodes did not indicate relevant net flows. However, superimposing a DC signal over the AC signal on the same symmetric electrode array leads to a noticeable net forward flow. Moreover, changing the polarity of electrical signal creates a bi-directional flow on symmetrical electrode array. Experimental flow measurements were performed on several electrode array configurations. The mismatch between the numerical and experimental results revealed the limitations of the currently available models for the biased EO. However, they confirm that using a symmetric electrode array excited by an AC signal with a DC bias leads to a significant improvement in flow rates in comparison to the flow rates obtained in an asymmetric electrode array configuration excited just with an AC signal.  相似文献   

8.
Nanopores have become a popular single-molecule manipulation and detection technology. In this paper, we have constructed a continuum model of the nanopore; the arbitrary Lagrangian-Eulerian (ALE) method is used to describe the motion of particles and fluid. The mathematical model couples the stress-strain equation for the dynamics of a deformable particle, the Poisson equation for the electric field, the Navier-Stokes equations for the flow field, and the Nernst-Planck equations for ionic transport. Based on the model, the mechanism of field-effect regulation of particles passing through a nanopore is investigated. The results show that the transport of particles which is controlled by the field effect depends on the electroosmotic flow (EOF) generated by the gate electrode in the nanopore and the electrostatic interaction between the nanopore and particles. That also explains the asymmetry of particle transport velocity in the nanopore with a gate electrode. When the gate potential is negative, or the gate electrode length is small, the maximum deformation of the particles is increased. The field-effect regulation in the nanopore provides an active and compatible method for nanopore detection, and provides a convenient method for the active control of the particle deformation in the nanopore.  相似文献   

9.
General solutions are developed for direct current (DC) and alternating current (AC) electroosmotic flows in microfluidic channels with arbitrary cross-sectional geometry and arbitrary distribution of wall charge (zeta potential). The applied AC electric field can also be of arbitrary waveform. By proposing a nondimensional time scale varpi defined as the ratio of the diffusion time of momentum across the electric double-layer thickness to the period of the applied electric field, we demonstrate analytically that the Helmholtz-Smoluchowski electroosmotic velocity is an appropriate slip condition for AC electroosmotic flows in typical microfluidic applications. With this slip condition approach, electroosmotic flows in rectangular and asymmetric trapezoidal microchannels with nonuniform wall charge, as examples, are investigated. The unknown constants in the proposed general solutions are numerically determined with a least-squares method through matching the boundary conditions. We find that the wall charge affects significantly the electroosmotic flow while the channel geometry does not. Moreover, the flow feature is characterized by another nondimensional time scale Omega defined as the ratio of the diffusion time of momentum across the channel hydraulic radius to the period of the applied electric field. The onset of phase shift between AC electroosmotic velocity and applied electric field is also examined analytically.  相似文献   

10.
高效毛细管电泳(HPCE)是近年来发展起来的一种新型高效分离技术。它具有分离速度快、效率高、重复性好等特点,受到国内外学术界的关注。电渗是影响HPCE分离效率的重要因素,如何抑制电渗对分离效率的影响是人们研究的重要内容。本文对石英毛细管在高压电场中的电渗性能进行了多因素的研究。结果表明,综合优化实验条件可以改变电  相似文献   

11.
This paper investigates two-dimensional, time-dependent electroosmotic flow driven by an AC electric field via patchwise surface heterogeneities distributed along the micro-channel walls. The time-dependent flow fields through the micro-channel are simulated for various patchwise heterogeneous surface patterns using the backwards-Euler time stepping numerical method. Different heterogeneous surface patterns are found to create significantly different electrokinetic transport phenomena. The transient behavior characteristics of the generated electroosmotic flow are then discussed in terms of the influence of the patchwise surface heterogeneities, the direction of the applied AC electric field, and the velocity of the bulk flow. It is shown that the presence of oppositely charged surface heterogeneities on the micro-channel walls results in the formation of localized flow circulations within the bulk flow. These circulation regions grow and decay periodically in phase with the applied periodic AC electric field intensity. The location and rotational direction of the induced circulations are determined by the directions of the bulk flow velocity and the applied electric field.  相似文献   

12.
Flow rates of up to 50 microm s(-1) have been successfully achieved in a closed-loop channel using an AC electroosmotic pump. The AC electroosmotic pump is made of an interdigitated array of unequal width electrodes located at the bottom of a channel, with an AC voltage applied between the small and the large electrodes. The flow rate was found to increase linearly with the applied voltage and to decrease linearly with the applied frequency. The pump is expected to be suitable for circular chromatography for the following reasons: the driving forces are distributed over the channel length and the pumping direction is set by the direction of the interdigitated electrodes. Pumping in a closed-loop channel can be achieved by arranging the electrode pattern in a circle. In addition the inherent working principle of AC electroosmotic pumping enables the independent optimisation of the channel height or the flow velocity.  相似文献   

13.
Electroosmosis is the phenomenon of fluid flow induced by an applied electric field. This paper is concerned with electroosmosis in a porous material composed of closely-packed spheres immersed in a general electrolyte. A formula is obtained for the electroosmotic flow rate in the case when the double layer is much thinner than the particle radius. By combining this formula with electroosmosis measurements it is possible to determine the particle ζ potential. To test the validity of the model which underlies this, and most other electrokinetic calculations, ζ potentials obtained from Van der Put and Bijsterbosch's (J. Colloid Interface Sci. 92, 499, 1983) electroosmosis measurements are compared with potentials obtained from their conductivity and electrophoresis measurements.  相似文献   

14.
A novel two-dimensional electrophoretic system for the control of electroosmosis in capillary zone electrophoresis has been developed and evaluated for rapid separations of proteins. The system comprises uncoated and polyether-coated fused silica capillaries coupled in series. An equation relating the average electroosmotic flow velocity in the coupled capillaries to the intrinsic electroosmotic velocities of the connected segments and their corresponding lengths has been derived and verified experimentally. This approach has the advantage of enabling the electroosmotic flow to be tuned independently of the applied voltage. As a consequence, rapid protein analysis at relatively low field strength was achieved without sacrificing the high separation efficiencies obtained with surface-modified capillaries.  相似文献   

15.
A novel concept for electroosmotic flow (EOF) control in a microfluidic chip is presented by using a self-assembled monolayer as the insulator of a flow field-effect transistor. Bidirectional EOF control with mobility values of 3.4 × 10(-4) and -3.1 × 10(-4) cm(2)/V s can be attained, corresponding to the applied gate voltage at -0.8 and 0.8 V, respectively, without the addition of buffer additives. A relatively high control factor (approximately 400 × 10(-6) cm(2)/V(2) s) can be obtained. The method presented in this study offers a simple strategy to control the EOF.  相似文献   

16.
The performance of conventional surface plasmon resonance (SPR) biosensors can be limited by the diffusion of the target analyte to the sensor surface. This work presents an SPR biosensor that incorporates an active mass‐transport mechanism based on dielectrophoresis and electroosmotic flow to enhance analyte transport to the sensor surface and reduce the time required for detection. Both these phenomena rely on the generation of AC electric fields that can be tailored by shaping the electrodes that also serve as the SPR sensing areas. Numerical simulations of electric field distribution and microparticle trajectories were performed to choose an optimal electrode design. The proposed design improves on previous work combining SPR with DEP by using face‐to‐face electrodes, rather than a planar interdigitated design. Two different top‐bottom electrode designs were experimentally tested to concentrate firstly latex beads and secondly biological cells onto the SPR sensing area. SPR measurements were then performed by varying the target concentrations. The electrohydrodynamic flow enabled efficient concentration of small objects (3 μm beads, yeasts) onto the SPR sensing area, which resulted in an order of magnitude increased SPR response. Negative dielectrophoresis was also used to concentrate HEK293 cells onto the metal electrodes surrounded by insulating areas, where the SPR response was improved by one order of magnitude.  相似文献   

17.
We study herein numerically the use of induced-charge electrokinetic phenomena to enable a flexible control of ion transport of dilute electrolyte in a straight ion concentration polarization system. The effect of three convection modes of induced-charge electrokinetic phenomena, including induced-charge electroosmosis, flow-field effect transistor, and alternating-current electroosmosis (ACEO), on convective arrestment of diffusive wave-front propagation is investigated by developing a cross-scale and fully coupled transient numerical simulation model, wherein multiple frequency electrochemical polarization and nonlinear diffuse charge dynamics in spatiotemporally varying solution conductivity are taken into account. We demonstrate by detailed comparative simulation studies that ACEO vortex flow field above a metal strip array arranged along the anodic chamber's bottom surface serves as the most efficient way for adjusting the salt density distribution at micrometer and even millimeter dimension, due to its high flexibility in controlling the stirring flow state with the introduction of two extra electrical parameters. The specific operating status is determined by whether the electrode array is floating in potential (induced-charge electroosmosis) or biased to ground (flow-field effect transistor) or forced to oscillate at another Fourier mode (ACEO). These results prove useful for on-chip electric current control with electroconvective stirring.  相似文献   

18.
This study presents on-chip continuous accumulation and concentration of nanoscale samples using a cascade alternating current electroosmosis (cACEO) flow. ACEO can generate flow motion caused by ion movement due to interactions between the AC electric field and the induced charge layer on the electrode surface, with the potential to accumulate particles, especially in low-conductive liquid. However, the intrinsic particle diffusive motion, which is sensitive to particle size, is an essential element influencing accumulation efficiency. In this study, an electrode combining chevron and double-gap geometry embedded in a microfluidic channel was developed to perform efficient three-dimensional (3D) nanoparticle focusing using ACEO. The chevron electrode pattern was introduced upstream of the focusing zone to overcome particle accumulation in scattering zones near the channel sidewall. To demonstrate the efficiency of the proposed device for particle accumulation, three nanoparticle types were used: latex, metal, and biomaterial. Continuous 3D concentration of 50-nm polystyrene particles was confirmed. The concentration factor, determined based on image processing, became quite high when 50-nm gold nanoparticles were used. Moreover, nanoparticles with a 20-nm diameter were accumulated using cACEO. Finally, we used the concentrator chip to accumulate 50-nm liposome particles, confirming that the device could also successfully concentrate biomaterials.  相似文献   

19.
Introducing an electric field into chromatography on hydroxyapatite (HAP) was attempted in order to enhance mass transfer and separation performance. A membrane spaced multicompartment electrolyzer was developed for electrochromatography on HAP. The high performance of liquid transport by electroosmotic flux was identified and described in terms of dynamic electroosmotic pressure. The application of the electric field resulted in an improved adsorption of bovine serum albumin as shown by the breakthrough curve as function of the electric field. An improved elution was also obtained in the presence of the electric field. The results show that electroosmosis is a powerful tool of liquid transport and dispersion in a packed bed of fine particles and has potential in the large-scale chromatography of biological molecules.  相似文献   

20.
We consider the effects that step changes in zeta potential and cross section have on electroosmosis in long-and-narrow channels with arbitrary cross-sectional shapes. The Stokes equation of flow is solved analytically utilizing the thin Debye layer approximation to provide effective slip velocities on the channel walls. The effects of channel dimensions, surface potentials, applied pressure drop, and applied voltage are discussed. One anecdotal case, a two-region rectangular channel, is presented to illustrate the solution. The flow in each region is a combination of a uniform electroosmotic flow and a nonuniform pressure-driven flow. The electroosmotic pumping causes the pressure gradient in each region to adjust so that the flow rate is the same in each region and the overall applied pressure drop is met, resulting in convex velocity profiles in some regions and concave velocity profiles in other regions. By appropriate choice of the applied pressure drop, flat velocity profiles may be achieved in one or more regions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号