首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The retention of liquids in the corners of a 0.03-cm square capillary after the passage of a gas slug was studied experimentally as a function of capillary number in the range from 10(-3) to 10(-6). In gas-wetting liquid systems, for capillary number greater than 5 x 10(-4), the retention of a wetting liquid in the corners showed a strong dependence on the capillary number; i.e., the retention of the liquid decreased with decreasing capillary number. For capillary number less than 10(-4), the retention of a wetting liquid was found to be determined by the capillary forces and the rate (or viscous) effect was negligible. In gas-oil-water systems involving double displacements--gas was displacing oil which was in turn displacing water--the total retention of water and oil vs capillary number curve showed the same trend as the retention of a wetting phase in a gas-wetting liquid system. However, because of the viscous effect, the water retention showed a continuous decrease with decreasing capillary number and could be lower than the capillary equilibrium value at very low capillary numbers. As a result of this, the oil retention vs capillary number curve in the double displacement process showed a minimum; i.e., oil retention increased with decreasing capillary number in the range of very low capillary numbers.  相似文献   

2.
Dong X  Wu R  Dong J  Wu M  Zhu Y  Zou H 《Electrophoresis》2008,29(18):3933-3940
An approach of immobilizing mobile crystalline material (MCM)-41 mesoporous silica nanoparticles on the inner wall of an open-tubular (OT) capillary as the support for coating chiral selector of cellulose tris(3,5-dimethylphenyl-carbamate) (CDMPC) was carried out. By taking advantage of the improved phase ratio of OT capillary with the immobilization of MCM-41 mesoporous material, the cellulose derivative of CDMPC as the chiral selector was simply coated on the MCM-41 nanoparticle layer via the hydrogen-bonding interaction, and the enantioseparation was successively carried out. Eight pairs of acidic, neutral and basic enantiomers were resolved in capillary electrochromatography or capillary liquid chromatography mode. The concentration of CDMPC for coating was systematically investigated to obtain the optimized chromatographic properties on enantioseparation by controlling the supposed film thickness of CDMPC on MCM-41 nanoparticle layer. Comparing with a bare fused silica capillary column coated with CDMPC under the same coating procedure as MCM-41-modified capillary did, the MCM-41-modified capillary column offered much higher enantioselectivity. This result indicated the significance of using the mesoporous nanoparticles as the electrochromatographic support to enhance the phase ratio of OT capillary column in capillary electrochromatography and capillary liquid chromatography. For investigating the effect of experimental conditions on the enantioseparation with this prepared OT capillary column, the content of organic modifier acetonitrile in the mobile phase was thus extensively evaluated to achieve a better chiral separation.  相似文献   

3.
Recent advances in capillary electrophoresis/electrospray-mass spectrometry   总被引:6,自引:0,他引:6  
In this review, the progress in hyphenation of capillary electrophoresis (CE) with electrospray ionization-mass spectrometry (ESI-MS) since the article of Banks (Banks, J. F., Electrophoresis 1997, 18, 2255-2266) is reported. In all capillary-based electromigration techniques, such as capillary gel electrophoresis (CGE), capillary isotachophoresis (CITP), capillary isoelectric focussing (CIEF), micellar electrokinetic chromatography (MEKC), affinity capillary electrophoresis (ACE), as well as in the hybrid techniques capillary electrochromatography (CEC), and pressurized capillary electrochromatography (pCEC) progress has been made in experimental setups, and for many groups of analytes, such as peptides, proteins, nucleotides, saccharides, drugs and their metabolites, CE/ESI-MS has been successfully applied. Electromigration is further miniaturized. New preconcentration methods allow the investigation of compounds, which are not sensitively detected with ESI-MS. Coordination ion spray (CIS) MS is another method for sensitivity enhancement by on-line formation of charged coordination compounds.  相似文献   

4.
This article gives an overview of the applications of capillary electrophoretic methods to investigate the non‐covalent interactions of peptides (peptide complexes) with variable middle‐ and high‐molecular‐mass receptors (ligands) as well as with small ions and molecules in the period 2007–2014. Different modes of capillary electrophoretic methods, such as mobility shift (vacancy) affinity capillary electrophoresis, multiple injection affinity capillary electrophoresis, partial filling affinity capillary electrophoresis, Hummel–Dryer method, vacancy peak method and (continuous) frontal analysis capillary electrophoresis, are briefly described and their applicability to determination of binding constants of peptide complexes is discussed. In addition, the detailed experimental conditions of individual applications and the values of binding constants of the particular peptide complexes are presented.  相似文献   

5.
In this work, a new generation UV-transparent polymer, fluorinated ethylenepropylene copolymer (FEP) exhibiting a low degree of crystallinity, extruded in dimensions similar to the most commonly used CE capillaries of approximately 80 mum id and about 360 mum od was investigated for its use as a CE capillary. FEP is transparent down to the low-UV region, and as fluorinated polymers in general are good electrical insulators and exhibit reasonable heat conductivity, it has considerable potential as a material for electrodriven analysis in capillary or microchip formats. The FEP capillary has been characterised with regard to some important aspects for its use as a CE capillary, including its profile of EOF versus pH, as well as procedures for manipulating EOF by coating the inner capillary wall with various semipermanent and dynamic layers. The FEP capillaries were tested and compared with fused-silica capillary for the separation of inorganic and small organic ions using conditions involving direct and indirect detection in the low-UV region. Finally, advantages of the use of the FEP capillary for simultaneous detection of a mixture containing nine inorganic cations and anions using indirect photometric detection with a movable light-emitting diode (LED) detector and a novel electrolyte are demonstrated.  相似文献   

6.
Electrophoretic separations are of growing interest to tackle complex analytical challenges. Nevertheless, capillary electrophoresis, as the most common mode, still suffers from insufficient detection limits due to low capillary loadability. ITP is of growing interest as preconcentration method for capillary electrophoresis and is also interesting to be applied as an independent analytical method. While mass spectrometric detection is common for capillary electrophoresis, the combination of ITP with MS is still a niche technique. In this work, we want to give an overview on isotachophoretic effects in CE-MS and ITP-MS methods, as well as coupling techniques of ITP with CE-MS. The challenges and possibilities associated with mass spectrometric detection in ITP and its coupling to capillary electrophoresis are critically discussed.  相似文献   

7.
A new application of the polymeric ionic liquid (PIL) in capillary electrophoresis is reported. Poly(1-vinyl-3-butylimidazolium bromide) was physically adsorbed on silica capillary as the simple and effective coating for capillary electrophoresis (CE) analysis, in which the PIL is not present in the background electrolyte. The electroosmotic flow (EOF) of the PIL-coated capillary as compared with that of the bare fused-silica capillary shows a different dependence on electrolyte pH values. The EOF is reversed over a wide pH range from 3.0 to 9.0 and shows good repeatability. It is also found that the coated capillary has a good tolerance to some organic solvents, 0.1 M NaOH and 0.1 M HCl. The PIL-coated capillary has been employed in different areas. Both the basic proteins and anionic analytes can be well separated by PIL-coated capillaries in a fast and easy way. The PIL-coated capillary is also able to separate organic acid additives in a grape juice. The results showed that this type of coating provides an alternative to the CE separation of anions and basic proteins.  相似文献   

8.
本研究制备了一种应用于液-质联用(LC-MS)系统中的带喷头混合型毛细管色谱柱.用标准蛋白和酵母蛋白胰蛋白酶酶切溶液考察了其在LC—MS中的离子化效率、毛细管色谱柱分离性能和寿命,并与直接填充型毛细管色谱柱的色谱性能进行比较,未见显著性差异.将制备的带喷头混合型毛细管色谱柱应用于鼠肝蛋白组的分析,在假阳性率为1%的条件下鉴定到1262个肽段,归属于513个蛋白簇.通过对鉴定蛋白质理化性能的统计分析,其等电点和分子量分布高于一般两维凝胶电泳的范围.实验结果还表明该混合型毛细管色谱柱在肽段的理化性能上没有偏性,可以广泛应用于蛋白质组学的研究中.  相似文献   

9.
A 50 microm capillary that has been etched with ammonium hydrogen difluoride is evaluated as a separation medium for capillary electrochromatography. For a tryptic digest of transferrin, the etched capillary gave better resolution (more peaks in the overall peptide map) and longer retention than separations done under identical experimental conditions on an unetched fused-silica capillary. Resolution on the etched capillary was improved by lowering the voltage from 300 to 267 V/cm. A four-component protein sample also resulted in longer retention on an echted capillary than on an unetched fused-silica capillary that were both coated with Polybrene. After correction for differences in electroosmotic flow between the two capillaries, the calculated electrophoretic mobilities for all four proteins were lower on the etched capillary than on the unetched fused-silica capillary. The results of both the tryptic digest and protein experiments strongly indicate the presence of chromatographic effects on the etched capillary that contribute to the increased retention and improved resolution with respect to the unetched fused-silica capillary.  相似文献   

10.
A fluorosurfactant has been studied using capillary electrophoresis and mass spectrometry. The fluorosurfactant, FC134, can be used as a buffer additive in capillary electrophoresis in order to decrease wall adsorption of proteins and in micellar electrokinetic chromatography. However, it has been discovered that this fluorosurfactant is polydisperse, thus containing substances with different lengths and structures. In this work, the fluorosurfactant sample components were separated by capillary electrophoresis. An uncoated as well as a poly(vinyl alcohol)-coated capillary were used with running electrolytes containing methanol and acetic acid. Following the capillary electrophoretic separation, fractions were collected for further analysis by MALDI-MS. Non-fractionated samples were also analyzed both by MALDI-MS and by ESI-MS.  相似文献   

11.
Problems encountered in capillary electrochromatography, i.e. non-reproducible column manufacture, bubble formation during usage, short column lifetimes and limited choice of packing particles are addressed by the development of fritless or single-frit, internally tapered, segmented and dead-volume free coupled capillary columns. The Van Deemter plots measured demonstrate the performance of these high-quality capillaries which are suitable for capillary electrochromatography as well as for capillary high-performance liquid chromatographic applications.  相似文献   

12.
A decade of capillary electrophoresis   总被引:2,自引:0,他引:2  
Issaq HJ 《Electrophoresis》2000,21(10):1921-1939
Since the introduction of the first commercial capillary electrophoresis (CE) instrument a decade ago, CE applications have become widespread. Today, CE is a versatile analytical technique which is successfully used for the separation of small ions, neutral molecules, and large biomolecules and for the study of physicochemical parameters. It is being utilized in widely different fields, such as analytical chemistry, forensic chemistry, clinical chemistry, organic chemistry, natural products, pharmaceutical industry, chiral separations, molecular biology, and others. It is not only used as a separation technique but to answer physicochemical questions. In this review, we will discuss different modes of CE such as capillary zone electrophoresis, micellar electrokinetic chromatography, capillary gel electrophoresis, capillary isoelectric focusing, and capillary electrochromatography, and will comment on the future direction of CE, including array capillary electrophoresis and array microchip separations.  相似文献   

13.
Monolithic capillary columns containing native silica gel were covalently modified with 3,5-disubstituted phenylcarbamate derivatives of cellulose and amylose and applied for enantioseparations in capillary LC. The method previously used for covalent immobilization of polysaccharide phenylcarbamate derivatives onto the surface of microparticulate silica gel was successfully adapted for in situ modification of monolithic fused-silica capillary columns. The effects of the nature of polysaccharide and the substituents, as well as of multiple covalent immobilization of polysaccharide derivative on chromatographic performance of capillary columns were studied. The capillary columns obtained using this technique are stable in all solvents commonly used in LC and exhibit promising enantiomer resolving ability.  相似文献   

14.
Wu XZ  Pawliszyn J 《Electrophoresis》2002,23(4):542-549
Whole-column imaging capillary electrophoresis with a short capillary is discussed. A short capillary (3-6 cm) coated with either fluorocarbon or polyacrylamide was used as a separation capillary. The whole capillary was illuminated with 280 nm light, and the transmitted light was monitored by a linear charge-coupled device (CCD). For the short capillary, hydrodynamic flow caused by a subtle height difference between the anodic and cathodic reservoirs affected the sample migration in the capillary greatly. Several sample injection methods, including use of a cross connection, sealing of the capillary ends with a gel, and use of a gel-filled capillary, have been discussed. The experimental results showed that the peak height decreased and peak width increased with the electromigration distance. Therefore, higher sensitivity was obtained in a short capillary rather than a long capillary. The whole-column imaging CE with the short capillary has been applied for the study of conjugation reactions of protein cytochrome c with sodium dodecyl sulfate (SDS) and the dye Congo Red. The method has also been used for in situ monitoring of the electrophoretic protein desorption process. Our technique is a unique tool for the study of protein binding reactions and the interaction between analyte and inner wall of the capillary.  相似文献   

15.
An investigation was conducted of various glasses, other than soda lime or borosilicate, for use in glass capillary gas chromatography. The work has uncovered some unique chromatographic qualities in the use of potash soda lead and fused silica glasses as materials for making glass capillary columns. The fused silica proved to be an ideal material for capillary column construction, being inherently more inert than glass containing metal oxides. It has been shown that through the use of thin wall capillary tubing of high flexibility many of the mechanical problems associated with glass capillary columns, such as fragility and column straightening, can be avoided.  相似文献   

16.
Motivated by experimental results, we present numerical and analytical calculations of the capillary force exerted by a capillary bridge spanning the gap between two parallel flat plates of asymmetric wettability. Depending on whether the sum of the two contact angles is smaller or larger than 180 degrees, the capillary force is either attractive or repulsive at small separations D between the plates. In either cases the magnitude of the force diverges as D approaches zero. The leading order of this divergence is captured by an analytical expression deduced from the geometry of the meniscus of a flat capillary bridge. The results for substrates with different wettability reveal an interesting behavior: with the sum of the contact angles fixed, the magnitude of the capillary force and the rupture separation decreases as the asymmetry in contact angles is increased. In addition, we present the rupture separation, i.e., the maximal extension of a capillary bridge, as a function of the contact angles. Our results provide an extensive picture of surface wettability effects on capillary adhesion.  相似文献   

17.
Capillary impregnation into cylinder banks   总被引:3,自引:0,他引:3  
The capillary rise of liquid in a cylinder bank is examined in order to study the capillary pressure variation perpendicular to the direction of the cylinders. The calculations consider the local geometric variation of the flow channel and the position-dependent capillary pressure. The capillary flow around each cylinder is calculated by balancing the capillary pressure and the viscous drag along the flow path. The rate of filling for several layers of cylinders is used to estimate the equivalent capillary pressure. The method is also applied to the underfill of a flip chip system, which is modeled as a cylinder bank between parallel plates.  相似文献   

18.
Isotherms of capillary condensation are often used to determine the vapor sorption capacity of porous adsorbents as well as the pore size distribution by radii. In this paper, for calculating the volume of capillary condensate and of adsorption films in a porous body, an approach based on the theory of surface forces is used. Adsorption isotherms and disjoining pressure isotherms of wetting films are presented here in an exponential form discussed earlier. The calculations were made for straight cylindrical capillaries of different radii and slit pores of different width. The mechanisms of capillary condensation differ in cylindrical and slit pores. In cylindrical pores capillary condensation occurs due to capillary instability of curved wetting films on a capillary surface, when film thickness grows. In the case of slit pores, coalescence of wetting films formed on opposite slit surfaces proceeds under the action of attractive dispersion forces. Partial volumes of liquid in the state of both capillary condensate and adsorbed films are calculated dependent on the relative vapor pressure in a surrounding media. Copyright 2000 Academic Press.  相似文献   

19.
The forced water-oil displacement in capillary is a model that has important applications such as the groundwater remediation and the oil recovery. Whereas it is difficult for experimental studies to observe the displacement process in a capillary at nanoscale, the computational simulation is a unique approach in this regard. In the present work, the many-body dissipative particle dynamics (MDPD) method is employed to simulate the process of water-oil displacement in capillary with external force applied by a piston. As the property of all interfaces involved in this system can be manipulated independently, the dynamic displacement process is studied systematically under various conditions of distinct wettability of water in capillary and miscibility between water and oil as well as of different external forces. By analyzing the dependence of the starting force on the properties of water/capillary and water/oil interfaces, we find that there exist two different modes of the water-oil displacement. In the case of stronger water-oil interaction, the water particles cannot displace those oil particles sticking to the capillary wall, leaving a low oil recovery efficiency. To minimize the residual oil content in capillary, enhancing the wettability of water and reducing the external force will be beneficial. This simulation study provides microscopic insights into the water-oil displacement process in capillary and guiding information for relevant applications.  相似文献   

20.
The present study reports the investigation of capillary electrophoresis (CE) for the separation of the photosynthetic pigments (chlorophyll derivatives as well as carotenoids) together. Various CE methods, such as micellar electrokinetic chromatography, capillary electrokinetic chromatography, and nonaqueous capillary electrophoresis (NACE) are tested, with coated and uncoated capillary columns to evaluate optimal separation conditions using diode array detection. The effect of different type and composition of organic solvents and surfactants on the separation is discussed. Detection limits are found in the range of 1.14-2.45 ppm. According to the system suitability results, the most effective separation is observed using NACE with Aliquat 336 as cationic surfactant in coated capillary and mixture of MeOH-ACN-THF (5:4:1, v/v/v) as solvent. Quantitative evolution is investigated, and recovery percentage values are found to be 96.7-102%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号