首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new experimental setup allows the measurement of hydrodynamic interactions between the walls of a vessel and a particle moving along a three-dimensional trajectory in a viscous fluid. The vertical motion of the particle is measured with an accuracy of 50 nm using laser interferometry, while its horizontal movements are controlled with an accuracy of 20 μm by displacing the vessel in the horizontal direction so as to keep the sphere in the fixed vertical laser beam. Three axisymmetric closed containers are used as examples: two vertical cylinders (with flat and convex lens-shaped lower walls) and a cone. Various effects of combined creeping flow hydrodynamic interactions between the particle and walls are observed. Received: 12 March 1999 / Accepted: 7 June 2001 Published online: 29 November 2001  相似文献   

2.
A new approach for simultaneous planar measurement of droplet velocity and size with gas phase velocities is reported, which combines the out-of-focus imaging technique ‘Interferometric Laser Imaging Droplet Sizing’ (ILIDS) for planar simultaneous droplet size and velocity measurements with the in-focus technique ‘Particle Image Velocimetry’ (PIV) for gas velocity measurements in the vicinity of individual droplets. Discrimination between the gas phase seeding and the droplets is achieved in the PIV images by removing the glare points of focused droplet images, using the droplet position obtained through ILIDS processing. Combination of the two optical arrangements can result in a discrepancy in the location of the centre of a droplet, when imaging through ILIDS and PIV techniques, of up to about 1 mm, which may lead to erroneous identification of the glare points from droplets on the PIV images. The magnitude of the discrepancy is a function of position of the droplet’s image on the CCD array and the degree of defocus, but almost independent of droplet size. Specifically, it varies approximately linearly across the image along the direction corresponding to the direction of propagation of the laser sheet for a given defocus setting in ILIDS. The experimental finding is supported by a theoretical analysis, which was based on geometrical optics for a simple optical configuration that replicates the essential features of the optical system. The discrepancy in the location was measured using a monodisperse droplet generator, and this was subtracted from the droplet centres identified in the ILIDS images of a polydisperse spray without ‘seeding’ particles. This reduced the discrepancy between PIV and ILIDS droplet centres from about 1 mm to about 0.1 mm and hence increased the probability of finding the corresponding fringe patterns on the ILIDS image and glare points on the PIV image. In conclusion, it is shown that the proposed combined method can discriminate between droplets and ‘seeding’ particles and is capable of two-phase measurements in polydisperse sprays.  相似文献   

3.
A digital in-line holographic particle tracking velocimetry (HPTV) system was developed to measure 3D (three-dimensional) velocity fields of turbulent flows. The digital HPTV (DHPTV) procedure consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the recording step, a digital CCD camera was used as a recording device. Holograms contained many unwanted images or noise. To get clean holograms, digital image processing techniques were adopted. In the velocity extraction routine, we improved the HPTV algorithm to extract 3D displacement information of tracer particles. In general, the results obtained using HPTV were not fully acceptable due to technical limitations such as low spatial resolution, small volume size, and low numerical aperture (NA). The problems of spatial resolution and NA are closely related with a recording device. As one experimental parameter that can be optimized, we focused on the particle number density. Variation of the reconstruction efficiency and recovery ratio were compared quantitatively with varying particle number density to check performance of the developed in-line DHPTV system. The reconstruction efficiency represented the particle number distribution acquired through the numerical reconstruction procedure. In addition the recovery ratio showed the performance of 3D PTV algorithm employed for DHPTV measurements. The particle number density in the range of C o = 13–17 particles/mm3 was found to be optimum for the DHPTV system tested in this study.  相似文献   

4.
CH double-pulsed PLIF measurement in turbulent premixed flame   总被引:1,自引:0,他引:1  
The flame displacement speeds in turbulent premixed flames have been measured directly by the CH double-pulsed planar laser-induced fluorescence (PLIF). The CH double-pulsed PLIF systems consist of two independent conventional CH PLIF measurement systems and laser beams from each laser system are led to same optical pass using the difference of polarization. The highly time-resolved measurements are conducted in relatively high Reynolds number turbulent premixed flames on a swirl-stabilized combustor. Since the time interval of the successive CH PLIF can be selected to any optimum value for the purpose intended, both of the large scale dynamics and local displacement of the flame front can be discussed. By selecting an appropriate time interval (100–200 μs), deformations of the flame front are captured clearly. Successive CH fluorescence images reveal the burning/generating process of the unburned mixtures or the handgrip structures in burnt gas, which have been predicted by three-dimensional direct numerical simulations of turbulent premixed flames. To evaluate the local flame displacement speed directly from the successive CH images, a flame front identification scheme and a displacement vector evaluation scheme are developed. Direct measurements of flame displacement speed are conducted by selecting a minute time interval (≈30 μs) for different Reynolds number (Re λ = 63.1–115.0). Local flame displacement speeds coincide well for different Reynolds number cases. Furthermore, comparisons of the mean flame displacement speed and the mean fluid velocity show that the convection in the turbulent flames will affect the flame displacement speed for high Reynolds number flames.  相似文献   

5.
 The work presented here concentrates on the boiling heat transfer from a porous bed with internal heat sources. This configuration can occur, when in the progress of a hypothetical accident the core melt relocates to the lower plenum of a nuclear reactor pressure vessel and gets partially fragmented. The coolability and the boiling heat transfer are experimentally investigated for two- dimensional particle beds. Experiments are discussed with particles of an uniform diameter of 2 mm as well as mixtures of 4 mm and 1 mm particles. The bed was placed in a glass container with an inclined bottom to represent a section of the lower plenum of a reactor pressure vessel. The refrigerant R134a was used for tests with a pressure up to 1.8 MPa. The particle bed was equipped with thermocouples and capacitive local void fraction probes to map the temperatures and the distribution of liquid and steam. In the following the basic effects and the parameters influencing the coolability of such a configuration will be discussed. Received on 1 March 2001  相似文献   

6.
The present paper points out that all existing laser-Doppler anemometer systems do not only operate within a finite range of Doppler frequencies but also work within a relatively narrow range of signal amplitudes. It is shown that this corresponds to a finite, and usually to an extremely small, range of particle diameters which contributes to the final LDA measurements. Because of this, the particle size distribution has to be matched to the LDA-system used for measuring particle velocities. If this is not taken into account in particle seeding, low data rates will result in spite of very high particle passage rates through the measuring control volume. This is shown experimentally and is supported by theoretical considerations.The present investigation results in conclusions regarding optimum particle size distributions for laser-Doppler anemometry. If fluid velocity measurements are attempted rather than particle velocity measurements, the particles still have to satisfy well known size requirements that are flow, fluid and particle density dependent.The experimental study employs a combined optical system for simultaneous measurements of particle velocity, particle size and particle concentration. The system is used to measure those particles of a spectrum of oil droplets that contribute to the validated signal output of counter and transient recorder based LDA-electronic signal processing systems.  相似文献   

7.
8.
An apparatus was designed and built to explore the effects of transient flow fluctuations on the dynamic behavior of particles in low Reynolds number (LRN) flows. While many experiments have been performed on LRN particle flows, relatively few have investigated periodic oscillations on the flow dynamics. The apparatus was oscillated at a frequency of 10 Hz with peak-to-peak displacements on the order of 10 mm. Particles of varying densities and diameters were placed into the oscillating flow. Video images of the particle dynamics were captured with both a personal video camcorder and high-speed digital camera. In parallel, computations were performed for the particle system in order to validate the experimental method and apparatus. Received: 25 February 2000/Accepted: 5 September 2000  相似文献   

9.
 A model for fine particle agglomeration in circulating fluidized bed absorbers (CFBAs) has been developed. It can model the influence of different factors on agglomeration, such as the geometry of a CFBA, the superficial gas velocity, initial particle size distribution (PSD), and type of agglomeration mechanism. It is found that the Brownian agglomeration mechanism can be neglected compared to agglomeration by mean shear and turbulence. Sorbent particles are shown to capture fine particles effectively for certain conditions. Received on 17 August 2000 / Published online: 29 November 2001  相似文献   

10.
 Fluid-flow analysis using particle tracking seeks to assign velocity vectors to sequences of still images (tracks) of particles suspended in a transparent fluid or gas. This requires that high quality particle images be obtained from a system of moving particles. In practice, however, the images are contaminated by a variety of noise sources which must be removed before tracking can be performed. The traditional approach to prefiltering, which is being used in commercially-available systems, is to perform background subtraction in concert with some form of thresholding and/or image stretching. Unfortunately, these methods can attenuate particle images so badly that valid track yields are significantly reduced. In place of these methods, we present a non-attenuating background subtraction method with outlier rejection together with a non-attenuating substitute for thresholding.These algorithms have been tested on real track data and can recover virtually all images of particles in suspension with very little attenuation of particle-image intensity. Received: 1 February 1996/Accepted: 25 June 1996  相似文献   

11.
Volume self-calibration for 3D particle image velocimetry   总被引:4,自引:2,他引:2  
Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error (‘disparity’) is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.  相似文献   

12.
In this paper the peak-locking phenomenon is investigated in the evaluation of digital PIV recordings by using a correlation-based interrogation algorithm with a discrete window shift and a correlation-based tracking algorithm. Statistical analyses indicate that nonuniformly distributed bias errors are the main cause of the peak-locking effect, and the amplitude variation of the random error is also an important source of the peak locking. Simulations and experimental examples demonstrate that very strong peak-locking effects exist for the correlation-based interrogation algorithm with discrete window shift in the cases of large particle images, small interrogation windows, and very small particle images. Very strong peak-locking effects are also observed for the correlation-based tracking algorithm when the particle images are overexposed, binarized, or very small. These strong peak-locking effects can be avoided without loss of evaluation accuracy by using a continuous window-shift technique in combination with the correlation-based interrogation algorithm. Received: 2 July 2001 / Accepted: 28 November 2001  相似文献   

13.
Application of particle image velocimetry (PIV) techniques for measurement of fluid velocities typically requires two steps. The first of these is the photography step in which one or more exposures of a particle field are taken. The second step is the evaluation of the particle pattern and production of appropriate velocities. Each of these steps involves optimization which is usually specific to the experiment being conducted and there is significant interaction between photographic parameters and evaluation characteristics.Among the various evaluation techniques suggested for analysis of PIV images is the evaluation of the scattered interference pattern (Young's fringes) by numerical Fourier transform. An alternative to the numerical calculation of the Fourier transform of the Young's fringes has been suggested, using a modified liquid crystal television as an optical correlator to allow the transform to be performed optically. Both transform techniques are affected by the quality of the input function, specifically the Young's fringes.This paper will compare the performance of optical and numerical Fourier transform analysis of Young's fringes using speckle images. The repeatability and an estimate of the accuracy of the particle displacement will be shown for each method. A brief examination of the effects of small particle number density of PIV evaluation will also be presented. Finally, for a small part of an actual unsteady flow, the optical and numerical Fourier transform analysis methods will be compared.  相似文献   

14.
PIV measurements of a microchannel flow   总被引:24,自引:0,他引:24  
 A particle image velocimetry (PIV) system has been developed to measure velocity fields with order 1-μm spatial resolution. The technique uses 200 nm diameter flow-tracing particles, a pulsed Nd:YAG laser, an inverted epi-fluorescent microscope, and a cooled interline-transfer CCD camera to record high-resolution particle-image fields. The spatial resolution of the PIV technique is limited primarily by the diffraction-limited resolution of the recording optics. The accuracy of the PIV system was demonstrated by measuring the known flow field in a 30 μm×300 μm (nominal dimension) microchannel. The resulting velocity fields have a spatial resolution, defined by the size of the first window of the interrogation spot and out of plane resolution of 13.6 μm× 0.9 μm×1.8 μm, in the streamwise, wall-normal, and out of plane directions, respectively. By overlapping the interrogation spots by 50% to satisfy the Nyquist sampling criterion, a velocity-vector spacing of 450 nm in the wall-normal direction is achieved. These measurements are accurate to within 2% full-scale resolution, and are the highest spatially resolved PIV measurements published to date. Received: 29 October 1998/Accepted: 10 March 1999  相似文献   

15.
Particle image velocimetry incorporates a process by which an image of a flow field, bearing double images of seeding particles, is analyzed in small regions called “interrogation spots.” Each spot is imaged onto a photodetector array whose digitized output is evaluated computationally using the auto-correlation technique. This paper examines the effects of resolving the spot using arrays of various resolutions, motivated primarily by a gain in speed. For this purpose, two specially created test photographs representing (i) uniform flow and (ii) solid body rotation, were interrogated using array sizes ranging from 32 × 32 to 256 × 256. Each reduction in resolution by a factor of two gains a factor of four in interrogation speed, but this benefit is counteracted by a loss in accuracy. The particle image diameter strongly influences accuracy through two distinct error mechanisms. When the particle image is small compared to the pixel size, mean bias error becomes significant due to finite numerical resolution of the correlation function. Conversely, when the particle image is large, random error due to irregularities in the electronic images predominates. The optimum image size, therefore, lies not at either extreme but at an intermediate value such that the particle image is small in an absolute sense, and yet large relative to the pixel size. A version of this paper was presented at the 12th Symposium on Turbulence, University of Missouri-Rolla, 24–26 September 1990  相似文献   

16.
Digital micro holographic particle tracking velocimetry (HPTV) was used to measure the three-dimensional (3D) velocity field of a laminar flow in a curved micro-tube with a circular cross-section. The micro HPTV system consists of a high-speed camera and a single laser with an acoustic optical modulator (AOM) chopper. We obtained the temporal evolution of the instantaneous velocity field of water flow within curved micro-tubes with inner diameters of 100 and 300 μm. The 3D mean velocity-field distribution was obtained quantitatively by statistically averaging the instantaneous velocity fields. At low Dean numbers (De), a secondary flow was not generated in the curved tube; however, with increasing Dean number a secondary flow consisting of two large-scale counter-rotating vortices arose due to enhanced centrifugal force. To reveal the flow characteristics at high Dean numbers, the trajectories of fluid particles were evaluated experimentally from the 3D velocity-field data measured using the HPTV technique. The present experimental results, especially the 3D particle trajectories, are likely to be helpful in understanding mixing phenomena in curved sections of various 3D curved micro-tubes or micro-channels, as well as in the design of such structures.  相似文献   

17.
Real-time image processing for particle tracking velocimetry   总被引:2,自引:1,他引:1  
We present a novel high-speed particle tracking velocimetry (PTV) experimental system. Its novelty is due to the FPGA-based, real-time image processing “on camera”. Instead of an image, the camera transfers to the computer using a network card, only the relevant information of the identified flow tracers. Therefore, the system is ideal for the remote particle tracking systems in research and industrial applications, while the camera can be controlled and data can be transferred over any high-bandwidth network. We present the hardware and the open source software aspects of the PTV experiments. The tracking results of the new experimental system has been compared to the flow visualization and particle image velocimetry measurements. The canonical flow in the central cross section of a a cubic cavity (1:1:1 aspect ratio) in our lid-driven cavity apparatus is used for validation purposes. The downstream secondary eddy (DSE) is the sensitive portion of this flow and its size was measured with increasing Reynolds number (via increasing belt velocity). The size of DSE estimated from the flow visualization, PIV and compressed PTV is shown to agree within the experimental uncertainty of the methods applied.  相似文献   

18.
The relationship between particle size distribution and viscosity of concentrated dispersions is of great industrial importance, since it is the key to get high solids dispersions or suspensions. The problem is treated here experimentally as well as theoretically for the special case of strongly interacting colloidal particles. An empirical model based on a generalized Quemada equation is used to describe η as a function of volume fraction for mono- as well as multimodal dispersions. The pre-factor η˜ accounts for the shear rate dependence of η and does not affect the shape of the η vs φ curves. It is shown here for the first time that colloidal interactions do not show up in the maximum packing parameter and φmax can be calculated from the particle size distribution without further knowledge of the interactions among the suspended particles. On the other hand, the exponent ɛ is controlled by the interactions among the particles. Starting from a limiting value of 2 for non-interacting either colloidal or non-colloidal particles, ɛ generally increases strongly with decreasing particle size. For a given particle system it then can be expressed as a function of the number average particle diameter. As a consequence, the viscosity of bimodal dispersions varies not only with the size ratio of large to small particles, but also depends on the absolute particle size going through a minimum as the size ratio increases. Furthermore, the well-known viscosity minimum for bimodal dispersions with volumetric mixing ratios of around 30/70 of small to large particles is shown to vanish if colloidal interactions contribute significantly. Received: 7 June 2000/Accepted: 12 February 2001  相似文献   

19.
 Particle Image Velocimetry (PIV) is now a well established experimental technique to measure two components of the velocity in a planar region of a flow field. This paper shows how its proven capabilities can be further extended by using holographic recording to register the particle displacements. Among other unique characteristics, holography enables the acquisition of multiple images on a single plate, and the recording of three dimensional images. These features are used to circumvent some of the limitations of conventional PIV. Some of these possibilities are demonstrated in this study by applying the technique to a high Reynolds number swirling flow using a lens-less off-axis orthogonal recording geometry. Received: 25 February 1998/ Accepted: 2 September 1998  相似文献   

20.
The depth of correlation (DOC) is an experimental parameter, introduced to quantify the thickness of the measurement volume and thus the depth resolution in microscopic particle image velocimetry (μPIV). The theory developed to estimate the value of the DOC relies on some approximations that are not always verified in actual experiments, such as a single thin-lens optical system. In many practical μPIV experiments, a deviation of the actual DOC from its nominal value can be expected, due for instance to additional components present in the optical path of the microscope or to the use of image preprocessing before the PIV evaluation. In the presented paper, the effect of real particle image intensity distribution and image preprocessing on the thickness of the measurement volume is investigated. This is performed studying the defocusing of tracer particles and the DOC-related bias error present in μPIV measurements in a Poiseuille flow. The analysis shows that the DOC predicted using the conventional formulas can be significantly smaller than its actual value. To overcome this problem, the use of an effective NA determined experimentally from the curvature of the image autocorrelations is proposed. The accuracy of this approach to properly predict the actual size of DOC is discussed and validated on the experimental data. The effectiveness of image preprocessing to reduce the DOC-related bias error is tested and discussed as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号