首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error.  相似文献   

2.
A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.  相似文献   

3.
Capsazepine is an antagonist of the transient receptor potential channel vanilloid 1 (TRPV1), which is known to play an important role in the regulation of pain and inflammation. A selective and sensitive quantitative method for the determination of capsazepine by HPLC‐ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray quadrupole ion trap mass spectrometry. The chromatographic separation was achieved using a 100 × 2 mm C18 Waters Symmetry column combined with a gradient mobile phase composed of acetonitrile and 0.1% formic acid aqueous solution at a flow rate of 220 µL/min. The mass spectrometer was operating in full‐scan MS/MS mode using two‐segment analysis. An analytical range of 10–5000 ng/mL was used in the calibration curve constructed in rat plasma. The inter‐batch precision and accuracy observed were 10.1, 6.4 and 6.1% and 100.8, 98.5 and 106.2% at 50, 500 and 5 000 ng/mL, respectively. An in vitro metabolic stability using rat, dog or mouse liver microsomes was performed to determine the intrinsic clearance of capsazepine. The results suggest a very rapid degradation with T1/2 ranging from 2.6 to 4.3 min and a high clearance, suggesting that drug bioavailability is considerably reduced following extravascular administrations, consequently affecting drug response. Three metabolites were identified by HPLC‐MS/MS. S‐hydroxylation (M + 16), oxidative desulfuration (M − 16) and desulfuration (M − 32) metabolites of capsazepine were observed following exposure to rat, dog and mouse microsomes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
An ion-pairing high-performance liquid chromatographic (IP-HPLC) system interfaced with an atmospheric pressure chemical ionization (APCI) source and a tandem mass spectrometer (MS/MS) with minimal sample preparation was developed for the determination of cytarabine (ara-C), a very hydrophilic anticancer drug, in mouse plasma. A conventional reversed-phase chromatographic column in combination with two ion-pairing reagents was adapted for retention and separation of ara-C from the endogenous interferences in mouse plasma. The effects of the experimental conditions such as the fraction of ion-pairing reagents and organic solvents in the mobile phase on the chromatographic performance and the ionization efficiency of ara-C were investigated. The potential of ionization suppression resulting from the endogenous biological materials on the IP-HPLC/MS/MS method was evaluated using the post-column infusion technique. Furthermore, the feasibility of the proposed IP-HPLC/MS/MS procedure for analysis of ara-C in the mouse plasma was demonstrated by comparison with those obtained by the porous graphite carbon column (PGC) HPLC/MS/MS method.  相似文献   

5.
A high-temperature liquid chromatographic technique is employed for the separation of commercially available polymer additives to enhance the resolution and speed. Separation efficiencies and elution behaviors for seven phthalate plasticizers and five antioxidants are evaluated at elevated column temperatures and with a thermal gradient. Diamondbond C18 (octadecylsilica), Zirchrom PS (zirconia-based polystyrene), and Zirchrom PBD (zirconia-based polybutadiene) columns are selected for the study because of their thermal stability. The temperature programming is controlled with a column oven in conjunction with an independent mobile phase preheater and a post-column effluent cooling assembly. Van't Hoff plots show that the reverse-phase liquid chromatography mechanism is maintained over a wide range of column temperatures. A 1% increase of acetonitrile in the mobile phase is estimated to have a comparable effect as a 7-7.5 degrees C column temperature increase on the retention time changes.  相似文献   

6.
A high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry (MS/MS) method was developed for rapid determination of 13 isoflavones in Radix puerariae. A novel shell-type column, namely Kinetex core-shell C(18) column (50 mm×2.1 mm id, 2.6 μm), and gradient elution were used during the analysis. The chromatographic peaks of 13 investigated compounds were identified by comparing their retention time and MS data with the related reference compounds. Multiple-reaction monitoring (MRM) was employed for the quantitative analysis with negative ionization mode. All calibration curves showed good linearity (r(2)>0.9990) within test ranges. The LOD and LOQ were lower than 0.017 and 0.873 μg/mL on column, respectively. The intra- and inter-day precisions for 13 analytes were <1.17 and 2.17%, respectively, and the recoveries were 93.1-104.4%. The validated method was applied for quantitative analysis of 13 isoflavones in 7 species of Radix puerariae. The result demonstrated that HPLC-MS/MS system with Kinetex column could be a promising analytical tool for the determination of isoflavones in traditional Chinese medicines, which is helpful for comprehensive evaluation of quality of R. puerariae.  相似文献   

7.
Nano-LC and conventional HPLC techniques were applied for the analysis of anthocyanins present in commercial fruit juices using a capillary column of 100 μm id and a 2.1 mm id narrow-bore C(18) column. Analytes were detected by UV-Vis at 518 nm and ESI-ion trap MS with HPLC and nano-LC, respectively. Commercial blueberry juice (14 anthocyanins detected) was used to optimize chromatographic separation of analytes and other analysis parameters. Qualitative identification of anthocyanins was performed by comparing the recorded mass spectral data with those of published papers. The use of the same mobile phase composition in both techniques revealed that the miniaturized method exhibited shorter analysis time and higher sensitivity than narrow-bore chromatography. Good intra-day and day-to-day precision of retention time was obtained in both methods with values of RSD less than 3.4 and 0.8% for nano-LC and HPLC, respectively. Quantitative analysis was performed by external standard curve calibration of cyanidin-3-O-glucoside standard. Calibration curves were linear in the concentration ranges studied, 0.1-50 and 6-50 μg/mL for HPLC-UV/Vis and nano-LC-MS, respectively. LOD and LOQ values were good for both methods. In addition to commercial blueberry juice, qualitative and quantitative analysis of other juices (e.g. raspberry, sweet cherry and pomegranate) was performed. The optimized nano-LC-MS method allowed an easy and selective identification and quantification of anthocyanins in commercial fruit juices; it offered good results, shorter analysis time and reduced mobile phase volume with respect to narrow-bore HPLC.  相似文献   

8.
A rapid, sensitive and selective LC‐MS/MS method for the quantitative analysis of 3‐hydroxy pterocarpan (S006‐1709) in female rat plasma has been developed and validated. A Discovery RP18 column was used for the chromatographic elution using acetonitrile and 0.1% acetic acid in water as mobile phase (80:20 v/v) at the flow rate of 0.5 mL/min. MS/MS analysis was performed using a triple quadrupole mass spectrometer with electrospray ionization in negative ion mode using biochanin as an internal standard (IS). Extraction of S006‐1709 and IS from rat plasma was done by liquid–liquid extraction method using diethyl ether. The LC‐MS/MS method was sensitive with 1.95 ng/mL as the limit of detection and 3.9 ng/mL as the lower limit of quantification. The method was linear in the concentration range of 3.9–1000 ng/mL. The percentage bias for intraday and interday accuracy was not greater than 4.2 and the %RSD for intraday and interday precision was not greater than 13.2. The recoveries of S006‐1709 and IS were 73.9–79.3 and 85.7%, respectively. S006‐1709 was found to be stable in various stability studies. The validated LC‐MS/MS method was successfully applied for the oral pharmacokinetics study of S006‐1709 at 10 mg/kg in female Sprague–Dawley rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A high‐performance liquid chromatographic (HPLC) method with integrated solid‐phase extraction for the determination of 1‐hydroxypyrene and 1‐, 2‐, 3‐, 4‐ and 9‐hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid‐phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core–shell column using a methanol gradient. For quantification, time‐programmed fluorescence detection was used. Matrix‐dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC‐fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra‐high‐performance liquid chromatography pentafluorophenyl core–shell column and coupled to a high‐resolution time‐of‐flight mass spectrometer (HR‐TOF‐MS). The resulting method was used to demonstrate the applicability of LC‐HR‐TOF‐MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter.  相似文献   

10.
Capsaicin is the most abundant pungent molecule present in red peppers and it is widely used for food flavoring, in pepper spray in self-defense devices and more recently in ointments for the relief of neuropathic pain. Capsaicin is a selective agonist of transient receptor potential channel, vanilloid subfamily member 1. A selective and sensitive quantitative method for the determination of capsaicin by LC-ESI/MS/MS was developed. The method consisted of a protein precipitation extraction followed by analysis using liquid chromatography electrospray quadrupole ion trap mass spectrometry. The chromatographic separation was achieved using a 100 x 2 mm C(18) Waters Symmetry column combined with a gradient mobile phase composed of acetonitrile and 0.1% formic acid aqueous solution at a flow rate of 220 microL/min. The mass spectrometer was operating in full-scan MS/MS mode using two-segment analysis. An analytical range of 10-5000 ng/mL was used in the calibration curve constructed in rat plasma. The interbatch precision and accuracy observed were 6.5, 6.7, 5.3 and 101.2, 102.7, 103.5% at 50, 500 and 5000 ng/mL, respectively. An in vitro metabolic stability study was performed in rat, dog and mouse liver microsomes and the novel analytical method was adapted and used to determine intrinsic clearance of capsaicin. Results suggest very rapid degradation with T(1/2) ranging from 2.3 to 4.1 min and high clearance values suggesting that drug bioavailability will be considerably reduced, consequently affecting drug response and efficacy.  相似文献   

11.
窦建鹏  宋凤瑞  刘志强  刘淑莹 《化学学报》2009,67(22):2613-2618
建立了长白山区朝鲜淫羊藿药材的高效液相色谱指纹图谱的分析方法. 确定了18批朝鲜淫羊藿药材的13个共有峰, 该指纹图谱的精密度、稳定性和重现性的相对标准偏差均低于3.0%. 结合液相色谱/电喷雾串联质谱对特征峰进行了结构确认, 并根据电喷雾串联质谱数据推测了13个特征化合物的结构. 结果表明采用高效液相色谱与质谱联用技术对朝鲜淫羊藿色谱指纹图谱中的特征峰进行结构确认, 使其色谱指纹图谱的特征性更强, 更适合于药材质量的鉴别与评价.  相似文献   

12.
A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids.  相似文献   

13.
A high-performance liquid chromatographic (HPLC) method coupled with ultraviolet (UV) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF/MS) was established for simultaneous qualitative and quantitative determination of nine phenolic acids and six diterpenoids in Radix et Rhizoma Salviae Miltiorrhizae (RRSM). The optimal chromatographic conditions were achieved on a Zorbax C(18) column by gradient elution with 0.1% (v/v) aqueous formic acid and acetonitrile as mobile phase at the flow rate of 1.0 mL/min. The detection wavelength at 281 nm was chosen to determine the 15 bioactive components, namely danshensu (1), protocatechuic acid (2), protocatechuic aldehyde (3), caffeic acid (4), rosmarinic acid (5), lithospermic acid (6), salvianolic acid B (7), salvianolic acid A (8), salvianolic acid C (9); dihydrotanshinone I (10), cryptotanshinone (11), tanshinone I (12), methylene tanshiqunone (13), tanshinone IIA (14) and miltirone (15). Additionally, LC-ESI-TOF/MS was used to make definite identification of the constituents in samples in comparison with those reference compounds. The validation of the method included tests of linearity, sensitivity, repeatability, stability and recovery. The proposed method was successfully applied to quantify the 15 components in 21 samples; significant variations were demonstrated in the contents of the samples from diverse species and origins. The developed method could be used to effectively and comprehensively evaluate the quality of RRSM for its clinical safety and efficacy.  相似文献   

14.
建立了一种简单、快速测定玩具中丙烯酰胺含量与迁移量的高效液相色谱法(HPLC).该方法以Waters Atlantis T3柱为分析柱,以纯水超声提取并作为流动相,采用HPLC对水中丙烯酰胺的含量及模拟汗液、唾液中丙烯酰胺的迁移量进行测定,并测定了自制阳性样品中的残留丙烯酰胺的含量,最后用液相色谱-串联质谱( LC-M...  相似文献   

15.
A high-performance liquid chromatographic (HPLC) method to determine retinol and all four tocopherols (alpha-, beta-, gamma- and delta-) simultaneously was established using a reversed-phase column (YMC-PACK A-302 S-5 120A ODS). The HPLC conditions were mobile phase 65% isopropanol, sample solvent 99.5% methanol and temperature 30 degrees C. Retinol and tocopherols were measured in rat liver.  相似文献   

16.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

17.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

18.
目前,β-内酰胺类抗生素在临床抗感染药物中占有十分突出的地位,但在近年来的药品不良反应报告中,抗生素类药物引起的不良反应也占据了很高的比例,其中有我国生活环境影响、感染性疾病多的客观因素,但病人用药盲目性大、医生用药随意性多的问题也普遍存在。因此,进一步加强对抗生素类药物的监测,开发快速有效的分析测试方法显得十分重要。本文基于实际全血未知样品,开发了基于固相萃取及液质联用技术,快速准确地对血液中青霉素G及头孢拉定进行定性及质谱定量分析的检测方法。  相似文献   

19.
A rapid, sensitive, and simple HPLC/MS/MS method was developed and validated for the determination of (5Z,E)-3-[2-(4-chlorophenyl)-2-oxoethyl]-5-(1H-indol-3-ylmethylene)-thiazolidine-2, 4-dione (PG15) in rat plasma using chlortalidone as an internal standard (IS). Analyses were performed using a C18 column and isocratic elution with acetonitrile-water (90 + 10, v/v) containing 10 mM ammonium hydroxide (pH 8.0) as the mobile phase pumped at 0.3 mL/min. Detection was performed by MS with negative ion mode electrospray ionization. Rat plasma samples were prepared by deproteinizing with acetonitrile. Detected fragments were 395.1 > 171.9 for PG15 and 337.3 > 189.9 for the IS. Calibration curves were linear from 10 to 1000 ng/mL, with the determination coefficient > 0.99. The intraday and interday precisions were less than 12.2 and 11.3%, respectively. The applicability of the HPLC/MS/MS method for pharmacokinetic studies was tested using plasma samples obtained after oral administration of PG15 to rats, and it provided the necessary sensitivity, linearity, precision, accuracy, and specificity.  相似文献   

20.
A highly sensitive and specific LC‐ESI‐MS/MS method has been developed and validated for simultaneous quantification of felodipine (FDP) and metoprolol (MPL) in rat plasma (50 μL) using phenacetin as an internal standard (IS) as per the FDA guidelines. Liquid–liquid extraction method was used to extract the analytes and IS from rat plasma. The chromatographic resolution of FDP, MPL and IS was achieved with a mobile phase consisting of 0.2% formic acid in water–acetonitrile (25:75, v/v) with a time program flow gradient on a C18 column. The total chromatographic run time was 4.0 min and the elution of FDP, MPL and IS occurred at 1.05, 2.59 and 1.65 min, respectively. A linear response function was established for the range of concentrations 0.59–1148 and 0.53–991 ng/mL for FDP and MPL, respectively, in rat plasma. The intra‐ and inter‐day accuracy and precision values for FDP and MPL met the acceptance as per FDA guidelines. FDP and MPL were stable in battery of stability studies viz., bench‐top, auto‐sampler and freeze–thaw cycles. The validated assay was applied to a pharmacokinetic study in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号