首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An interlaboratory study funded by the European Commission, Standards, Measurement and Testing Programme (4th Framework Programme) was performed to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in baby food at a possible future European regulatory limit (0.1 ng/g). The test portion is extracted in a blender with tert-butyl methyl ether (chosen to avoid use of chloroform but shown to give equivalent extraction efficiency) after addition of 0.5 mol/L phosphoric acid-2 mol/L sodium chloride solution. The extract is centrifuged and redissolved in a mixture of phosphate buffered saline solution and methanol. After removal of lypophilic substances with hexane, the extract is applied to an immunoaffinity column containing antibodies specific to ochratoxin A. The column is washed with water to remove the interfering compounds and the purified ochratoxin A is eluted with methanol. The separation and determination of ochratoxin A is performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) with ammonia. Test materials (baby food infant formulae), both spiked and naturally contaminated with ochratoxin A, were sent to 13 laboratories in 8 different European countries. Test portions were spiked at a level of 0.085 ng/g ochratoxin A. The average recovery for the spiked blank baby food was 108%. Based on results for spiked samples (blind pairs at 0.085 ng/g) as well as naturally contaminated samples (blind pairs at levels between 0.05 and 0.22 ng/g) the relative standard deviation for repeatability (RSDr) ranged from 18-36%. The relative standard deviation for reproducibility (RSDR) ranged from 29-63% and HORRAT values of between 0.4 and 0.9 were obtained.  相似文献   

2.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone-water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP-LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within- and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.  相似文献   

3.
A liquid chromatographic (LC) method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn and corn flakes was collaboratively studied by 23 laboratories, which analyzed 5 blind duplicate pairs of each matrix to establish the accuracy, repeatability, and reproducibility characteristics of the method. Fumonisin levels in the corn ranged from <0.05 (blank) to 1.41 microg/g for FB1 and from <0.05 to 0.56 microg/g for FB2, whereas in the corn flakes they ranged from <0.05 to 1.05 microg/g for FB1 and from <0.05 to 0.46 microg/g for FB2. The method involved double extraction with acetonitrile-methanol-water (25 + 25 + 50), cleanup through an immunoaffinity column, and LC determination of the fumonisins after derivatization with o-phthaldialdehyde. Relative standard deviations for the within-laboratory repeatability (RSDr) of the corn analyses ranged from 19 to 24% for FB1 and from 19 to 27% for FB2; for the corn flakes analyses, RSDr ranged from 9 to 21 % for FB1 and from 8 to 22% for FB2. Relative standard deviations for the between-laboratories reproducibility (RSDR) of the corn analyses ranged from 22 to 28% for FB1 and from 22 to 30% for the FB2; for corn flakes analyses, RSDR ranged from 27 to 32% for FB1 and from 26 to 35% for FB2. Mean recoveries of FB1 and FB2 from corn spiked with FB1 at 0.80 microg/g and with FB2 at 0.40 microg/g were 76 and 72%, respectively; for corn flakes spiked at the same levels recoveries were 110 and 97% for FB1 and FB2, respectively. HORRAT ratios for the analyses of corn ranged from 1.44 to 1.53 for FB1 and from 0.96 to 1.48 for FB2, whereas for corn flakes they ranged from 1.60 to 1.82 for FB1 and from 1.39 to 1.68 for FB2.  相似文献   

4.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.  相似文献   

5.
6.
An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatography (LC) method for the determination of zearalenone (ZON) in a variety of cereals and cereal products at proposed European regulatory limits. The test portion is extracted with acetonitrile:water. The sample extract is filtered, diluted, and applied to an affinity column. The column is washed, and ZON is eluted with acetonitrile. ZON is quantified by reversed-phase LC with fluorescence detection. Barley, wheat and maize flours, polenta, and a maize-based baby food naturally contaminated, spiked, and blank (very low level) were sent to 28 collaborators in 9 European countries and 1 collaborator in New Zealand. Participants were asked to spike test portions of all samples at a ZON concentration equivalent to 100 microg/kg. Average recoveries ranged from 91-111%. Based on results for 4 artificially contaminated samples (blind duplicates) and 1 naturally contaminated sample (blind duplicate), the relative standard deviation for repeatability (RSDr) ranged from 6.9-35.8%, and the relative standard deviation for reproducibility (RSDR) ranged from 16.4-38.2%. The method showed acceptable within- and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values <1.7.  相似文献   

7.
An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of deoxynivalenol in a variety of cereals and cereal products at proposed European regulatory limits. The test portion was extracted with water. The sample extract was filtered a applied to an immunoaffinity column. After being washed with water, the deoxynivalenol was eluted with acetonitrile or methanol. Deoxynivalenol was quantitated by reversed-phase LC with UV determination. Samples of artificially contaminated wheat-flour, rice flour, oat flour, polenta, and wheat based breakfast cereal, naturally contaminated wheat flour, and blank (very low level) samples of each matrix were sent to 13 collaborators in 7 European countries. Participants were asked to spike test portions of all samples at a range of deoxynivalenol concentrations equivalent to 200-2000 ng/g deoxynivalenol. Average recoveries ranged from 78 to 87%. Based on results for 6 artificially contaminated samples (blind duplicates), the relative standard deviation for repeatability (RSDr) ranged from 3.1 to 14.1%, and the relative standard deviation for reproducibility (RSDR) ranged from 11.5 to 26.3%. The method showed acceptable within-laboratory and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values < 1.3.  相似文献   

8.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.  相似文献   

9.
A single-laboratory method validation was conducted to establish the effectiveness of an immunoaffinity column cleanup procedure followed by liquid chromatography/mass spectrometry (LCIMS) for the determination of fumonisins B1 and B2 (FBI + FB2) in corn. The test portion is extracted with acetonitrile-methanol-water (25 + 25 + 50). The extract is filtered, diluted with phosphate-buffered saline solution, and applied to an immunoaffinity column. FB1 + FB2 are removed with methanol and directly determined by reversed-phase LC with MS detection using selected-ion monitoring of 2 characteristic ions in each case. Test portions of blank corn samples were spiked with a mixture of FB1 + FB2 to give total levels of 200 and 500 ng/g, respectively. Recoveries of both FB1 and FB2 from spiked samples averaged 90.4-101%. Based on results for spiked raw corn (triplicates at 2 levels), the relative standard deviation for repeatability ranged from 2.8 to 7.1%. The accuracy of the method was demonstrated by analysis of Food Analysis Performance Assessment Scheme (FAPAS) test material. The method was also applied to a small survey of processed corn products such as corn chips, cornflakes, and popcorn.  相似文献   

10.
A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol-water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.  相似文献   

11.
The accuracy, repeatability, and reproducibility characteristics of a liquid chromatographic method for the determination of ochratoxin A (OTA) in white wine, red wine, and beer were established in a collaborative study involving 18 laboratories in 10 countries. Blind duplicates of blank, spiked, and naturally contaminated materials at levels ranging from < or =0.01 to 3.00 ng/mL were analyzed. Wine and beer samples were diluted with a solution containing polyethylene glycol and sodium hydrogen carbonate, and the diluted samples were filtered and cleaned up on an immunoaffinity column. OTA was eluted with methanol and quantified by reversed-phase liquid chromatography with fluorometric detection. Average recoveries from white wine, red wine, and beer ranged from 88.2 to 105.4% (at spiking levels ranging from 0.1 to 2.0 ng/mL), from 84.3 to 93.1% (at spiking levels ranging from 0.2 to 3.0 ng/mL), and from 87.0 to 95.0% (at spiking levels ranging from 0.2 to 1.5 ng/mL), respectively. Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 6.6 to 10.8% for white wine, from 6.5 to 10.8% for red wine, and from 4.7 to 16.5% for beer. Relative standard deviations for between-laboratories reproducibility (RSDR) ranged from 13.1 to 15.9% for white wine, from 11.9 to 13.6% for red wine, and from 15.2 to 26.1% for beer. HORRAT values were < or =0.4 for the 3 matrixes.  相似文献   

12.
A single-laboratory validation was conducted to establish the effectiveness of an immunoaffinity column cleanup procedure followed by LC with fluorescence detection for the determination of aflatoxins B1, B2, G1, and G2 in sesame seeds. The sample is homogenized with 50% water (w/w) to form a slurry, then the test portion is extracted with methanol-water (60 + 40, v/v) using a high-speed blender. The sample extract is filtered, diluted with 15% Tween 20 in phosphate-buffered saline solution, and applied to an immunoaffinity column. Aflatoxins are removed with neat methanol, then directly determined by RP-LC with fluorescence detection using postcolumn bromination (Kobra cell). Test portions of blank white sesame seed slurry were spiked with a mixture of aflatoxins to give total levels of 4 and 10 microg/kg. Recoveries for individual and total aflatoxins ranged from 92.7 to 110.3% for spiked samples. Based on results for spiked sesame paste (triplicates at two levels), the RSD for repeatability (RSD(r)) averaged 1.1% for total aflatoxins and 1.4% for aflatoxin B1. The method was demonstrated to be applicable to naturally contaminated samples of black and white sesame seeds obtained from local markets in China.  相似文献   

13.
Niacin content must be included on food labels of infant formula products and bakery products containing enriched flour. Liquid chromatographic (LC) determination of niacin in complex food matrixes is complicated by the presence of endogenous compounds that absorb at the commonly used wave-length of 260 nm. Also, the presence of particulate matter in the standard sulfuric acid extraction procedure results in reduced life of LC columns and precolumns. A simple, rapid, solid-phase extraction (SPE) procedure for separation and cleanup of niacin from a complex food matrix digest has been developed. By using a vacuum manifold with the SPE column system, multiple samples can be processed quickly and efficiently for LC analysis, compared with gravimetric column cleanup. Sulfuric acid sample digest is passed over an aromatic sulfonic acid cation-exchange (ArSCX-SPE) or a sulfonated Florisil SPE column. Niacin is eluted with 0.25M sodium acetate-acetic acid, pH 5.6 buffer in vacuo. LC chromatograms of the resulting eluate are free of interference from other components absorbing at 260 nm at the retention time of niacin. Validation of the method was obtained from agreement of analytical results on available reference materials. For both SPE methods, values for niacin in SRM 1846 Infant Formula (milk-based powder) were within uncertainty ranges of the certified value. Use of several calibration procedures (the LC computer program, a peak area response graphic standard curve, or the method of standard additions) with both SPE procedures resulted in niacin values for 3 RM-Wheat Flours (not certified for niacin) in agreement (90-105%) with their respective values reported in the literature. Several commercial wheat flours showed a broad 260 nm interference, resulting in high niacin values. Niacin recoveries from spiked soy-based liquid infant formulas ranged from 95-107% with the ArSCX-SPE column. Calibration curves of niacin were linear up to 400 micrograms/mL, with a detection limit of 0.2 microgram/mL.  相似文献   

14.
Although analytical methods are available for the determination of aflatoxins in medicinal herbs, none of them can be applied satisfactorily to all sample matrices. The difficulty arises from the complex chemical composition of the herbs. Recovery is generally low by using immunoaffinity column cleanup due to the acidity of the water extractive leading to a weakened binding affinity. As a solvent for dilution and neutralization, phosphate buffer saline is useful for certain herbs but not for others that have high acidity. The problem can be solved by using 0.1 M phosphate buffer, which has a higher buffering capacity and eliminates sodium chloride. The modified method was validated by the analysis of a certified reference material and shown to be useful for the determination of aflatoxins in herbal samples of high acidity.  相似文献   

15.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol-water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSD(R)) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.  相似文献   

16.
The accuracy, repeatability, and reproducibility characteristics of a method using multitoxin immunoaffinity column cleanup with liquid chromatography (LC) for determination of aflatoxins (AF; sum of aflatoxins B1, B2, G1, and G2) and ochratoxin A (OTA) in powdered ginseng and ginger have been established in a collaborative study involving 13 laboratories from 7 countries. Blind duplicate samples of blank, spiked (AF and OTA added) at levels ranging from 0.25 to 16.0 microg/kg for AF and 0.25 to 8.0 microg/kg for OTA were analyzed. A naturally contaminated powdered ginger sample was also included. Test samples were extracted with methanol and 0.5% aqueous sodium hydrogen carbonate solution (700 + 300, v/v). The extract was centrifuged, diluted with phosphate buffer (PB), filtered, and applied to an immunoaffinity column containing antibodies specific for AF and OTA. After washing the column with water, the toxins were eluted from the column with methanol, and quantified by high-performance LC with fluorescence detection. Average recoveries of AF from ginseng and ginger ranged from 70 to 87% (at spiking levels ranging from 2 to 16 microg/kg), and of OTA, from 86 to 113% (at spiking levels ranging from 1 to 8 microg/kg). Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 2.6 to 8.3% for AF, and from 2.5 to 10.7% for OTA. Relative standard deviations for between-laboratory reproducibility (RSDR) ranged from 5.7 to 28.6% for AF, and from 5.5 to 10.7% for OTA. HorRat values were < or = 2 for the multi-analytes in the 2 matrixes.  相似文献   

17.
A sensitive and very selective high-performance liquid chromatography/tandem mass spectrometric (LC/MS/MS) method for the detection of halofuginone in whole egg has been developed. After deproteinisation with acetonitrile and evaporation of the organic solvent, halofuginone was further isolated by applying immunoaffinity chromatography. The concentrated eluent was injected into the LC/MS/MS system on a C18 column. The precursor ion ([M+H]+) produced by positive electrospray ionisation was selected for fragmentation with argon. Validation parameters such as recovery, linearity and repeatability, decision limit (CCalpha) and detection capability (CCbeta) were determined.  相似文献   

18.
At the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," on June 29, 2011, an Expert Review Panel agreed that the method "Determination of Vitamin B12 in Infant Formulas and Adult Nutritionals by Liquid Chromatography/UV Detection with Immunoaffinity Extraction" be adopted AOAC Official First Action status. The method is applicable for the determination of vitamin B12, which includes added cyanocobalamin and natural forms, making it applicable to both fortified and nonfortified products. Vitamin B12 is extracted from the sample in sodium acetate buffer in the presence of sodium cyanide (100 degrees C, 30 min). After purification and concentration with an immunoaffinity column, vitamin B12 is determined by LC with UV detection (361 nm). A single-laboratory validation study was conducted on a range of products, including milk- and soy-based infant formulas, cereals, cocoa beverages, health care products, and polyvitamin premixes. The method demonstrated linear response over a large range of concentrations, recovery rates of 100.8 +/- 7.5% (average +/- SD), repeatability RSD (RSDr) of 2.1%, and intermediate reproducibility (RSD(iR)) of 4.3%. LOD and LOQ values were 0.10 and 0.30 microg/100 g, respectively, and correlation with the reference microbiological assay was good (R2 = 0.9442). The results of the study were published in J. AOAC Int. 91, 786-793 (2008). The performance characteristics of the method met the standard method performance requirements set forth by the Stakeholder Panel on Infant Formula and Adult Nutritionals; thus, the method was determined to be appropriate for First Action status.  相似文献   

19.
A collaborative study was conducted to evaluate a liquid chromatographic (LC) method with immunoaffinity column cleanup for determination of ochratoxin A. The method was tested at 3 concentration levels of ochratoxin A in barley, which represent possible future European regulatory limits. The test portion was extracted with acetonitrile-water by blending at high speed. The extract was filtered, diluted with phosphate-buffered saline (PBS), and applied to an ochratoxin A immunoaffinity column. The column was washed with water and the ochratoxin A eluted with methanol. The solvent was then evaporated and the residue redissolved in injection solvent. After injection of this solution onto reversed-phase LC column, ochratoxin A was measured by fluorescence detection. Eight samples of low level naturally contaminated barley and 2 samples of blank barley (ochratoxin A not found at the limit of detection of 0.2 microg/kg at the signal-to-noise ratio of 3 to 1) were sent, along with ampules of ochratoxin A, calibrant, and spiking solutions, to 15 laboratories in 13 different European countries. Test portions were spiked with ochratoxin A at levels of 4 ng/g, and recoveries ranged from 65 to 113%. Based on results for spiked samples (blind duplicates) and naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 4 to 24%, and the relative standard deviation for reproducibility (RSDR) ranged from 12 to 33%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in barley.  相似文献   

20.
游丽娜  李贤良  郗存显  唐柏彬  王国民  张雷  袁中珍  赵华 《色谱》2012,30(10):1021-1025
建立了鸡蛋中6种玉米赤霉醇类化合物(α-玉米赤霉醇、β-玉米赤霉醇、α-玉米赤霉烯醇、β-玉米赤霉烯醇、玉米赤霉酮和玉米赤霉烯酮)残留量的免疫亲和柱净化-高效液相色谱检测方法。样品酶解后用叔丁基甲醚提取、氢氧化钠反萃取,经免疫亲和柱富集和净化后,采用高效液相色谱-紫外检测器进行测定。色谱柱: Agilent Eclipse XDB-C18(150 mm×4.6 mm, 3.5 μm);流动相: 甲醇-乙腈-水(50:15:35, v/v/v);流速: 1.0 mL/min;检测波长: 270 nm。结果表明,6种目标物在0.01~0.2 mg/L范围内线性关系良好,相关系数(r)≥0.9998,检出限(LOD,S/N≥3)为1.0 μg/kg,平均回收率为73.2%~95.7%,相对标准偏差小于8%。该方法灵敏度高、重现性好,适用于鸡蛋样品中痕量玉米赤霉醇类药物残留的测定。  相似文献   