首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel chemiluminescence(CL) flow system for sulfite is described based on electrostatically immobilized luminol on an anion exchange column. Sulfite is detected by the CL reaction with luminol bleeding from the column by hydrolysis. The calibration graph is linear in the range 3 × 10–7 to 1 × 10–5 mol/L, and the detection limit is 1 × 10–7 mol/L. Interfering metal ions co-existing in sample solutions could be effectively eliminated on-line by an upstream cation exchanger. A complete analysis could be performed in 1 min with a relative standard deviation of less than 5%. The system could be reused for over 50 h and has been applied successfully to the determination of sulfur dioxide in air. Received: 21 October 1997 / Revised: 23 February 1998 / Accepted: 26 February 1998  相似文献   

2.
张四纯  周国俊  鞠熀先 《中国化学》2002,20(10):1049-1054
IntroductionGallicacidexistsintheleavesandfruitsofmanytypesofplantsandiswidelyusedinmedicineforanti oxi dationandantibacterialactivity ,antiflammatoryactionandanti canceractivity .1 5Inspiteofthehealthimportanceofgallicacid ,itsmetabolismandkineticsinthehu…  相似文献   

3.
A flow-through CL method for the determination of lead combined with controlled-reagent-release technology has been developed. Chemiluminescence (CL) reagents luminol and potassium permanganate were immobilized on anion exchange resin by electrostatic interaction. Lead ion was determined by its enhancing effect on the CL reaction between luminol and potassium permanganate. Both luminol and potassium permanganate were eluted from the anion exchange resin column by sodium phosphate solution. The linear range of the system was 10 μg mL?1, and the detection limit was 5?×?10–9 g mL?1 lead (3σ). A complete analysis could be performed in 1 min with a relative SD 3.2% (1.0?×?10–7 g mL?1, n?=?9). The column shows remarkable stability and can be reused over 350 times and 21 days. The method has been applied to determine lead in human blood samples.  相似文献   

4.
A novel chemiluminescence (CL) flow system has been developed for the sequential determination of Fe(II) and Fe(III) in water. Fe(II) was detected by its catalytic effect on the CL reaction between luminol immobilized on an anion exchange resin column and dissolved oxygen; Fe(III) was determined by difference measurement after on-line conversion to Fe(II) in a reducing mini-column packed with Cu plated Zn granules. For both ions, the calibration graph was linear in the range 1 × 10–9 to 1 × 10–6 g/mL, and the detection limit was 4 × 10–10 g/mL. A complete analysis could be performed in 1.5 min with a relative standard deviation of less than 5%. The system could be reused for over 200 times and has been applied successfully to the determination of Fe(II) and Fe(III) in natural water samples.  相似文献   

5.
A simple, rapid and accurate high performance liquid chromatographic (HPLC) technique coupled with chemiluminescence (CL) detection was developed for the simultaneous determination of epinephrine (E), noradrenaline (NA) and dopamine (DA). It was based on the analyte enhancement effect on the CL reaction between luminol and potassium ferricyanide. The effects of various parameters, such as potassium ferricyanide concentration, luminol concentration, pH value and component of the mobile phase on chromatographic behaviors of the analytes (E, NA and DA) were investigated. The separation was carded out on C18 column using the mobile phase of 0.01 mol/L potassium hydrogen phthalate solution and methanol (92 : 8, V/V). Under the optimum condi- tions, E, NA and DA showed good linear relationships in the range of 1 × 10^-8 -5 × 10^-6, 5.0× 10^-9 -1.0× 10^-6 and 5.0×10^-9-1.0× 10^-6 g]mL respectively. The detection limits for E, NA and DA were 4.0×10^-9, 1.0× 10^-9 and 8.0 × 10^-10 g/mL. The proposed method has been applied successfully to the analysis of E, NA and DA in human serum samples.  相似文献   

6.
A novel chemiluminescence (CL) method for the determination of hydrogen peroxide is described. Method is based on the transition metals in highest oxidation state complex, which include diperiodatoargentate (DPA) and diperiodatonickelate (DPN) and show excellent sensitisation on the luminol-H2O2 CL reaction with low luminol concentration in alkaline medium. In particular, the sensitiser which was previously reported (such as Co2+, Cu2+, Ni2+, Mn2+, Fe3+, Cr3+, KIO4, K3Fe(CN)6 etc.) to be unobserved CL due to poor sensitisation with such low concentration of luminol which makes the method hold high selectivity. Based on this observation, the detection limits were 6.5?×?10?9?mol?L?1 and 1.1?×?10?8?mol?L?1 hydrogen peroxide for the DPN- and DPA-luminol CL systems, respectively. The relative CL intensity was linear with the hydrogen peroxide concentration in the range of 2.0?×?10?8–6.0?×?10?6?mol?L?1 and 4.0?×?10?8–4.0?×?10?6?mol?L?1 for the DPN- and DPA-luminol CL systems, respectively. The proposed method had good reproducibility with a relative standard deviation of 3.4% (8.0?×?10?7?mol?L?1, n?=?7) and 1.0% (2.0?×?10?6?mol?L?1, n?=?7) for the DPN- and DPA-luminol CL systems, respectively. A satisfactory result has been gained for the determination of H2O2 in rainwater and artificial lake water by use of the proposed method.  相似文献   

7.
A novel flow injection chemiluminescence (FI‐CL) method for the determination of genistein was described. The method was based on the reaction between genistein and potassium ferricyanide in alkaline solution to give weak CL signal, which was dramatically enhanced by rhodamine 6G (Rh G). The CL emission allowed quantitation of genistein concentration in the range 1.0 × 10?7–4.0 × 10?5 mol/L with a detection limit (3σ) of 4.2 × 10?8 mol/L. The relative standard deviation for 11 parallel measurements of 5.0 × 10?7 mol/L, 4.0 × 10?6 mol/L and 1.0 × 10?5 mol/L genistein were 2.59%, 2.40% and 1.48%, respectively. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. The method was applied to the determination of genistein in biological fluids.  相似文献   

8.
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol‐AgNO3‐Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. The UV‐vis absorption spectrum and CL emission spectrum were applied to confirm the mechanism. The method is simple, rapid and sensitive with a detection limit of 5×10?10 g·mL?1 and a linear range of 8.0×10?10–1.0×10?7 g·mL?1. The relative standard deviation (RSD) is 1.3% for eleven measurements of 5×10?8 g·mL?1 gallic acid. The method has been successfully applied to the determination of gallic acid in Chinese proprietary medicine–Jianmin Yanhou tablets and synthesized samples.  相似文献   

9.
 A rapid flow-injection method with chemiluminescence (CL) detection is described for the determination of glutathione (GSH). The method is based on the CL reaction of luminol and hydrogen peroxide. GSH can greatly enhance the chemiluminescence intensity in 0.1 mol/L borax–sodium hydroxide buffer solution (pH = 9.7). The maximum CL intensity was directly proportional to the concentration of GSH in the range 3.0 × 10−7–2.0 × 10−5 mol/L, and the detection limit was 6.8 × 10−8 mol/L. The relative standard deviation was 3.4% for 5.0 × 10−6 mol/L of GSH (n = 11). Received October 23, 2001; accepted June 18, 2002  相似文献   

10.
《Analytical letters》2012,45(15):3285-3302
ABSTRACT

A sensitive chemiluminescence (CL) induced by light for the determination of riboflavin with flow injection analysis is developed. Riboflavin shows a strong enhancement effect on the CL reaction of luminol oxidized by periodate after the photochemical reaction of riboflavin in alkaline solution, and the enhancing effect of riboflavin disappears under dark conditions. Oxygen can further improve the enhancing effect of the riboflavin in this CL system, and the effects were also investigated. And based on this phenomenon, a very sensitive method of various surfactants, β-cyclodextrin and organic solvents on this CL system for the determination of riboflavin was described. The range of the linear response for riboflavin using this method is ca. 2.4×10?8 ~ 1.0 × 10?6 mol/L, and the detection limit (S/N = 3) is l.0×10?8 mol/L. The applicability of the method was demonstrated by the determination of riboflavin in pharmaceutical preparation.  相似文献   

11.
《Analytical letters》2012,45(16):3148-3157
Abstract

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow‐cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III).

The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2–210 µmol l?1 H2O2 with a LD of 1.8 µmol l?1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10?5 mol l?1 and 6.8×10?5 mol l?1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 µg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved.  相似文献   

12.
The chemiluminescence (CL) detection for the determination of sulfite using the reaction of Ru(bipy)3 2+(bipy=2,2′-bipyridyl)-SO3 2–-KIO4 is described. The concentration of sulfite is proportional to the CL intensity from 1.0 × 10–7 to 1.0 × 10–4 mol/L. The limit of detection is 2.0 × 10–8 mol/L and the relative standard deviation is 4.4% for a 2 × 10–5 mol/L sulfite solution (n = 9). This method has successfully been applied to the determination of sulfite in powdered sugar (sucrose) and of sulfur dioxide in air by using triethanolamine (TEA) as absorbent material.  相似文献   

13.
A novel chemiluminescence (CL) flow system has been developed for the sequential determination of Fe(II) and Fe(III) in water. Fe(II) was detected by its catalytic effect on the CL reaction between luminol immobilized on an anion exchange resin column and dissolved oxygen; Fe(III) was determined by difference measurement after on-line conversion to Fe(II) in a reducing mini-column packed with Cu plated Zn granules. For both ions, the calibration graph was linear in the range 1 × 10–9 to 1 × 10–6 g/mL, and the detection limit was 4 × 10–10 g/mL. A complete analysis could be performed in 1.5 min with a relative standard deviation of less than 5%. The system could be reused for over 200 times and has been applied successfully to the determination of Fe(II) and Fe(III) in natural water samples. Received: 13 March 1997 / Revised: 3 June 1997 / Accepted: 6 June 1997  相似文献   

14.
儿茶酚胺是一类非常重要的神经递质,在人体的心血管系统、神经系统、内分泌腺、肾脏、平滑肌等组织系统的生理活动中起着广泛的调节作用。肾上腺素为儿茶酚胺的一种,建立灵敏、高效的肾上腺素检测技术具有重要的临床意义。本文将银(Ⅲ)配合物与鲁米诺组成新的流动注射化学发光体系,利用碱性介质中肾上腺素对三价银配合物-鲁米诺化学发光体系有明显的增强效应来测定肾上腺素的含量,并据此建立了高效测定肾上腺素的流动注射化学发光新方法。在优化的条件下,该方法测定肾上腺素的线型范围为1.0×10-9~1.0×10-7 mol L-1,检出限为8.0×10-10 mol L-1,对1.5×10-8 mol L-1肾上腺素11次平行测定,其相对标偏差为2.9%。利用建立的分析方法测定了药物肾上腺素,并对三价银-鲁米诺化学发光新体系测定肾上腺素的反应机理进行了讨论。  相似文献   

15.
A sensitive method based on gold nanoparticle‐enhanced CE‐chemiluminescence (CL) detection was developed for quantifying uric acid (UA) in serum. In this work, gold nanoparticles were added into the running buffer of CE to catalyze the post‐column CL reaction between luminol and hydrogen peroxide, achieving highly efficient CL emission. Negative peaks were produced due to the inhibitory effects on CL emission from UA eluted from the electrophoretic capillary. The decrease in CL intensity was proportional to the concentration of UA in the range of 2.5×10?7–1.0×10?5 M. Detection limit was 4.6×10?8 M UA. Ten human serum samples were analyzed by the presented method. Serum level of UA was found to be in the range from 204 to 324 μM for healthy subjects (n=5), and from 464 to 497 μM for diabetic patients (n=5). The two groups were significantly different (p<0.05). The results suggested a potential application of the proposed assay in rapid primary diagnosis of diseases such as diabetes.  相似文献   

16.
A highly sensitive automated sequential‐injection chemiluminescence (SIA‐CL) method for determination of glucosamine sulphate (GLS) was developed. The goal of the present work is the evaluation of the enhancement effect of the investigated drug glucosamine sulphate on the chemiluminescence reaction between luminol and H2O2 in alkaline medium of 1.0 × 10?2 mol L?1 sodium hydroxide at pH 11. The experimental conditions affecting the CL reaction such as the sequence of the reagents, concentrations, flow rate and aspirated volumes of reactants were systematically investigated and optimized. Under optimum conditions 50 μL of 1.0 × 10?3 mol L?1 luminol, 30 μL of a GLS test solution and 50 μL of 1.0 × 10?2 mol L?1 H2O2 were used and the luminescing zone was pushed into the detector at a flow rate 100 μL s?1. The proposed method recorded high sensitivity, accuracy and simplicity that could be clarified as linear concentration range 1.0‐2000 ng mL?1 with rectilinear part (r = 0.9992, n = 9) and limit of detection 0.3 ng mL?1, along with relative standard deviation 1.3%. It was found that the developed method can be used directly to determine the investigated drug GLS in its pharmaceutical dosage forms and in spiked serum and urine by diluting the samples for a 1000 fold. The obtained results were statistically analyzed and compared with those obtained by the reported method.  相似文献   

17.
《Analytical letters》2012,45(14):2026-2036
A novel chemiluminescence (CL) system was established for the determination of diammonium glycyrrhizinate (DG) in pharmaceutical preparations and its ability of scavenging hydroxyl radical. It was shown that a strong CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when DG was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with DG concentration. Based on this, we developed a new method for the determination of DG using a flow injection chemiluminescence (FI-CL) technique. Under the optimal conditions, the linear range of DG concentration was 6.0 × 10?8–5.0 × 10?6 mol/L (R = 0.9982) with a detection limit of 8.0 × 10?9 mol/L (SN = 3), and the RSD was 3.8% for 2.0 × 10?7 mol/L DG (n = 11). This method was successfully used in the determination of DG in tablets and the evaluation of hydroxyl radical scavenging capacity of DG. The possible reaction mechanism of the CL system is discussed.  相似文献   

18.
A new strategy for trace analysis was proposed by preparing a molecularly imprinted polymer (MIP) sensor. The template molecules of clopyralid were determined based on “gate-controlled” electrochemiluminescence (ECL) measurement. A dense polymer film was electropolymerized on an electrode surface to fabricate the MIP–ECL sensor. The process of template elution and rebinding acted as a gate to control the flux of probes, which pass through the cavities and react on the electrode surface. ECL measurement was conducted in the luminol–H2O2 system. A linear relationship between ECL intensity and clopyralid concentrations in the range of 1?×?10?9 mol/L to 8?×?10?7 mol/L exists, and the detection limit was 3.7?×?10?10 mol/L. The prepared sensor was used to detect clopyralid in vegetables. Recoveries of 97.9 % to 102.9 % were obtained. The sensor showed highly selective recognition, high sensitivity, good stability, and reproducibility for clopyralid detection.  相似文献   

19.
流动注射化学发光植物组织传感器测定草酸盐   总被引:3,自引:0,他引:3  
草酸是尿道结石主要成因之一 .统计结果表明 ,90 %以上结石均含草酸钙 .回肠病、口角性肠胃炎及脂肪吸收不良均可引起尿液中草酸的增加 .草酸盐的测定在临床上具有重要意义 .微量草酸测定的传统方法是变色酸比色法或偶氮化合物比色法[1 ] .测定草酸盐的方法还有原子吸收光谱法[2 ] 、高效液相色谱法[3] 、离子色谱法[4] 、光度法[5] 和草酸氧化酶法[6] 等 .这些方法或操作复杂、耗时 ,或灵敏度低 ,使其应用受到限制 .本文提出一种测定草酸盐的新方法 ,其原理为草酸 +O2草酸氧化酶 CO2 +H2 O2 ,Luminol+H2 O2 hv  将含有草…  相似文献   

20.
Tryptophan is an important amino acid for humans with a significant role in cell metabolism. Depletion of tryptophan in the human body may contribute to diseases and development of disorders among the human population. It is, therefore, very important to have a reliable, stable, sustainable, and cost-effective analytical method for the determination of tryptophan. Tryptophan was determined using sequential injection–zone fluidics analysis with luminol–hydrogen peroxide and the Firefly with its unique liquid core waveguide flow-cell design as chemiluminescence tubular reactor with a high-sensitivity photomultiplier tube. This was based on an intense chemiluminescence formation of tryptophan in luminol–hydrogen peroxide inside the tubular reactor for measurement. The chemiluminescence intensity was linear with tryptophan in the range of 1.0?×?10?6 to 1.0?×?10?3?mol/L, and the limit of detection was 7.5?×?10?7?mol/L. The precision for the method was 3.6% (relative standard deviation) for six measurements of 1.0?×?10?4?mol/L tryptophan. The proposed method has been used to determine tryptophan in pharmaceutical formulations. The system is relatively fast for online assays. Eighty seconds are required to complete one cycle providing a throughput of 45 samples/h. The proposed sequential injection analysis–zone fluidics–chemiluminescence system for the assay of tryptophan in certain specific pharmaceutical capsules is simple, reliable, sustainable, and convenient with relatively low-cost consumption of reagents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号