首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine. Calibration curves resulting from spiked blank kidney samples at the 10-200 microg/kg level showed good linear correlation. At the level of 50, 100 and 200 microg/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 microg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

2.
A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the determination of bromobuterol, cimaterol, clenbuterol, clenpenterol, hydroxymethylclenbuterol, isoxsuprine, mabuterol, ractopamine, ritrodrine, salbutamol, terbutaline, and tulobuterol residues in bovine liver and retina is reported. This procedure uses enzymatic digestion, liquid-liquid extraction, and cleanup on Oasis HLB solid-phase extraction cartridges, followed by determination of the residues by LC-tandem quadrupole MS using atmospheric pressure chemical ionization in the positive ion mode. Overall average recoveries ranged from 23 to 76% for liver and 34 to 77% for retina. The mean values for samples fortified at levels between 0.5-2.0 microg/kg (liver) and 5-20 microg/kg (retina) agreed within 98-118% of the spiked levels, with coefficients of variation ranging from 6 to 20%. The decision limits, CCalpha, ranged from 0.1 to 0.3 microg/kg for liver, 1-3 microg/kg for retina, and detection capabilities, CCbeta, from 0.2-0.5 microg/kg for liver and 2-5 microg/kg for retina.  相似文献   

3.
A method is described for the determination of 16 sulfonamides in honey. Samples are dissolved in phosphoric acid solution (pH2), cleaned up with 2 solid-phase extraction (SPE) cartridges, an aromatic sulfonic cation-exchange cartridge and an Oasis HLB SPE cartridge, and analyzed both qualitatively and quantitatively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) under the selected conditions. Without exception, calibration curves were linear (r = > 0.995), when sulfamethizole was between 1.0 and 25.0 microg/kg; sulfacetamide, sulfapyridine, sulfadiazine, sulfachloropyridazine, sulfamethoxazole, sulfamerazine, sulfisoxazole, sulfamonomethoxine, and sulfadoxine were between 2.0 and 50.0 microg/kg; sulfamethoxypyridazine, sulfadimethoxine, and sulfathiazole were between 4.0 and 100.0 microg/kg; sulfamethazine and sulfameter were between 8.0 and 200.0 microg/kg; and sulfaphenazole was between 12.0 and 300.0 microg/kg. Average recoveries at 4 fortification levels in the range of 1.0-300 microg/kg in honey were 70.9-102.5%, and relative standard deviations were 2.02-11.52%. The limits of quantitation for the 16 sulfonamides were between 1.0 and 12.0 microg/kg, with the LC/MS/MS method.  相似文献   

4.
A multi-screening approach for monitoring potential chemical contaminants in honey by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) has been developed. A total of 42 veterinary drugs (5 tetracyclines, 7 macrolides, 3 aminoglycosides, 8 beta-lactams, 2 amphenicols and 17 sulfonamides) were surveyed with the ultimate goal of unambiguously confirmed and quantified these analytes at a concentration level of 20 microg/kg. A basic sample preparation including four subsequent liquid/liquid extraction steps was necessary to adequately extract the compounds of interest from the honey. The four extracts were injected into the LC-ESI-MS/MS using a stacking injection procedure. Validation of the entire procedure was carried out according to the European Union directive 2002/657/EC at three concentration levels, i.e., 10, 20 and 30 microg/kg. Good performance data were obtained for 37 analytes, out of the 42 studied. Limit of compliance and detection limit were calculated based on an internal limit set at 20 microg/kg for all the compounds and ranged between 24-30 and 27-80 microg/kg, respectively. A limited survey on honeys of different geographical origins has demonstrated that positive honey samples were often contaminated by more than one class of drugs, thus highlighting the usefulness of such multi-screening approach to ensure and warrants the quality of honey.  相似文献   

5.
A multi-residue method using pressurized liquid extraction (PLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for determining trace levels of 31 antimicrobials, including beta-lactams, lincosamides, macrolides, quinolones, sulfonamides, tetracyclines, nitroimidazoles and trimethoprim. The extraction method required pre-homogeneization of the meat with EDTA-washed sand and subsequent one-static-cycle extraction for 10 min with 40 ml of water at 1500 psi and 70 degrees C. The effect of operation temperature, pressure, flush volume, and static cycles on PLE performance was studied. Average recoveries ranged from 75 to 99% with relative standard deviations <18%. The method was validated according to the European Union requirements (2002/657/EC). In addition to the quality parameters included in that decision, the limits of detection (LODs) and quantification (LOQs) were determined. The use of LC-MS/MS provided LODs (between 3 and 15 microg kg(-1)) and LOQs (between 10 and 50 microg kg(-1)), by far lower than half of their maximum residue limits (MRLs) (between 50 and 1200 microg kg(-1)). Confirmation of the presence of any of the studied compounds was accomplished in 1h after sample receipt. This methodology has been successfully applied to the analysis of cattle and pig tissue samples from local markets and slaughterhouses of the Valencian Community (Spain). The results showed the presence of some antimicrobials at different concentrations. Quinolones and tetracyclines were the antimicrobials most detected in cattle and pig samples, respectively. Sulfonamides were also frequently detected in both types of samples.  相似文献   

6.
A sensitive liquid chromatograph/tandem mass spectrometric technique (LC/MS/MS) was applied to determine aliphatic and aromatic carbonyl compounds in ambient air. Traces of the carbonyl compounds were sampled by passing through a Sep-Pak DNPH-silica cartridge. Their derivatives were thus eluted with acetonitrile, separated by reversed-phase liquid chromatography and determined by quadrupole tandem mass spectrometry in an atmospheric pressure chemical ionization (APCI) mode with multiple reaction monitoring (MRM). The detection limits (DL) of the carbonyl compounds were 0.8 - 15 ng/m3. A number of the carbonyl compounds were detected at n.d.- 14 microg/m3 levels. The precursor ion scanning analysis was applied to identify the unknown compounds.  相似文献   

7.
A rapid confirmatory liquid chromatographic/tandem mass spectrometic method was developed for determination of chloramphenicol in bovine milk. Chloramphenicol was extracted directly from milk by solid-phase extraction on a C18 cartridge. The extract was further cleaned up on neutral aluminium oxide. Three transition products were monitored in negative ion mode after atmospheric pressure chemical ionization. The detection capability related to the transition product of lowest abundance was 0.03 microg/kg. The mean recovery was 90% at levels of 0.1-0.2 microg/kg. The relative repeatability standard deviations were 4.3, 3.8, and 2.8% at levels of 0.1, 0.2, and 1.0 microg/kg, respectively.  相似文献   

8.
刘培勇  张惠  米之金  张良成  张光仁 《色谱》2019,37(10):1098-1104
建立了猪肉中11种常见的磺胺类兽药残留的两步液液萃取-固相萃取净化-高效液相色谱-串联质谱(LC-MS/MS)检测方法。猪肉样品经乙酸乙酯(含2%(v/v)甲酸)及丙酮分两步液液萃取,正己烷脱脂,Oasis MCX混合阳离子固相萃取小柱净化,氮吹浓缩,定容,过滤膜后进行高效液相色谱-串联质谱分析。采用多反应监测正离子模式进行检测,以基质校准曲线外标法定量。结果表明,在20~400 μg/L范围内11种磺胺类药物均呈现良好的线性关系(相关系数(r2)≥ 0.99),检出限(LODs)(S/N=3)和定量限(LOQs)(S/N=10)分别为0.1~1.0 μg/kg和0.2~3.0 μg/kg。对阴性猪肉样品,在50、100、200 μg/kg 3个水平下分别进行加标回收试验,测得各待测物的平均回收率为79.3%~105.5%之间,相对标准偏差为1.3%~11.6%(n=6)。该方法比采用一步液液萃取法具有更高的提取效率,同时结合固相萃取净化方法进一步富集目标化合物,降低了基质干扰,提高了检测灵敏度。  相似文献   

9.
A rapid method is presented for the determination of 4 nitroimidazoles in poultry and swine muscle and eggs by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Samples were extracted with acetonitrile, then evaporated the organic phase. After filtration, the extract was directly injected into the LC/ESI-MS/MS system. The LC separation was made on a C8 column by applying a gradient composed of water and acetonitrile. Overall average recoveries ranged from 50-86% for egg, 66-115% for poultry muscle, and 79-111% for swine muscle. The decision limits ranged from 0.05-0.25 microg/kg for egg, 0.07-0.27 microg/kg for poultry muscle, and 0.07-0.26 microg/kg for swine muscle; and detection capabilities ranged from 0.51-0.68 microg/kg for egg, 0.41-0.75 microg/kg for poultry muscle, and 0.53-0.78 microg/kg for swine muscle.  相似文献   

10.
Yang X  Li P  Zhao Y  Wu Y 《色谱》2012,30(3):309-313
建立了花生中涕灭威及其代谢物涕灭威砜、涕灭威亚砜的高效液相色谱-线性离子阱三级质谱分析方法。样品经环己烷饱和的乙腈提取,凝胶渗透色谱净化后,用高效液相色谱-线性离子阱三级质谱法对样品中的目标物进行定性确证和定量分析。在Capcell PAK CR色谱柱上以含5 mmol/L NH4Ac-HAc的乙腈为流动相进行梯度洗脱分离。采用电喷雾离子源正离子模式进行三级选择离子监测,以涕灭威-d3作为3个目标物的内标物。通过比较基质匹配曲线和纯溶剂标准曲线计算回收率评估基质效应。方法的线性范围为10~500 μg/L,检出限为4~5 μg/kg。涕灭威、涕灭威砜、涕灭威亚砜在3个加标水平(10、20、40 μg/kg)的回收率为81.5%~115%,相对标准偏差为6.35%~15.1%。应用该方法对花生样品进行了测定,结果令人满意。  相似文献   

11.
A method for the determination of sulfonamides and trimethoprim in the complex matrix liquid manure has been developed using reversed-phase liquid chromatography and atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. A comparison was made between electrospray and atmospheric pressure chemical ionization. APCI proved to be more robust and less sensitive to matrix effects. High-performance liquid chromatographic (HPLC) separation of the analytes was achieved in less than 7 min. The compounds were extracted with ethyl acetate and the extracts were cleaned up by solid-phase extraction on an aminopropyl column. Recoveries were not dependent on the concentration level. The mean recoveries were as follows: trimethoprim 79.0%, sulfadiazine 80.5%, N(4)-acetylsulfadiazine 91.0%, sulfamerazine 78.6%, sulfadimidine 77.2% and sulfamethoxazole 82.8%. Linearity was established over a concentration range of 5 to 5000 microg/kg with correlation coefficients greater than 0.99. The method had a limit of quantitation (LOQ) of 5 microg/kg manure.  相似文献   

12.
Pressurized liquid extraction (PLE) was optimized and validated for the determination of sulfonamide and macrolide antimicrobials and trimethoprim in sewage sludge samples. A mixture of water/methanol (50:50, v/v) was found as the most efficient extraction solvent. A temperature of 100 degrees C and a pressure of 100 bar were chosen for extraction. Two cycles of 5 min each efficiently extracted at least 97% of the total extractable amount of all studied analytes from activated sludge. The limits of quantification (S/N= 10) varied between 3 and 41 microg/kg dry weight (dw) and the relative recoveries ranged between 78 and 142%. Additionally, the influence of pH and different LC/MS/MS systems on the absolute recoveries was assessed. Of the investigated antimicrobials sulfapyridin, sulfamethoxazole, trimethoprim, azithromycin, clarithromycin and roxithromycin were detected in municipal sewage sludge samples. Concentrations in activated sludge ranged up to 197 microg/kgdw. In comparison, results obtained by ultrasonic solvent extraction were significantly lower for sulfonamides and in tendency lower for macrolides.  相似文献   

13.
Hou J  Xie W  Chen X  Xi J  Qian Y  Wang F  Liu H 《色谱》2011,29(6):535-542
建立了采用固相萃取-液相色谱-质谱/质谱(SPE-LC-MS/MS)对蜂蜜中磺胺类、硝基咪唑类、喹诺酮类、大环内酯类、林可酰胺类和吡喹酮共计6大类54种药物残留同时测定的方法。蜂蜜经磷酸盐缓冲溶液(pH 8)稀释,Oasis HLB固相萃取柱净化后,通过液相色谱-质谱联用技术进行检测(正离子方式,多反应监测模式)。采用同位素稀释内标法或外标法进行定量,线性关系良好,相关系数大于0.992。方法的定量限(LOQ,以信噪比(S/N)大于10计)分别为磺胺类和硝基咪唑类药物1.0 μg/kg,喹诺酮类和林可酰胺类药物2.0 μg/kg,大环内酯类药物3.0 μg/kg,吡喹酮0.3 μg/kg。总体回收率为32.6%~114%,相对标准偏差为1.3%~28.9%。该方法的定量限满足目前国内外药物的最大残留限量要求,可作为蜂蜜中相关药物残留量的筛选检测方法。  相似文献   

14.
Liquid chromatography (LC) in combination with tandem mass spectrometry (MS-MS) has been applied to the separation and detection of 10 different sulfonamides in honey. The methodology encompasses a simple hydrolysis of the honey sample to liberate sugar-bound sulfonamides followed by liquid-liquid extraction of the 10 analytes, filtration, and analysis by LC-MS-MS. Conditions for reversed-phase LC and electrospray ionization (ESI) MS-MS in the positive ion mode were optimized for the 10 compounds under study, monitoring two characteristic mass transitions simultaneously for each analyte. The procedure is a qualitative confirmatory method for 10 sulfonamides at the low microg/kg level in honey. Typical recoveries of the analytes in honey ranged from 44 to 73% at a fortification level of 50 microg/kg. This study also addresses the issue of matrix-induced suppression of ionization, an effect often encountered in trace residue analysis of food matrices using LC-ESI-MS-MS based methods.  相似文献   

15.
A quantitative liquid chromatography-electrospray tandem mass spectrometry method for the determination of mebendazole and its hydrolysed and reduced metabolites in sheep liver has been developed and validated. The benzimidazole substances were extracted with ethyl acetate after the sample mixture had been made alkaline. The HPLC separation was performed on a reversed-phase C18 column with gradient elution using a mobile phase consisting of water containing 0.1% formic acid and acetonitrile. The analytes were detected after atmospheric pressure electrospray ionization on a tandem quadrupole mass spectrometer in MS-MS mode. The components were measured by the MS-MS transitions of the molecular ion to the two most abundant daughter ions. The detection limits are lower than 1 microg kg(-1). For this application, the validation limit was set at 50 microg kg(-1). The examined validation parameters were in accordance with the permitted tolerances ranges stipulated in the proposed new European validation criteria for residue surveillance. For the three analytes, the overall recovery was higher than 90%. The RSD for the repeatability ranged from 5 to 11%. The range for the within-laboratory reproducibility was between 2 and 17%. The decision limits for mebendazole, the hydrolysed and the reduced metabolite were 56.6, 61.8 and 64.2 microg kg(-1), respectively. The detection capabilities for these substances were 60.0, 86.1 and 90.9 microg kg(-1), respectively.  相似文献   

16.
A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 microg/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 microg/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 microg/kg.  相似文献   

17.
建立了猪组织中9种β-兴奋剂(克伦特罗、莱克多巴胺、沙丁胺醇、利托君、特布他林、班布特罗、妥布特罗、西马特罗和异舒普林)多残留的液相色谱-四极杆/线性离子阱串联质谱(QTrap LC-MS/MS)检测方法。样品经β-葡萄糖醛苷酶/芳基硫酸酯酶酶解提取,液液萃取净化,以乙腈-甲酸水溶液为流动相,经C18柱分离后用QTrap LC-MS/MS进行多反应监测(MRM)、信息相关采集(IDA)、增强子离子扫描(EPI)和谱库检索分析。9种β-兴奋剂的线性范围为0.1~50.0 μg/L,线性关系良好(r>0.99);样品中9种目标物在0.5、1.0和5.0 μg/kg添加水平下的回收率为72.0%~95.1%,相对标准偏差为3.1%~12.1%;方法检出限为0.1~0.2 μg/kg。实际样品检测结果表明,本方法可实现猪组织样本中β-兴奋剂残留量的灵敏、准确的定性和定量分析。  相似文献   

18.
刘芃岩  姜宁  王英峰  晏利芝 《色谱》2008,26(3):348-352
建立了一种同时测定鸡肉中两类共10种兽药(3种磺胺和7种氟喹诺酮类药物)残留量的高效液相色谱-电喷雾串联质谱方法(HPLC -ESI-MS2)。样品经2%醋酸-乙腈提取,正己烷脱脂,过ENVI-18固相萃取柱净化,经氮气吹干后,残余物用流动相定容到1 mL。以乙腈和 0.05%甲酸溶液作为流动相,采用梯度洗脱程序进行液相色谱分离,用质谱检测器进行定性和定量分析,并对10种药物的二级质谱碎裂方 式进行分析。10种药物在0.02~2.0 mg/L范围内线性良好,相关系数均大于0.9988。检出限(LOD)为1.10~6.85 μg/kg,定量限(LOQ) 为3.68~22.85 μg/kg,样品的平均加标回收率为68.9%~102.6%,相对标准偏差均小于8.6%(n=3)。实验结果表明,该方法灵敏度高,重 现性好,确证能力强,分析时间短,可满足动物源性食品中磺胺和氟喹诺酮类药物的残留分析。  相似文献   

19.
杜振霞  孙姝琦 《色谱》2007,25(5):705-710
建立了鸭蛋黄中苏丹红Ⅰ~Ⅳ号的超高效液相色谱-串联四极杆质谱联用(UPLC-MS/MS)的分析方法。采用乙腈提取样品中的苏丹红,加水反沉淀除去蛋白质和脂肪等杂质,冷冻后高速离心,取上层清液供UPLC-MS/MS分析。经Waters Acquity BHE C18超高效液相色谱柱分离,串联四极杆质谱多反应监测模式检测,4种物质的检出限均为0.05 μg/L,实际样品中4种物质的检出限为10 μg/kg。采用标准添加法测定苏丹红的回收率,100.0,200.0,300.0 μg/kg 3个不同添加水平的回收率为50.2%~101.3%。实验结果表明该方法灵敏度高,检出限低,确证能力强,分析时间短,可满足高通量食品样品中苏丹红的日常检测。  相似文献   

20.
Delhomme O  Millet M  Herckes P 《Talanta》2008,74(4):703-710
In this paper, the development of an analytical method using liquid chromatography-tandem mass spectrometry (LC-MS-MS) with atmospheric pressure chemical ionization (APCI) for the determination of 17 oxygenated polycyclic aromatic hydrocarbons (OPAH) is described. These OPAH include ketones, pyrones and diketones. The APCI interface parameters have been optimized for maximum sensitivity. Positive ion mode was proved to be most sensitive for ketones and pyrones while negative ion mode gave better detection limits for target diketones. The detection limits of the method ranged from less than 1.20microg L(-1) for several OPAH solutions (between 0.10 and 0.70microg L(-1) for positive mode and between of 0.19 and 1.20microg L(-1) for negative mode). The analytical method was applied particulate matter (PM(2.5)) samples collected over 24-48h periods between March 2005 and June 2005 in Tempe (Arizona, USA). Before analysis aerosol samples were solvent extracted and concentrated to a final volume of 1mL of methanol. OPAH concentrations observed for this urban site ranged from 0.22 to 3.60ngm(-3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号