首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Electroanalysis》2005,17(21):1919-1923
We report a reference electrode for direct use in tetrahydrofuran (THF) at low temperatures. A reference solution containing equimolar amounts of ferrocene/ferrocenium hexafluorophosphate (Fc/Fc+) are prepared to give a 4 mM solution in THF that contains tetrabutylammonium hexafluorophosphate (TBAF) supporting electrolyte thus, minimizing liquid junction potentials. The reference solution is added to a sealed glass tube with a porous frit at one end, and a platinum wire is inserted into the tube. The reference electrode assembly is then inserted into a THF test solution. Potentiometric measurements show that the system responds in the expected Nernstian fashion over the concentration and temperature ranges, 4 mM to 40 μM and 20 °C to ?45 °C respectively. In addition, it is shown by steady–state cyclic voltammetry at a platinum microelectrode that the chemical reactivity of ferrocenium hexafluorophosphate (Fc+) otherwise seen in THF is suppressed by ion‐pairing with PF using tetrabutylammonium hexafluorophosphate (TBAF) as the supporting electrolyte.  相似文献   

2.
建立了小麦粉中细交链孢菌酮酸(TeA)和腾毒素(TEN)标准物质的研制和定值方法,为开展粮食中交链孢霉毒素基体标准物质的研制提供重要方法学借鉴。该标准物质样品为天然污染交链孢霉毒素的小麦籽粒,定值目标物为TeA和TEN,采用同位素稀释-液相色谱-串联质谱法(ID-LC-MS/MS)进行定值测量,多个实验室合作定值。所研制的标准物质具有常温避光保存、定值不确定度小等特点。该标准物质是目前国际上唯一一种天然污染TeA和TEN的小麦粉标准物质,可用于食品安全风险监测、产品质量检测等领域相关分析方法的评价和测量质量控制等。  相似文献   

3.
Proficiency testing (PT) results have been used to improve traceability in chemical drinking water analysis. With a generalized least-square regression the mass concentrations of As and Sb were calculated in a drinking water that had been used to prepare proficiency testing samples by a spiking procedure. From the mass concentrations in the matrix and the spiked amounts, reference values with an uncertainty budget could be calculated without the need for reference measurements. The degree to which these reference values can be regarded as traceable is discussed. The results showed slight deviations in some samples between reference values and consensus means.  相似文献   

4.
建立了贻贝中有机氯农药(OCPs)和多氯联苯(PCBs)标准物质的研制和定值方法,该研究对我国开展环境生物标准物质的研制具有重要的方法学借鉴价值。该标准物质样品为采自大连湾海域的贻贝,其定值目标物包括18种OCPs和16种PCBs,采用的定值测量方法是目前世界上最权威、最准确的同位素稀释-高分辨气相色谱/高分辨质谱联用法(ID-HRGC/HRMS)。所研制的标准物质具有定值目标物种类多、不确定度较小(约10%)等特点。该标准物质是目前国际上唯一一种采用同位素稀释高分辨质谱法进行定值的底栖生物中OCPs标准物质,于2012年3月通过了国家一级标准物质的终审,并于2012年6月被国家质量监督检验检疫总局批准为国家一级标准物质(GBW10069)。该标准物质可用于食品安全控制、环境监测、质量检测等领域相关分析方法的评价、测量质量控制及技术仲裁检验等。  相似文献   

5.
Sun G  Ding G 《色谱》2011,29(10):1020-1026
采用毛细管区带电泳法建立了逍遥丸(Xiaoyao Pill, XYP)的毛细管电泳指纹图谱(CEFP)。运用正方形优化法,以色谱指纹图谱分离量指数(RF)为优化的目标函数,对建立指纹图谱的实验条件进行了优化,确定了最佳背景电解质(BGE)溶液50 mmol/L硼砂-50 mmol/L磷酸氢二钠-150 mmol/L磷酸二氢钠-50 mmol/L碳酸氢钠(1:1:1:5, v/v/v/v; pH 7.40)、紫外检测波长228 nm、运行电压12 kV、重力进样25 s (高度14 cm)的分离检测条件。采用未涂层石英毛细管(70 cm×75 μm,有效分离长度57 cm)分离,以咖啡酸色谱峰为参照,确定13批逍遥丸样品的21个共有指纹峰。通过聚类分析确定用其中10批样品生成对照CEFP,以此为标准用系统指纹定量法鉴别13批逍遥丸的质量,结果显示: S3号样品的化学成分数量和分布比例不合格,S10和S12号样品含量明显偏高,其余批次质量均合格。所建立的正方形优化法操作简便,适用于中药的毛细管区带电泳BGE的选择;所建立的逍遥丸CEFP具有较好的精密度和重现性,可以为逍遥丸的质量控制提供新的参考。  相似文献   

6.
Eugenol (4-allyl-2-methoxy-phenol) has been examined as a thermal stabilizer and co-stabilizer for rigid PVC in air, at 180 °C. Its high stabilizing efficiency is detected by its high thermal stability value (Ts) when compared with some of the common reference stabilizers used industrially such as dibasic lead carbonate, calcium-zinc soap and octyl tin mercaptide.Blending this organic stabilizer with some of the reference stabilizers in different ratios had synergistic effect on both the induction period and the dehydrochlorination rate together with the longer extent of discolouration of PVC stabilized by eugenol as compared with the blank and the samples stabilized with reference commercial stabilizers.A probable mechanism for the stabilizing action of eugenol has been proposed. The stabilizing efficiency is attributed partially to the stabilizer's ability to intervene in the radical chain degradation process of PVC and to the replacement of the labile chlorine atoms on PVC chains by a relatively more stable moiety of the organic stabilizer.  相似文献   

7.
用以完全活化空间自洽场(CASSCF)波函数为参考波函数的块相关耦合簇(BCCC)方法(简称CAS-BCCC)研究了烷烃(甲烷和乙烷)中的单键解离过程的势能面(PES). 与其它理论方法比较的结果表明, 该方法可以对所研究的整个解离势能面给出定量准确的描述.  相似文献   

8.
For accurate measurement of concentrations of substances by instrumental analysis, reliable calibration standards are needed. In Japan, national reference materials are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). In JCSS, calibration standards for the analysis of environmental pollutants are supplied. For the traceability to the SI of reference materials for calibration in JCSS, the National Metrology Institute of Japan (NMIJ) is developing high-purity reference materials of volatile organic compounds (VOCs) as NMIJ CRMs. The freezing-point depression method, which has potential as a primary method of measurement, is employed for the determination of property value. In this paper, a development scheme of certified reference materials of high-purity VOCs is described. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

9.
Dalvi AA  Satpati AK  Palrecha MM 《Talanta》2008,75(5):1382-1387
Characteristics of the adsorption/electro-reduction of Pt/Rh hexamethylene tetramine (HMTA) complex on static mercury drop electrode surface were studied. Cyclic voltammetry was carried out to get the insight about the mechanistic behaviour of the catalytic current obtained in the voltammetric scan of Pt/Rh HMTA complex in acidic solution. Adsorptive stripping voltammetry using HMTA as the complexing agent was found to be highly sensitive method for the determination of Pt/Rh. Voltammetric measurements were carried out using hanging mercury drop electrode (HMDE) as the working electrode, a glassy carbon rod as the counter and an Ag/AgCl/KClsaturated as the reference electrode. Various electrochemical parameters like deposition potential, deposition time, concentration of the ligand, supporting electrolyte etc. were optimized. The detection limit of Pt and Rh was found to be 4.38 pML−1 and 2.80 pML−1, respectively for the deposition time of 30 s. Simultaneous determination of Pt(II) and Rh(III) in water samples was possible. The method was found to be free from the commonly occurring interfering ions such as Cu(II), Cd(II), Zn(II), Pb(II), Cr(III), Cr(VI), Fe(III), Fe(II), Ni(II) and Co(II). Spike recovery tests for both Pt and Rh in tap water and sea water samples were also carried out. The method has been verified by analyzing certified reference material (WMG-1).  相似文献   

10.
郭鹤男  杨学东  刘军  郑文凤 《色谱》2012,30(7):690-695
在高效液相色谱-质谱分析指导下,针对性地分离制备了黄芩药材中系列黄酮成分对照品。首先对黄芩药材乙醇提取物进行液相色谱-质谱分析,获得各色谱峰的保留时间、紫外光谱和质谱特征。经波谱数据解析结合文献对比,鉴定了黄芩药材中的19种黄酮类成分。然后根据液相色谱-质谱分析结果和文献,设计了目标成分对照品的制备流程,采用低压制备柱色谱法依次制备了黄芩苷、汉黄芩苷、黄芩素、汉黄芩素和千层纸素A共5种黄酮类成分的对照品。结果表明这5种黄酮类成分对照品的纯度均大于98%。该方法可用于针对性地快速分离制备中药中的化学成分。  相似文献   

11.
胡守刚  郭寅龙  吕龙 《化学学报》2000,58(11):1452-1456
研究了聚乙二醇(PEG)为内标物的电喷雾(ESI)/飞行时间质谱(TOF-MS)准确质量测定方法,并应用于5个红霉类类抗生素质子化分子离子(MH^+)的质量测定。与理论值相比,相对误差均在5×10^-^6以内。PEG可与K^+,Na^+,H^+等形成三种加合离子形式,通过选择适当的实验条件,控制PEG仅以其中的一种加合离子形式出现,这一特点扩大了其应用范围,使之可作为一种普适性的内标物。另外讨论了扫描质量范围、扫描速度等因素对测定结果的影响,并且比较了采用多峰校正法和两峰校正法的结果。结果表明,以PEG为内标的ESI/TOF质谱法可对不稳定碱性化合物的化分子离子(MH^+)进行准确质量测定,而且简便、快速。  相似文献   

12.
This paper describes the history and scheme of reference materials and standard solutions for titrimetry in Japan. Titrimetry is one of the most fundamental and precise methods for determination of a constituent, based on the effective purity of reference materials in stoichiometric analysis. It has wide-ranging applications based on titrimetric reactions such as neutralization, redox, chelatometric, and precipitation titration processes, which are used in various analytical fields all over the world. Japanese Industrial Standards (JIS) have played an important role in establishing a stable supply of reference materials for titrimetry since the 1950s. There are several reports of preparations and their determination, including coulometric studies, in order to establish highly reliable reference materials. This paper briefly reviews the schemes and studies of standardization through the provision of reference materials and standard solutions based on JIS, and several applications in other standards. Presented at Berm-11, October 2007, Tsukuba, Japan.  相似文献   

13.
Two new marine sediment standard reference materials (SRMs), SRM 1941b Organics in Marine Sediment and SRM 1944 New York/New Jersey Waterway Sediment, have been recently issued by the National Institute of Standards and Technology (NIST) for the determination of organic contaminants including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, and chlorinated pesticides. Both sediment SRMs were analyzed using multiple analytical methods including gas chromatography/mass spectrometry (GC/MS) on columns with different selectivity, reversed-phase liquid chromatography with fluorescence detection (for PAHs only), and GC with electron capture detection (for PCBs and pesticides only). SRM 1941b has certified concentrations for 24 PAHs, 29 PCB congeners, and 7 pesticides, and SRM 1944 has certified concentrations for 24 PAHs, 29 PCB congeners, and 4 pesticides. Reference concentrations are also provided for an additional 58 (SRM 1941b) and 39 (SRM 1944) PAHs, PCB congeners, and pesticides. SRM 1944, which was collected from multiple sites within New York/New Jersey coastal waterways, has contaminant concentrations that are generally a factor of 10–20 greater than SRM 1941b, which was collected in the Baltimore (Maryland) harbor. These two SRMs represent the most extensively characterized marine sediment certified reference materials available for the determination of organic contaminants.Electronic Supplementary Material Supplementary material is available in the online version of this article at . A link in the frame on the left on that page takes you directly to the supplementary material.  相似文献   

14.
研制了有机磷阻燃剂磷酸三(2-氯乙基)酯(TCEP)标准物质。采用硅胶柱层析法对TCEP原料进行纯化,得到纯度大于99%的TCEP纯品。通过红外光谱和气相色谱–质谱准确定性分析后,利用气相色谱法和气相色谱–质谱法结合热重分析法分别对TCEP纯物质进行纯度定值。将制备的50 g TCEP纯品分装到100个小瓶中,每瓶0.5g,从中随机选取10瓶,进行均匀性和稳定性实验,结果表明,研制的TCEP标准物质均匀性良好,在半年内是稳定的。研制的有机磷阻燃剂磷酸三(2-氯乙基)酯标准物质的纯度定值为99.56%,扩展不确定度为1.18%(k=2)。研制的磷酸三(2-氯乙基)酯标准物质满足国家二级标准物质标准的要求。  相似文献   

15.
The organic acids present in beer provide important information on the product's quality and history, determining organoleptic properties and being useful indicators of fermentation performance. NMR spectroscopy may be used for rapid quantification of organic acids in beer and different NMR-based methodologies are hereby compared for the six main acids found in beer (acetic, citric, lactic, malic, pyruvic and succinic). The use of partial least squares (PLS) regression enables faster quantification, compared to traditional integration methods, and the performance of PLS models built using different reference methods (capillary electrophoresis (CE), both with direct and indirect UV detection, and enzymatic essays) was investigated. The best multivariate models were obtained using CE/indirect detection and enzymatic essays as reference and their response was compared with NMR integration, either using an internal reference or an electrical reference signal (Electronic REference To access In vivo Concentrations, ERETIC). NMR integration results generally agree with those obtained by PLS, with some overestimation for malic and pyruvic acids, probably due to peak overlap and subsequent integral errors, and an apparent relative underestimation for citric acid. Overall, these results make the PLS-NMR method an interesting choice for organic acid quantification in beer.  相似文献   

16.
合成了一种含双极性9,9-双(9-乙基咔唑-3-基)-4,5-二氮芴(ECAF)配体的新型三羰基铼配合物Re(CO)3(ECAF)Cl,通过核磁共振氢谱及高分辨质谱对其结构进行了确定。以含有4,5-二氮-9,9-螺二芴(SB)配体的铼配合物Re(CO)3(SB)Cl作为参比物,对比研究了其热稳定性及光电性能。结果表明,与参比物的分解温度(366℃)相比,配合物Re(CO)3(ECAF)Cl有极好的热稳定性(热分解温度419℃)。由于富电子咔唑基团导致的能隙增大,相比参比物的发光波长(572 nm),Re(CO)3(ECAF)Cl的发光波长蓝移至565 nm。Re(CO)3(ECAF)Cl的发光量子效率(39%)稍高于参比物(37%)。以旋涂法制成电致发光器件后,基于Re(CO)3(ECAF)Cl器件的最佳掺杂浓度(质量分数)高达30%,是基于参比物器件的2.4倍,而且开启电压低至2.9 V,明显比参比物器件的4.0 V低,说明ECAF配体能有效抑制发光浓度淬灭,且明显改善了铼配合物的载流子传输性能。基于Re(CO)3(ECAF)Cl器件的最大电流效率及最大外量子效率分别为8.2 cd·A^-1和3.0%,低于参比物器件的9.7 cd·A^-1和3.9%。  相似文献   

17.

Cr(III) and/or Cr(VI) determinations based on light emission produced by luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr(III) were studied in order to diagnose and/or avoid method bias. The calibration step was optimized, and the usefulness of the method for speciating chromium was tested. The use of the standard addition method in the linear interval concentration range made it possible to diagnose the accuracy of the method for real samples. Good results were obtained for several real water samples containing chromium at different concentrations. The proposed protocol made the method traceable with an appropriate certified reference material and with the reference method.  相似文献   

18.
土壤中有机氯农药残留分析用标准样品的制备   总被引:1,自引:0,他引:1  
介绍了土壤中有机氯农药残留分析用标准样品的制备方法。土壤样品经风干、研磨、筛分、混匀后装瓶。样品经索氏提取、弗罗里硅土小柱净化后,采用气相色谱-质谱法对残留的有机氯农药进行测定。结果表明,采自沈阳地区的土壤中的有机氯农药含量分布较为均匀,是一种理想的环境标准样品候选物样品。该研究为土壤中有机氯农药残留分析用标准样品的研制奠定了基础。  相似文献   

19.
A new calibration solution reference material for the determination of perfluorooctane sulfonate anion (PFOS) and its salts has been issued as a certified reference material (CRM) by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The purity amount-of-substance fraction of raw material potassium perfluorooctane sulfonate (K-PFOS) was evaluated based on the results obtained using the freezing point depression method, and the purity mass fraction of the raw material was calculated using the average molar mass of impurities, the molar mass of K-PFOS, and the purity amount-of-substance fraction. The certified concentration of this CRM was obtained by multiplying the dilution ratio of the raw material in a prepared solution (methanol) determined from the gravimetric blending method by the purity of the raw material. The preparation concentration of K-PFOS as a certified value of NMIJ CRM 4220-a was determined to be 9.93?mg?kg?1. In addition, the standard uncertainty of the certified value was evaluated from the purity evaluation as well as from sample inhomogeneity, instability, and preparation variation obtained from LC/MS measurements of different gravimetrically prepared solutions of the NMIJ CRM. Consequently, the expanded uncertainty was estimated to be 0.15?mg?kg?1 with a coverage factor k?=?2 corresponding to the half-width of estimated confidence interval of approximately 95%.  相似文献   

20.
Extraction and determination of hexavalent chromium in soil samples   总被引:3,自引:0,他引:3  
A procedure for the extraction of Cr(VI) from solid soil-like samples was presented in which the complexing properties of diethylenetriaminepentaacetic acid (DTPA) were exploited to extract insoluble compounds of Cr(VI). A concentration of DTPA in an ammonium sulphate/ammonium hydroxide buffer equal to 0.02 mol l−1 was chosen. The conditions of extraction of insoluble Cr(VI) from solid samples were optimised using soil certified reference material spiked with known concentration of insoluble Cr(VI) added as PbCrO4. The extracts were analysed by adsorptive stripping voltammetry. Validation of the proposed procedure of extraction was carried out by analysis of certified reference material (CRM) 545 and comparison of the results obtained using the proposed and other methods of extraction in the course of analysis of natural soil samples.  相似文献   