首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel zone fluidics (ZF) system for the determination of the octanol–water partition coefficient (Pow) of drugs was developed. The ZF system consisted of a syringe pump with a selection valve, a holding column, a silica capillary flow-cell and an in-line spectrophotometer. Exact microliter volumes of solvents (octanol and phosphate buffer saline) and a solution of the drug, sandwiched between air segments, were sequentially loaded into the vertically aligned holding column. Distribution of the drug between the aqueous and octanol phases occurred by the oscillation movement of the syringe pump piston. Phase separation occurred due to the difference in densities. The liquid zones were then pushed into the detection flow cell. In this method, absorbance measurements in only one of the phase (octanol or aqueous) were employed, which together with the volumes of the solvents and pure drug sample, allowed the calculation of the Pow. The developed system was applied to the determination of the Pow of some common drugs. The log (Pow) values agreed well with a batch method (R2 = 0.999) and literature (R2 = 0.997). Standard deviations for intra- and inter-day analyses were both less than 0.1log unit. This ZF system provides a robust and automated method for screening of Pow values in the drug discovery process.  相似文献   

2.
An alternative method for the sensitive determination of several drugs of abuse and some of their metabolites in surface and sewage water samples is proposed. Analytes are concentrated using a solid-phase extraction (SPE) sorbent, converted into the corresponding trimethylsilyl derivatives and selectively determined by gas chromatography (GC) with tandem mass spectrometry (MS/MS) detection. Parameters affecting the performance of extraction, derivatisation and determination steps are systematically investigated. Moreover, the stability of target analytes in sewage water samples is discussed. Under final working conditions, water samples were adjusted at pH 8.5 and concentrated using a 200 mg OASIS HLB SPE cartridge. Analytes were sequentially eluted with ethyl acetate followed by acetone and silylated using N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). The reaction was completed in 60 min at 80 °C and the mixture injected directly in the GC–MS/MS system without further purification. In most cases, analytes presented a poor stability in sewage water samples; however, once they are submitted to the SPE process, cartridges can be stored at −20 °C for at least 3 months without significant degradation and/or inter-conversion reactions of illicit drugs. The proposed method provided recoveries over 74% and LODs between 0.8 and 15 ng/L for river and treated wastewater samples. In the case of raw wastewater slightly worse recoveries, between 63 and 137%, and similar LODs were attained. Analysis of a limited number of waste and surface water samples confirmed the presence of several illicit drugs in the aquatic environment, with the highest levels and frequency corresponding to benzoylecgonine, the main metabolite of cocaine.  相似文献   

3.
Liposome capillary electrokinetic chromatography was used to investigate the interactions between three β-blockers of different hydrophobicity and various liposome solutions. The studied β-blockers comprised alprenolol, propranolol, and carvedilol. The composition of the liposome solutions, containing 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine, 1,2-dioleoyl-sn-glycero-3-phos-phoethanolamine, 1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-l -serine, and cholesterol in various molar ratios, was designed by a response surface methodology-central composite design approach. Subsequently, after conducting the liposome capillary electrokinetic chromatography experiments and determining the retention factors from the electrophoretic mobilities of the compounds, and further calculating the distribution coefficients, an analysis of variance was performed. After extracting the statistical models, optimal operational conditions were obtained based on the developed models. To further investigate the interactions between the β-blockers and the liposomes, nanoplasmonic sensing experiments were carried out on two different liposome systems. The overall results demonstrate the strong influence of cholesterol and 1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-l -serine on the distribution coefficients.  相似文献   

4.
5.
The nano-LC technique is increasingly used for both fast studies on enantiomeric analysis and test beds of novel stationary phases due to the small volumes involved and the short conditioning and analysis times. In this study, the enantioseparation of 10 drugs from different families was carried out by nano-LC, utilizing silica with immobilized amylose tris(3-chloro-5-methylphenylcarbamate) column. The effect on chiral separation caused by the addition of different salts to the mobile phase was evaluated. To simultaneously separate as many enantiomers as possible, the effect of buffer concentration in the mobile phase was studied, and, to increase the sensitivity, a liquid–liquid microextraction based on the use of isoamyl acetate as sustainable extraction solvent was applied to pre-concentrate four chiral drugs from tap and environmental waters, achieving satisfactory recoveries (>70%).  相似文献   

6.
7.
Non-steroidal anti-inflammatory drugs are widely used for treatment of animals. According to Council Directive 96/23/EC, residues of these drugs must be monitored because of the potential risk they pose to the consumers' health. For this reason an LC-MS-MS method was developed for detection of wide range of NSAIDs, including both "acidic" NSAIDs (carprofen, diclofenac, flunixin, meloxicam, phenylbutazone, oxyphenbutazone, tolfenamic acid, mefenamic acid, naproxen, ketoprofen, ibuprofen, firocoxib, rofecoxib, and celecoxib) and "basic" NSAIDs (four metamizole metabolites). Analytes were extracted from milk samples with acetonitrile in the presence of ammonium acetate. One portion of the extract was directly analyzed for the presence of metamizole metabolites; a second portion was cleaned with an amino cartridge. All NSAIDs were separated on a Phenomenex Luna C8(2) column and analyzed by LC-MS-MS in negative (acidic NSAIDs) and positive (metamizole metabolites) ion modes. The method was validated in accordance with the requirements of Commission Decision 2002/657/EC. Within-laboratory reproducibility was in the range 7-28%, and accuracy was in the range 71-116%. The method enabled detection of all the analytes with the expected sensitivity, below the recommended concentrations. The method fulfills the criteria for confirmatory methods and, because of its efficiency, may also be used for screening purposes. The procedure was also successfully verified in the proficiency test organized by EU-RL in 2010. As far as the authors are aware, this is one of the first methods capable of detecting diclofenac residues below the MRL in milk (0.1 μg kg(-1)). An additional advantage is the possibility of simultaneous determination of "acidic" NSAIDs and metamizole metabolites.  相似文献   

8.
A novel direct method has been developed for determination of n-octanol–water partition coefficients by hollow-fiber membrane solvent microextraction (HFMSME) combined with high-performance liquid chromatography (HPLC). The compound of interest is dissolved in water with sonication and a hollow fiber containing octanol inside is placed in the sample solution to perform microextraction. After microextraction the concentrations in both the aqueous and n-octanol phases are analyzed by HPLC with UV detection. The method was evaluated with ten reference compounds and shown to be suitable for determination of the partition coefficients of organic compounds accurately, cheaply, simply, and quickly. Previously unknown n-octanol–water partition coefficients have been obtained for other compounds by use of the hollow-fiber membrane solvent-microextraction technique. Figure Schematic diagram of equipment used for hollow-fiber solvent microextraction. (1) hollow cone-shaped support; (2) aqueous sample; (3) porous hollow-fiber membrane tube (PHFMT); (4) n-octanol phase; (5) sealed end of PHFMT; (6) container (15 mL); (7) stir bar; (8) magnetic stirrer  相似文献   

9.
Five adrenolytic drugs have been analyzed by liquid chromatography–mass spectrometry (LC–MS). Samples were prepared by solid-phase microextraction (SPME) using polypyrrole fibers coated on stainless steel support as an adsorbent for the drugs. Adsorption efficiencies were 95% and were close for all the drugs investigated. Relative standard deviations (RSD), calculated for samples prepared in standard solutions, were in the range 2.5–13%, however RSD values for the drugs in human plasma were 2.5–4.5%. Using LC–MS the limit of detection (LOD) and the limit of quantification (LOQ) were in the ranges 0.11–0.18 and 0.39–0.54 ng mL−1, respectively, for the five drugs.  相似文献   

10.
A high-performance liquid chromatography (LC)–tandem mass spectrometry (MS/MS) method has been developed and validated for the determination of 19 drugs of abuse and metabolites and used in whole blood. The following compounds were included: amphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethamphetamine, methamphetamine, cocaine, benzoylecgonine, morphine, 6-acetylmorphine, codeine, methadone, buprenorphine, norbuprenorphine, ketobemidone, tramadol, O-desmethyltramadol, zaleplone, zolpidem, and zopiclone. The sample pretreatment consisted of solid-phase extraction using mixed-mode columns (Isolute Confirm HCX). Deuterated analogues were used as internal standards for all analytes, except for ketobemidone and O-desmethyltramadol. The analytes were separated by a methanol/ammonium formate gradient using high-performance LC (Agilent HPLC 1100) with a 3 mm × 100 mm Varian Pursuit 3 C18 column, 3-μm particle size, and were quantified by MS/MS (Waters Quattro micro tandem quadrupole mass spectrometer) using multiple reaction monitoring in positive mode. Two transitions were used for all analytes, except for tramadol and O-desmethyltramadol. The run time of the method was 35 min including the equilibration time. For all analytes, responses were linear over the range investigated, with R 2 > 0.99. One-point calibration was found to be adequate by validation, thereby saving analysis of multiple calibrators. The limits of quantification (LOQs) for the analytes ranged from 0.0005 to 0.01 mg/kg. Absolute recoveries of the analytes were from 34 to 97%, except for zaleplone (6%). Both the interday precision and the intraday precision were less than 15% (20% at the LOQ) for all analytes, except buprenorphine, norburprenorphine, and zaleplone (less than 18%). Accuracy (bias) was within ±15% (±20% at the LOQ) for all analytes, except MDMA and O-desmethyltramadol (within ±19%). No ion suppression or enhancement was seen nor was suppression from coeluted analytes seen. Matrix effects were found to be less than 23% for all analytes, except zopiclone (64%). High-concentration and low-concentration quality control samples gave acceptable values, and the method has been tried in international proficiency test schemes with good results. The present LC-MS/MS method provides a simple, specific, and sensitive solution for the quantification of some of the most frequent drugs of abuse and their metabolites in whole blood. The quantification by LC-MS/MS was successfully applied to 412 forensic cases from October 2008 to mid February 2009, where 267 cases were related to zero-tolerance traffic legislation.  相似文献   

11.
In this work,a reliable and sensitive method for detecting polybrominated diphenyl ethers(PBDEs) has been developed by the combination of liquid–liquid extraction and gas chromatography–mass spectrometry.PBDEs were extracted from a large volume of water by liquid–liquid extraction and purified by silica gel chromatography.In order to reduce the deviation,dibromobiphenyl was exploited as the internal standard to minimize differences among the injections.The quantification was performed using an external standard.Good linear correlation coefficients(0.991) and a wide linearity range(1.0–500.0 ng/L) indicated the steadiness of the proposed method.Moreover,the satisfactory recovery(75%)suggested that successful determination of PBDEs in river water had been achieved.Furthermore,the deduction behavior of PBDEs in river water could be inferred according to the results.  相似文献   

12.
A multi-residue method for the analysis of 76 pharmaceutical agents of nine classes of drugs (tetracyclines, macrolides, fluoroquinolones, β-agonists, β-blockers, diuretics, sedatives, sulfonamides and chloramphenicol) in slaughterhouse wastewater and a receiving river is presented. After simultaneous extraction with an Oasis HLB solid-phase extraction (SPE) cartridge and further purification using an amino SPE cartridge, analytes were detected by liquid chromatography–electrospray ionization-tandem mass spectrometry in positive or negative ion mode. Standard addition was used for quantification to overcome unavoidable matrix effects during ESI-MS analysis. Recoveries for most analytes based on matrix-matched calibration in different test matrices were >60%. The method quantification limits of 76 pharmaceuticals were in the range 0.2–30 ng/L. Nineteen compounds of 76 drugs were found in raw and treated slaughterhouse wastewater from four main slaughterhouses in Beijing. Sulfanamides (sulfanilamide, sulfameter), fluoroquenones (ofloxacin, pefloxacin, norfloxacin, ciprofloxacin, enrofloxacin), tetracyclines (tetracycline, oxytetracycline) and macrolides (kitasamycin, tylosin, erythromycin) were most frequently detected, with the highest levels up to ∼3 μg/L in slaughterhouse wastewater and ∼1 μg/L in treated wastewater. Illicit drugs for animal feeding such as clenbuterol and diazepam were commonly detected in slaughterhouse wastewater. These analytes were also observed in a river receiving slaughterhouse wastewater, with a highest level of up to 0.2 μg/L.  相似文献   

13.
A stir membrane liquid phase microextraction procedure working under the three-phase mode is proposed for the first time for the determination of six anti-inflammatory drugs in human urine. The target compounds are isolated and preconcentrated using a special device that integrates the extractant and the stirring element. An alkaline aqueous solution is used as extractant phase while 1-octanol is selected as supported liquid membrane solvent. After the extraction, all the analytes are determined by liquid chromatography (LC) with ultraviolet detection (UV). The analytical method is optimized considering the main involved variables (e.g., pH of donor and acceptor phases, extraction time, stirring rate) and the results indicate that the determination of anti-inflammatory drugs at therapeutic and toxic levels is completely feasible. The limits of detection are in the range from 12.6 (indomethacin) to 30.7 μg/L (naproxen). The repeatability of the method, expressed as relative standard deviation (RSD, n = 5) varies between 3.4% (flurbiprofen) and 5.7% (ketoprofen), while the enrichment factors are in the range from 35.0 (naproxen) to 72.5 (indomethacin).  相似文献   

14.
An optimised extraction and cleanup method for the analysis of pesticide in natural water samples is presented. Sixteen pesticides of different polarity and from the different chemical classes (organophosphates, triazines, benzimidazoles, carbamates, carbamides, neonicotinoides, methylureas, phenylureas and benzohydrazides), most frequently used in Serbia, were selected for the analysis. Liquid-phase microextraction in a single hollow fibre (HF-LPME) has been applied for sample preparation. The concentrations of pesticides were determined using HPLC-MS/MS method with electrospray ionisation. The extraction behaviour and selection of the experimental conditions was predicted based on log D and pK a values of targeted pesticides, which were calculated applying the computer software ACD/Labs PhysChem Suite v12. The influence of the donor pH and concentration of pesticides, organic phase composition as well as the extraction time on the extraction efficiency was investigated. Optimum extraction conditions were evaluated with respect to the investigated parameters of the extraction. The extraction method was validated for 10 out of 16 studied pesticides. Linear range of the pesticides was 0.1–5 μg L−1 with the correlation coefficient from 0.991 to 0.9998, and the relative standard deviation for three standard measurements was between 0.2 and 11.8%. The limits of detections ranged from 0.026 to 0.237 μg L−1 and the limits of quantifications from 0.094 to 0.793 μg L−1. The optimised two-phase HF-LPME method was successfully applied for determination of moderately polar as well low-polar pesticides in the environmental water samples.  相似文献   

15.
A novel microextraction method termed ionic liquid dispersive liquid–liquid microextraction (IL-DLLME) combining high-performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of insecticides in water samples. Four heterocyclic insecticides (fipronil, chlorfenapyr, buprofezin, and hexythiazox) were selected as the model compounds for validating this new method. This technique combines extraction and concentration of the analytes into one step, and the ionic liquid was used instead of a volatile organic solvent as the extraction solvent. Several important parameters influencing the IL-DLLME extraction efficiency such as the volume of extraction solvent, the type and volume of disperser solvent, extraction time, centrifugation time, salt effect as well as acid addition were investigated. Under the optimized conditions, good enrichment factors (209–276) and accepted recoveries (79–110%) were obtained for the extraction of the target analytes in water samples. The calibration curves were linear with correlation coefficient ranged from 0.9947 to 0.9973 in the concentration level of 2–100 μg/L, and the relative standard deviations (RSDs, n = 5) were 4.5–10.7%. The limits of detection for the four insecticides were 0.53–1.28 μg/L at a signal-to-noise ratio (S/N) of 3.  相似文献   

16.
The application of ionic liquids (ILs) as nonderivatizing solvents for the pretreatment and regeneration of cellulose is a growing area of research. Here we report the development of a rapid and simple method for the determination of residual ethanol content in two hydrophilic ILs, 1-butyl-3-methylimidazolium chloride and 1-ethyl-3-methylimidazolium acetate. The method utilizes headspace solid-phase microextraction coupled with gas chromatography at elevated extraction temperatures, resulting in rapid equilibration times. The effect of IL water content on the ethanol extraction efficiency is presented. Recovery experiments carried out in real samples gave recoveries ranging from 96.8 to 98.2%.  相似文献   

17.
A method for the determination of methylmercury (MeHg) fluxes across the air–water and air–soil interfaces was developed using an in situ chamber. The MeHg in the air coming out of the chamber was captured by a column containing sulfhydryl cotton fiber adsorbent. MeHg was then desorbed from the column by using 2 mol L–1 HCl. The MeHg in the effluent was extracted with benzene, and determined by gas chromatography with electron capture detection. Finally, the MeHg flux was calculated using the chamber. The method was applied to simulated experiments, and the results showed that the MeHg fluxes in the air–water system were higher than those in the air–soil–water system. The method was also successfully applied to the field measurements of an environment polluted by a chemical factory, and the results showed that the MeHg fluxes across the air–soil and air–water interfaces were 0.21–3.09 and 0.14–0.79 ng m–2 h–1, respectively. The method will be a useful tool in the environmental study of MeHg.  相似文献   

18.
A novel and efficient analytical methodology is proposed for extracting and preconcentrating polybrominated diphenyl ethers (PBDEs) from samples of environmental interest prior gas chromatography–mass spectrometry (GC–MS) analysis. It is based on the induction of micellar organized medium by using a non-ionic surfactant (Triton X-114) to extract the target PBDEs. To enable coupling the efficient extracting technique with GC analysis, ultrasound-assisted back-extraction (UABE) into an organic solvent was required. Several factors, including surfactant type and concentration, equilibration temperature and time, ionic strength, pH and buffers nature and concentration were studied and optimized over the extraction efficiency of the proposed technique. Under optimal experimental conditions, the target analytes were quantitatively extracted achieving an enrichment factor of 250 when 10 mL aliquot of ultrapure water spiked with PBDE-standard mixture (10 pg mL−1 each PBDE) was extracted. Method detection limits (MDLs) calculated with aqueous PBDEs solutions as three times the signal-to-noise ratio (S/N), ranged from 1 to 2 pg mL−1 with RSDs values ≤8.5% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.9987 and linear range of all PBDEs was 4–150 pg mL−1. The proposed methodology was validated by carrying out a recovery study by spiking the samples at two different concentration levels of PBDEs (10 and 50 pg mL−1 for waters samples). Recoveries values in the range of 96–106% for water samples were obtained showing satisfactory robustness of the method for analyzing PBDEs in water samples. The proposed methodology was applied for the analysis of PBDEs: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153) in water samples, including drinking, lake, river water and soil samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

19.
Water contamination due to the wide variety of pesticides used in agriculture practices is a global environmental pollution problem. Analytical methods with low quantification limits are necessary. The application of a new extraction technique, solvent drop microextraction (SDME), followed by gas chromatography with a nitrogen-phosphorus detector, was assessed for determining carbamates and organophosphorus pesticides in natural water. Experimental parameters which control the performance of SDME such as selection of microextraction solvent, optimization of organic drop volume, effects of sample stirring, salt addition, and, finally, sorption time profiles were studied. Once SDME was optimized, analytical parameters such as linearity (r 2>0.99), precision (<13%), and detection limits (0.2 to 5 μg/L), plus matrix effects were evaluated (no matrix effects were found). SDME is a dynamic technique able to extract pesticides from water in 14 min; the use of organic solvents and water samples for SDME is negligible compared to other extraction techniques.  相似文献   

20.
An LC-MS/MS method using 0.5 ml of oral fluid was developed for the determination of morphine, codeine, 6-monoacetylmorphine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxy-N-ethylamphetamine, benzoylecgonine, cocaine, delta-9-tetrahydrocannabinol, zolpidem, zopiclone, alprazolam, clonazepam, oxazepam, nordiazepam, lorazepam, flunitrazepam, diazepam, diphenhydramine and amitriptyline. The method was fully validated in terms of linearity (the method was linear between 1–5 μg/L and 100–200 μg/L) recoveries (7.5–82.6%), within-day and between-day precisions and accuracies (CV and MRE, both <15%), limits of detection (0.5 μ g/L) and quantitation (the lowest point on the calibration curve), relative ion intensities, freeze-and-thaw stability and matrix effect. The method was applied to preserved oral fluid collected by a special commercial device, the StatSure Saliva Sampler™.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号