首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
In this study, a novel and highly sensitive electrochemical method for simultaneous determination of catechol (CC) and hydroquinone (HQ) was developed, which worked at GCE modified with Nano cobalt (Nano-Co) by electrodeposition and L-Cysteine by electrochemical polymerization. The Nano-Co/L-Cysteine GCE was investigated by cyclic voltammetry (CV), SEM and EIS. The excellent conditions have been selected including supporting electrolyte, pH, accumulation time and scan rate. The calibration curves of were obtained that the linear regression equation was I=0.0734c+6×10−6 in the range of 5.8 μM to 103 μM (R2=0.9942) for CC and the linear regression equation was I=0.0566c+5×10−6 in the range of 5.8 μM to 100 μM (R2=0.9967) for HQ. The obtained detection limits of CC and HQ both were 6×10−7 M. The modified electrode was successfully applied to the simultaneous determination of CC and HQ in water samples.  相似文献   

2.
The simple and effective method for the novel synthesis of Pt-based nanoparticle was presented with high efficiency. The sensitive catalyst for the simultaneous detection of catechol and hydroquinone was prepared by depositing ternary metal complex on fluorine-doped tin-oxide (FTO). The composition and morphology of nanomaterials were characterized by TEM, HRTEM, XRD, XPS, and EDS (energy dispersive spectroscopy). The size of the Pt-based nanomaterial was about 5±1 nm. The electrochemical performance of the modified catalyst was studied by CV, DPV, and EIS. The modified PtNiCu@FTO catalyst possessed good electro-oxidation activity for hydroquinone and catechol and used for simultaneous detection of catechol and hydroquinone at scan rate of 20 mV s−1 (vs. Ag/AgCl). Detection responses were found in the ranges of 5–2900 μM for hydroquinone and 5–3000 μM for catechol. The detection limits (LOD) for HQ and CC were observed as 0.35 and 0.29 μM, respectively. The sensitivity of HQ and CC were 1515.55 and 1485 μA mM−1 cm−2, respectively. The prepared nanomaterial were effectively applied for the determination of CC and HQ in real samples.  相似文献   

3.
A simple and highly selective electrochemical method has been developed for the simultaneous determination of hydroquinone (HQ) and catechol (CC) at a glassy carbon electrode covalently modified with penicillamine (Pen). The electrode is used for the simultaneous electrochemical determination of HQ and CC and shows an excellent electrocatalytical effect on the oxidation of HQ and CC upon cyclic voltammetry in acetate buffer solution of pH 5.0. In differential pulse voltammetric measurements, the modified electrode was able to separate the oxidation peak potentials of HQ and CC present in binary mixtures by about 103 mV although the bare electrode gave a single broad response. The determination limit of HQ in the presence of 0.1 mmol L−1 CC was 1.0 × 10−6 mol L−1, and the determination limit of CC in the presence of 0.1 mmol L−1 HQ was 6.0 × 10−7 mol L−1. The method was applied to the simultaneous determination of HQ and CC in a water sample. It is simple and highly selective.  相似文献   

4.
In this study, for the first time, the electro-polymerization of Direct blue15 (DB15), an azo dye, was carried out on the surface of ITO. Furthermore, the poly(DB15) surface was electrochemically decorated with Ag nanoparticles (AgNPs), and the fabricated AgNPs/PDB15 electrodes were examined as nitrate sensors. Compared to unmodified ITO electrode, the AgNPs/PDB15 electrode had greatly improved electrochemical response to nitrate reduction. The nitrate determination in a linear range from 1.0×10−5 mol L−1 to 2.27×10−3 mol L−1 was performed with a detection limit of 9.66 μM. The synthesized electrode is a promising sensor for the electrochemical detection of nitrate pollutants in water.  相似文献   

5.
The second order voltammetric technique of high resolution, Differential Alternative Pulses Voltammetry (DAPV), was applied for the simultaneous determination of hydroquinone (HQ) and catechol (CC) on bare spectroscopic graphite electrode. Well resolved anodic and cathodic peaks situated on both sides of the zero line were obtained, while the differential pulse voltammograms were overlapped. The linear concentration range for HQ and CC quantification by DAPV was extended up to 20 μmol L−1 for both the isomers. The sensitivity of the determination was found to be 6.00 μA L μmol−1 and 3.61 μA L μmol−1, while the limit of detection reached was 0.2 μmol L−1 and 0.5 μmol L−1 for HQ and CC, respectively. No interference was observed from the commonly coexisting organic species such as resorcinol, phenol and p‐benzoquinone. The great resolution power of DAPV permitted obtaining excellent results without any electrode modification and any mathematical data processing.  相似文献   

6.
A well-established electrode modifier, i. e., carboxylic acid (CA) functionalized-multiwalled carbon nanotubes (f-MWCNT), and a less explored safranin O (SFO) were fabricated on cuboidal graphite electrodes to develop two different voltammetric sensors for norfloxacin‘s electrochemical detection. The developed CA f-MWCNT/graphite electrode and SFO/graphite showed a linear range of 3.10×10−7 to 3.13×10−5 M and 2.50×10−8 to 4.06×10−7 M with a limit of detection of 1.60×10−8 and 4.80×10−9 M, respectively. The practical applicability was tested in the spiked hospital wastewater, milk, and orange juice. It showed that the SFO could be a potential modifier for rapid, simple, and sensitive voltammetric detection of norfloxacin.  相似文献   

7.
An electrochemical oxidation of acetaminophen (ACOP) has been successfully performed by using glassy carbon electrode covered with 4-hydroxyquinoline-3-carboxylic acid (4HQ3CA) to reinforce electrode's feature. To characterize the modified electrode (4HQ3CA/GC), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FT-IR) techniques were used. The finding optimum conditions (supporting electrolyte, pH) and the electrochemical determination studies were performed with differential pulse voltammetry (DPV). It was decided that the supporting electrolyte medium suitable for ACOP determination was Britton-Robinson (BR) buffer and the effect of pH change on the oxidation peak of ACOP in this media was investigated. The effect of changing scan rate on the oxidation peak of ACOP was examined and this study showed that the oxidation process of ACOP on the 4HQ3CA/GC modified electrode surface was diffusion and adsorption controlled process. A wide concentration range from 0.0025 μM to 141 μM with a limit of detection (LOD) of 5.98×10−10 M (3 s/m) was obtained. This prepared sensor was carried out for the determination of ACOP in pharmaceutical sample.  相似文献   

8.
We report a method for the fabrication of glassy carbon electrode modified porous graphene-polypyrrole-polyphenol oxidase (GCE−PG−PPy−PPO) modified electrode for the determination dopamine. The optimization of pH, concentration and detection limit of dopamine was employed by amperomatric technique. The detection limit of dopamine was found to be in a linear range of 2×10−8 to 4.6×10−5 M and lower limit detection is 4×10−9 M. Michealis – Menten constant (Km) and the activation energy were calculated as 31.32 μM and 37.4−Kj mol−1, respectively. The developed biosensor was used to quantify the dopamine in human urine sample.  相似文献   

9.
《Electroanalysis》2017,29(4):1141-1146
A novel and sensitive voltammetric method was proposed for separation and determination of glutathione (GSH) and L‐tyrosine (Tyr) at acetylene black and chitosan modified glassy carbon electrode (AB‐CS/GCE). By introducing chlorogenic acid (CGA) as a new electrocatalytic mediator, GSH could be detected at much lower potential with symmetric peak shape. Acetylene black and chitosan composite served as current signal amplifier for sensitive detection. The electrochemical behavior of GSH and Tyr in the presence of CGA was studied at AB‐CS/GCE and complete separation of anodic peaks was achieved. Under the optimum conditions, the electrocatalytic oxidation peak current of GSH showed a linear dependence on its concentration in the ranges of 2.0×10−7‐4.0×10−5 M with the detection limit of 5.8×10−8 M (S/N=3), while the oxidation peak current of Tyr was linear to its concentration from 2.5×10−6 to 4.3×10−4 M with the detection limit of 9.2×10−7 M (S/N=3) by differential pulse voltammetry (DPV). The established method has been applied to the simultaneous determination of GSH and Tyr in human urine with satisfactory results.  相似文献   

10.
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with −81.7 ± 1.7 (r2 = 0.9986) and −146.2 ± 2.3 mV/decade (r2 = 0.9991) slopes over the linearity range 1.5 μM–1.5 mM with 0.8 and 1.0 μM detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)6]−3/−4 redox-active electrolyte. Sensors achieved detection limits of 4.3 × 10−8 and 1.8 × 10−7 M over the linear ranges of 5.2×10−8–1.0×10−4 M and 1.4×10−6–1.4×10−3 M, with 0.09 ± 0.004 and 0.168 ± 0.009 log Ω/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.  相似文献   

11.
Bovine serum albumin (BSA) was covalently attached to glassy carbon electrode (GCE) surface by the electrochemical method. An enhancement for the redox of hydroquinone (HQ) on BSA/GCE was confirmed by cyclic voltammetry and electrochemical impedance spectroscopy measurement. The electron transfer rate constant (k s) on the BSA/GCE electrode is almost three orders of magnitude higher than that on bare GCE. The enhancing effect can be attributed to the electrostatic force between the positively charged HQ and negatively charged BSA. It is found that the enhanced redox process of HQ can be used to determine HQ sensitively. The oxidation current can reach 95% of its steady-state value within 30 s. The linear range for HQ determination is from 2.5 × 10?8 M to 1.325 × 10?6 M with a detection limit of 8.6 × 10?9 M at a signal-to-noise ratio of 3. The study may provide a simple, rapid and sensitive method for determination of HQ which is present in the natural environment and in chemical industry effluent.  相似文献   

12.
The development of sensitive, fast and efficient nanointerfaces as platforms for electrochemical sensing devices for the detection of environmental pollutant including antibiotic pollutant has become a matter of priority for public safety. We report herein a benzene sourced graphene-gold nanoparticle sensor for the detection of tetracycline using chronoamperometry. Structural analysis using Raman Spectroscopy and x-ray diffraction spectroscopy (XRD) confirmed the presense of few-layer graphene. Atomic force (AFM) and scanning electron microscopy (SEM) characterization results confirmed the synthesized graphene to be thin flat sheet-like material with wide surface area and a thickness of less than 1 nm. Cyclic voltammetry characterization of the fabricated modified electrodes showed diffusion controlled process for the oxidation of tetracycline. The modified electrode exhibited a fast response to the detection of tetracycline and a sensitivity of 1,86×102 μA/mM/cm2.The theoretical detection limit (S/N=3) was 1,60×10−1 μM and the linear dynamic range was from 2,90×101 μM to 1.53×103 μM.  相似文献   

13.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

14.
A very effective electrochemical sensor for the analysis of propranolol was constructed using TiO2/MWCNT film deposited on the pencil graphite electrode as modifier. The modified electrode represented excellent electrochemical properties such as fast response, high sensitivity and low detection limit. The proposed sensor showed an excellent selective response to propranolol in the presence of foreign species and other drugs. The electrochemical features of the modified electrode were investigated by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) technique which indicated a decrease in resistance of the modified electrode versus bare PGE and MWCNT/PGE. The surface morphology for the modified electrode was determined by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT-IR). Differential pulse technique (DPV) was used to determine propranolol which showed a good analytical response in the linear range of 8.5×10−8-6.5×10−6 M with a limit of detection 2.1×10−8 M. The TiO2/MWCNT/PGE sensor was conveniently applied for the measurement of propranolol in biological and pharmaceutical media.  相似文献   

15.
In this work, we present a simple and efficient method for preparation of widely dispersed PtNiCo nanocatalyst on FTO without the use of any heavy complex structure. The proposed nanocatalyst enhances the chemical interaction of PtNiCo/FTO and increases its catalytic activity, which was used for electrochemical sensing of catechol and hydroquinone. The surface morphology was characterized by TEM, HRTEM, and XRD. The size of the PtNiCo/FTO octahedrons nanocatalyst was about 0.35–4 nm. Gradual increase of concentration exhibited linearity in oxidation peak response up to 1100 μM with a low detection limit of 0.79 μM for HQ and 1.05 μM for CC. The sensitivity is 1035 μAmM−1 cm−2 for catechol and 1197 μAmM−1 cm−2 for hydroquinone. The prepared nanomaterial/sensor applied to real water samples with good reproducibility (98–99 %).  相似文献   

16.
A novel solid-state electrochemical sensor based on a newly synthesized cross-linked copper(II) doped-copolymer and carbon nanotube material was developed for the direct determination of monohydrogen phosphate ions (HPO42−). The synthesized copolymers were characterized by FTIR, XPS, TG/DTG-DTA and SEM techniques. The sensor had a Nernstian slope:-30.7±0.4 mV/decade, linear concentrations range: 1.0×10−6 - 1.0×10−1 M, detection limit: 6.5×10−7 M, response time: 4 s and life time: 17 weeks. The sensor displayed constant potentials in the pH range 7.0-9.5. The sensor was successfully used as an indicator electrode in potentiometric titration and the direct determination of HPO4 2− in water samples.  相似文献   

17.
The mixed‐valent nickel hexacyanoferrate (NiHCF) and poly(3,4‐ethylenedioxythiophene) (PEDOT) hybrid film (NiHCF‐PEDOT) was prepared on a glassy carbon electrode (GCE) by multiple scan cyclic voltammetry. The films were characterized using atomic force microscopy, field emission scanning electron microscopy, energy dispersive spectroscopy, X‐ray diffraction, and electrochemical impedance spectroscopy (AC impedance). The advantages of these films were demonstrated for the detection of ascorbic acid (AA) using cyclic voltammetry and amperometric techniques. The electrocatalytic oxidation of AA at different electrode surfaces, such as the bare GCE, the NiHCF/GCE, and the NiHCF‐PEDOT/GCE modified electrodes, was determined in phosphate buffer solution (pH 7). The AA electrochemical sensor exhibited a linear response from 5×10−6 to 1.5×10−4 M (R2=0.9973) and from 1.55×10−4 to 3×10−4 M (R2=0.9983), detection limit=1×10−6 M, with a fast response time (3 s) for AA determination. In addition, the NiHCF‐PEDOT/GCE was advantageous in terms of its simple preparation, specificity, stability and reproducibility.  相似文献   

18.
《Electroanalysis》2018,30(5):910-920
A label‐free DNA biosensor based on magnetite/multiwalled carbon nanotubes/chitosan (Fe3O4/MWCNTs‐COOH/CS) nanomaterial for detection of Bacillus cereus DNA sequences was fabricated. Negatively charged DNA was electrostatically adsorbed onto materials by protonation of positively charged chitosan under acidic conditions. The electrode surface and hybridization process were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimal conditions, the biosensor showed a good linear relationship between peak currents difference (ΔI) and logarithm of the target DNA concentration (Log C) ranging from 2.0×10−13 to 2.0×10−6 M with a detection limit of 2.0×10−15 M (signal/noise ratio of 3). The biosensor also revealed an excellent selectivity to three‐base, completely mismatched and completely matched DNA. This is a simple, fast and friendly method with a low detection limit for the detection of Bacillus cereus specific DNA compared with previously reported electrochemical DNA biosensor. Furthermore, the DNA biosensor may lead to the development of a technology for gold prospecting in the wild.  相似文献   

19.
In this work, we reported the development of a nickel metal-organic framework nanosheet array on Ti-mesh (Ni-MOF/TM) as an enzyme-free electrochemical sensing platform for H2O2 determination. The as-obtained sensor exhibited outstanding detection properties of H2O2, which might be gifted from the large specific surface area, abundant active sites of Ni-MOF nanoarrays. The sensor displayed a good linear range (0.8 μM–4.6×103 μM), a detection limit as low as 0.26 μM, a high sensitivity (307.5 μA mM−1 cm−2), and a rapid response. Moreover, this enzyme-free sensor is promising for point-of-care (POC) testing of H2O2 in human serum attribute to the excellent performance of Ni-MOF and the simple preparation process of the sensor.  相似文献   

20.
《中国化学会会志》2018,65(6):743-749
A glassy carbon electrode (GCE) modified with a copper‐based metal‐organic framework (MOF) [HKUST‐1, HKUST‐1 = Cu3(BTC)2 (BTC = 1,3,5‐benzenetricarboxylicacid)] was developed as a highly sensitive and simple electrochemical sensor for the determination of dopamine (DA). The MOF was prepared by a hydrothermal process, and the morphology and crystal phase of the MOF were characterized by scanning electron microscopy (SEM) and X‐ray diffraction (XRD), respectively. Meanwhile, the electrochemical performance was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the modified electrode showed excellent electrocatalytic activity and high selectivity toward DA. The linear response range was from 5.0 × 10−7 to 1.0 × 10−4 M and the detection limit was as low as 1.5 × 10−7 M. Moreover, the electrochemical sensor was used to detect DA in real samples with excellent results. MOF‐based sensors hold great promise for routine sensing applications in the field of electrochemical sensing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号