首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
The expression of gangliosides in central nervous system is a few times higher than in the extraneural tissue, a characteristic highlighting their major role at this level. Although in very low amounts, gangliosides are ubiquitously distributed in body fluids too, where, depending on many factors, including pathological states, their composition fluctuates, thus having diagnostic value. Ganglioside investigation in biological fluids, which, except for cerebrospinal fluid (CSF), may be sampled noninvasively, was for years impeded by the limited sensitivity of the analytical instrumentation available in glycomics. However, because the last decade has witnessed significant developments in biological mass spectrometry (MS) and the hyphenated separation techniques, marked by a major increase in sensitivity, reproducibility, and data reliability, ganglioside research started to be focused on biofluid analysis by separation techniques coupled to MS. In this context, our review presents the achievements in this emerging field of gangliosidomics, with a particular emphasis on modern liquid chromatography (LC), thin-layer chromatography, hydrophilic interaction LC, and ion mobility separation coupled to high-performance MS, as well as the results generated by these systems and allied experimental procedures in profiling and structural analysis of gangliosides in healthy or diseased body fluids, such as CSF, plasma/serum, and milk.  相似文献   

2.
Sisu E  Flangea C  Serb A  Rizzi A  Zamfir AD 《Electrophoresis》2011,32(13):1591-1609
Gangliosides, sialic-acid-containing glycosphingolipids are involved in numerous biological processes and play essential roles in severe pathologies, with predilection in those of the central nervous system. Formerly, ganglioside composition and quantity were assessed exclusively by thin-layer chromatographic (TLC), immunochemical, and immunohistochemical methods, which have limited effectiveness being unable to detect minor components in mixtures of high heterogeneity. Increased awareness of the biological importance of gangliosides stimulated the development of analytical methods that are better amenable to complex ganglioside mixtures. More recently, MS in online conjunction with high-performance separation techniques brought a significant progress to the field. This review highlights the state-of-the-art development and application of separation methods online coupled to MS for ganglioside analysis. Most original and successful protocols based on GC-MS, LC-MS, and CE-MS are presented here together with the special instrumental and sample preparation requirements to be met for effective ganglioside separation, detection, and structural identification. Finally, the advantages and downsides of each methodology as well as the perspectives for simplification, standardization, and upgrading are assessed.  相似文献   

3.
A method for generation of novel fluorocarbon derivatives of glycosphingolipids (GSLs) with high affinity for fluorocarbon phases has been developed, and their potential applications to mass spectrometry (MS)‐based methodologies for glycosphingolipidomics have been investigated. Sphingolipid ceramide N‐deacylase (SCDase) is used to remove the fatty acid from the ceramide moiety, after which a fluorocarbon‐rich substituent (F‐Tag) is incorporated at the free amine of the sphingoid. In initial trials, a neutral GSL, globotriaosylceramide (Gb3Cer), three purified bovine brain gangliosides, and four fungal glycosylinositol phosphorylceramides (GIPCs) were de‐N‐acylated, derivatized by prototype F‐Tags, and recovered by solid phase extraction on fluorocarbon‐derivatized silica (F‐SPE). The efficacy of SCDase treatment of GIPCs was here demonstrated for the first time. Compatibility with subsequent per‐N,O‐methylation was established for the F‐tagged Gb3 Cer and purified gangliosides, and extensive mass spectra (MS1 and MS2) consistent with all of the expected products were acquired. The potential use of F‐tagged derivatives for a comprehensive MS based profiling application was then demonstrated on a crude ganglioside mixture extracted from bovine brain. Finally, a simple trial in microarray format demonstrated fixation of F‐tagged GM1 ganglioside to a fluorous glass surface, with the glycan intact and available for interaction with a fluorescent derivative of cholera toxin B chain. The methods described thus provide a new avenue for rapid GSL recovery or cleanup, potentially compatible with a variety of platforms for mass spectrometric profiling and structure analysis, as well as parallel analysis of functional interactions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
A general approach for the detection and structural elucidation of brain ganglioside species GM1, GD1 and GT1 by nano-electrospray ionization quadrupole time-of-flight (nanoESI-QTOF) mass spectrometry (MS), using combined data from MS and MS/MS analysis of isolated native ganglioside fractions in negative ion mode and their permethylated counterparts in the positive ion mode is presented. This approach was designed to detect and sequence gangliosides present in preparatively isolated ganglioside fractions from pathological brain samples available in only very limited amounts. In these fractions mixtures of homologue and isobaric structures are present, depending on the ceramide composition and the position of the sialic acid attachment site. The interpretation of data for the entire sequence, derived from A, B, C and Y ions by nanoESI-QTOFMS/MS in the negative ion mode of native fractions, can be compromised by ions arising from double and triple internal cleavages. To distinguish between isobaric carbohydrate structures in gangliosides, such as monosialogangliosides GM1a and GM1b, disialogangliosides GD1a, GD1b and GD1c or trisialogangliosides GT1b, GT1c and GT1d, the samples were analysed after permethylation in the positive ion nanoESI-QTOFMS/MS mode, providing set of data, which allows a clear distinction for assignment of outer and inner fragment ions according to their m/z values. The fragmentation patterns from native gangliosides obtained by low-energy collision induced dissociation (CID) by nanoESI-QTOF show common behaviour and follow inherent rules. The combined set of data from the negative and positive ion mode low-energy CID can serve for the detection of structural isomers in mixtures, and to trace new, not previously detected, components.  相似文献   

5.
Gangliosides are anionic glycosphingolipids widely distributed in vertebrate tissues and fluids. Their structural and quantitative expression patterns depend on phylogeny and are distinct down to the species level. In milk, gangliosides are exclusively associated with the milk fat globule membrane. They may participate in diverse biological processes but more specifically to host-pathogen interactions. However, due to the molecular complexities, the analysis needs extensive sample preparation, chromatographic separation, and even chemical reaction, which makes the process very complex and time-consuming. Here, we describe a rapid profiling method for bovine and human milk gangliosides employing matrix-assisted desorption/ionization (MALDI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS). Prior to the analyses of biological samples, milk ganglioside standards GM3 and GD3 fractions were first analyzed in order to validate this method. High mass accuracy and high resolution obtained from MALDI FTICR MS allow for the confident assignment of chain length and degree of unsaturation of the ceramide. For the structural elucidation, tandem mass spectrometry (MS/MS), specifically as collision-induced dissociation (CID) and infrared multiphoton dissociation (IRMPD) were employed. Complex ganglioside mixtures from bovine and human milk were further analyzed with this method. The samples were prepared by two consecutive chloroform/methanol extraction and solid phase extraction. We observed a number of differences between bovine milk and human milk. The common gangliosides in bovine and human milk are NeuAc-NeuAc-Hex-Hex-Cer (GD3) and NeuAc-Hex-Hex-Cer (GM3); whereas, the ion intensities of ganglioside species are different between two milk samples. Kendrick mass defect plot yields grouping of ganglioside peaks according to their structural similarities. Gangliosides were further probed by tandem MS to confirm the compositional and structural assignments. We found that only in human milk gangliosides was the ceramide carbon always even numbered, which is consistent with the notion that differences in the oligosaccharide and the ceramide moieties confer to their physiological distinctions.  相似文献   

6.
The combination of ion mobility with matrix-assisted laser desorption/ionization allows for the rapid separation and analysis of biomolecules in complex mixtures (such as tissue sections and cellular extracts), as isobaric lipid, peptide, and oligonucleotide molecular ions are pre-separated in the mobility cell before mass analysis. In this study, MALDI-IM MS is used to analyze gangliosides, a class of complex glycosphingolipids that has different degrees of sialylation. Both GD1a and GD1b, structural isomers, were studied to see the effects on gas-phase structure depending upon the localization of the sialic acids. A total ganglioside extract from mouse brain was also analyzed to measure the effectiveness of ion mobility to separate out the different ganglioside species in a complex mixture.  相似文献   

7.
High-resolution thin-layer chromatography of gangliosides   总被引:8,自引:0,他引:8  
In this review an updated overview of current improvements on thin-layer chromatography (TLC) of gangliosides over the past decade is provided. Basic general techniques and special advice is given for successful separation of glycosphingolipids. New approaches concerning continuous and multiple development, and several preparative TLC methods are also included. Emphasis is placed on TLC immunostaining and related techniques, i.e. practical applications of carbohydrate-specific antibodies, toxins and bacteria, viruses, lectins and eukaryotic cells. Thus, this review on ganglioside TLC summarizes its power as an analytical tool for a wide range of purposes.  相似文献   

8.
We have developed here a superior approach based on high‐resolution (HR) mass spectrometry (MS) for monitoring the changes occurring with development and aging in the composition and structure of cerebellar gangliosidome. The experiments were focused on the comparative screening and structural analysis of gangliosides expressed in fetal and aged cerebellum by Orbitrap MS with nanoelectrospray ionization (nanoESI) in the negative ion mode. The employed ultrahigh‐resolution MS platform allowed the discrimination, without the need of previous separation, of 159 ions corresponding to 120 distinct species in the native ganglioside mixtures from fetal and aged cerebellar biopsies, many more than detected before, when MS platforms of lower resolution were employed. A number of gangliosides, in particular polysialylated belonging to GT, GQ, GP, and GS classes, modified by O‐fucosylation, O‐acetylation, or CH3COO? were discovered here, for the first time in human cerebellum. These components, found differently expressed in fetal and aged tissues, indicated that the ganglioside profile in cerebellum is development stage‐ and age‐specific. Following the fragmentation analysis by high‐energy collision‐induced dissociation (HCD) tandem MS (MS/MS), we have also observed that the intimate structure of certain compounds has not changed during the development and aging of the brain, an aspect which could open new directions in the investigation of ganglioside biomarkers in cerebellar tissue.  相似文献   

9.
Separation of gangliosides by anion-exchange chromatography on Mono Q   总被引:1,自引:0,他引:1  
A new type of strong anion-exchange resin, Mono Q, has been used in the separation of brain gangliosides. The resin consists of monodisperse particles (9.8 micron) and was used in prepacked columns with a bed volume of 1 ml. The gangliosides were separated into mono-, di-, tri- and tetrasialoganglioside fractions by a discontinuous gradient of potassium acetate in methanol. The separation was complete in a volume of 50 ml. The major advantages of the new procedure compared to conventional methods are the shorter separation time, higher loading capacity and recovery of separated ganglioside fractions in small solvent volumes. The procedure was applied to the separation of gangliosides from normal human and GM2-gangliosidosis brain.  相似文献   

10.
In this study, we developed a high-resolution tandem mass spectrometry (HR MS) approach to assess presumed changes in gangliosidome of a human hippocampus affected by temporal lobe epilepsy (TLE) in comparison with a normal hippocampus. Gangliosides, membrane glycolipids, are particularly diverse and abundant in the human brain, and participate in ion transport and modulation of neuronal excitability. Changes in structural ganglioside pattern potentially linked to TLE molecular pathogenesis have not been explored in detail. Aiming to characterize TLE-specific gangliosidome, we analyzed the native gangliosides purified from a human hippocampal tissue sample affected by TLE and a control hippocampus using HR MS. Marked differences of ganglioside expression were shown in TLE vs. control, particularly with respect to the sialylation degree of components, discovered as a characteristic feature of TLE. Another major finding is the occurrence of tetrasialofucogangliosides in TLE and species modified by either O-acetylation or CH3COO. Structural analysis by higher-energy collisional dissociation (HCD) MS/MS gave rise to fragmentation patterns implying that the GQ1b (d18:1/18:0) isomer is specifically associated with TLE. Further investigation in a larger sample is needed in order to confirm the discovery of ganglioside structures specifically expressed in human TLE and to provide information on the probable role of gangliosides in the molecular events underlying seizures.  相似文献   

11.
Large part of the current research in biology, medicine, and biotechnology depends on the analysis of DNA (genomics), proteins (proteomics), or metabolites (metabolomics). The advances in biotechnology also command development of adequate analytical instrumentation capable to analyze minute amounts of samples. The analysis of the content of single cells may serve as an example of ultimate analytical applications. Most of the separation techniques have been developed in the last three decades and alternative approaches are being investigated. At present, the main protocols for analyses of complex mixtures include 2-DE (IEF) followed by electrophoresis in SDS polyacrylamide gel (SDS-PAGE) and chromatographic techniques. Information-rich techniques such as MS and NMR are essential for the identification and structure analysis of the analyzed compounds. High resolution separation of the individual sample components is often a prerequisite for success. High resolution proteomic analysis in the majority of laboratories still relies on the time consuming and laborious offline methods. This review highlights some of the important aspects of 2-D separations including microfluidics.  相似文献   

12.
Capillary electrophoresis (CE) offers fast and high‐resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user‐friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano‐electrospray ionization (ESI), matrix‐assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE‐MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two‐dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE‐modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.  相似文献   

13.
In the last decades, the basic techniques of microfluidics for the study of cells such as cell culture, cell separation, and cell lysis, have been well developed. Based on cell handling techniques, microfluidics has been widely applied in the field of PCR (Polymerase Chain Reaction), immunoassays, organ-on-chip, stem cell research, and analysis and identification of circulating tumor cells. As a major step in drug discovery, high-throughput screening allows rapid analysis of thousands of chemical, biochemical, genetic or pharmacological tests in parallel. In this review, we summarize the application of microfluidics in cell-based high throughput screening. The screening methods mentioned in this paper include approaches using the perfusion flow mode, the droplet mode, and the microarray mode. We also discuss the future development of microfluidic based high throughput screening platform for drug discovery.  相似文献   

14.
The hybrid ganglioside X1, which was identified in the bovine brain, was synthesized for the first time. Ganglioside X1 is believed to be involved in the development of amyotrophic lateral sclerosis-like disorders in patients with neurological disorders after treatment with bovine brain gangliosides. A convergent approach using two branched glycan units, the GM2-core trisaccharide and the lacto-ganglio tetrasaccharide, efficiently provided the highly branched heptasaccharide part of ganglioside X1, which was conjugated with the ceramide part to produce the protected ganglioside X1. Global deprotection delivered homogenous ganglioside X1, with which serum from the patient was reacted.  相似文献   

15.
Nano‐LC and CEC were coupled to MS through a nanospray or a pressurized liquid‐junction interface for the simultaneous separation and determination of 11 estrogenic compounds. Different stationary phases, that is, phenyl, C18, and C18 bidentate silica hydrate, were studied. For both techniques, the phenyl stationary phase was the best option, considering separation efficiency, selectivity, and resolution. Under the optimized conditions, the baseline separation of the target compounds (including estradiol and zearalanol epimers) was achieved in less than 20 min in nano‐LC‐MS and less than 13 min in CEC‐MS. Molecular imprinted polymer SPE was used for extracting the target compounds from mineral water samples with the analysis of nano‐LC‐MS. The whole molecular imprinted polymer SPE nano‐LC‐MS method was validated through a recovery study at two levels of concentration. Sensitivity was improved by on‐column focusing technique obtaining LODs in the range 1.4–55.4 ng/L.  相似文献   

16.
Application of capillary electrophoresis (CE) as a high-resolution separation technique in metalloproteomics research is critically reviewed. The focus is on the requirements and challenges involved in coupling CE to sensitive element and molecule-specific detection techniques such as inductively coupled plasma mass spectrometry (ICP–MS) or electrospray ionisation mass spectrometry (ESI–MS). The complementary application of both detection techniques to the structural and functional characterisation of metal-binding proteins and their structural metal-binding moieties is emphasised. Beneficial aspects and limitations of mass spectrometry hyphenated to CE are discussed, on the basis of the literature published in this field over the last decade. Recent metalloproteomics applications of CE are reviewed to demonstrate its potential and limitations in modern biochemical speciation analysis and to indicate future directions of this technique.  相似文献   

17.
Huang YF  Huang CC  Hu CC  Chang HT 《Electrophoresis》2006,27(18):3503-3522
CE offers the advantages of high speed, great efficiency, as well as the requirement of minimum amounts of sample and buffer for the analysis of proteins. In this review, we summarize the CE-based techniques coupled with absorption, LIF, and MS detection systems for the analysis of proteins mostly within the past 5 years. The basic principle of each technique and its advantages and disadvantages for protein analysis are discussed in brief. Advanced CE techniques, including on-column concentration techniques and high-efficiency multidimensional separation techniques, for high-throughput protein profiling of complex biological samples and/or of single cells are emphasized. Although the developed techniques provide improved peak capacity, they have not become practical tools for proteomics, mainly because of poor reproducibility, low-sample lading capacity, and low throughput due to ineffective interfaces between two separation dimensions and that between separation and MS systems. In order to identify the complexities and dynamics of the proteomes expressed by cells, tissues, or organisms, techniques providing improved analytical sensitivity, throughput, and dynamic ranges are still demanded.  相似文献   

18.
Abstract

Caudate nucleus (CN) is a specialized part of the dorsal striatum of each brain hemisphere involved in numerous cognitive processes. Caudate dysfunctions are associated with Alzheimer’s, Parkinson’s and Huntington’s disease, autism, and even schizophrenia. Most of the studies upon CN and related diseases were conducted using neuroimaging techniques, which, in some instances have reached contradictory conclusions. This state-of-the-art technique triggered the development of methods able to provide information at the molecular level. In this context, here we have implemented high resolution (HR) mass spectrometry (MS) and multistage MS (MSn), for mapping and structural analysis of gangliosides in human CN. Due to the high resolution and mass accuracy (average value: 1.5?ppm), 100 distinct species, of which 90 were di-, tri-, tetra-, and pentasialylated and 17 fucosylated and acetylated and, for the first time, species modified by CH3COO?, were reliably identified in the native CN ganglioside extract. Additionally, two structurally-relevant species, GD2 (d18:1/18:0) and GD2 (d18:1/16:2), were characterized with MS2–MS3 by collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD). The set of data collected by high-resolution mass spectrometry (HR-MS) revealed a much higher complexity of the CN ganglioside pattern than ever reported, and the species associated to this brain region, potentially implicated in many of its functions.  相似文献   

19.
Pharmaceuticals have become major targets in environmental chemistry due to their presence in aquatic environments (following incomplete removal in wastewater treatment or point-source contaminations), threat to drinking water sources and concern about their possible effects to wildlife and humans. Recently several methods have been developed for the determination of drugs and their metabolites in the lower nanogram per litre range, most of them using solid-phase extraction (SPE) or solid-phase microextraction (SPME), derivatisation and finally gas chromatography mass spectrometry (GC-MS), gas chromatography tandem mass spectrometry (GC-MS/MS) and liquid chromatography electrospray tandem mass spectrometry (LC-ES/MS/MS). Due to the elevated polarity of non-steroidal anti-inflamatory drugs (NSAIDs), analytical techniques based on either liquid chromatography coupled to mass spectrometry (LC-MS) and gas chromatography coupled to mass spectrometry (GC-MS) after a previous derivatisation step are essential. The most advanced aspects of current GC-MS, GC-MS/MS and LC-MS/MS methodologies for NSAID analysis are presented.  相似文献   

20.
Although laser ablation (LA)‐ICP‐MS has been reported for the determination of metalloproteins separated by gel electrophoretic techniques (GE), systematic studies that define the conditions essential for successful measurements are still scarce. In this paper we present the results of our studies of basic conditions for the effective application of GE‐LA‐ICP‐MS for the separation of metal‐binding proteins, focusing on their stability during GE and post‐separation gel treatment. The stability of metal–protein complexes (haemoglobin, myoglobin, superoxide dismutase, carbonic anhydrase, transferrin, albumin, cytochrome c) during GE is dependent on the nature of the metal–protein interaction and the principle of separation. We have observed that non‐denaturing GE is a suitable separation technique for most metal–protein complexes (e.g. Zn in carbonic anhydrase and Fe in Tf and myoglobin were quantitatively recovered in a spiked liver cytosol), whereas separation by denaturing GE strongly impaired the stability of the complexes. Equally important is the post‐separation treatment of the gel to enable successful detection of the metal. LA‐ICP‐MS requires drying of the gel without loss of protein‐bound metal or cracking of the gel. This was successfully achieved using glycerol followed by heating. We demonstrate that staining of the gel prior to LA‐ICP‐MS using silver or Coomassie blue is not recommended, since most protein‐bound metal is lost during the staining procedure. Furthermore it has been shown that only line scanning with a speed of less than 30 μm/s can reliably distinguish between lines 1 mm apart, while raster spot analysis carries the risk of misinterpretation due to contamination in/on inhomogeneous gels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号