首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 μm polystyrene particles, 5 μm polystyrene particles, 5 μm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.  相似文献   

2.
A novel method is reported to enhance the focusing of microparticle in the viscoelastic fluid. Gradually contracted geometry is designed in microchannel, which changes the distribution of the elastic lift force on the cross section. Additionally, it induces the viscous drag force and the Saffman lift force in the lateral direction. Under the combined effect of these forces, microparticles fast migrate to the center of the channel. In comparison to the channel with constant cross section, the present channel significantly enhances the particle's lateral migration, leading to efficient viscoelastic particle focusing in a short channel length. The influence of flow rate, channel length, particle size and fluid property on the particle focusing is also investigated. With simple structure, small footprint and perfect particle focusing performance, the present device has great potential in the particle focusing processes in various lab-on-a-chip applications.  相似文献   

3.
Nanoparticles with specific properties and functions have been developed for various biomedical research applications, such as in vivo and in vitro sensors, imaging agents and delivery vehicles of therapeutics. The development of an effective delivery method of nanoparticles into the intracellular environment is challenging and success in this endeavor would be beneficial to many biological studies. Here, the well-established microelectrophoresis technique was applied for the first time to deliver nanoparticles into living cells. An optimal protocol was explored to prepare semiconductive quantum dots suspensions having high monodispersity with average hydrodynamic diameter of 13.2–35.0 nm. Micropipettes were fabricated to have inner tip diameters of approximately 200 nm that are larger than quantum dots for ejection but less than 500 nm to minimize damage to the cell membrane. We demonstrated the successful delivery of quantum dots via small electrical currents (–0.2 nA) through micropipettes into the cytoplasm of living human embryonic kidney cells (roughly 20–30 μm in length) using microelectrophoresis technique. This method is promising as a simple and general strategy for delivering a variety of nanoparticles into the cellular environment.  相似文献   

4.
A passive microfluidic device is reported for continuous microparticle enrichment. The microparticle is enriched based on the inertial effect in a microchannel with contracting‐expanding structures on one side where microparticles/cells are subjected to the inertial lift force and the momentum‐change‐induced inertial force induced by highly curved streamlines. Under the combined effect of the two forces, yeast cells and microparticles of different sizes were continuously focused in the present device over a range of Reynolds numbers from 16.7 to 125. ~68% of the particle‐free liquid was separated from the sample at Re = 66.7, and ~18 μL particle‐free liquid was fast obtained within 10 s. Results also showed that the geometry of the contracting‐expanding structure significantly influenced the lateral migration of the particle. Structures with a large angle induced strong inertial effect and weak disturbance effect of vortex on the particle, both of which enhanced the microparticle enrichment in microchannel. With simple structure, small footprint (18 × 0.35 mm), easy operation and cell‐friendly property, the present device has great potential in biomedical applications, such as the enrichment of cells and the fast extraction of plasma from blood for disease diagnose and therapy.  相似文献   

5.
The effect of microstructure on the aggregation behaviour of symmetrical di- and triblock copolymers P(BMA)-b-P(MAA) and P(BMA)-b-P(BMA-co-MAA)-b-P(MAA) with a molecular weight of 40,000 g/mol was studied. The critical micelle concentration, hydrodynamic radius and morphology of the micelles were determined by fluorescence spectroscopy, dynamic light scattering and scanning force microscopy (SFM). Whereas no effect of the microstructure on the critical micelle concentration could be detected, the hydrodynamic radius decreased from di- to triblock copolymer from 53 to 36 nm. The decrease of about 32% corresponds to the length of the random middle block within the triblock copolymer so that the reduction in hydrodynamic radius was caused by a complete orientation of the random middle block at the core corona interface. Finally, the SFM investigation showed that dehydration of micelles on a substrate is accompanied by formation of a physisorbed monolayer with a thickness of 2 nm on which the micelles are deposited.  相似文献   

6.
Thirty years ago there was considerable excitement over the first report of a long-ranged “hydrophobic force” between solids that were not wet by water (Israelachvili and Pashley, Nature 1982, 300, 341–342). Many of the subsequent measurements have been reexamined and found not to support the existence of a long-range hydrophobic force. The principal difficulty was that hydrophobic solids frequently experience other forces, which obscured or were mistaken for a hydrophobic force. In this paper, we review the surviving evidence for a long-range hydrophobic force and find that there is only supporting evidence in a total of two papers, one old and one new, where net attractive forces were measured at separations greater than about 5–6 nm. Thus the evidence is scarce. In contrast there are new experiments showing no such force, thereby arguing against the universality of a measureable hydrophobic force beyond about 6 nm. Since solvent water is common to the experiments, such evidence makes it difficult to describe a universal mechanism for a long-ranged hydrophobic force based on water structure. There are also new measurements that are consistent with a hydrophobic force with a decay length in the range 0.3–1.0 nm. In particular, attractive forces have been measured on small radius surfaces (8–50 nm) consistent with a hydrophobic force with a decay length of 0.5–0.6 nm, and a variety of net repulsive measurements are consistent with an attractive hydrophobic force that has a decay length of 0.3–1.0 nm. We also discuss some new measurements, which are consistent with cavitation, and not a surface force that acts at a distance.  相似文献   

7.
This work presents a facile and efficient electropolishing of metallic titanium (Ti) in the relatively eco-friendly electrolyte of deep eutectic solvent (DES) using a mixture of choline chloride-propylene glycol (1 mol ChCl: 2 mol PG). The electropolishing process of metallic titanium was performed under potentiostatic condition (10 V for 40 min) at room temperature. Surface topography and morphology were investigated using scanning electron microscope (SEM) and atomic force microscopy (AFM). The promising electropolishing provides a shiny and mirror-like surface with an average surface roughness (Ra) of 37.92 nm from the parent metallic Ti with a roughness of 455.60 nm. The surface passivation after electropolishing is of the most likely acceptable mechanism for removing microscope roughness. The proposed electropolishing in the present DES electrolyte is a promising strategy for making mirror-like surface (surface resistive against corrosion) of biomedical metallic titanium.  相似文献   

8.
Separation of microparticle in viscoelastic fluid is highly required in the field of biology and clinical medicine. For instance, the separation of the target cell from blood is an important prerequisite step for the drug screening and design. The microfluidic device is an efficient way to achieve the separation of the microparticle in the viscoelastic fluid. However, the existing microfluidic methods often have some limitations, including the requirement of the long channel length, the labeling process, and the low throughput. In this work, based on the elastic-inertial effect in the viscoelastic fluid, a new separation method is proposed where a gradually contracted microchannel is designed to efficiently adjust the forces exerted on the particle, eventually achieving the high-efficiency separation of different sized particles in a short channel length and at a high throughput. In addition, the separation of WBCs and RBCs is also validated in the present device. The effect of the flow rate, the fluid property, and the channel geometry on the particle separation is systematically investigated by the experiment. With the advantage of small footprint, simple structure, high throughput, and high efficiency, the present microfluidic device could be utilized in the biological and clinical fields, such as the cell analysis and disease diagnosis.  相似文献   

9.
By nanosecond, 532-nm laser irradiation typically at approximately 1 J/(cm2 pulse), water-suspended thin gold flakes, 0.1-0.2-microm thick but more than 10-microm across, were efficiently fragmented in a unique two-step mode, as evidenced by the in situ extinction spectra taken as a function of the laser irradiation time. The initial main photoproducts were spherical gold particles in the submicrometer regime. Their ensuing laser fragmentation in oxygen-free water environment generated stable, negatively charged, fine nanoparticles less than 10 nm in diameter, characterized by a considerably weak and blue-shifted plasmon band. The Mie theory can reproduce these distinct spectral features of the fine nanoparticles as well as the scattering-dominated extinction spectra of the submicroparticles. The submicroparticle to nanoparticle conversion seemed most likely to be a single-pulse event, not leaving any larger intermediate nanoparticles in the suspension. Oxygen, as an effective electron acceptor, strongly affected the stability of the negatively charged nanoparticles, promoting their quasi-reversible or irreversible agglomeration. From the estimated balance between the absorbed laser energy and the energies for the relevant particles to produce a high-temperature molten state, possible fragmentation mechanisms are discussed.  相似文献   

10.
A ternary nanocomposite (TNC) was fabricated for introducing multifunctional properties for various biomedical applications. The nanocomposites consist of hydroxyapatite (HAP) combined with/without graphene oxide (GO) and gadolinium oxide (Gd2O3). The lattice constants of HAP were around 9.4285 and 6.7476 Å, while for Gd2O3 was around 10.8441 Å. The morphological investigation detected the nanosheets of GO, and nanorods of HAP/Gd2O3 with length of 27 nm. Moreover, the topological study based on a field emission scanning electron microscope (FESEM) showed that HAP/GO had average roughness (Ra) of 4.8 nm, and the root mean square value (Rq) with a value of 7 nm. Furthermore, the average pore size reached 7.99 nm for the NC of HAP/GO. In addition, the cumulative surface area using the density functional theory (DFT) method was calculated at around 44.61 m2/g for TNC. The cell viability in vitro of osteoblast cell line improved from 95.6 ± 0.6% to 96.7 ± 0.5% which indicates the biocompatibility of the implants to be used in biomedical applications.  相似文献   

11.
《Electrophoresis》2018,39(2):417-424
Herein, we proposed a strategy for controlling the particle focusing position in Dean‐coupled elasto‐inertial flows via adjusting the polymer concentration of viscoelastic fluids. The physics behind the control strategy was then explored and discussed. At high polymer concentrations, the flowing particles could be single‐line focused exactly at the channel centerline under the dominated elastic force. The center‐line focusing in our spiral channel may employed as a potential pretreatment scheme for microflow cytometry detection. With further decreasing polymer concentrations, the particles would shift into the outer channel region under the comparable competition between inertial lift force, elastic force and Dean drag force. Finally, the observed position‐shifting was successfully employed for particle concentration at a throughput much higher than most existing elasto‐inertial microfluidics.  相似文献   

12.
Concentration polarization (CP)-based focusing electrokinetics nanofluidic devices have been developed in order to simultaneously detect and enrich highly diluted analytes on-a-chip. However, stabilization of focal points over long time under the application of the electric field remains as a technical bottleneck. If pressure-assisted preconcentration methods have been proposed to stabilize propagating modes at low inverse Dukhin number , these recent protocols remain laborious for optimizing experimental parameters. In this paper, “electric field E/counter-pressure P” diagrams have been established during pressure-assisted electro-preconcentration of fluorescein as a model molecule. Such E/P diagram allows direct observation of the region for which the optimal counter-pressure P leads to a stable focusing regime. This region of stable focusing is shown to vary depending of the nanoslit length (100 μm < Lnanoslit < 500 μm) and the nature of the background electrolyte (KCl and NaCl). Longer nanoslits (500 μm) produce stabilization at low counter-pressure P, whereas NaCl offers a narrower region of stable focusing in the E/P diagram compared to KCl. Finally, the ability of such pressure-assisted protocol to concentrate negatively charged proteins has been tested with a more applicative protein, i.e., ovalbumin. The corresponding E/P diagram confirms the existence of the stable focusing regime at both low electric field E (≤20 V) and counter-pressure P (≤0.4 bar). With an enrichment factor as high as 70 after 2 min for ovalbumin at a concentration of 10 μM, such pressure-assisted nanofluidic electro-preconcentration protocol appears very promising to concentrate and detect biomolecules.  相似文献   

13.
This paper concerns the slow viscous flow of an incompressible fluid past a swarm of identically oriented porous deformed spheroidal particles, using particle-in-cell method. The Brinkman’s equation in the porous region and the Stokes equation for clear fluid region in their stream function formulations are used. Explicit expressions are investigated for both the inside and outside flow fields to the first order in a small parameter characterizing the deformation. The flow through the porous oblate spheroid is considered as the particular case of the porous deformed spheroid. The hydrodynamic drag force experienced by a porous oblate spheroid and permeability of a membrane built up by porous oblate spheroids having parallel axis are evaluated. The dependence of the hydrodynamic drag force and the hydrodynamic permeability on particle volume fraction, deformation parameter and viscosity of porous fluid are also discussed. Four known boundary conditions on the hypothetical surface are considered and compared: Happel’s, Kuwabara’s, Kvashnin’s and Cunningham’s (Mehta-Morse’s condition). Some previous results for hydrodynamic drag force and hydrodynamic permeability have been verified. The model suggested can be used for evaluation of changing hydrodynamic permeability of a membrane under applying unidirectional loading in pressure-driven processes (reverse osmosis, nano-, ultra- and microfiltration).  相似文献   

14.
Choi YS  Seo KW  Lee SJ 《Lab on a chip》2011,11(3):460-465
The inertial migration of particles in micro-scale flows has received much attention due to its promising applications, such as the membrane-free passive separation of particles or cells. The particles suspended in rectangular channels are known to be focused near the center of each channel face as the channel Reynolds number (R(C)) increases due to the lift force balance and the hydrodynamic interactions of the particles with the wall. In this study, the three-dimensional positions of neutrally buoyant spherical particles inside a square microchannel are measured using the digital holographic microscopy technique, and a transition from the lateral tubular pinch to the cross-lateral focusing with increasing R(C) is reported. The particles are found to migrate first in the lateral direction and then cross-laterally toward the four equilibrium positions. A general criterion that can be used to secure the fully developed state of particle focusing in Lab-on-a-Chip applications is also derived. This criterion could be helpful for the accurate estimation of the design parameters of inertial microfluidic devices, such as R(C), channel length and width, and particle diameter.  相似文献   

15.

The hydrodynamic force (drag) on spherical and irregularly shaped particles significantly increases when the particles move close to solid and permeable boundaries. The overall effect of the increased hydrodynamic drag is to hinder the particle movement in the vicinity of boundaries and this includes the Brownian movement and electrophoresis. The Monte Carlo simulation method is used to model the Brownian movement, the resulting diffusion, and the electrophoresis of spherical particles in narrow, cylindrical pores, filled with Newtonian fluids. It is observed that the effect of the pore walls is a significant reduction of the space-averaged electrophoretic velocity of the particles, which implies reduced particle flux through the pores. The hindered electrophoresis is primarily a geometric phenomenon, caused by the increased drag and depends on the size of the particles and the pore-to-particle diameter ratio. The temperature of the fluid slightly affects the hindered electrophoresis through its effect on the viscosity, which is a determinant of the Brownian force, the diffusivity and the electrophoretic velocity. The hindered electrophoresis is almost independent of the other fluid and particle properties, such as density. Based on the simulation results a non-linear correlation for the flux of particles is derived, valid in the ranges 5?<?R/α?<?120, 5 nm?<?α?<?100 nm and 273 K?<?T?<?355 K.

  相似文献   

16.
《Electrophoresis》2018,39(11):1399-1409
The precursor compounds related to the bitterness of beer are called α‐acids. These compounds are extracted from the hop, which is an important ingredient in the brewing process. These compounds were analyzed by capillary electrophoresis. The electrophoretic method used 160 mmol/L of ammonium carbonate (pH 9) as BGE (background electrolyte), a voltage of +20 kV in a capillary with 50 μm of internal diameter and with a 62.5 cm of total length (54 cm effective). The samples were injected in hydrodynamic mode applying a pressure of 25 mbar for 5 s and the analytes were detected at 230 nm. A hydromethanolic extraction during 3 h was considered as the optimum condition for the sample preparation using MeOH/H2O 80:20 v/v as the extract solution. From the optimized conditions the electropherograms were evaluated for their use as input for chemometric modeling. Preprocessing investigation for electrophoretic data taking into account the alignment, denoising and baseline correction, and variable selection were considered before the chemometric modeling using principal component analysis (PCA). The electrophoretic data were systematically evaluated to find the optimum conditions to modeling. A PCA analysis for all tests was carried out using different preprocessing methods and, an explained variance higher than 90% was achieved in all of them. The optimized chemometric method worked with aligned and meancentered data. From this approach, a simple and efficient method to classify hop samples with high and low α‐acids content without the use of analytical standards was established from a simple electrophoretic analysis.  相似文献   

17.
Yang S  Kim JY  Lee SJ  Lee SS  Kim JM 《Lab on a chip》2011,11(2):266-273
Particle focusing in planar geometries is essentially required in order to develop cost-effective lab-on-a-chips, such as cell counting and point-of-care (POC) devices. In this study, a novel method for sheathless particle focusing, called "Elasto-Inertial Particle Focusing", was demonstrated in a straight microchannel. The particles were notably aligned along the centerline of the straight channel under a pressure-driven flow without any additional external force or apparatus after the addition of an elasticity enhancer: PEO (poly(ethylene oxide)) (~O(100) ppm). As theoretically predicted (elasticity number: El≈O(100)), multiple equilibrium positions (centerline and corners) were observed for the viscoelastic flow without inertia, whereas three-dimensional particle focusing only occurred when neither the elasticity nor the inertia was negligible. Therefore, the three-dimensional particle focusing mechanism was attributed to the synergetic combination of the elasticity and the inertia (elasticity number: El≈O(1-10)). Furthermore, from the size dependence of the elastic force upon particles, we demonstrated that a mixture of 5.9 and 2.4 μm particles was separated at the exit of the channel in viscoelastic flows. We expect that this method can contribute to develop the miniaturized flow cytometry and microdevices for cell and particle manipulation.  相似文献   

18.
We present an approach for the accumulation and filtering of nano- and microparticles in microfluidic devices that is based on the generation of electric traveling waves in the radio-frequency range. Upon application of the electric field via a microelectrode array, complex particle trajectories and particle accumulation are observed in well-defined regions in a microchannel. Through the quantitative mapping of the 3-D flow pattern using two-focus fluorescence cross-correlation spectroscopy, two vortices could be identified as one of the sources of the force field that induces the formation of particle clouds. Dielectrophoretic forces that directly act on the particles are the second source of the force field. A thorough 2-D finite element analysis identifies the electric traveling wave mechanism as the cause for the unexpected flow behavior observed. Based on these findings, strategies are discussed, first, for avoiding the vortices to optimize electrohydrodynamic micropumps and, secondly, for utilizing the vortices in the development of microdevices for efficient particle accumulation, separation, and filtering. Such devices may find numerous biomedical applications when highly diluted nano- and microsuspensions have to be processed.  相似文献   

19.
Nan Xiang  Silin Wang  Zhonghua Ni 《Electrophoresis》2021,42(21-22):2256-2263
Elastic-inertial focusing has attracted increasing interest in recent years due to the three-dimensional (3D) single-train focusing ability it offers. However, multi-train focusing, instead of single-train focusing, was observed in viscoelastic fluids with low elasticity as a result of the competition between inertia effect and viscoelasticity effect. To address this issue, we employed the secondary flow to facilitate single-train elastic-inertial focusing in low elasticity viscoelastic fluids. A three-section contraction-expansion channel was designed to induce the secondary flow to pinch the multiplex focusing trains into a single one exactly at the channel centerline. After demonstrating the focusing process and mechanism in our device, we systematically explored and discussed the effects of particle diameter, operational flow rate, polymer concentration, and channel dimension on particle focusing performances. Our device enables single-train focusing of particles in viscoelastic fluids with low elasticity, and offers advantages of planar single-layer structure, and sheathless, external-field free operation.  相似文献   

20.
A quantitative theory of hydrodynamic interactions in unentangled polymer melts and concentrated solutions is presented. The study is focussed on the pre-Rouse transient time regimes (t < τ(R), the Rouse relaxation time) where the hydrodynamic response is governed mainly by the viscoelastic effects. It is shown that transient viscoelastic hydrodynamic interactions are not suppressed (screened) at large distances and are virtually independent of polymer molecular mass. A number of transient regimes of unusual and qualitatively different behavior of isotropic and anisotropic hydrodynamic response functions are elucidated. The regimes are characterized in terms of two main length-scale dependent characteristic times: momentum spreading time τ(i) ∝ r(4∕3) and viscoelastic time τ(?) ∝ r(4). It is shown that for t > τ(i) the viscoelastic hydrodynamic interactions can be described in terms of the time or length scale dependent effective viscosity which, for t < τ(R) and/or for r < R(coil), turns out to be much lower than the macroscopic "polymer" viscosity η(m). The theory also involves a quantitative analysis of the length-scale dependent stress relaxation in polymer melts. The general predictions for hydrodynamic interactions in thermostated systems with Langevin friction are obtained as well.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号