首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, the determination of gallic acid was performed using surface-renewable carbon paste electrodes fabricated with multi-walled carbon nanotubes (MWCNT) and a mixture of N-octylpyridinium hexafluorophosphate (OPyPF6) ionic liquid with mineral oil (MO) as binder. This system shows remarkable amperometric sensor characteristics and promotes a better electronic transfer. An electroanalytical study of gallic acid shows a linear range from 4.98±0.25 to 74.1±2.2 μmol L−1, with R2=0.9958 and an experiment a limit of detection of 2.70±0.08 μmol L−1 (S/N=3), and a sensitivity of 0.029 μA μmol−1 L.  相似文献   

2.
Direct electron transfer of immobilized superoxide dismutase (Cu, Zn‐SOD) onto silicon carbide (SiC) nanoparticles displays a pair of well defined and nearly reversible redox peaks with formal potential (′) of −0.03 V in pH 7.4. The heterogeneous electron transfer rate constant (ks) and surface coverage (Γ) of immobilized SOD are 11.0±0.4 s−1 and 1.42×10−11 mol cm−2. Biosensor shows fast amperometric response (3s) with sensitivity and detection limit of 1.416 nA μM−1, 1.66 μM, and 1.375 nA μM−1, 2.1 μM for cathodically or anodically detection of superoxide, respectively. This biosensor also exhibits good stability, reproducibility and long life‐time.  相似文献   

3.
Summary: Anthracene sulfonic acid doped polyaniline nanomaterials were prepared through the chemical oxidative polymerisation process. Ammonium peroxydisulfate (APS) was employed as oxidant. Scanning electron microscopy (SEM) results show the resultant polyaniline (PANi) materials exhibited nanofibrillar morphology with diameter sizes less than 300 nm. Using the nanofibrillar PANI, amperometric biosensors for H2O2 and erythromycin were constructed through the drop-coating technique. Anthracene sulfonic acid (ASA) doped PANi and the test enzymes horseradish peroxidase, (HRP), or cytochrome P450 3A4, (CYP4503A4) were mixed in phosphate buffer solution before drop coating onto the electrode. The resultant biosensors displayed typical Michaelis-Menten behaviour. The apparent Michaelis-Menten constant obtained was 0.18 ± 0.01 mM and 0.80 ± 0.02 µM L−1 for the peroxide and erythromycin biosensor respectively. The sensitivity for the peroxide sensor was 3.3 × 10−3 A · cm−2 · mM−1, and the detection limit was found to be 1.2 × 10−2 mM respectively. Similarly, the sensitivity for the erythromycin sensor was in the same order at 1.57 × 10−3 A · cm−2 · mM−1 and detection limit was found to be 7.58 × 10−2 µM.  相似文献   

4.
《Electroanalysis》2017,29(12):2698-2707
A cholesterol biosensor based on cholesterol oxidase‐poly(diallyldimethylammonium chloride)‐carbon nanotubes‐nickel ferrite nanoparticles (ChOx‐PDDA‐CNTs‐NiFe2O4NPs) solution is easily fabricated by using a single dropping step on a glassy carbon electrode (GCE) surface. This technique is an alternative way to reduce complexity, cost and time to produce the biosensor. The uniformly dispersed materials on the electrode surface enhance the catalytic reaction of cholesterol oxidase and electron transfer from the oxidation of hydrogen peroxide in the system. The nickel ferrite nanoparticles were synthesized by co‐precipitation and calcination at various temperatures. These nanoparticles were then characterized using field emission scanning electron microscopy (FE‐SEM), energy‐dispersive X‐ray spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV) and X‐ray diffraction (XRD). The synthesized material calcined at 700 °C was well defined and presented the octahedral metal stretching with cubic NiFe2O4NPs phase. In cyclic voltammetric study, the ChOx‐PDDA‐CNTs‐NiFe2O4NPs/GCE showed 0.43 s−1 charge transfer rate constant (K s), 7.79×10−6 cm2 s−1 diffusion coefficient value (D ), 0.13 mm2 electroactive surface area (A e) and 3.58×10−8 mol cm−2 surface concentration ( ). This modified electrode exhibits stability in term of percent relative standard deviation (%RSD=0.62 %, n=10), reproducibility (%RSD=0.81, n=10), high sensitivity (25.76 nA per mg L−1 cm−2), linearity from 1 to 5,000 mg L−1 (R2=0.998) with a low detection limit (0.50 mg L−1). Its Michaelis‐Menten constant (K m) was 0.14 mM with 0.92 μA maximum current (I max) and demonstrated good selectivity without the effects of electroactive species such as ascorbic acid, glucose and uric acid. The cholesterol biosensor was successfully applied to determine cholesterol levels in human blood samples, showing promise due to its simplicity and availability.  相似文献   

5.
A novel metal composite material based on zirconium dioxide decorated gold nanoparticles (ZrO2@AuNPs), copper (I) oxide at manganese (IV) oxide (Cu2O@MnO2) and immobilized choline oxidase (ChOx) onto a glassy carbon electrode (GCE) (ChOx/Cu2O@MnO2-ZrO2@AuNPs/GCE) has been developed for enhancing the electro-catalytic property, sensitivity and stability of the amperometric choline biosensor. The ChOx/Cu2O@MnO2-ZrO2@AuNPs/GCE displayed an excellent electrocatalytic response to the oxidation of the byproduct H2O2 from the choline catalyzed reaction, which exhibited a charge transfer rate constant (Ks) of 0.97 s−1, a diffusion coefficient value (D) of 4.50×10−6 cm2 s−1, an electroactive surface area (Ae) of 0.97 cm2 and a surface concentration (γ) of 0.54×10−8 mol cm−2. The modified electrode also provided a wide linear range of choline concentration from 0.5 to 1,000.0 μM with good sensitivity (97.4 μA cm−2 mM−1) and low detection limit (0.3 μM). The apparent Michaelis-Menten constant was found to be 0.08 mM with Imax of 0.67 μA. This choline biosensor presented high repeatability (%RSD=2.9, n=5), excellent reproducibility (%RSD=2.9, n=5), long time of use (n=28 with %I>50.0 %) and good selectivity without interfering effects from possible electroactive species such as ascorbic acid, aspirin, amoxicillin, caffeine, dopamine, glucose, sucrose and uric acid. This optimal method was successfully applied for choline measurement in prepared human blood samples which demonstrated accurate and excellent reliability in the recovery range from 96.7 to 102.0 %.  相似文献   

6.
Metal organic frameworks (MOFs) have attracted extensive attention in electrochemical research fields due to their high surface area and controlled porosity. Current study is design to investigate the ECL performance of the chemically modified electrode (CME) based on the bio-MOF-1, a porous zinc-adenine framework, which loaded ruthenium complex and employed for the detection of dopamine (DA). The composite material [Ru(bpy)3]2+@bio-MOF-1 (Ru-bMOF) modified carbon glassy electrode (Ru-bMOF/GCE) exhibited an excellent ECL performance having a linear co-efficient response (R2=0.9968) for 2-(dibutyl amino) ethanol (DBAE), a classical ECL co-reactant was obtained over a concentration range of 1.0×10−9 M to 1.0×10−4 M in 0.10 M pH=6.0 phosphate buffer solution (PBS). Furthermore, DA was detected based on its inhibition effect on [Ru(bpy)3]2+/DBAE system. Compared to traditional analytical methods, this method has various advantages such as simple electrode preparation, quick response, high reproducibility (RSD<2.0 %), low limit of detection (LOD=1.0×10−10 mol/L). This chemical investigated modified electrode had exploited potential for detection of DA.  相似文献   

7.
《Electroanalysis》2018,30(5):910-920
A label‐free DNA biosensor based on magnetite/multiwalled carbon nanotubes/chitosan (Fe3O4/MWCNTs‐COOH/CS) nanomaterial for detection of Bacillus cereus DNA sequences was fabricated. Negatively charged DNA was electrostatically adsorbed onto materials by protonation of positively charged chitosan under acidic conditions. The electrode surface and hybridization process were carried out by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimal conditions, the biosensor showed a good linear relationship between peak currents difference (ΔI) and logarithm of the target DNA concentration (Log C) ranging from 2.0×10−13 to 2.0×10−6 M with a detection limit of 2.0×10−15 M (signal/noise ratio of 3). The biosensor also revealed an excellent selectivity to three‐base, completely mismatched and completely matched DNA. This is a simple, fast and friendly method with a low detection limit for the detection of Bacillus cereus specific DNA compared with previously reported electrochemical DNA biosensor. Furthermore, the DNA biosensor may lead to the development of a technology for gold prospecting in the wild.  相似文献   

8.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

9.
The effects of several organotin(IV) meso‐tetra(4‐carboxyphenyl)porphinate] derivatives with the general formula (R2Sn)2TPPC and (R3Sn)4TPPC (R = Me, Bu, Ph) were tested in vivo on ascidian embryonic development. Embryos at the two‐cell stage were incubated in 1 × 10−5 or 1 × 10−7 M solutions of various compounds. The ligand, [meso‐tetra(4‐carboxyphenyl)porphine] (H4TPPC) was toxic at 1 × 10−5 M , because development was blocked at an early gastrula stage, whereas 1 × 10−7 M H4TPPC allowed the eggs to develop up to the larva stage. The most toxic among the tested compounds was tributyltin(IV) [meso‐tetra(4‐carboxyphenyl)porphinate], (Bu3Sn)4TPPC, since the fertilized eggs were unable to divide into two cells, even at a concentration of 1 × 10−7 M . To correlate this embryonic arrest with the metabolic pathway, and especially to understand why cellular organelles first underwent chemical damage, 10−5 and 10−7 M (Bu3Sn)4TPPC‐cultured fertilized eggs were tested for DNA, RNA, protein, glucose, lipid and ATP contents, comparing the values obtained with those of control culture fertilized egg contents. The higher concentration (1 × 10−5 M ) reduced the content of all the tested compounds, but the lower one (1 × 10−7 M ), even if still unable to allow cleavage, reduced only the lipids and the ATP contents. A hypothesis concerning initial damage to mitochondrial membrane is proposed. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

10.
In this work, a renewable tyrosinase-based biosensor was developed for the detection of catechol, using a carbon black paste electrode, without any mediator. The effect of pH, type of electrolyte, and amount of tyrosinase enzyme were explored for optimum analytical performance. The best-performing biosensor in amperometric experiments at potential −0.2 V vs. Ag/AgCl (3 mol L−1 KCl) was obtained using a 0.1 mol L−1 phosphate buffer solution (pH 7.0) as electrolyte. Under optimized conditions, the proposed biosensor had two concentration linear ranges from 5.0×10−9 to 4.8×10−8 and from 4.8×10−8 to 8.5×10−6 mol L−1 and a limit of detection of 1.5×10−9 mol L−1. The apparent Michaelis-Menten constant ( ) was calculated by the amperometric method, and the obtained value was 1.2×10−5 mol L−1 whose result was similar when compared with other studies previously. The biosensor was applied in river water samples, and the results were very satisfactory, with recoveries near 100 %. In addition, the response of this biosensor for different compounds, taking into account their molecular structures was investigated and the results obtained showed no interference with the response potential of catechol. The electrochemical biosensor developed in this work can be considered highly advantageous because it does not require the use of a mediator (direct detection) for electrochemical response, and also because it is based on a low-cost materials that can be used with success to immobilise other enzymes and/or biomolecules.  相似文献   

11.
A sensitive electrochemiluminescence (ECL) biosensor for the specific DNA sequence of hepatitis C virus (HCV) was developed based on the efficient quenching effect of the ferrocene cluster functionalized gold nanoparticles (Fc@AuNPs) on the ECL of electrodeposited silica@Ru(bpy)32+-chitosan-graphene oxide nanocomposite (SiO2@Ru−CS−GO). Graphene oxide (GO) can accelerate electron transfer rate, thus improving the ECL of Ru(bpy)32+ on electrode surface. The molecular beacons (MB) was fixed to SiO2@Ru−CS−GO by glutaraldehyde (GA) using the Schiff reaction between amino groups of chitosan (CS) and MB. The ECL of SiO2@Ru−CS−GO was depressed greatly by the Fc@AuNPs labelled at the end of MB, then, a stronger ECL was observed when the distance between Fc@AuNPs and SiO2@Ru−CS−GO increased after the hybridization of target DNA with MB. Under optimum conditions, the restored ECL intensity increased linearly with the target DNA concentration in the range of 1.0×10−16∼1.0×10−10 mol ⋅ L−1, and the limit of detection (LOD) is 1.4×10−17 mol ⋅ L−1. The proposed method exhibits acceptable stability and reproducibility. In general, the constructed HCV biosensor can be used for the sensitive detection of HCV in human serum, suggesting potential application prospects in bioanalysis.  相似文献   

12.
Drug–protein interaction analysis has become a considerable topic in life science which includes clarifying protein functions, explaining drug action mechanisms and uncovering novel drug candidates. This work was to determine the association constants (K A ) of six drugs to β 2‐adrenergic receptor by injection amount‐dependent method using stationary phase containing the immobilized receptor. The values of K A were calculated to be (25.85 ± 0.035) × 104 m −1 for clorprenaline, (42.51 ± 0.054) × 104 m −1 for clenbuterol, (6.67 ± 0.008) × 104 m −1 for terbutaline, (33.99 ± 0.025) × 104 m −1 for tulobuterol, (7.59 ± 0.011) × 104 m −1 for salbutamol and (78.52 ± 0.087) × 104 m −1 for bambuterol. This rank order agreed well with the data determined by zonal elution, frontal analysis and nonlinear chromatography, even using different batches of β 2‐AR column. A good correlation was found between the association constants by the current method and radio‐ligand binding assay. Our data indicates that the injection amount‐dependent method is a powerful alternative for rapid analysis of ligand–receptor interactions.  相似文献   

13.
A biosensor for phosphate determination with the flow-injection system was developed using rhodium nanoparticles modified Poly(pyrrole-co-[1-(2-aminophenyl) pyrrole])/pyruvate oxidase. The biosensor showed a very wide linearity up to 70 mM phosphate concentration compared to previously reports, response time of 4 s., operational stability with a relative standard deviation of 0.009 % and accuracy of 99.4 %±0.949 at a flow rate of 2.0 Ml min.−1 at exactly −0.68 V. Detection limit were calculated to be 21±0.001 μM by preserving 81.1 % of its initial response at the end of 16th days. Artificial urine was analyzed without dilution to investigate biosensor performance.  相似文献   

14.
Surface regulation is an effective strategy to improve the performance of catalysts, but it has been rarely demonstrated for nitrogen reduction reaction (NRR) to date. Now, surface-rough Rh2Sb nanorod (RNR) and surface-smooth Rh2Sb NR (SNR) were selectively created, and their performance for NRR was investigated. The high-index-facet bounded Rh2Sb RNRs/C exhibit a high NH3 yield rate of 228.85±12.96 μg h−1 mg−1Rh at −0.45 V versus reversible hydrogen electrode (RHE), outperforming the Rh2Sb SNRs/C (63.07±4.45 μg h−1 mg−1Rh) and Rh nanoparticles/C (22.82±1.49 μg h−1 mg−1Rh), owing to the enhanced adsorption and activation of N2 on high-index facets. Rh2Sb RNRs/C also show durable stability with negligible activity decay after 10 h of successive electrolysis. The present work demonstrates that surface regulation plays an important role in promoting NRR activity and provides a new strategy for creating efficient NRR electrocatalysts.  相似文献   

15.
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with −81.7 ± 1.7 (r2 = 0.9986) and −146.2 ± 2.3 mV/decade (r2 = 0.9991) slopes over the linearity range 1.5 μM–1.5 mM with 0.8 and 1.0 μM detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)6]−3/−4 redox-active electrolyte. Sensors achieved detection limits of 4.3 × 10−8 and 1.8 × 10−7 M over the linear ranges of 5.2×10−8–1.0×10−4 M and 1.4×10−6–1.4×10−3 M, with 0.09 ± 0.004 and 0.168 ± 0.009 log Ω/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.  相似文献   

16.
《Electroanalysis》2017,29(9):2114-2124
A novel and sensitive amperometric biosensor for L‐lysine determination based on a glassy carbon electrode (GCE) modified with graphene (GR) and redox polymer poly(vinylferrocene) (PVF) was constructed. L‐lysine‐α‐oxidase was immobilized onto the modified GCE by a glutaraldehyde/bovine serum albumin cross‐linking procedure. SEM, CV and EIS were used for the characterization of the surface morphology and stepwise fabrication processes of PVF/GR composite. Optimal composition of the biosensor and experimental conditions that affect the performance of the biosensor are discussed. The effect of buffer pH on biosensor response was studied in detail over a wide pH range. L‐lysine biosensor displayed a linear range of 9.9×10−7 ‐ 3.1×10−4 M with a low detection limit of 2.3×10−7 M and KM app value of 0.4 mM. The L‐lysine biosensor was tested using pharmaceutical sample and cheese with satisfactory results.  相似文献   

17.

We describe the electrochemical preparation of bismuth nanoribbons (Bi-NRs) with an average length of 100 ± 50 nm and a width of 10 ± 5 μm by a potentiostatic method. The process occurs on the surface of a glassy carbon electrode (GCE) in the presence of disodium ethylene diamine tetraacetate that acts as a scaffold for the growth of the Bi-NRs and also renders them more stable. The method was applied to the preparation of Bi-NRs incorporated into reduced graphene oxide. This nanocomposite was loaded with the enzyme glucose oxidase onto a glassy carbon electrode. The resulting biosensor displays an enhanced redox peak for the enzyme with a peak-to-peak separation of about 28 mV, revealing a fast electron transfer at the modified electrode. The loading of the GCE with electroactive GOx was calculated to be 8.54 × 10−10 mol∙cm−2, and the electron transfer rate constant is 4.40 s−1. Glucose can be determined (in the presence of oxygen) at a relatively working potential of −0.46 V (vs. Ag|AgCl) in the 0.5 to 6 mM concentration range, with a 104 μM lower detection limit. The sensor also displays appreciable repeatability, reproducibility and remarkable stability. It was successfully applied to the determination of glucose in human serum samples.

A potentiostatic method was used to prepare reduced graphene oxide and bismuth nanoribbons nanocomposite on a glassy carbon electrode. This nanocomposite was loaded with enzyme glucose oxidase to fabricate a glucose biosensor.

  相似文献   

18.
Chemical sensors relying on graphene-based materials have been widely used for electrochemical determination of metal ions and have demonstrated excellent signal amplification. This study reports an electrochemically reduced graphene oxide (ERGO)/mercury film (HgF) nanocomposite-modified pencil graphite electrode (PGE) prepared through successive electrochemical reduction of graphene oxide (GO) sheets and an in situ plated HgF. The ERGO-PG-HgFE, in combination with dimethylglyoxime (DMG) and square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV), was evaluated for the determination of Ni2+ in tap and natural river water samples. A single-step electrode pre-concentration approach was employed for the in situ Hg-film electroplating, metal-chelate complex formation, and non-electrolytic adsorption at –0.7 V. The current response due to nickel-dimethylglyoxime [Ni(II)-DMG2] complex reduction was studied as a function of experimental paratmeters including the accumulation potential, accumulation time, rotation speed, frequency and amplitude, and carefully optimized for the determination of Ni2+ at low concentration levels (μg?L?1) in pH 9.4 of 0.1 M NH3–NH4Cl buffer. The reduction peak currents were linear with the Ni2+ concentration between 2 and 16?μg?L?1. The limits of detection and quantitation were 0.120?±?0.002?µg?L?1 and 0.401?±?0.007?µg?L?1 respectively, for the determination of Ni2+ at an accumulation time of 120?s. The ERGO-PG-HgFE further demonstrated a highly selective stripping response toward Ni2+ determination compared to Co2+. The electrode was found to be sufficiently sensitive to determine metal ions in water samples at 0.1?µg?L?1, well below the World Health Organization standards.  相似文献   

19.
A laser photolysis–long path laser absorption (LP‐LPLA) experiment has been used to determine the rate constants for H‐atom abstraction reactions of the dichloride radical anion (Cl2) in aqueous solution. From direct measurements of the decay of Cl2 in the presence of different reactants at pH = 4 and I = 0.1 M the following rate constants at T = 298 K were derived: methanol, (5.1 ± 0.3)·104 M−1 s−1; ethanol, (1.2 ± 0.2)·105 M−1 s−1; 1‐propanol, (1.01 ± 0.07)·105 M−1 s−1; 2‐propanol, (1.9 ± 0.3)·105 M−1 s−1; tert.‐butanol, (2.6 ± 0.5)·104 M−1 s−1; formaldehyde, (3.6 ± 0.5)·104 M−1 s−1; diethylether, (4.0 ± 0.2)·105 M−1 s−1; methyl‐tert.‐butylether, (7 ± 1)·104 M−1 s−1; tetrahydrofuran, (4.8 ± 0.6)·105 M−1 s−1; acetone, (1.41 ± 0.09)·103 M−1 s−1. For the reactions of Cl2 with formic acid and acetic acid rate constants of (8.0 ± 1.4)·104 M−1 s−1 (pH = 0, I = 1.1 M and T = 298 K) and (1.5 ± 0.8) · 103 M−1 s−1 (pH = 0.42, I = 0.48 M and T = 298 K), respectively, were derived. A correlation between the rate constants at T = 298 K for all oxygenated hydrocarbons and the bond dissociation energy (BDE) of the weakest C‐H‐bond of log k2nd = (32.9 ± 8.9) − (0.073 ± 0.022)·BDE/kJ mol−1 is derived. From temperature‐dependent measurements the following Arrhenius expressions were derived: k (Cl2 + HCOOH) = (2.00 ± 0.05)·1010·exp(−(4500 ± 200) K/T) M−1 s−1, Ea = (37 ± 2) kJ mol−1 k (Cl2 + CH3COOH) = (2.7 ± 0.5)·1010·exp(−(4900 ± 1300) K/T) M−1 s−1, Ea = (41 ± 11) kJ mol−1 k (Cl2 + CH3OH) = (5.1 ± 0.9)·1012·exp(−(5500 ± 1500) K/T) M−1 s−1, Ea = (46 ± 13) kJ mol−1 k (Cl2 + CH2(OH)2) = (7.9 ± 0.7)·1010·exp(−(4400 ± 700) K/T) M−1 s−1, Ea = (36 ± 5) kJ mol−1 Finally, in measurements at different ionic strengths (I) a decrease of the rate constant with increasing I has been observed in the reactions of Cl2 with methanol and hydrated formaldehyde. © 1999 John Wiley & Sons, Inc. Int J Chem Kinet 31: 169–181, 1999  相似文献   

20.
《Electroanalysis》2017,29(10):2300-2306
High‐performance biosensors were fabricated by efficiently transferring enzyme onto Pt electrode surfaces using a polydimethylsiloxane (PDMS) stamp. Polypyrrole and Nafion were coated first on the electrode surface to act as permselective films for exclusion of both anionic and cationic electrooxidizable interfering compounds. A chitosan film then was electrochemically deposited to serve as an adhesive layer for enzyme immobilization. Glucose oxidase (GOx) was selected as a model enzyme for construction of a glucose biosensor, and a mixture of GOx and bovine serum albumin was stamped onto the chitosan‐coated surface and subsequently crosslinked using glutaraldehyde vapor. For the optimized fabrication process, the biosensor exhibited excellent performance characteristics including a linear range up to 2 mM with sensitivity of 29.4±1.3 μA mM−1 cm−2 and detection limit of 4.3±1.7 μM (S/N=3) as well as a rapid response time of ∼2 s. In comparison to those previously described, this glucose biosensor exhibits an excellent combination of high sensitivity, low detection limit, rapid response time, and good selectivity. Thus, these results support the use of PDMS stamping as an effective enzyme deposition method for electroenzymatic biosensor fabrication, which may prove especially useful for the deposition of enzyme at selected sites on microelectrode array microprobes of the kind used for neuroscience research in vivo .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号