首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An amperometric cholesterol biosensor based on immobilization of cholesterol oxidase in a Prussian blue (PB)/polypyrrole (PPy) composite film on the surface of a glassy carbon electrode was fabricated. Hydrogen peroxide produced by the enzymatic reaction was catalytically reduced on the PB film electrode at 0 V with a sensitivity of 39 μA (mol/L)?1. Cholesterol in the concentration range of 10?5 ? 10?4 mol/L was determined with a detection limit of 6 × 10?7 mol/L by amperometric method. Normal coexisting compounds in the bio‐samples such as ascorbic acid and uric acid do not interfere with the determination. The excellent properties of the sensor in sensitivity and selectivity are attributed to the PB/PPy layer modified on the sensor.  相似文献   

2.
聚吡咯固定胆固醇氧化酶/普鲁士蓝安培传感器的研制   总被引:3,自引:0,他引:3  
李建平  彭图治 《分析化学》2003,31(6):669-673
利用电聚合吡咯的方法将胆固醇氧化酶固定在普鲁士蓝 (PB)修饰玻碳电极表面 ,制成了一种新型胆固醇安培传感器。PB膜修饰电极催化过氧化氢电还原 ,于 0V(vs.Ag ACl)产生灵敏还原峰 ,利用安培法可对胆固醇进行间接测定。胆固醇的测定范围为 0~ 2× 10 - 4mol L ,检出限为 6× 10 - 7mol L ,灵敏度较当前胆固醇传感器有明显的提高。同时该传感器对胆固醇的测定避免了常规电化学传感器测定中样品所含大量的易氧化物质带来的干扰  相似文献   

3.
高灵敏度双介体基胆固醇生物传感器的研制   总被引:1,自引:0,他引:1  
研制了一种高灵敏度、高准确性、微小取样(-滴血,V≥25μL)并可快速测量(≤60s)的实用型夹心式胆固醇生物传感器。它是由双介体、三酶生化氧还体系构成的电流型传感器。其中,第一介体含于敏感电极石墨电导层内,第二介体及三种酶、相试剂含于试剂纤维层中。本传感器可用来直接测量从正常人到异常人的血胆固醇含量(2~10mmol/L),并将实现商品化。  相似文献   

4.
本文用Ferrocene(FC)作为黄嘌呤氧化酶与电极之间的电子传递体,通过牛血清白蛋白和戊二醛交联剂,把黄嘌呤氧化酶固定在Nafion-Fc修饰电极表面,制备成次黄嘌呤传感器。该传感器的线性范围为5.0×10-5—7.5×10-4mol/L,响应时间小于7os。  相似文献   

5.
A sensitive amperometric glucose biosensor based on platinum nanoparticles (PtNPs) combined aligned carbon nanotubes (ACNTs) electrode was investigated. PtNPs which can enhance the electrocatalytic activity of the electrode for electrooxidating hydrogen peroxide by enzymatic reaction were electrocrystallized on 4‐aminobenzene monolayer‐grafted ACNTs electrode by potential‐step method. These PtNPs combined ACNTs' (PtNPs/ACNTs) surfaces were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The highly dispersed PtNPs on ACNTs can be obtained. The enzyme electrode exhibits excellent response performance to glucose with linear range from 1×10?5–7×10?3 mol L?1 and fast response time within 5 s. Furthermore, this glucose biosensor also has good reproducibility. It is demonstrated that the PtNPs/ACNTs electrode with high electrocatalytic activity is a suitable basic electrode for preparing enzyme electrodes.  相似文献   

6.
A hydrogen peroxide (H2O2) biosensor based on the combination of Au@Ag core‐shell nanoparticles with a hemoglobin‐chitosan‐1‐butyl‐3‐methyl‐imidazolium tetrafluoroborate (Hb‐CHIT‐BMIM×BF4) composite film was prepared. UV‐vis spectroscopy and transmission electron microscopy confirmed a core‐shell nanostructure of Au@Ag nanoparticle was successfully obtained. Cyclic voltammetric results showed a pair of well‐defined redox peaks appeared with the formal potential (EO′) of ‐0.301 V (versus Ag/AgCl reference electrode) and the peak‐to‐peak separation (ΔEp) was 84 mV in 0.1 M phosphate buffer solutions. Due to the synergetic effect of Au@Ag core‐shell nanoparticles and Hb‐CHIT‐BMIM×BF4, the biosensor exhibited good electrocatalytic activity to the reduction of H2O2 in a linear range from 1.0 × 10?6 to 1.0 × 10?3 M with a detection limit of 4 × 10?7 M (S/N = 3). The apparent Michaelis‐Menten constant (KM) was estimated to be 4.4 × 10?4 M, showing its high affinity. Thus, the study proved that the combination of Au@Ag core‐shell nanoparticles and Hb‐CHIT‐BMIM×BF4 is able to open up new opportunities for the design of enzymatic biosensors.  相似文献   

7.
The interactions of furazolidone (Fu) with double‐stranded calf thymus DNA (dsDNA) on the multi‐walled carbon nanotubes‐ionic liquid‐modified carbon paste electrode (MWCNT‐IL‐CPE) have been studied by cyclic voltammetry. In the presence of DNA, the cathodic peak current of Fu decreased and the peak potential shifted to a positive potential, indicating the intercalative interaction of Fu with DNA. The binding constant of Fu with DNA and stoichiometric coefficient has been determined according to the Hill's model. This electrochemical method was further applied to the determination of DNA. Two linear calibration curves were obtained for DNA detection in the concentration ranges of 0.03–0.10 and 0.10–4.0 μg l?1 with a detection limit of 0.027 μg l?1. The method was successfully applied to analyze Fu in serum samples.  相似文献   

8.
《Electroanalysis》2005,17(10):857-861
The carbon nanotubes decorated nanoplatinum (CNT‐Pt) were prepared using a chemical reduction method and a novel base electrode was constructed by intercalating CNT‐Pt on the surface of a waxed graphite electrode. The results showed that the nano‐particles of platinum at a waxed graphite electrode exhibits high catalytic activity for the reduction of hydrogen peroxide. The cholesterol oxidase (ChOx), chosen as a model enzyme, was immobilized with sol‐gel on the CNT‐Pt base electrode to construct a biosensor. The current response of the biosensor for cholesterol was very rapid (<20 s). The linear range for cholesterol measurement was 4.0×10?6 mol/L ?1.0×10?4 mol/L with a detection limit of 1.4×10?6 mol/L. The experiments also showed that the ChOx/sol‐gel/CNT‐Pt biosensor was sensitive and stable in detecting cholesterol in serum samples.  相似文献   

9.
《Electroanalysis》2018,30(3):543-550
Electrochemical sensors have been developed by modifying a glassy carbon electrode with organo‐kaolinite hybrid materials. These materials were obtained by the grafting of four ionic liquids (1‐(2‐hydroxyethyl)‐4‐benzylpyridinium chloride, 1‐(2‐hydroxyethyl)‐4‐(tert‐butyl)pyridinium chloride, 1‐(2‐hydroxyethyl)‐4‐ethylpyridinium chloride and 1‐(2‐hydroxyethyl)‐4‐methylpyridinium chloride) on the interlayer aluminol surfaces of kaolinite. With the presence of ionic liquids in the interlayer space of kaolinite, the hybrid materials acquired anion exchange properties and were successfully applied as electrode modifier for the electroanalysis of thiocyanate (SCN), an anion of medical and environmental concern. A pre‐concentration/detection strategy was used to overcome the interfering effect of the electrolytic solution. After the optimisation of some key experimental parameters (sodium nitrate as electrolyte, 5 min of accumulation time) calibration curves were plotted. Excellent linearity was obtained in the low concentration region (1×10−6 M to 4×10−5 M). The lowest detection limit (15 nM) was obtained with the benzylpyridinium functionalized kaolinite and the highest (60 nM) with the methylpyridinium functionalized kaolinite. Interfering anions (NO3, Cl, SO42− and CH3COO) present in the pre‐concentration solution were found to interfere with SCN but the sensors remained stable and produced reproducible signals. The most sensitive sensor was successfully applied for the amperometric determination of SCN in human saliva samples.  相似文献   

10.
《Electroanalysis》2003,15(3):219-224
A novel hydrogen peroxide biosensor has been constructed based on the characteristics of the carbon nanotube. The multiwall carbon nanotube (MWNT) was used as a coimmobilization matrix to incorporate horseradish peroxidase (HRP) and electron transfer mediator methylene blue (MB) onto a glassy carbon electrode surface. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of methylene blue as an electron carrier between the immobilized peroxidase and the surface of glassy carbon electrode. The amperometric response of this resulting biosensor to H2O2 shows a linear relation in the range from 4 μM to 2 mM. The detection limit was 1 μM when the signal to noise ratio is 3. The presence of dopamine and ascorbic acid hardly affects the sensitive determination of H2O2. This biosensor also possesses very good stability and reproducibility.  相似文献   

11.
Nafion—四硫富瓦烯修饰蜡浸石墨电极的葡萄糖传感器   总被引:2,自引:0,他引:2  
刘海鹰  李辉 《分析化学》1994,22(9):882-886
本文用四硫富瓦烯(TTF)作为酶与电极之间的电子传递体,通过牛血清蛋白和戊二醛交联剂,把葡萄糖化氧化酶固定在Nafion-TTF修饰石墨电极上,最后在电极修饰一层Nafion膜,制备成葡萄糖传感器。Nafion膜不仅能防止四硫富瓦燃流失,而且能氢抗坏血酸,尿酸等电活生物质阻挡在电极外,防止其干扰,同时具有防污性能。通过实验表明TTF^+,TTT^2^+都能够氧化葡萄糖氧化酶中的辅酶(FADH2)。  相似文献   

12.
A new electrochemical biosensor was constructed by immobilization of hemoglobin (Hb) on a DNA modified carbon ionic liquid electrode (CILE), which was prepared by using 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) as the modifier. UV‐vis absorption spectroscopic result indicated that Hb remained its native conformation in the composite film. The fabricated Nafion/Hb/DNA/CILE was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A pair of well‐defined redox peaks was obtained on the modified electrode, indicated that the Nafion and DNA composite film provided an excellent biocompatible microenvironment for keeping the native structure of Hb and promoting the direct electron transfer rate of Hb with the basal electrode. The electrochemical parameters of Hb in the composite film were further calculated with the results of the charge transfer coefficient (α) and the apparent heterogeneous electron transfer rate constant (ks) as 0.41 and 0.31 s?1. The proposed electrochemical biosensor showed good electrocatalytic response to the reduction of trichloroacetic acid (TCA), H2O2, NO and the apparent Michaelis–Menten constant (KMapp) for the electrocatalytic reaction was calculated, respectively.  相似文献   

13.
A carbon paste electrode was modified with 2‐(4‐Oxo‐3‐phenyl‐3,4‐dihydroquinazolinyl)‐N′‐phenyl‐hydrazinecarbothioamide, magnetic core? shell Fe3O4@SiO2/MWCNT nanocomposite and ionic liquid (n‐hexyl‐3‐methylimidazolium hexafluoro phosphate). The electro‐oxidation of hydrazine at the surface of the modified electrode was studied using electrochemical approaches. This modified electrode offers a considerable improvement in voltammetric sensitivity toward hydrazine, compared to the bare electrode. Square wave voltammetry (SWV) exhibits a linear dynamic range from 7.0×10?8 to 5.0×10?4 M and a detection limit of 40.0 nM for hydrazine. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for hydrazine oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of hydrazine and phenol that makes it suitable for the detection of hydrazine in the presence of phenol in real samples.  相似文献   

14.
制作了碳纳米管和碳纳米管负载铂镶嵌修饰的浸蜡石墨电极,实验发现纳米铂的引入使修饰电极对过氧化氢的还原有更好的电催化性能。用溶胶凝胶法将胆固醇氧化酶固定在碳纳米管负载铂修饰的浸蜡石墨电极表面,构建了一种新型的胆固醇生物传感器。实现了低电位下对胆固醇的间接测定。胆固醇浓度在4.0×10-6~1×10-4mol/L范围内与其峰电流的增量呈现良好的线性关系。检出限为1.4×10-6mol/L。该传感器的灵敏度高,选择性好,可以避免样品中大量易氧化物质的干扰,且寿命长,性能稳定。  相似文献   

15.
《Electroanalysis》2004,16(23):1992-1998
A carbon nanotubes‐based amperometric cholesterol biosensor has been fabricated through layer‐by‐layer (LBL) deposition of a cationic polyelectrolyte (PDDA, poly(diallyldimethylammonium chloride)) and cholesterol oxidase (ChOx) on multi‐walled carbon nanotubes (MWNTs)‐modified gold electrode, followed by electrochemical generation of a nonconducting poly(o‐phenylenediamine) (PPD) film as the protective coating. Electrochemical impedance measurements have shown that PDDA/ChOx multilayer film could be formed uniformly on MWNTs‐modified gold electrode. Due to the strong electrocatalytic properties of MWNTs toward H2O2 and the low permeability of PPD film for electroacitve species, such as ascorbic acid, uric acid and acetaminophen, the biosensor has shown high sensitivity and good anti‐interferent ability in the detection of cholesterol. The effect of the pH value of the detection solution on the response of the biosensor was also investigated. A linear range up to 6.0 mM has been observed for the biosensor with a detection limit of 0.2 mM. The apparent Michaelis‐Menten constant and the maximum response current density were calculated to be 7.17 mM and 7.32 μA cm?2, respectively.  相似文献   

16.
Electroanalysis of benazepril HCl was successful using a carbon paste electrode modified with an ionic liquid crystal ( 1‐butyl‐1‐methylpiperidinium hexafluorophosphate) in presence of sodium dodecyl sulfate. The electrode performance was compared to ionic liquids (1‐n‐hexyl‐3‐methyl imidazolium tetrafluoroborate and 1‐butyl‐4‐methyl pyridinium tetrafluoroborate). Electrochemical determination of benazepril HCl was in the linear dynamic range of 8.89×10?7 to 1.77×10?5 mol L?1 (correlation coefficient 0.999) and LOD 7.17×10?9 mol L?1. benazepril HCl was determined using this sensor in presence of urine metabolites such as uric acid, ascorbic acid. Binary mixtures of dopamine/benazepril and amlodipine/benazepril were also determined successfully.  相似文献   

17.
《Electroanalysis》2003,15(12):1031-1037
A cholesterol biosensors fabricated by immobilization of cholesterol oxidase (ChOx) in a layer of silicic sol‐gel matrix on the top of a Prussian Blue‐modified glassy carbon electrode was prepared. It is based on the detection of hydrogen peroxide produced by ChOx at ?0.05 V. The half‐lifetime of the biosensor is about 35 days. Cholesterol can be determined in the concentration range of 1×10?6?8×10?5 mol/L with a detection limit of 1.2×10?7 mol/L. Normal interfering compounds, such as ascorbic acid and uric acid do not affect the determination. The high sensitivity and outstanding selectivity are attributed to the Prussian Blue film modified on the sensor.  相似文献   

18.
将合成的立方体纳米氧化亚铜用于修饰玻碳电极,在其上固定葡萄糖氧化酶,构建了高灵敏的安培型葡萄糖生物传感器.采用X射线衍射(X RD)、扫描电镜(SEM)对合成的立方体纳米氧化亚铜及其修饰电极进行了表征.结果表明,合成的纳米氧化亚铜为均匀的立方体形状.采用循环伏安法(CV)、交流阻抗谱(EIS)、差分脉冲伏安法(DPV)及计时电流法(CA)考察了修饰电极的电化学行为.在含0.1 mmol/L葡萄糖的磷酸盐缓冲溶液(pH 7.4)中研究了立方体纳米氧化亚铜修饰电极的循环伏安(CV)响应,实验结果表明,此修饰电极对葡萄糖显示出良好的电催化性能.DPV响应电流与葡萄糖的浓度在5.0×10-6 ~4.0× 10-3mol/L范围内呈良好的线性关系,线性相关系数R2=0.9983,检出限为6.8×10-7 mol/L(S/N=3).CA实验结果表明,尿酸、抗坏血酸、D-果糖对传感器不产生干扰.本传感器具有较好的重现性和稳定性,可用于实际样品中葡萄糖的检测.  相似文献   

19.
在碳纳米管(CNTs)和K3Fe(CN)6修饰的铂电极上吸附固定胆碱氧化酶,以鲁米诺为发光试剂,研制了胆碱电化学发光(ECL)生物传感器。CNTs可有效提高电极表面的电荷传输能力、提高电极表面的生物相容性和对酶分子的固载能力;K3Fe(CN)6对酶活性具有激活作用,同时对H2O2增敏的鲁米诺ECL有增强作用,均有利于提高传感器的检测灵敏度。研究表明,将CNTs分散液与K3Fe(CN)6混合,滴涂修饰在Pt电极上,吸附固定胆碱氧化酶,制备传感器。此传感器在含有8×10-6mol/L鲁米诺的磷酸盐缓冲液(pH7.4)、30℃条件下产生的ECL强度与胆碱浓度在1×10-7~4×10-3mol/L范围内呈线性关系,相关系数为0.994,检出限为1.2×10-8 mol/L。此生物传感器应用于鼠血样中胆碱的测定,测得结果为2.68 mg/L,平均回收率为101.1%。传感器具有快速、稳定和重现性好等特点,有望应用于常规分析。  相似文献   

20.
Multiwall carbon nanotubes (CNTs)‐modified electrode has been prepared by using ionic liquid (IL) as the binder. The as‐prepared CNTs‐IL composite modified electrode has good biocompatibility and is a suitable matrix to immobilize biomolecules. Glucose oxidase (GOx), containing flavin adenine dinucleotide as active site, stably adsorbed on modified electrode surface has resulted in the direct electron transfer. The electron transfer rate of 9.08 s?1 obtained is much higher than that of GOx adsorbed on the CNTs papers (1.7 s?1), and the process is more reversible with small redox peak separation of 23 mV. This may be due to the synergetic promotion of CNTs and IL to electron transfer of the protein, especially the IL as the binder, showing better electrochemical properties than that of chitosan and Nafion. Furthermore, GOx adsorbed at the modified electrode exhibits good stability and keeps good electrocatalytic activity to glucose with broad linear range up to 20 mM. Besides, the simple preparation procedure and easy renewability make the system a basis to investigate the electron transfer kinetics and biocatalytic performance of GOx and provide a promising platform for the development of biosensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号