首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Elastic nature of the viscoelastic fluids induces lateral migration of particles into a single streamline and can be used by microfluidic based flow cytometry devices. In this study, we investigated focusing efficiency of polyethylene oxide based viscoelastic solutions at varying ionic concentration to demonstrate their use in impedimetric particle characterization systems. Rheological properties of the viscoelastic fluid and particle focusing performance are not affected by ionic concentration. We investigated the viscoelastic focusing dynamics using polystyrene (PS) beads and human red blood cells (RBCs) suspended in the viscoelastic fluid. Elasto‐inertial focusing of PS beads was achieved with the combination of inertial and viscoelastic effects. RBCs were aligned along the channel centerline in parachute shape which yielded consistent impedimetric signals. We compared our impedance‐based microfluidic flow cytometry results for RBCs and PS beads by analyzing particle transit time and peak amplitude at varying viscoelastic focusing conditions obtained at different flow rates. We showed that single orientation, single train focusing of nonspherical RBCs can be achieved with polyethylene oxide based viscoelastic solution that has been shown to be a good candidate as a carrier fluid for impedance cytometry.  相似文献   

2.
Nan Xiang  Silin Wang  Zhonghua Ni 《Electrophoresis》2021,42(21-22):2256-2263
Elastic-inertial focusing has attracted increasing interest in recent years due to the three-dimensional (3D) single-train focusing ability it offers. However, multi-train focusing, instead of single-train focusing, was observed in viscoelastic fluids with low elasticity as a result of the competition between inertia effect and viscoelasticity effect. To address this issue, we employed the secondary flow to facilitate single-train elastic-inertial focusing in low elasticity viscoelastic fluids. A three-section contraction-expansion channel was designed to induce the secondary flow to pinch the multiplex focusing trains into a single one exactly at the channel centerline. After demonstrating the focusing process and mechanism in our device, we systematically explored and discussed the effects of particle diameter, operational flow rate, polymer concentration, and channel dimension on particle focusing performances. Our device enables single-train focusing of particles in viscoelastic fluids with low elasticity, and offers advantages of planar single-layer structure, and sheathless, external-field free operation.  相似文献   

3.
Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 μm polystyrene particles, 5 μm polystyrene particles, 5 μm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.  相似文献   

4.
Yang S  Kim JY  Lee SJ  Lee SS  Kim JM 《Lab on a chip》2011,11(2):266-273
Particle focusing in planar geometries is essentially required in order to develop cost-effective lab-on-a-chips, such as cell counting and point-of-care (POC) devices. In this study, a novel method for sheathless particle focusing, called "Elasto-Inertial Particle Focusing", was demonstrated in a straight microchannel. The particles were notably aligned along the centerline of the straight channel under a pressure-driven flow without any additional external force or apparatus after the addition of an elasticity enhancer: PEO (poly(ethylene oxide)) (~O(100) ppm). As theoretically predicted (elasticity number: El≈O(100)), multiple equilibrium positions (centerline and corners) were observed for the viscoelastic flow without inertia, whereas three-dimensional particle focusing only occurred when neither the elasticity nor the inertia was negligible. Therefore, the three-dimensional particle focusing mechanism was attributed to the synergetic combination of the elasticity and the inertia (elasticity number: El≈O(1-10)). Furthermore, from the size dependence of the elastic force upon particles, we demonstrated that a mixture of 5.9 and 2.4 μm particles was separated at the exit of the channel in viscoelastic flows. We expect that this method can contribute to develop the miniaturized flow cytometry and microdevices for cell and particle manipulation.  相似文献   

5.
JY Kim  SW Ahn  SS Lee  JM Kim 《Lab on a chip》2012,12(16):2807-2814
Much difficulty has been encountered in manipulating small-scale materials, such as submicron colloidal particles and macromolecules (e.g., DNA and proteins), in microfluidic devices since diffusion processes due to thermal (Brownian) motion become more pronounced with decreasing particle size. Here, we present a novel approach for the continuous focusing of such small-scale materials. First, we successfully focused fluorescent submicron polystyrene (PS) beads along equilibrium positions in microchannels through the addition of a small amount water-soluble polymer [500 ppm poly(ethylene oxide) (PEO)]. Lateral migration velocity significantly depends upon the viscoelastic effect (Weissenberg number: Wi) and the aspect ratio of particle size to channel height (a/h). Interestingly, focusing using viscoelastic flows was also observed for flexible DNA molecules (λ-DNA and T4-DNA), which have radii of gyration (R(g)) of approximately 0.69 μm and 1.5 μm, respectively. This small-scale material manipulation using medium viscoelasticity will contribute to the design of nanoparticle separation and genomic mapping devices.  相似文献   

6.
We perform 3D numerical simulations, heuristic modeling and microfluidic experiments to demonstrate, for the first time, the presence of a bistability scenario for transversal migration of particles suspended in a viscoelastic liquid flowing in a pipe. Our results show that particle migration, either at the centerline or at the wall, can be controlled by the rheological properties of the suspending liquid and by the relative dimensions of the particle and tube. Proper selection of these parameters can promote strict aligning of particles on a line, i.e., 3-D focusing. Simple design rules are given to rationally control particle focusing under flow in micropipes.  相似文献   

7.
Insulator-based dielectrophoretic (iDEP) microdevices have been limited to work with Newtonian fluids. We report an experimental study of the fluid rheological effects on iDEP focusing and trapping of polystyrene particles in polyethylene oxide, xanthan gum, and polyacrylamide solutions through a constricted microchannel. Particle focusing and trapping in the mildly viscoelastic polyethylene oxide solution are slightly weaker than in the Newtonian buffer. They are, however, significantly improved in the strongly viscoelastic and shear thinning polyacrylamide solution. These observed particle focusing behaviors exhibit a similar trend with respect to electric field, consistent with a revised theoretical analysis for iDEP focusing in non-Newtonian fluids. No apparent focusing of particles is achieved in the xanthan gum solution, though the iDEP trapping can take place under a much larger electric field than the other fluids. This is attributed to the strong shear thinning-induced influences on both the electroosmotic flow and electrokinetic/dielectrophoretic motions.  相似文献   

8.
In this review, we focus on recent experimental research involving active colloidal particles of non-biological origin evolving in non-Newtonian fluids. This includes self-propelling active particles and particles driven by external fields. We present different propulsion strategies that are either enabled, or strongly modified, by the presence of a complex medium. This paves the way for novel mechanisms of active transport in biofluids or in other non-Newnotian fluids. When considering the medium, we differentiate between disordered complex fluids, such as diluted polymer solutions, and liquid crystals. While the latter are also viscoelastic fluids, the ability to control their molecular orientation results in distinct colloidal driving and steering mechanisms, and enables new types of active soft matter in the form of active quasi-particles.  相似文献   

9.
Lim EJ  Ober TJ  Edd JF  McKinley GH  Toner M 《Lab on a chip》2012,12(12):2199-2210
Inertial microfluidics has demonstrated the potential to provide a rich range of capabilities to manipulate biological fluids and particles to address various challenges in biomedical science and clinical medicine. Various microchannel geometries have been used to study the inertial focusing behavior of particles suspended in simple buffer solutions or in highly diluted blood. One aspect of inertial focusing that has not been studied is how particles suspended in whole or minimally diluted blood respond to inertial forces in microchannels. The utility of imaging techniques (i.e., high-speed bright-field imaging and long exposure fluorescence (streak) imaging) primarily used to observe particle focusing in microchannels is limited in complex fluids such as whole blood due to interference from the large numbers of red blood cells (RBCs). In this study, we used particle trajectory analysis (PTA) to observe the inertial focusing behavior of polystyrene beads, white blood cells, and PC-3 prostate cancer cells in physiological saline and blood. Identification of in-focus (fluorescently labeled) particles was achieved at mean particle velocities of up to 1.85 m s(-1). Quantitative measurements of in-focus particles were used to construct intensity maps of particle frequency in the channel cross-section and scatter plots of particle centroid coordinates vs. particle diameter. PC-3 cells spiked into whole blood (HCT = 45%) demonstrated a novel focusing mode not observed in physiological saline or diluted blood. PTA can be used as an experimental frame of reference for understanding the physical basis of inertial lift forces in whole blood and discover inertial focusing modes that can be used to enable particle separation in whole blood.  相似文献   

10.
《Comptes Rendus Chimie》2003,6(11-12):1411-1416
The rheological behaviour of butyl acrylate/styrene/acrylic acid latices thickened with a hydrophobically modified ethoxylated polyurethane (HEUR) or hydrophobically modified alkali-soluble polyacrylate emulsion (HASE) was investigated. While the pseudoplastic character of frequency dependence of complex viscosity was similar for both thickeners, viscoelastic behaviour, expressed as the ratio of loss and storage moduli, significantly differed, indicating that the HEUR molecules, unlike swollen HASE particles, create a viscoelastic space structure. The increase in hydrophilicity of the particle surface, achieved by incorporation of 2-hydroxyethyl methacrylate (HEMA) monomer into the latex copolymer reduced the viscoelasticity of latices thickened with HEUR, but not of those thickened with HASE. This confirms that adsorption of hydrophobic end-groups on particle surface is important for thickening of latices with HEUR and that a physical network of latex particles interconnected by the thickener macromolecules is formed. To cite this article: O. Quadrat et al., C. R. Chimie 6 (2003).  相似文献   

11.
Mucoadhesivity of water-soluble polymers is an important factor, when testing their suitability for controlled drug delivery systems. For this purpose, the interaction of new cationic cellulose polyelectrolytes with lyophilized mucin was investigated by means of turbidimetric titration, microscopy and measurement of zeta potential and particle size changes in the system. Results show that the cellulose derivatives interact with mucin. This interaction became stronger if cellulose macromolecules contained positively charged groups and an electrostatic interaction with the negatively charged mucin particles occurred. Under certain conditions flocculation of mucin particles by the cellulose polyelectrolyte was observed.  相似文献   

12.
Gastrointestinal mucus, a complex network of highly branched glycoproteins and macromolecules, is the first barrier through which orally delivered drug and gene vectors must traverse. The diffusion of such vectors can be restricted by the high adhesivity and viscoelasticity of mucus. In this investigation, the barrier properties of gastrointestinal mucus to particle transport were explored using real‐time multiple particle tracking. The influence of surface chemistry on particle transport rates was examined using amine‐, carboxylate‐, and sulfate‐modified polystyrene nanoparticles. A strong dependence of particle mobility in gastrointestinal mucus on surface charge was observed, with anionic particles diffusing 20–30 times faster than cationic particles. Comparison of diffusion coefficients calculated for gastrointestinal mucus with significantly varying values previously reported in the literature for other mucus sources, including cervicovaginal mucus and cystic fibrosis sputum, highlight the dependence of mucus barrier properties on the anatomical source. A significant degree of transport rate heterogeneity was also observed in native gastrointestinal mucus, suggesting a highly heterogeneous distribution of pore sizes. Furthermore, the suitability of purified mucin as a model system for transport studies was assessed by comparing particle transport rates between native intestinal mucus and purified porcine gastric mucin. Particle transport rates were approximately threefold lower in native mucus compared to purified mucin for anionic particles, yet comparable for cationic particles. Differences between barrier properties of the purified mucin preparation and native mucus depended on specific carrier properties, indicating that the purified mucin preparation does not provide an accurate model system for native mucus.

  相似文献   


13.
The influence of nano‐scale particles on the viscoelastic properties of polymer suspensions is investigated. We have developed a simulation technique for the particle orientation and polymer conformation tensors to study various features of the suspensions. The nano‐particles are modeled as thin rigid oblate spheroid particles and the polymers as FENE‐P type viscoelastic and Newtonian fluid. Both interparticle and polymer‐particle interactions have been taken into account in our numerical computations. The nonlinear viscoelastic properties of nanocomposites of layered silicate particles in non‐Newtonian fluids are examined at the start‐up of shear flow and are interpreted using the model to examine the effects of model parameters as well as flow conditions on particle orientation, viscosity, and first normal stress difference of the suspensions. We have studied the microstructure of polymer‐clay nanocomposites using X‐ray diffraction (XRD) scattering and transmission electron microscopy (TEM). The rheology of these nanocomposites in step‐shear is shown to be fairly well predicted by the model. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 48: 2003–2011, 2010  相似文献   

14.
Xuan X  Li D 《Electrophoresis》2005,26(18):3552-3560
The electrokinetic focusing and the resultant accelerated electrophoretic motion of polystyrene particles and red blood cells were visualized in microfluidic cross-channels. The experimentally measured width of the focused stream and the measured velocity increase of particles and cells at different voltage ratios follow the proposed analytical formula within the experimental error. The attained velocity increase is insensitive to the particle size, particle property (i.e., particle or cell), and particle trajectory. By solving the electrical potential field in the cross-channel at the experimental conditions, we demonstrate that the squeezed electrical field lines in the channel intersection determine the shape of the focused stream, and the nonuniform distribution of axial electrical field strength underlies the variation of particle/cell electrophoretic velocity through the focusing region. However, the dielectrophoretic force resulting from the nonuniform electrical field in the intersection seems to push the acceleration region of particles and cells slightly in the downstream direction. We have also achieved the single particle/cell dispensing by instantly triggering an electrical pulse perpendicular to the focused particulate flow in a double-cross microchannel. The electrokinetic manipulation of particle/cell in microchannels demonstrated in this work can be used for developing integrated lab-on-a-chip devices for studies of cells.  相似文献   

15.
Previous studies have reported a lateral migration in particle electrophoresis through a straight rectangular microchannel. This phenomenon arises from the inherent wall‐induced electrical lift that can be exploited to focus and separate particles for microfluidic applications. Such a dielectrophoretic‐like force has been recently found to vary with the buffer concentration. We demonstrate in this work that the particle zeta potential also has a significant effect on the wall‐induced electrical lift. We perform an experimental study of the lateral migration of equal‐sized polystyrene particles with varying surface charges under identical electrokinetic flow conditions. Surprisingly, an enhanced focusing is observed for particles with a faster electrokinetic motion, which indicates a substantially larger electrical lift for particles with a smaller zeta potential. We speculate this phenomenon may be correlated with the particle surface conduction that is a strong function of particle and fluid properties.  相似文献   

16.
《Electrophoresis》2018,39(2):417-424
Herein, we proposed a strategy for controlling the particle focusing position in Dean‐coupled elasto‐inertial flows via adjusting the polymer concentration of viscoelastic fluids. The physics behind the control strategy was then explored and discussed. At high polymer concentrations, the flowing particles could be single‐line focused exactly at the channel centerline under the dominated elastic force. The center‐line focusing in our spiral channel may employed as a potential pretreatment scheme for microflow cytometry detection. With further decreasing polymer concentrations, the particles would shift into the outer channel region under the comparable competition between inertial lift force, elastic force and Dean drag force. Finally, the observed position‐shifting was successfully employed for particle concentration at a throughput much higher than most existing elasto‐inertial microfluidics.  相似文献   

17.
A novel method is reported to enhance the focusing of microparticle in the viscoelastic fluid. Gradually contracted geometry is designed in microchannel, which changes the distribution of the elastic lift force on the cross section. Additionally, it induces the viscous drag force and the Saffman lift force in the lateral direction. Under the combined effect of these forces, microparticles fast migrate to the center of the channel. In comparison to the channel with constant cross section, the present channel significantly enhances the particle's lateral migration, leading to efficient viscoelastic particle focusing in a short channel length. The influence of flow rate, channel length, particle size and fluid property on the particle focusing is also investigated. With simple structure, small footprint and perfect particle focusing performance, the present device has great potential in the particle focusing processes in various lab-on-a-chip applications.  相似文献   

18.
Surface-enhanced Raman spectroscopy (SERS) is a good candidate for the development of fast and easy-to-use diagnostic tools, possibly used on biofluids in point-of-care or screening tests. In particular, label-free SERS spectra of blood serum and plasma, two biofluids widely used in diagnostics, could be used as a metabolic fingerprinting approach for biomarker discovery. This study aims at a systematic evaluation of SERS spectra of blood serum and plasma, using various Ag and Au aqueous colloids, as SERS substrates, in combination with three excitation lasers of different wavelengths, ranging from the visible to the near-infrared. The analysis of the SERS spectra collected from 20 healthy subjects under a variety of experimental conditions revealed that intense and repeatable spectra are quickly obtained only if proteins are filtered out from samples, and an excitation in the near-infrared is used in combination with Ag colloids. Moreover, common plasma anticoagulants such as EDTA and citrate are found to interfere with SERS spectra; accordingly, filtered serum or heparin plasma are the samples of choice, having identical SERS spectra. Most bands observed in SERS spectra of these biofluids are assigned to uric acid, a metabolite whose blood concentration depends on factors such as sex, age, therapeutic treatments, and various pathological conditions, suggesting that, even when the right experimental conditions are chosen, great care must be taken in designing studies with the purpose of developing diagnostic tests.  相似文献   

19.
The formation of a line of equally spaced particles at the centerline of a microchannel, referred as “particle ordering,” is desired in several microfluidic applications. Recent experiments and simulations highlighted the capability of viscoelastic fluids to form a row of particles characterized by a preferential spacing. When dealing with non-Newtonian fluids in microfluidics, the adherence condition of the liquid at the channel wall may be violated and the liquid can slip over the surface, possibly affecting the ordering efficiency. In this work, we investigate the effect of wall slip on the ordering of particles suspended in a viscoelastic liquid by numerical simulations. The dynamics of a triplet of particles in an infinite cylindrical channel is first addressed by solving the fluid and particle governing equations. The relative velocities computed for the three-particle system are used to predict the dynamics of a train of particles flowing in a long microchannel. The distributions of the interparticle spacing evaluated at different slip coefficients, linear particle concentrations, and distances from the channel inlet show that wall slip slows down the self-assembly mechanism. For strong slipping surfaces, no significant change of the initial microstructure is observed at low particle concentrations, whereas strings of particles in contact form at higher concentrations. The detrimental effect of wall slip on viscoelastic ordering suggests care when designing microdevices, especially in case of hydrophobic surfaces that may enhance the slipping phenomenon.  相似文献   

20.
Park HM  Lee WM 《Lab on a chip》2008,8(7):1163-1170
Many lab-on-a-chip based microsystems process biofluids such as blood and DNA solutions. These fluids are viscoelastic and show extraordinary flow behaviors, not existing in Newtonian fluids. Adopting appropriate constitutive equations these exotic flow behaviors can be modeled and predicted reasonably using various numerical methods. In the present paper, we investigate viscoelastic electroosmotic flows through a rectangular straight microchannel with and without pressure gradient. It is shown that the volumetric flow rates of viscoelastic fluids are significantly different from those of Newtonian fluids under the same external electric field and pressure gradient. Moreover, when pressure gradient is imposed on the microchannel there appear appreciable secondary flows in the viscoelastic fluids, which is never possible for Newtonian laminar flows through straight microchannels. The retarded or enhanced volumetric flow rates and secondary flows affect dispersion of solutes in the microchannel nontrivially.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号