首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
采用直接化学还原法, 以金属钠为还原剂, 四氯乙烯为碳源, 在石蜡油中不经氧化石墨(GO)和氧化石墨烯(GrO)而直接制备石墨烯(Gr), 然后将Pt纳米粒子担载在Gr基体上, 得到Pt/Gr催化剂, 并对其催化氧还原(OR)性能进行了研究. 通过X射线衍射(XRD), 透射电镜(TEM)和电化学测试对合成催化剂的结构、形貌和电化学性质进行了表征. 实验结果表明: 所制备的Pt/Gr催化剂具有较好的分散性, 平均粒径为3.1 nm; 氧还原起始电位比商业JM-Pt/C催化电极正移了24 mV; 交换电流密度达到1×10-3 mA·cm-2, 是商业JM-Pt/C催化电极的2.5倍.  相似文献   

2.
Co3O4/graphene oxide (GO) nanocomposites were successfully prepared by a depositing‐decomposition method. The as‐prepared samples were characterized by scanning electron microscopy (SEM) and Raman spectroscopy. Cyclic voltammetry (CV) was used to evaluate the electrochemical response of a glass carbon electrode (GCE) modified with Co3O4/GO nanocomposite towards glucose. Compared with the Co3O4/GCE, the Co3O4/GO/GCE exihibits higher electrocatalytic activity due to the synergistic effects of electrocatalytic ability of Co3O4 and large surface of GO. The Co3O4/GO/GCE was applied for glucose detection in alkaline solution. The linear current response range of glucose on Co3O4/GO/GCE covered the range from 9 × 10?5 to 6.03 × 10?3 M, with a detection limit of 5.2 × 10?7 M (S/N = 3).  相似文献   

3.
Through layer-by-layer adsorption (LBL) technique, the positively charged multiwalled carbon nanotubes (MWCNTs) and negatively charged graphene multilayer film were formed on graphite-poly(diallyldimethylammoniumchloride)-polystyrenesulphonate (Gr/PDDA/PSS) modified electrode. Due to large surface area and remarkable electrocatalytic properties of MWCNTs and graphene, the Gr/(PDDA/PSS-[MWCNTs-NH 3 + -graphene-COO?]5) electrode exhibits potent electrocatalytic activity towards the electro-oxidation of nicotinamide adenine dinucleotide (NADH). A substantial decrease in the overpotential was observed at modified electrode, and the electrode showed high sensitivity to the electrocatalytic oxidation of NADH. The modified electrode was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The diffusion coefficient was calculated by chronocoulometry. Chronoamperometric studies showed the linear relationship between oxidation peak current and the concentration of NADH in the range 25–250?μM (R?=?0.999) with the detection limit of 0.1?μM (S/N?=?3). Further, dopamine, uric acid, acetaminophen and hydrogen peroxide do not interfere in the detection of NADH. The ability of MWCNTs and graphene to promote the electron transfer between NADH and the electrode exhibits a promising biocompatible platform for development of dehydrogenase-based amperometric biosensors. Alcohol dehydrogenase (ADH) was casted on Gr/(PDDA/PSS-[MWCNTs-NH 3 + -graphene-COO?]5) electrode; the resulting biosensor showed rapid and high sensitive amperometric response to ethanol with the detection limit of 10?μM (S/N?=?3).  相似文献   

4.
A novel voltammetric method for the sensitive determination of ethylenediaminetetraacetic acid (EDTA) was developed based on a graphene oxide (GO) modified electrode. In acetate buffer solution, GO showed a voltammetric response composed of a sharp anodic peak and a weak cathodic peak. When EDTA was present in the solution, the voltammetric response of GO was suppressed. Under optimum conditions, the response of the GO‐modified electrode was inversely proportional to the concentration of EDTA from 6.0×10?7 to 1.0×10?4 mol/L. Using such a GO‐based voltammetry, the effective photoelectrocatalytic degradation of EDTA over a TiO2 film electrode was evaluated and some influencing factors were investigated.  相似文献   

5.
Poly(N-isopropylacrylamide)-modified graphene oxide (PNIPAm-GO), which is a type of thermally responsive GO, was designed and synthesized through a covalent “grafting-from” strategy. The as-prepared modified nanosheets integrated the individual advantages of two components, such as the thermal sensitivity of the PNIPAm terminal as well as the conductivity and the open 2D structure of the GO substrate. PNIPAm-GO was able to perform the reversible regulation of hydrophilicity/hydrophobicity in aqueous solution upon variations in the temperature. Such a unique property might also lead to the utilization of PNIPAm-GO as an intelligent electrode material to achieve a switchable electrochemical response toward a [Fe(CN)6]3−/4− probe. The PNIPAm-GO modified glassy carbon electrode (PNIPAm-GO/GC electrode) was able to exhibit better electrochemical performance in an ON/OFF switching effect than the PNIPAm-modified glassy carbon electrode (PNIPAm/GC electrode) without GO owing to the intrinsic properties and large surface area of the introduced GO. Moreover, it was found that the PNIPAm-GO/GC electrode also displayed excellent thermally responsive electrocatalysis toward the detection of 1,4-dihydro-β-nicotinamide adenine dinucleotide (NADH) and dopamine (DA), which resulted in two different catalytic statuses on the same electrode. This kind of switchable catalytic performance of the PNIPAm-GO/GC electrode might greatly enhance the flexibility of its application, and thus it is expected to have wide potential for applications in the fields of biosensors and biocatalysis.  相似文献   

6.
Here we investigate the use of 3D printed graphene/poly(lactic acid) (PLA) electrodes for quantifying trace amounts of Hg, Pb, and Cd. We prepared cylindrical electrodes by sealing a 600 μm diameter graphene/PLA filament in a pipette tip filled with epoxy. We characterized the electrodes using scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry in ferrocene methanol. The physical characterization showed a significant amount of disorder in the carbon structure and the electrochemical characterization showed quasi‐reversible behavior without any electrode pretreatment. We then used unmodified graphene/PLA electrode to quantify Hg, and Pb and Cd in 0.01 M HCl and 0.1 M acetate buffer using square wave anodic stripping voltammetry. We were able to quantify Hg with a limit of detection (LOD) of 6.1 nM (1.2 ppb), but Pb and Cd did not present measurable peaks at concentrations below ~400 nM. We improved the LODs for Pb and Cd by depositing Bi microparticles on the graphene/PLA and, after optimization, achieved clear stripping peaks at the 20 nM level for both ions (4.1 and 2.2 ppb for Pb2+ and Cd2+, respectively). The results obtained for all three metals allowed quantification below the US Environmental Protection Agency action limits in drinking water.  相似文献   

7.
Liquid chromatography with pulsed amperometric detection (PAD) at an Au electrode was successfully applied for speciation of mercury: inorganic mercury, methylmercury and ethylmercury. The optimized conditions for triple-step potential waveforms utilized in PAD were: E1 1800 mV, t1 50 ms; E2 300 mV, t2 3850 ms; E3 750 mV, t3 100 ms; mercury oxidation was monitored at E3. With the eluent of HClO4 (0.10 M) + KCl (1.0 mM) + CH3CN (1.0%) at a flow rate 0.80 mL/min, three mercury species were fully separated in 6 min on a glass column (3 mm × 10 cm) packed with Chemcosorb C18 (5 μm). However, the first peak (inorganic mercury) was commonly overlapped by the solvent front. The relative standard deviations (n = 6) for methylmercury (15 ppb) and ethylmercury (30 ppb) were 4.2% and 2.8%, respectively. The linear range tested was 2 – 500 ppb (r = 0.9998) for methylmercury, and was 4 – 1000 ppb (r = 1.000) for ethylmercury. The detection limits (S/N = 3) were 1.2 ppb and 1.8 ppb for methylmercury and ethylmercury, respectively. The results of determination of the mercury-containing species thimerosat in three commercial contact-lens solutions agreed satisfactorily with the expected values.  相似文献   

8.
《Electroanalysis》2006,18(18):1763-1770
Poly(L ‐lactide) stabilized gold nanoparticles (designated as PLA–AuNP) with an average particle size of ca. 10 nm were used to modify a disposable screen‐printed carbon electrode (SPE) for the detection of As(III) by differential pulse anodic stripping voltammetry. Gold modification was evaluated by cyclic voltammetry, whereas scanning electron microscopy and transmission electron microscopy revealed the size and distribution of gold nanoparticles. The PLA–AuNP/SPE was applied effectively to detect toxic As(III) in HCl medium. Under the optimal experimental conditions, a linear calibration curve up to 4 ppm with a detection limit (S/N=3) of 0.09 ppb was obtained. The sensitivity was good enough to detect As(III) at levels lower than the current EPA standard (10 ppb). Most importantly, the PLA–AuNP/SPE can be tolerable from the interference of Cu, Cd, Fe, Zn, Mn, and Ni and hence provides a direct and selective detection method for As(III) in natural waters. Practical utility of the PLA–AuNP/SPE was demonstrated to detect As(III) in “Blackfoot” disease endemic village groundwater from southwestern coast area of Taiwan (Pei‐Men).  相似文献   

9.
We studied sensor application of a graphene oxide and hematite (α‐Fe2O3/GO) composite electrode well‐characterized by the SEM and XRD. Through differential pulse voltammetry (DPV), oxidation of dexamethasone sodium phosphate (DSP) was studied at the surface of a glassy carbon electrode (GCE) modified with graphene oxide nanosheets (GO) and the α‐Fe2O3/GO composite. The values of the transfer coefficient (α) and the diffusion coefficient (D) of DSP were 0.5961 and 4.71×10?5 cm2 s?1 respectively. In the linear range of 0.1–50 μM, the detection limit (DL) was 0.076 μM. In the second step, a GCE was modified with α‐Fe2O3/GO composite and the DSP measurement step was repeated to analyzed and compare the effects of hematite nanoparticles present on graphene oxide surfaces. According to the results, α and D were 0.52 and 2.406×10?4 cm2 s?1 respectively and the DL was 0.046 μM in the linear range of 0.1–10.0 μM. The sensor is simple, inexpensive and uses blood serum.  相似文献   

10.
将稀土纳米材料Er2O3用于构建葡萄糖生物传感器。Er2O3和氧化石墨烯形成复合基底,将葡萄糖氧化酶(GOD)固载在玻碳电极表面。首先利用SEM和XRD技术对所制备的Er2O3和氧化石墨烯纳米材料进行表征。利用EIS和CV对整个生物传感器制备过程进行表征。Er2O3的存在能有效的保持GOD的生物活性并加速其电子传递速率。由于Er2O3和氧化石墨烯之间的协同效应,使得制备的传感器具有一对良好的氧化还原峰,证实GOD和电极之间的直接传递性能。当用于对葡萄糖的电催化氧化时,传感器的CV响应随着葡萄糖浓度的增加而变弱。在葡萄糖浓度为1~10 mmol·L-1范围内,CV响应值与葡萄糖浓度成线性关系。此外,传感器具有好的稳定性和重现性。  相似文献   

11.
将稀土纳米材料Er2O3用于构建葡萄糖生物传感器。Er2O3和氧化石墨烯形成复合基底,将葡萄糖氧化酶(GOD)固载在玻碳电极表面。首先利用SEM和XRD技术对所制备的Er2O3和氧化石墨烯纳米材料进行表征。利用EIS和CV对整个生物传感器制备过程进行表征。Er2O3的存在能有效地保持GOD的生物活性并加速其与电极之间的电子传递。由于Er2O3和氧化石墨烯之间的协同效应,使得制备的传感器在CV图中呈现一对明显的氧化还原峰,证实GOD和电极之间的直接电子传递性能。当用于对葡萄糖的电催化氧化时,传感器的CV响应随着葡萄糖浓度的增加而变弱。在葡萄糖浓度为1~10 mmol·L-1范围内,CV响应值与葡萄糖浓度成线性关系。此外,传感器具有好的稳定性和重现性。  相似文献   

12.
In this work, an antimony trioxide-modified multi-walled carbon nanotube paste electrode (Sb2O3/CNTPE) was employed for determination of Cu2+ ions by using square wave anodic stripping voltammetry (SWASV) in the presence of 8-hydroxy-7-iodo-5-quinoline sulfonic acid (HIQSA) as a chelating agent. The field emission scanning electron microscopy (FE-SEM), energy-dispersive spectroscopy (EDS) and electrochemical impedance spectroscopy (EIS) methods were applied to estimate the morphology and properties of the modified electrode. Measurements related to SWASV were taken in 0.6 M HCl at ?1.0 V versus Ag|AgCl|KCl (3 M) for 90 s (deposition step). After equilibrium time of 15 s, an ASV appeared at 0.0 V versus Ag|AgCl|KCl (3 M) (stripping step). The sensor depicted a fairly linear response for Cu2+ in the concentration range of 2–100 ppb with appropriate detection limit about 0.39 ppb and limit of quantification about 1.3 ppb. The stability of the modified electrode during 7 weeks and its behavior in the presence of some metal ions was evaluated. The practical applicability of the Sb2O3/CNTPE was established on the voltammetric determination of Cu2+ in tap water as a sample.  相似文献   

13.
The preparation and study of electrochemical properties of a graphite screen-printed electrode (SPE) modified with the GO/Fe3O4@SiO2 (GO is graphene oxide) nanocomposites are described. The morphologies of the GO/Fe3O4@SiO2 nanocomposites were examined by scanning electron microscopy. The electrochemical oxidation of vitamin B6 (pyridoxine) on SPE modified with the GO/Fe3O4@SiO2 nanocomposite was investigated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. Under optimum conditions (pH 7.0), the vitamin B6 oxidation at the surface of the modified SPE occurs at a potential about 190 mV less positive than that at the unmodified SPE. A linear voltammetric response for vitamin B6 was obtained in the concentration range 1.0?10 6—9.0?10 4 mol L–1 with a detection limit of 5.2?10 7 mol L–1 using differential pulse voltammetry. The developed sensor was also successfully applied for determination of trace level of vitamin B6 in both the standard vitamin B6 sample and biological samples (urine).  相似文献   

14.
A novel electrochemical platform based on nickel oxide (NiO) nanoparticles and TiO2–graphene (TiO2–Gr) was developed for the direct electrochemistry of glucose oxidase (GOD). The electrochemical behavior of the sensor was studied using cyclic voltammetry and chronoamperometry. The experimental results demonstrated that the nanocomposite well retained the activity of GOD and the modified electrode GOD/NiO/TiO2–Gr/GCE exhibited excellent electrocatalytic activity toward the redox of GOD as evidenced by the significant enhancement of redox peak currents in comparison with bare GCE. The biosensor responded linearly to glucose in the range of 1.0–12.0?mM, with a sensitivity of 4.129?μA?mM?1 and a detection limit of 1.2?×?10?6?M under optimized conditions. The response time of the biosensor was 3?s. In addition, the developed biosensor possessed good reproducibility and stability, and there was negligible interference from other electroactive components.  相似文献   

15.
A Bi2S3/graphene oxide (GO) composite enwrapped by a poly(3,4‐ethylenedioxythiophene) (PEDOT) coating was prepared for the first time for use as an anode in Li‐ion batteries. Pristine Bi2S3 nanoflowers and composites of Bi2S3/GO and Bi2S3/GO/PEDOT were assembled into half cells with Li metal as the counter electrode, and initial discharge capacities of 833, 1020, and 1300 mAh g?1, respectively, were obtained. Composites of Bi2S3/GO/PEDOT and Bi2S3/GO showed superior cycling stability and better rate capability than pristine Bi2S3. GO provides highly conducting interconnections, which allow facile propagation of electrons during charge/discharge, and this improves the ion‐uptake capability of the Bi2S3 nanoflowers and also increases the rate capability. PEDOT furnishes a protective coating that prevents detachment of the material from the current collector during cycling, and it also imparts better cycling stability to the Bi2S3/GO/PEDOT composite.  相似文献   

16.
In this work, a sensitive electrochemical aptasensor for the detection of adenosine triphosphate (ATP) has been introduced. A simple and non-enzymatic signal amplification strategy is utilized using silver nanoparticle-decorated graphene oxide (AgNPs–GO) as a redox probe. The modified electrode surface was characterized by scanning electron microscopy, FTIR and UV–Vis spectroscopy, and electrochemical impedance spectroscopy. GO provides an excellent substrate for the presence of the large number of AgNPs, so the monitored oxidation signal of AgNPs has been amplified. ATP-specific DNA aptamer is split into two fragments (F1 & F2) in order to design a sandwich-type assay. For the construction of the sensor, the surface of a graphite screen-printed electrode is modified with electrodeposited gold nanoparticles followed by self-assembling a monolayer of 3-mercaptopropionic acid on the electrode surface. The first amino-labeled fragment, F1, is immobilized on the modified electrode via carbodiimide chemistry. The synthesized AgNPs–GO interacts with F1 via \(\pi{-}\pi\) stacking. In the presence of ATP, the second fragment of the aptamer, F2, forms an associated complex with the immobilized F1 and causes AgNPs–GO to leave the surface. Consequently, a remarkable decrease in the oxidation signal of the AgNPs is observed. The percentage of this decrease has been monitored as an analytical signal, which is proportional to ATP concentration, and delivers a linear response over the range of 10.0 (±0.6) to 850 (±5) nM with a detection limit of 5.0 (±0.2) nM.  相似文献   

17.
An electrode of hydrated tungsten oxide (WO3?nH2O) embedded chitosan‐co‐polyaniline (CHIT‐co‐PANI) composite was electrochemically prepared on an indium tin oxide (ITO) coated glass surface using mineral acid as a supporting electrolyte. The resulting CHIT‐co‐PANI/WO3?nH2O/ITO electrode was characterized using ultraviolet‐visible spectroscopy (UV‐vis), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV), and scanning electron microscopy (SEM). The composite electrode exhibited a three‐dimensional nanofibrous structure with the diameter of the nanofibers ranging from 20 to 100 nm. The CHIT‐co‐PANI/WO3?nH2O/ITO electrode allowed for the low potential detection of NO2 gas in acidic medium. The NO2 gas sensing characteristics were studied by measuring change in the current with respect to concentration and time. Using the CHIT‐co‐PANI/WO3?nH2O/ITO electrode, NO2 gas was detected electrochemically without interference at pH 2.0 and 0.25 V vs. Ag/AgCl. The current of the electrochemical cell with the CHIT‐co‐PANI/WO3?nH2O/ITO electrode decreased linearly with an increase in NO2 gas concentration in a range from 100 to 500 ppb with a response time of eight seconds.  相似文献   

18.
A high-sensitive nonenzymatic hydrogen peroxide (H2O2) biosensor based on cuprous iodide and graphene (CuI/Gr) composites has been explored for the detection of H2O2 released by living cells and monitoring the oxidative stress of cells under excellular stimulation. The biosensor properties were evaluated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), amperometric i-t curve, and the redox-competition mode of scanning electrochemical microscopy (SECM). Our observations demonstrate that the CuI/Gr nanocomposites modified glassy carbon electrode (GCE) exhibits excellent catalytic activity for H2O2 with relatively low detection limit and a wide linear range from 0.5 μM to 3 mM. Moreover, the redox-competition mode of SECM imaging study further illustrates the improved electrochemical catalytic capability for H2O2 reduction with CuI/Gr nanocomposites deposited on graphite electrode. Hence, the as-prepared nonenzymatic H2O2 biosensor could be used to detect H2O2 release from different kinds of living cells under stimulation while eliminating the interference of ascorbic acid.  相似文献   

19.
《Electroanalysis》2017,29(9):2044-2052
This paper demonstrated using polyethylenimine (PEI)‐functionalized graphene (Gr) incorporating tin oxide (SnO2) hybrid nanocomposite as a platform for nonenzymatic H2O2 electrochemical sensor. The results of UV‐vis spectroscopy and X‐ray diffraction (XRD) confirmed the simultaneous formation of tin oxide (SnO2) nanocomposite and reduction of graphene oxide (GO). Transmission electron microscopy (TEM) images showed a uniform distribution of nanometer‐sized tin oxide nanoparticles on the grapheme sheets, which could be achieved using stannous chloride (SnCl2) complex instead of tin oxide as precursor. The electrochemical measurements, including cyclic voltammetry (CV) and amperometric performance (I‐t), showed that the PEI‐functionalized Gr supported SnO2 (SnO2‐PEI‐Gr) exhibited an excellent electrocatalytic activity toward the H2O2. The corresponding calibration curve of the current response showed a linear detection range of 9×10−6∼1.64×10−3 mol L−1, while the limit of detection was estimated to be 1×10−6 mol L−1. Electrochemical studies indicated that SnO2 and functionalized Gr worked synergistically for the detection of H2O2.  相似文献   

20.
In this study, biodegradable polylactic acid (PLA) and PLA nanocomposite scaffolds reinforced with magnetic and conductive fillers, were processed via fused filament fabrication additive manufacturing and their bioactivity and biodegradation characteristics were examined. Porous 3D architectures with 50% bulk porosity were 3D printed, and their physicochemical properties were evaluated. Thermal analysis confirmed the presence of ~18 wt% of carbon nanostructures (CNF and GNP; nowonwards CNF) and ~37 wt% of magnetic iron oxide (Fe2O3) particles in the filaments. The in vitro degradation tests of scaffolds showed porous and fractured struts after 2 and 4 weeks of immersion in DMEM respectively, although a negligible weight loss is observed. Greater extent of degradation is observed in PLA with magnetic fillers followed by PLA with conductive fillers and neat PLA. In vitro bioactivity study of scaffolds indicate enhancement from ~2.9% (PLA) to ~5.32% (PLA/CNF) and ~ 3.12% (PLA/Fe2O3). Stiffness calculated from the compression tests showed decrease from ~680 MPa (PLA) to 533 MPa and 425 MPa for PLA/CNF and PLA/Fe2O3 respectively. Enhanced bioactivity and faster biodegradation response of PLA nanocomposites with conductive fillers make them a potential candidate for tissue engineering applications such as scaffold bone replacement and regeneration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号