首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Here we demonstrate for the first time that by physically adsorbing aptamer onto conductive film assembled via alternate adsorption of graphene/polyelectrolyte and methylene blue/polyelectrolyte, a label-free electrochemical aptasensor with high sensitivity and selectivity for peptide detection is constructed. Graphene multilayer derived from layer-by-layer assembly has played significant roles in this sensing strategy: allowing accumulation of methylene blue, facilitating electron transfer and providing much more adsorption site. As compared to previous electrochemical aptasensors, the current sensor based on graphene multilayer alternated with electroactive molecule layer offers extremely high capability for sensitive detection of target without interference of environmental surrounding. This electroactive probe-confined graphene multilayer confers great flexibility to combine with differential pulse voltammetry (DPV) together. In the presence of target d entiomer of arginine vasopressin (d-VP), the binding of peptide to aptamer block the electron transfer process of MB, leading to decreased current peak of DPV. By this way, this electrochemical aptasensor based on electroactive molecule-intercalated graphene multilayer provide highly sensitive and specific detection of d-VP with the lowest detectable concentration of 1 ng mL−1 and a wide detection range from 1 to 265 ng mL−1.  相似文献   

2.
New methylene blue (NMB) dye incorporated into AlMCM‐41 surfactant‐free and hybrid surfactant‐AlMCM‐41 mesophase. UV‐vis evidence shows that new methylene blue dye protonated in both cases of zeolites. New methylene blue is electroactive in zeolites and their electrochemical activity has been studied by cyclic voltammetry and compared to that of NMB in aqueous solutions. New methylene blue molecules are not released to the solution during CV measurements and are accessible to H3O+ ions. The presence of surfactant affects the kinetics of the redox process through proton ions diffusion. The midpoint potentials (Em) values show that new methylene blue dye incorporated into AlMCM‐41 can be reduced easily with respect to solution new methylene blue. New methylene blue interacting with surfactant polar heads and residual Br? ions as a results, it shows a couple of peaks in high potential with respect to new methylene blue solution. The electrode made with methylene blue‐AlMCM‐41 without surfactant was used for the mediated oxidation of ascorbic acid. The anodic peak current observed in cyclic voltammetry was linearly dependent on the ascorbic acid concentration. The calibration plot was linear over the ascorbic acid concentration range 1.0×10?5 to 5.0×10?4 M. The detection limit of the method is 1.0×10?5 M, low enough for trace ascorbic acid determination in various real samples.  相似文献   

3.
Summary The potential of capillary zone electrophoresis has been investigated for the separation and quantitative determination of some quinolone antibiotics. The influence of different conditions, such as the nature and concentration of the electrophoretic electrolyte, on migration time, peak symmetry, efficiency and resolution was studied. A buffer consisting of 100mm HEPES adjusted to pH 8.5 containing 10% (v/v) acetonitrile was found to furnish a very efficient and stable electrophoretic system for the separation of exoxacin, ciprofloxacin, ofloxacin, oxolinic acid, nalidixic acid and pipemedic acid. A linear relationship between concentration and peak area for each compound was obtained in the concentration range 0.25–40 μg mL−1; detection limits were approximately 0.25 ng mL−1. It was demonstrated that the method can be used for the simultaneous determination of these six antibiotics in serum and urine samples.  相似文献   

4.
Summary A simple, sensitive and rapid capillary electrophoretic method has been developed for the separation and quantification of amiodarone and its metabolite, desethylamiodarone. The compounds were separated in a capillary of 45 cm effective length and 75 μm i.d., by use of an applied voltage of 25 kV and an electrolyte containing 15mm ADA buffer (pH 7.5), 10mm SDS, and 70% (v/v) acetonitrile. The selectivity, precision, linearity, range, sensitivity, and robustness of the method were good. The applicability of the assay was demonstrated by analyzing these drugs in serum. Electrokinetic injection with field-amplified sample-stacking was used to increase sensitivity. The limit of detection of the serum assay was 6.46 ng mL−1 and the precision 3.7%.  相似文献   

5.
Summary A simple and rapid capillary zone electrophoretic method with UV detection has been developed for determination of tosufloxacin and trovafloxacin. The separation was performed in fused-silica capillaries (57 cm length × 75μm i.d.); the running buffer was 35mm borate + 35mm phosphate buffer solution, pH 8.6, containing 6% (v/v) acetonitrile. The applied potential was 15 kV, the temperature 30°C, and detection was at 262 nm. Piromidic acid was used as the internal standard. Response was linearly dependent on concentration in the range 1.0–120.0 μg mL−1 and the detection limit was 0.2 μg mL−1 for both compounds. The analysis was highly reproducible (RSD between 3.41 and 1.25%). The method was applied to the determination of tosufloxacin and trovafloxacin in human and rat urine. The method was validated by using HPLC as a reference method. Recovery was between 96.8 and 102%.  相似文献   

6.
Summary A capillary zone electrophoretic method for the analysis of phenolic acids in soil and plant extracts was developed with direct UV detection using a phosphate electrolyte solution. The electrophoretic separation required the phenolic acids to be charged at a pH above their pKa in order to achieve their migration towards the anode. Electroosmotic flow (EOF) was reversed in direction by adding tetradecyltrimethylammonium bromide (TTAB). Factors affecting the separation selectivity, including the buffer pH and EOF modifiers, were investigated systematically. Eight phenolic acids were separated and detected in 10 min using an electrolyte containing 25 mM phosphate, 0.5 mM TTAB and 15% acetonitrile (v/v) at pH of 7.20. Linear plots for the test phenolic acids were obtained in a concentration range of 0.01–1 mM with detection limits in the range of 1.0–7.0 μM. The recoveries ranged from 92.8 to 102.3% in soil and plant tissues samples spiked at 100 μM and the relative standard deviation based on the peak area were ranged 2.0 to 4.5%. The proposed method was used for the determination of phenolic acids in plant tissue and soil extracts with direct injection.  相似文献   

7.
The influence of aminoacid and peptide type buffers as the separation electrolyte to the resolution of underivatized neutral carbohydrates in capillary electrophoresis was investigated. With the use of plain glycylglycine as the background electrolyte, a noticeable improvement in the resolution of carbohydrates was observed. Without any additive, 50 mmol L−1 glycylglycine electrolyte at pH 12 provides both the fast separation and indirect detection of sugars. The electrophoretic mobilities of 16 sugars were calculated at this buffer and the combinations of 10 sugars were simultaneously detected. The method was applied to the determination of sucrose, glucose, and fructose in commercial juice samples.  相似文献   

8.

The relationship between local structure and visible-light photocatalytic ability of tin silicate glass prepared by sol–gel method was investigated. 119Sn Mössbauer spectrum of SnOx·SiO2 glass prepared from SnCl2 showed a small peak of SnII component besides the major amount of SnIV. The smallest bandgap energy of 2.5 ± 0.5 eV was estimated from Tauc plot, and the largest first order rate constant (k) of (13.8 ± 0.1) 10−3 min−1 was recorded from the methylene blue degradation test under visible-light irradiation. It is concluded that SnII shows remarkable photocatalytic ability when it is incorporated into silica glass matrix.

  相似文献   

9.
A simple and rapid method has been developed for the analysis of anthracycline antibiotics doxorubicin (DOX) and daunorubicin (DAU) in human serum using mirochip-based capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection. In this study, method development included studies of the effect of buffer pH, buffer concentration, organic solvents and separation voltage on sensitivity and separation efficiencies for the CE separation of DOX and DAU. Acetonitrile was found to have significantly improved the sensitivity and separation efficiency. The method was validated with regard to reproducibilities, linearity and limit of detection (LOD). The optimum electrophoretic separation conditions were 10 mM sodium tetraborate buffer at pH 9.5 with 40% acetonitrile (V/V) and a separation voltage of 2.1 kV. DOX and DAU were separated in 60 s under the optimum separation conditions. Linear relationships were obtained between the concentration and peak area (or peak height) in the 1–75 µg mL− 1 range and with the detection limits of 0.3 and 0.2 μg mL− 1 for DOX and DAU, respectively. The stability of both migration time and peak height of the analytes showed relative standard deviations of less than 5% (n = 9). The potential of this method was verified by spiking a human serum sample with the two drugs and analyzing the recovery ratios.  相似文献   

10.
Serotonin (5-hydroxytryptamine, 5-HT) plays vital roles in regulating gastrointestinal functions. Thus, the detection of 5-HT in the gastrointestinal tract is of great importance for biomedical research, medical diagnosis, and pharmaceutical therapy. This paper presents a simple, sensitive, and fast method for the quantification of luminally released serotonin in the feces and tissues of the rat proximal colon by means of capillary electrophoresis with laser-induced fluorescence detection. 5-Carboxyfluorescein N-succinimidyl ester was used for precolumn derivatization of serotonin. The optimal separation and detection conditions were obtained with an electrophoretic buffer containing 60 mM borate (pH 8.90) and an air-cooled argon-ion laser (excitation at 488 nm, emission at 520 nm). The serotonin concentrations in the feces and tissues of proximal colons were analyzed with this method, and the average values of serotonin in the feces samples were 1.951 ± 0.446 ng/mg (male) and 2.095 ± 0.533 ng/mg (female) and 1.397 ± 0.267 ng/mg in rat proximal colon tissues. The results demonstrate that this method can accurately determine luminally released 5-HT in rats.  相似文献   

11.
用电化学氧化法使玻碳电极表面氧化生成羧基,利用偶联活化试剂将1.0G树状高分子(PAMAM)固定在玻碳电极表面,并通过共价结合固定ssDNA。以亚甲基蓝为指示剂,采用循环伏安法、示差脉冲伏安法等电化学方法对DNA电化学生物传感器进行了表征。结果发现,通过亚甲基蓝与双链dsDNA作用的氧化还原电流的变化,可以识别和定量检测溶液中互补的ssDNA片段。经过条件优化,本法测定DNA的浓度线性范围为2×10-9~2×10-7mol/L,检出限为1×10-9mol/L。  相似文献   

12.
Novel films consisting of multi-walled carbon nanotubes (MWCNTs) were fabricated by means of chemical vapor deposition with decomposition of either acetonitrile (ACN) or benzene (BZ) using ferrocene as catalyst. The electrochemical responses of MWCNT-based films towards the ferrocyanide/ferricyanide, [Fe(CN)6]3?/4? redox couple were probed by means of cyclic voltammetry and electrochemical impedance spectroscopy at 25.0?±?0.5?°C. Both MWCNT-based films exhibit Nernstian response towards [Fe(CN)6]3?/4? with some slight kinetic differences. Namely, heterogeneous electron transfer rate constants lying in ranges of 2.69?×?10?2?C1.7?×?10?3 and 9.0?×?10?3?C2.6?×?10?3?cm·s?1 were obtained at v?=?0.05?V·s?1 for MWCNTACN and MWCNTBZ, respectively. The detection limit of MWCNTACN, estimated to be about 4.70?×?10?7?mol·L?1 at v?=?0.05?V·s?1, tends to become slightly poorer with the increase of the scan rate, namely at v?=?0.10?V·s?1 the detection limit of 1.70?×?10?6?mol·L?1 was determined. Slightly poorer response ability was exhibited by MWCNTBZ; specifically the detection limits of 1.57?×?10?6 and 4.35?×?10?6?mol·L?1 were determined at v?=?0.05 and v?=?0.10?V·s?1, respectively. The sensitivities of MWCNTACN and MWCNTBZ towards [Fe(CN)6]3?/4? were determined as 1.60?×?10?7 and 1.51?×?10?7?A·L·mol?1·cm?2, respectively. The excellent electrochemical performance of MWCNTACN is attributed to the presence of incorporated nitrogen in the nanotube??s structure.  相似文献   

13.
A simple, rapid and validated capillary electrophoretic method has been developed for the separation and determination of ofloxacin and ornidazole in pharmaceutical formulations with detection at 230 nm. Optimal conditions for the quantitative separations were investigated. Analysis times shorter than 4 min were obtained using a background electrolyte solution consisting of 25 mmol/L phosphoric acid adjusted with 1 m Tris buffer to pH 8.5, with hydrodynamic injection of 5 s and 20 kV separation voltage. The validation criteria for accuracy, precision, linearity and limits of detection and quantitation were examined and discussed. An excellent linearity was obtained in concentration range 25–250 µg/mL. The detection limits for ofloxacin and ornidazole were 1.03 ± 0.11 and 1.80 ± 0.06 µg/mL, respectively. The proposed method has been applied for the analysis of ofloxacin and ornidazole both individually and in a combined dosage tablet formulation. The proposed validated method showed recoveries between 96.16 and 105.23% of the nominal contents. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Microchip capillary electrophoresis in mixed hydro-organic solvent combined with laser-induced fluorescence detection was developed for the separation and detection of physcion and rhein in rhubarb. In contrast to the conventional capillary electrophoresis method, ammonium acetate-dimethyl sulfoxide was used as the basic buffer system in this method. The effects of background buffer, buffer apparent pH*, buffer concentration, water ratio, sample preparation method, and separation voltage on separation and detection were investigated. Optimized separation and detection conditions were obtained: the buffer consisted of 20 mmol/L of ammonium acetate in hydro-organic solvent composed dimethyl sulfoxide, formamide, and water mixed at 60/20/20 (v/v/v) ratio. The separation voltage was 1.9 kV. Under these conditions, the physcion, rhein, and other components of rhubarb can be completely separated within 150 s. Under the methodological verification, good linearity (R ≥ 0.9995) for physcion and rhein, and low limits of detection (0.085 μg·mL−1 and 0.077 μg·mL−1, respectively), satisfactory peak area precisions, migration time precisions (1.74%–3.09%), and accuracy (recovery rate 97.8% and 101.4%) were achieved. It is shown that the proposed method is simple, efficient, fast, sensitive, simple instrument, consumes few samples, has low operating cost, and is linear.  相似文献   

15.
This article describes for the first time the combination of electrophoretic focusing on inverse electromigration dispersion (EMD) gradient, a new separation principle described in 2010, with electrospray-ionization (ESI) mass spectrometric detection. The separation of analytes along the electromigrating EMD profile proceeds so that each analyte is focused and concentrated within the profile at a particular position given by its pKa and ionic mobility. The proposed methodology combines this principle with the transport of the focused zones to the capillary end by superimposed electromigration, electroosmotic flow and ESI suction, and their detection by the MS detector. The designed electrolyte system based on maleic acid and 2,6-lutidine is suitable to create an inverse EMD gradient of required properties and its components are volatile enough to be compatible with the ESI interface. The characteristic properties of the proposed electrolyte system and of the formed inverse gradient are discussed in detail using calculated diagrams and computer simulations. It is shown that the system is surprisingly robust and allows sensitive analyses of trace amounts of weak acids in the pKa range between approx. 6 and 9. As a first practical application of electrophoretic focusing on inverse EMD gradient, the analysis of several sulfonamides in waters is reported. It demonstrates the potential of the developed methodology for fast and high-sensitivity analyses of ionic trace analytes, with reached LODs around 3 × 10−9 M (0.8 ng mL−1) of sulfonamides in spiked drinking water without any sample pretreatment.  相似文献   

16.
We present a method for finely adjustable electroosmotic flow (EOF) velocity in cathodic direction for the optimization of separations in capillary electrophoresis. To this end, we use surface modification of the separation fused silica capillary by the covalently attached copolymer of acrylamide (AM) and 2-acrylamido-2-methyl-1-propanesulfonate (AMPS), that is, poly(AM-co-AMPS) or PAMAMPS. Coatings were formed by the in-capillary polymerization of a mixture of the neutral AM and anionic AMPS monomers premixed in various ratios in order to control the charge density of the copolymer. EOF mobility varies in the 0 to ∼40 × 10−9 m2 V−1 s−1 interval for PAMAMPS coatings ranging from 0 to 60 mol.% of charged AMPS monomer. For EOF in PAMAMPS-treated capillaries, we observed (i) a negligible dependence on pH in the 2–10 interval, (ii) a minor variance among background electrolytes (BGEs) in function of their components and (iii) its standard decrease with increasing ionic strength of the BGE. Interest in variable cathodic EOF was demonstrated by the amelioration of separation of two kinds of isomeric anionic analytes, that is, monosaccharides phosphates and helquat enantiomers, in counter-EOF mode.  相似文献   

17.
A surfactant bilayer/diblock polymer coating was previously developed for the separation of proteins. The coating consisted of a mixture of the cationic surfactant dioctadecyldimethylammonium bromide (DODAB) and the neutral polymer poly-oxyethylene (POE) 40 stearate (Journal of Chromatography A 1130 (2006) 265–271). Herein an improved method of generating DODAB/POE stearate coatings is demonstrated, which yields more predictable EOF, more stable coatings, greater average efficiencies and easier method development. In this sequential preparation method the DODAB is first flowed through the capillary, followed by a flow of the POE stearate (sequential method). A tunable EOF (−2.40 to −0.17 × 10−4 cm2/Vs) is achieved by varying the POE chain length (8, 40 and 100 oxyethylene units). Mixtures of POE 8 and POE 40 stearate enabled continuous variation in EOF from −2.44 to −0.42 × 10−4 cm2/Vs. Separations of basic proteins yielded efficiencies of 760 000–940 000 plates/m. Coatings formed using the sequential method were more stable over a larger number of runs (%RSD for migration times: 0.7–1.0% over 30 runs) than those formed using the original mixed method (%RSD: 2.4–4.6% over 14 runs). The ability to tune the EOF is important in maximizing the resolution of analytes with similar electrophoretic mobilities. Histone proteins are separated on a sequentially coated capillary with resolution of nine possible subtypes. Acidic proteins are separated on a sequentially coated capillary at pH 6.4.  相似文献   

18.
A simple, accurate, precise, rapid and sensitive stability-indicating capillary electrophoresis (CE) method was optimized and validated for the simultaneous determination of norfloxacin and its inactive decarboxylated degradant in pharmaceuticals. The univariant method was used to optimize electrophoretic factors including injection time, separation voltage and column temperature. Electrolyte concentration and pH were optimized using the factorial design and response surface methods. The optimum conditions obtained were: 10 mmol l− 1 phosphate at pH 2.5, hydrodynamic injection time of 8 s at pressure 0.5 p.s.i., separation voltage 25 kV and column temperature 25 °C. The separation was carried out into a fused-silica capillary column (31.2 cm length × 50 μm i.d.) with detection at 301 and 285 nm for the intact drug and the degradant, respectively using a diode array detector. For both analytes, the method enjoys wide dynamic range (1-50 μg ml− 1) with good detectability (limits of detection 0.11 μg ml− 1). In addition, acceptable accuracy (recovery > 95%); and good repeatability and intermediate precision (RSD < 3.5%) were obtained.  相似文献   

19.
Electroosmotic flow (EOF) was determined in tridimensional (3D)-printed microchannels with dimensions smaller than 100 µm. Fused deposition modeling 3D printing using thermoplastic filaments of PETG (polyethylene terephthalate glycol), PLA (polylactic acid), and ABS (acrylonitrile butadiene styrene) were used to fabricate the microchannels. The current monitoring method and sodium phosphate solutions at different pH values (3–10) were used for the EOF mobility (µEOF) measurements, which ranged from 2.00 × 10−4 to 12.52 × 10−4 cm2 V−1 s−1. The highest and the smallest µEOF were obtained for the PLA and PETG microchannels, respectively. Adding the cationic surfactant cetyltrimethylammonium bromide to the sodium phosphate solution caused EOF direction reversion in all the studied microchannels. The obtained results can be interesting for developing 3D-printed microfluidic devices, in which EOF is relevant.  相似文献   

20.
Dynamic computer simulation data are compared for the first time with CE data obtained with a laboratory made system comprising an array of 8 contactless conductivity detectors (C4Ds). The experimental setup featured a 50 μm id linear polyacrylamide (LPA) coated fused‐silica capillary of 70 cm length and a purpose built sequential injection analysis manifold for fluid handling of continuous or discontinuous buffer configurations and sample injection. The LPA coated capillary exhibits a low EOF and the manifold allows the placement of the first detector at about 2.7 cm from the sample inlet. Agreement of simulated electropherograms with experimental data was obtained for the migration and separation of cationic and anionic analyte and system zones in CZE configurations in which EOF and other column properties are constant. For configurations with discontinuous buffer systems, including ITP, experimental data obtained with the array detector revealed that the EOF is not constant. Comparison of simulation and experimental data of ITP systems provided the insight that the EOF can be estimated with an ionic strength dependent model similar to that previously used to describe EOF in fused‐silica capillaries dynamically double coated with Polybrene and poly(vinylsulfonate). For the LPA coated capillaries, the electroosmotic mobility was determined to be 17‐fold smaller compared to the case with the charged double coating. Simulation and array detection provide means for quickly investigating electrophoretic transport and separation properties. Without realistic input parameters, modeling alone is not providing data that match CE results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号