首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We demonstrate a novel structure based on smart carbon nanocomposites intended for fabricating laser-triggered drug delivery devices (DDDs). The performance of the devices relies on nanocomposites’ photothermal effects that are based on polydimethylsiloxane (PDMS) with carbon nanoparticles (CNPs). Upon evaluating the main features of the nanocomposites through physicochemical and photomechanical characterizations, we identified the main photomechanical features to be considered for selecting a nanocomposite for the DDDs. The capabilities of the PDMS/CNPs prototypes for drug delivery were tested using rhodamine-B (Rh-B) as a marker solution, allowing for visualizing and quantifying the release of the marker contained within the device. Our results showed that the DDDs readily expel the Rh-B from the reservoir upon laser irradiation and the amount of released Rh-B depends on the exposure time. Additionally, we identified two main Rh-B release mechanisms, the first one is based on the device elastic deformation and the second one is based on bubble generation and its expansion into the device. Both mechanisms were further elucidated through numerical simulations and compared with the experimental results. These promising results demonstrate that an inexpensive nanocomposite such as PDMS/CNPs can serve as a foundation for novel DDDs with spatial and temporal release control through laser irradiation.  相似文献   

2.
A microfluidic device capable of exploiting the permeability of small molecules through polydimethylsiloxane (PDMS) has been fabricated in order to control the contents of microdroplets stored in storage wells. We demonstrate that protein precipitation and crystallization can be triggered by delivery of ethanol from a reservoir channel, thus controlling the protein solubility in microdroplets. Likewise quorum sensing in bacteria was triggered by delivery of the auto-inducer N-(3-oxododecanoyl)-l-homoserine lactone (OdDHL) through the PDMS membrane of the device.  相似文献   

3.
We report the development of a magnetically controlled drug delivery device for on-demand drug release to treat chronic diseases. The devices consist of drug-loaded micro-reservoirs (6 mm in diameter and ~550 μm in depth), sealed by magnetic PDMS (polydimethylsiloxane) membranes (? 6 mm × 40 μm) with laser-drilled apertures and actuated by an external magnetic field. We present a detailed analysis of the magnetic actuation forces and provide an estimate of the resulting membrane deflections. The reservoirs are fabricated by PDMS molding and loaded with drugs using solvent evaporation methods. Post-processing procedures using bovine serum albumin (BSA) adsorption on magnetic PDMS surfaces are carried out to modify the surface wettability and to allow water filling and dissolution of the drugs in the reservoirs. Detailed surface modification processes are described and characterized. The device demonstrates on-demand delivery of methylene blue (MB) as a model drug. Intermittent magnetic actuations of the device in a ~200 mT magnetic field show 10-fold increase in MB release compared to background release when the device is not actuated.  相似文献   

4.
Tan WH  Takeuchi S 《Lab on a chip》2008,8(2):259-266
This paper describes a selective retrieval method for arrayed monodisperse hydrogel beads containing cells. We implemented modifications such as: (i) the incorporation of cavities as nucleation sites, (ii) indirect retrieval using bubble powered jets and (iii) the use of low boiling point fluid in our device to realize a gentle optical-based retrieval method. Parametric studies confirmed that these modifications dramatically reduced both the intensity and duration of applied laser for bubble formation. We also demonstrated for the first time the formation of a bead-based dynamic cell microarray by introducing cell-encapsulating alginate beads into our dynamic microfluidic system, and successfully retrieved an alginate bead from a fluidic trap. Tests with trypan blue revealed that membrane integrity of the encapsulated cells was not compromised by the retrieval process.  相似文献   

5.
There is a need for a technology that can be incorporated into routine laboratory procedures to obtain a continuous, quantitative, fluorescence-based measurement of the dynamic behaviors of numerous individual living cells in parallel, while allowing other manipulations, such as staining, rinsing, and even retrieval of targeted cells. Here, we report a simple, low-cost microarray platform that can trap cells for dynamic single-cell analysis of mammalian cells. The elasticity of polydimethylsiloxane (PDMS) was utilized to trap tens of thousands of cells on an array. The PDMS microwell array was stretched by a tube through which cells were loaded on the array. Cells were trapped on the array by removal of the tube and relaxation of the PDMS. Once that was accomplished, the cells remained trapped on the array without continuous application of an external force and permitted subsequent manipulations, such as staining, rinsing, imaging, and even isolation of targeted cells. We demonstrate the utility of this platform by multicolor analysis of trapped cells and monitoring in individual cells real-time calcium flux after exposure to the calcium ionophore ionomycin. Additionally, a proof of concept for target cell isolation was demonstrated by using a microneedle to locally deform the PDMS membrane in order to retrieve a particular cell from the array.  相似文献   

6.
We report the development of a magnetically controlled MEMS device capable of on-demand release of defined quantities of an antiproliferative drug, docetaxel (DTX). Controlled release of DTX with a dosage suitable for the treatment of diabetic retinopathy has been achieved for 35 days. The device consists of a drug-loaded microreservoir (?6 mm ×~550 μm), sealed by an elastic magnetic PDMS (polydimethylsiloxane) membrane (?6 mm × 40 μm) with a laser-drilled aperture (~100 × 100 μm(2)). By applying a magnetic field, the magnetic PDMS membrane deforms, causing the discharge of the drug solution from the device. Controlled DTX release at a rate of 171 ± 16.7 ng per actuation interval has been achieved for 35 days using a 255 mT magnetic field. The background leakage of drug solution through the aperture was negligible at 0.053 ± 0.014 ng min(-1). The biological activity of the released drug was investigated using a cytotoxicity assay (cell apoptosis) for two cell lines, HUVEC (human umbilical vein endothelial cells) and PC3 (prostate cancer) cells. Reproducible release rates have been achieved and DTX within the PDMS MEMS reservoir maintains full pharmacological efficacy for more than two months. This device is a proof-of-concept development for targeted delivery of hydrophobic drugs such as DTX and other taxane-based agents that require accurate delivery in nanomolar concentrations.  相似文献   

7.
We describe the fabrication and performance of an integrated microelectrochemical reactor-a design possessing utility for multiple applications that include electrochemical sensing, the generation and manipulation of in-channel microfluidic pH gradients, and fluid actuation and flow. The device architecture is based on a three-electrode electrochemical cell design that incorporates a Pt interdigitated array (IDA) working (WE), a Pt counter (CE), and Ag pseudo-reference (RE) electrodes within a microfluidic network in which the WE is fully immersed in a liquid electrolyte confined in the channels. The microchannels are made from a conventional poly(dimethylsiloxane)(PDMS) elastomer, which serves also as a thin gas-permeable membrane through which gaseous reactants in the external ambient environment are supplied to the working electrode by diffusion. Due to the high permeability of oxygen through PDMS, the microfluidic cell supports significantly (>order of magnitude) higher current densities in the oxygen reduction reaction (ORR) than those measured in conventional (quiescent) electrochemical cells for the same electrode areas. We demonstrate in this work that, when operated at constant potential under mass transport control, the device can be utilized as a membrane-covered oxygen sensor, the response of which can be tuned by varying the thickness of the PDMS membrane. Depending on the experimental conditions under which the electrochemical ORR is performed, the data establish that the device can be operated as both a programmable pH gradient generator and a microfluidic pump.  相似文献   

8.
Lee JH  Song YA  Han J 《Lab on a chip》2008,8(4):596-601
In this paper, we report a new method of fabricating a high-throughput protein preconcentrator in poly(dimethylsiloxane) (PDMS) microfluidic chip format. We print a submicron thick ion-selective membrane on the glass substrate by using standard patterning techniques. By simply plasma-bonding a PDMS microfluidic device on top of the printed glass substrate, we can integrate the ion-selective membrane into the device and rapidly prototype a PDMS preconcentrator without complicated microfabrication and cumbersome integration processes. The PDMS preconcentrator shows a concentration factor as high as approximately 10(4) in 5 min. This printing method even allows fabricating a parallel array of preconcentrators to increase the concentrated sample volume, which can facilitate an integration of our microfluidic preconcentrator chip as a signal enhancing tool to various detectors such as a mass spectrometer.  相似文献   

9.
We describe the fabrication and performance of a passive, microfluidics-based H2-O2 microfluidic fuel cell using thin film Pt electrodes embedded in a poly(dimethylsiloxane) (PDMS) device. The electrode array is fully immersed in a liquid electrolyte confined inside the microchannel network, which serves also as a thin gas-permeable membrane through which the reactants are fed to the electrodes. The cell operates at room temperature with a maximum power density of around 700 microW/cm(2), while its performance, as recorded by monitoring the corresponding polarization curves and the power density plots, is affected by the pH of the electrolyte, its concentration, the surface area of the Pt electrodes, and the thickness of the PDMS membrane. The best results were obtained in basic solutions using electrochemically roughened Pt electrodes, the roughness factor, R(f), of which was around 90 relative to a smooth Pt film. In addition, the operating lifetime of the fuel cell was found to be longer for the one using higher surface area electrodes.  相似文献   

10.
Thermoplastics have been increasingly used for fabricating microfluidic devices because of their low cost, mechanical/biocompatible attributes, and well-established manufacturing processes. However, there is sometimes a need to integrate such a device with components made from other materials such as polydimethylsiloxane (PDMS). Bonding thermoplastics with PDMS to produce hybrid devices is not straightforward. We have reported our method to modify the surface property of a cyclic olefin copolymer (COC) substrate by using corona discharge and grafting polymerization of 3-(trimethoxysilyl)propyl methacrylate; the modified surface enabled strong bonding of COC with PDMS. In this paper, we report our studies on the surface modification mechanism using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and contact angle measurement. Using this bonding method, we fabricated a three-layer (COC/PDMS/COC) hybrid device consisting of elastomer-based valve arrays. The microvalve operation was confirmed through the displacement of a dye solution in a fluidic channel when the elastomer membrane was pneumatically actuated. Valve-enabled microfluidic handling was demonstrated.  相似文献   

11.
A flat membrane in tandem with a helical sorbent trap has been used for continuous sampling of the volatile organic products generated in the thermal degradation process of the polyvinyl chloride (PVC) in air, followed by on-line gas chromatographic separation and mass spectrometric identification. The membrane and trap tandem makes automatic collection, concentration, and injection of PVC volatile and semivolatile degradation products, and it is simple in terms of instrumentation and operation. The poly(dimethylsiloxane) (PDMS) membrane used in this study shows a low permeation for oxygenated derivatives and a high permeation for volatile aromatic and non-aromatic hydrocarbon, and chlorinated hydrocarbons. Consequently, the final chromatogram is significantly simplified. By heating the trap at fixed intervals of time, consecutive gas chromatograms are obtained in the monitoring process. The sensitivity of the method depends on the parameters that affect the time of trapping, and the permeation through the membrane.  相似文献   

12.
A coaxially heated membrane introduction mass spectrometry (MIMS) sampling interface is presented that demonstrates improved on-line performance for the direct measurement of semi-volatile organic compounds (SVOCs) in air and water samples at parts-per-trillion levels. The device is based on a polydimethylsiloxane (PDMS) capillary hollow fibre membrane (HFM) in a pneumatically assisted "flow-over" configuration that is resistively heated on the membrane interior via a coaxial nichrome wire, establishing a thermal gradient counter to the analyte concentration gradient. This arrangement allows for continuous and/or pulsed heating modes, affording excellent sensitivity for the on-line measurement of SVOCs while retaining sensitivity for volatile organic compounds (VOCs). In addition, the signal response time for SVOCs is reduced substantially over conventional "flow-over" MIMS interfaces. Separation and quantitation of analytes are achieved using quadrupole ion trap tandem mass spectrometry.  相似文献   

13.
Gas bubbles present a frequent challenge to the on-chip investigation and culture of biological cells and small organs. The presence of a single bubble can adversely impair biological function and often viability as it increases the wall shear stress in a liquid-perfused microchannel by at least one order of magnitude. We present a microfluidic strategy for in-plane trapping and removal of gas bubbles with volumes of 0.1-500 nL. The presented bubble trap is compatible with single-layer soft lithography and requires a footprint of less than ten square millimetres. Nitrogen bubbles were consistently removed at a rate of 0.14 μL min(-1). Experiments were complemented with analytical and numerical models to comprehensively characterize bubble removal for liquids with different wetting behaviour. Consistent long-term operation of the bubble trap was demonstrated by removing approximately 4000 bubbles during one day. In a case study, we successfully applied the bubble trap to the on-chip investigation of intact small blood vessels. Scalability of the design was demonstrated by realizing eight parallel traps at a total removal rate of 0.9 μL min(-1) (measured for nitrogen).  相似文献   

14.
A design for a passive, air-breathing microfluidic fuel cell utilizing formic acid (FA) as a fuel is described and its performance characterized. The fuel cell integrates high surface area platinum (cathode) and palladium-platinum (anode) alloy electrodes within a PDMS microfluidic network that keeps them fully immersed in a liquid electrolyte. The polymer network that comprises the device also serves as a self-supporting membrane through which FA and oxygen are supplied to the alloy anode and cathode, respectively, by passive permeation from external sources. The cell is based on a planar form-factor and in its operation exploits FA concentration gradients that form across the PDMS membrane. These latter gradients allow the device to operate stably, producing a nearly constant limiting power density of ~0.2 mW/cm2, without driven laminar flow of fluids or the incorporation of an in-channel separator between the anodic and the cathodic compartments. The power output of this elementary device in air is subject to electrolyte mass transport impacts, which can be reduced for a given design rule by decreasing the internal ohmic resistance of the cell. The results suggest that operational stability can be improved by decreasing the kinetic losses imposed on the cathode side of the cell due to FA crossover and modalities for doing so, such as by increasing the efficiency of fuel capture at the anode.  相似文献   

15.
Spatial control of cell growth on surfaces can be achieved by the selective deposition of molecules that influence cell adhesion. The fabrication of such substrates often relies upon photolithography and requires complex surface chemistry to anchor adhesive and inhibitory molecules. The production of simple, cost-effective substrates for cell patterning would benefit numerous areas of bioanalytical research including tissue engineering and biosensor development. Poly(dimethylsiloxane) (PDMS) is routinely used as a biomedical implant material and as a substrate for microfluidic device fabrication; however, the low surface energy and hydrophobic nature of PDMS inhibits its bioactivity. We present a method for the surface modification of PDMS to promote localized cell adhesion and proliferation. Thin metal films are deposited onto PDMS through a physical mask in the presence of a gaseous plasma. This treatment generates topographical and chemical modifications of the polymer surface. Removal of the deposited metal exposes roughened PDMS regions enriched with hydrophilic oxygen-containing species. The morphology and chemical composition of the patterned substrates were assessed by optical and atomic force microscopies as well as X-ray photoelectron spectroscopy. We observed a direct correlation between the surface modification of PDMS and the micropatterned adhesion of fibroblast cells. This simple protocol generates inexpensive, single-component substrates capable of directing cell attachment and growth.  相似文献   

16.
In this paper, we present a new impedance-based method to detect viable spores by electrically detecting their germination in real time within microfluidic biochips. We used Bacillus anthracis Sterne spores as the model organism. During germination, the spores release polar and ionic chemicals, such as dipicolinic acid (DPA), calcium ions, phosphate ions, and amino acids, which correspondingly increase the electrical conductivity of the medium in which the spores are suspended. We first present macro-scale measurements demonstrating that the germination of spores can be electrically detected at a concentration of 10(9) spores ml(-1) in sample volumes of 5 ml, by monitoring changes in the solution conductivity. Germination was induced by introducing an optimized germinant solution consisting of 10 mM L-alanine and 2 mM inosine. We then translated these results to a micro-fluidic biochip, which was a three-layer device: one layer of polydimethylsiloxane (PDMS) with valves, a second layer of PDMS with micro-fluidic channels and chambers, and the third layer with metal electrodes deposited on a pyrex substrate. Dielectrophoresis (DEP) was used to trap and concentrate the spores at the electrodes with greater than 90% efficiency, at a solution flow rate of 0.2 microl min(-1) with concentration factors between 107-109 spores ml(-1), from sample volumes of 1-5 microl. The spores were captured by DEP in deionized water within 1 min (total volume used ranged from 0.02 microl to 0.2 microl), and then germinant solution was introduced to the flow stream. The detection sensitivity was demonstrated to be as low as about a hundred spores in 0.1 nl, which is equivalent to a macroscale detection limit of approximately 10(9) spores ml(-1). We believe that this is the first demonstration of this application in microfluidic and BioMEMS devices.  相似文献   

17.
构建了一种基于渗透脱水模式的自动进样微流控结晶芯片. 该芯片通过真空预脱气将包含蛋白质和结晶剂的液滴自动分配至结晶微腔阵列中, 然后利用集成的一排包含不同浓度盐溶液的透析管道, 通过渗透脱水方式经一层聚二甲基硅氧烷(PDMS)膜实现液滴的逐渐浓缩, 使之趋于过饱和状态, 进而形成结晶. 此芯片可一次筛选较宽范围的过饱和状态, 实现蛋白质结晶的快速优化. 利用模式蛋白溶菌酶的结晶实验验证了该芯片的性能.  相似文献   

18.
We describe an advanced microfluidic hydrogen-air fuel cell (FC) that exhibits exceptional durability and high performance, most notably yielding stable output power (>100 days) without the use of an anode-cathode separator membrane. This FC embraces an entirely passive device architecture and, unlike conventional microfluidic designs that exploit laminar hydrodynamics, no external pumps are used to sustain or localize the reagent flow fields. The devices incorporate high surface area/porous metal and metal alloy electrodes that are embedded and fully immersed in liquid electrolyte confined in the channels of a poly(dimethylsiloxane) (PDMS)-based microfluidic network. The polymeric network also serves as a self-supporting membrane through which oxygen and hydrogen are supplied to the cathode and alloy anode, respectively, by permeation. The operational stability of the device and its performance is strongly dependent on the nature of the electrolyte used (5 M H2SO4 or 2.5 M NaOH) and composition of the anode material. The latter choice is optimized to decrease the sensitivity of the system to oxygen cross-over while still maintaining high activity towards the hydrogen oxidation reaction (HOR). Three types of high surface area anodes were tested in this work. These include: high-surface area electrodeposited Pt (Pt); high-surface area electrodeposited Pd (Pd); and thin palladium adlayers supported on a "porous" Pt electrode (Pd/Pt). The FCs display their best performance in 5 M H2SO4 using the Pd/Pt anode. This exceptional stability and performance was ascribed to several factors, namely: the high permeabilities of O2, H2, and CO2 in PDMS; the inhibition of the formation of insoluble carbonate species due to the presence of a highly acidic electrolyte; and the selectivity of the Pd/Pt anode toward the HOR. The stability of the device for long-term operation was modeled using a stack of three FCs as a power supply for a portable display that otherwise uses a 3 V battery.  相似文献   

19.
Yuen PK  Su H  Goral VN  Fink KA 《Lab on a chip》2011,11(8):1541-1544
This technical note presents a fabrication method and applications of three-dimensional (3D) interconnected microporous poly(dimethylsiloxane) (PDMS) microfluidic devices. Based on soft lithography, the microporous PDMS microfluidic devices were fabricated by molding a mixture of PDMS pre-polymer and sugar particles in a microstructured mold. After curing and demolding, the sugar particles were dissolved and washed away from the microstructured PDMS replica revealing 3D interconnected microporous structures. Other than introducing microporous structures into the PDMS replica, different sizes of sugar particles can be used to alter the surface wettability of the microporous PDMS replica. Oxygen plasma assisted bonding was used to enclose the microstructured microporous PDMS replica using a non-porous PDMS with inlet and outlet holes. A gas absorption reaction using carbon dioxide (CO(2)) gas acidified water was used to demonstrate the advantages and potential applications of the microporous PDMS microfluidic devices. We demonstrated that the acidification rate in the microporous PDMS microfluidic device was approximately 10 times faster than the non-porous PDMS microfluidic device under similar experimental conditions. The microporous PDMS microfluidic devices can also be used in cell culture applications where gas perfusion can improve cell survival and functions.  相似文献   

20.
Liu C  Cui D  Cai H  Chen X  Geng Z 《Electrophoresis》2006,27(14):2917-2923
We present a novel concept of glass/poly(dimethylsiloxane) (PDMS)/glass sandwich microchip and developed a thin-casting method for fabrication. Unlike the previously reported casting method for fabricating PDMS microchip, several drops of PDMS prepolymer were first added on the silanizing SU-8 master, then another glass plate was placed over the prepolymer as a cover plate, and formed a glass plate/PDMS prepolymer/SU-8 master sandwich mode. In order to form a thin PDMS membrane, a weight was placed on the glass plate. After the whole sandwich mode was cured at 80 degrees C for 30 min, the SU-8 master was easily peeled and the master microstructures were completely transferred to the PDMS membrane which was tightly stuck to the glass plate. The microchip was subsequently assembled by reversible sealing with the glass cover plate. We found that this PDMS sandwich microchip using the thin-casting method could withstand internal pressures of >150 kPa, more than 5 times higher than that of the PDMS hybrid microchip with reversible sealing. In addition, it shows an excellent heat-dissipating property and provides a user-friendly rigid interface just like a glass microchip, which facilitates manipulation of the microchip and fix tubing. As an application, PDMS sandwich microchips were tested in the capillary electrophoresis separation of fluorescein isothiocyanate-labeled amino acids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号