首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhao Y  Zheng J  Yang M  Yang G  Wu Y  Fu F 《Talanta》2011,84(3):983-988
An enzyme-assisted extraction used to extract all species of selenium in rice sample and a sensitive analytical method for the determination of ultratrace Se(VI), Se(IV), SeCys2 (selenocystine) and SeMet (selenomethionine) with capillary electrophoresis-inductively coupled plasma mass spectrometry were firstly described in this study. The extraction method is simple, effective and can be used to extract trace selenium compounds in rice with high extraction efficiency and no altering its species. The analytical method has a detection limit of 0.1-0.9 ng Se/mL, and can be used to determine trace Se(VI), Se(IV), SeCys2 and SeMet in rice directly without any derivatization and pre-concentration. With the help of above methods, we have successfully determined Se(VI), Se(IV), SeCys2 and SeMet in selenium-enriched rice within 18 min with a recovery of 90-103% and a RSD (relative standard deviation, n = 6) of 3-7%. Our results indicated that selenium-enriched rice contained only one species of selenium, SeMet, and its concentration is in range of 0.136-0.143 μg Se/g dried weight. The proposed method providing a realistic approach for the nutritional and toxical evaluation of different selenium compounds in nutritional supplements.  相似文献   

2.
3.
赵云强  郑进平  杨明伟  付凤富 《色谱》2011,29(2):111-114
建立了一种利用毛细管电泳与电感耦合等离子体质谱联用技术(CE-ICP-MS)分析检测6种不同形态砷化合物的方法。详细研究了缓冲溶液的种类、pH值和浓度,分离电压以及进样时间等因素对6种砷化合物的分离度、灵敏度和重现性等的影响。结果表明,在最佳条件下,三价砷(As3+)、一甲基砷(MMA)、二甲基砷(DMA)、五价砷(As5+)、砷胆碱(AsC)和砷甜菜碱(AsB)6种化合物在25 min内得到完全分离。6次平行测定中,6种砷化合物峰面积的相对标准偏差(RSD)为3%~5%,检出限(以As计)(3倍信噪比)为0.08~0.12 μg/L。应用该方法成功地对海带中6种砷化合物进行了分析,回收率为90%~103%。该方法具有耗时短、灵敏度高、样品消耗量少、稳定性好等优点,可用于藻类样品中不同形态砷化合物的分析。  相似文献   

4.
Strong cation-exchange chromatography (SCX-HPLC) was used in conjunction with inductively coupled plasma mass spectrometry (ICP-MS) to investigate cationic selenium species present in leaf extract of wild-type Brassica juncea supplemented with selenite. Total amount of Se accumulated by the leaves was found to be 352 microg g(-1). Cation-exchange solid-phase extraction (SCX-SPE) was used to pre-concentrate the cationic species present in the leaf extract. Methylselenomethionine (MeSeMet) and dimethylselenoniumproprionate (DMSeP) were synthesized and characterized by electrospray quadrupole time-of-flight MS (ESI-QTOF-MS). Laboratory synthesized and commercially available standards were used in chromatographic studies to identify the Se species in the leaf extract through retention time comparisons and standard addition method. Major cationic selenium species identified in the present study were MeSeMet and methylselenocysteine (MeSeCys) while selenomethionine (SeMet) was found in minor quantities.  相似文献   

5.
For selenium speciation analysis, the hyphenation of chromatographic separation with element-specific detection has proved a useful technique. A powerful separation system, which is capable of resolving several biologically and environmentally important selenium compounds in a single column, is greatly needed. However, that has been difficult to achieve. In this paper eight selenium compounds, namely, selenite [Se(IV)], selenate [Se(VI)], selenocystine (SeCys), selenourea (SeUr), selenomethionine (SeMet), selenoethionine (SeEt), selenocystamine (SeCM) and trimethylselenonium ion (TMSe+), were separated by using mixed ion-pair reagents containing 2.5 mM sodium 1-butanesulfonate and 8 mM tetramethylammonium hydroxide as a mobile phase. The separation of these anionic, cationic and neutral organic selenium compounds on a LiChrosorb RP18 reversed-phase column took only 18 min at a flow-rate of 1.0 ml/min with isocratic elution, and baseline separation among the six organic Se compounds was achieved. Inductively coupled plasma mass spectrometry (ICP-MS) was employed as element-specific detection. A comparison of ICP-MS signal intensity obtained with a Barbington-type nebulizer and with an ultrasonic nebulizer (USN) was made. Different signal enhancement factors were observed for the various selenium compounds when a USN was used. The speciation technique was successfully applied to the study on chemical forms of selenium in a selenium nutritional supplement. Selenomethionine was found to be the predominant constituent of selenium in the supplement.  相似文献   

6.
Selenium species, selenite, selenate, selenomethionine (Semet), seneloethionine (Seet) and trimethylselenonium ion (TmSe) were separated in aqueous solution using a gel-permeation (polyvinyl alcohol-based resin) GS-220 column by eluting with 25 mM tetramethylammonium hydroxide and 25 mM malonic acid at pH 7.9. The GS-220 column coupled with inductively coupled plasma mass spectrometry was used for the separation, identification, and quantification of selenium compounds present in certified reference material (CRM) No. 18 human urine from the National Institute for Environmental Studies in Japan (NIES). Spiking of the authentic standard to the urine and use of a silica-based LC-SCX cation-exchange column validated the peak of selenium compounds. High concentrations of chloride and bromide in the urine eluted from the GS-220 column formed molecular ions 40Ar37Cl+ and 81Br1H+ in the plasma, and these molecular ions created additional peaks in the chromatograms when 77Se and 82Se isotopes were monitored respectively. Thus, both the isotopes were selected concurrently for signal monitoring to eliminate the interfering signals. On the LC-SCX column, chloride and bromide were eluted with selenate and complicated its determination, but the peak of TmSe was baseline separated from rest of the Se compounds. Two unknown Se compounds were detected in both the columns. An additional Se compound having the same retention time as that of Semet was detected on the LC-SCX column. Peaks of selenite, selenate, TmSe and unknown selenium compounds in the urine were baseline separated on the GS-220 column, and were free from interferences. Therefore, the GS-220 column was used for the determination of selenium compounds in NIES CRM No. 18. Unknown Se compounds were the predominant selenium species followed by selenite, TmSe and selenate. The estimated value of TmSe as Se, by the standard additions method using the GS-220 column, was 3.42 +/- 0.17 microg l(-1) and was in good agreement with the LC-SCX value [3.38 +/- 0.21 (n=5) microg l(-1)].  相似文献   

7.
There is considerable evidence that toxicity and physiological behavior of arsenic depends on its chemical forms. Arsenic speciation became therefore the subject of increasing interest in recent years. A sensitive method for the determination of arsenic species has been developed. The proposed procedure involves the use of high-performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Six arsenic compounds were separated by anion-exchange chromatography with isocratic elution using tartaric acid as mobile phase with an elution order: arsenocholine, arsenobetaine, dimethylarsinic acid, methylarsonic acid, arsenous acid and arsenic acid. The chromatographic parameters affecting the separation of the arsenic species were optimized. Analytical characterization of the method has been realized with standard solutions. The detection limits for six arsenic compounds were from 0.04 to 0.6 g/L as As element. The repeatability (expressed by R.S.D) was better than 7% for all investigated compounds. The HPLC-ICP-MS system was successfully applied to the determination of arsenic compounds in environmental and biological samples in g/L level.  相似文献   

8.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic in edible oil. The arsenic species studied include arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine. Gradient elution using (NH(4))(2)CO(3) and methanol at pH 8.5 allowed the chromatographic separation of all species in less than 8 min. Effluents from the IC column were delivered to the nebulizer of ICP-MS for the determination of arsenic. The concentrations of arsenic species have been determined in several used and fresh vegetable oil samples. In this study, a microwave-assisted extraction method was used for the extraction of arsenic species from oil samples. The extraction efficiency was better than 92% and the recoveries from spiked samples were in the range of 90-105%. The precision between sample replicates was better than 8% for all determinations. The limits of detection were in the range of 0.008-0.024 ng mL(-1) for various arsenic species based on peak height, which corresponded to 0.08-0.24 ng g(-1) in the original oil sample. The major arsenic species in the used oil samples varied based on the food items cooked.  相似文献   

9.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample. Received: 4 September 1996 / Accepted: 12 December 1996  相似文献   

10.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample.  相似文献   

11.
Capillary electrophoresis-dynamic reaction cell inductively coupled plasma mass spectrometry (CE-DRC-ICP-MS) for the speciation of iron(III/II), vanadium(V/IV) and chromium(VI/III) is described. Two different CE migration modes were employed for separating the six metal ions using pre-capillary complexation. One is counter-electroosmotic mode in which iron(III/II) and vanadium(V/IV) ions were well separated using a 60 cm x 75 microm i.d. fused silica capillary. The voltage was set at +22 kV and a 15 mmol l(-1) tris(hydroxymethyl)aminomethane (Tris) buffer (pH 8.75) containing 0.5 mmol l(-1) ethylenediaminetetraacetic acid (EDTA) and 0.5 mmol l(-1) ortho-phenanthroline (phen) was used as the electrophoretic buffer. The other is co-electroosmotic mode in which chromium(VI/III) ions were well separated while the applied voltage was set at -22 kV and a 10 mmol l(-1) ammonium citrate buffer (pH 7.7) containing 0.5 mmol l(-1) diethylenetriaminepentaacetic acid (DTPA) and 0.01% polybrene was used as the electrophoretic buffer. The mass spectra were measured at m/z 51, 52 and 56 for V. Cr and Fe, respectively. The interfering polyatomic ions of 35Cl16O+, 40Ar12C+ and 40Ar16O+ on 51V+, 52Cr+ and 56Fe+ determination were reduced in intensity significantly by using NH3 as the reaction cell gas in the DRC. The detection limits were in the range of 0.1-0.5, 0.4-1.3 and 1.2-1.7 ng ml(-1) for V, Cr and Fe, respectively. Applications of the method for the speciation of V, Cr and Fe in wastewater were demonstrated. The recoveries were in the range of 92-120% for various species.  相似文献   

12.
Le XC  Cullen WR  Reimer KJ 《Talanta》1994,41(4):495-502
An arsenic specific detection system utilizing on-line microwave digestion and hydride generation atomic absorption spectrometry (MD/HGAAS) is described for arsenic speciation by using high performance liquid chromatography (HPLC). Both ion exchange chromatography and ion pair chromatography have been studied for the separation of arsenite, arsenate, monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), and arsenobetaine (AB). When the commonly used mobile phases, phosphate and carbonate buffers at pH 7.5, are used on an anion exchange column, arsenite and AB co-elute. However, selective determination of these two arsenic compounds can be achieved by using the new detection system. Partial separation between arsenite and AB can be achieved by increasing the mobile phase pH to 10.3 and by using a polymer based anion exchange column. The detection limit obtained by using anion exchange chromatography with MD/HGAAS detection is approximately 10 ng/ml (or 200 pg for a 20-mul sample injection) for arsenite, DMAA and AB, 15 ng/ml (or 300 pg) for MMAA, and 20 ng/ml (or 400 pg) for arsenate. Complete separation of the five arsenic compounds is achieved on a reversed phase C18 column by using sodium heptanesulfonate as ion pair reagent. Comparable resolution between chromatographic peaks is obtained by using MD/HGAAS detection and inductively coupled plasma mass spectrometry (ICPMS) detection.  相似文献   

13.
A speciation method utilizing ion chromatography coupled with inductively coupled plasma mass spectrometry is described for simultaneous analysis of eight halogenides and oxyhalogens: chloride, chlorite, chlorate, perchlorate, bromide, bromate, iodide and iodate. The method was applied for the analysis of drinking water samples collected from water treatment plants in areas in Finland, which are known to have high bromine concentrations in ground water. Water samples collected before and after disinfection were analyzed to get information about potential species conversion as a result of purification. Chloride and chlorate were the chlorine species found in these water samples, and iodine existed as both iodate and iodide. In the case of bromine, species conversion had taken place, since total bromine concentrations were increased during disinfection but bromide concentrations were decreased. No bromate was observed in the samples. The detection limits for all the chlorine species studied were 500 μg/l, for bromine species studied 10 μg/l, for iodide 0.1 μg/l and for iodate 0.2 μg/l.  相似文献   

14.
GuiDi Yang  JinHua Xu  GuoNan Chen 《Talanta》2010,80(5):1913-1918
A microwave-assisted extraction used to extract trace triorganotin from aquatic organisms and a sensitive analytical method for the determination of ultratrace triorganotin (namely trimethyltin, triethyltin, tripropyltin and tributyltin) with capillary electrophoresis-inductively coupled plasma mass spectrometry were firstly described in this study. The extraction method is simple, effective and can be used to extract trace triorganotin in aquatic organisms within several min. The analytical method has a much lower detection limit of 0.2-0.7 ng Sn/mL for triorganotin compounds, and can be used to determine trace triorganotin in aquatic organisms directly without any derivatization and preconcentration. Using above methods, we have successfully determined trimethyltin, triethyltin, tripropyltin and tributyltin in dried Mya arenaria Linnaeus and Corbicula fluminea within 17 min with a recovery of 93-104% and a RSD (relative standard deviation, n = 6) of 2-5%. Our results showed that dried M. arenaria Linnaeus contained an extremely high tributyltin of 5.1 μg Sn/g dried weight, indicating that it may be a good biomarker for the organotin pollution in ocean.  相似文献   

15.
High-performance capillary electrophoresis is applied to the separation of different inorganic and organic arsenic and selenium compounds. In comparison with UV-detection, an approach with conductivity detection is described expecting higher sensitivity and universality. In this case the capillary was statically modified with CTAB before the electromigration procedure. The separation was performed with an electrolyte system consisting of CHES and Triton X-100. Detection limits of 0.06 mg/L or lower were obtained for As(V) and Se(VI). Water samples of an arsenic-polluted tailing of tin mining processes were analysed for anions as well as arsenic and selenium species.  相似文献   

16.
High-performance capillary electrophoresis is applied to the separation of different inorganic and organic arsenic and selenium compounds. In comparison with UV-detection, an approach with conductivity detection is described expecting higher sensitivity and universality. In this case the capillary was statically modified with CTAB before the electromigration procedure. The separation was performed with an electrolyte system consisting of CHES and Triton X-100. Detection limits of 0.06 mg/L or lower were obtained for As(V) and Se(VI). Water samples of an arsenic-polluted tailing of tin mining processes were analysed for anions as well as arsenic and selenium species.  相似文献   

17.
An application of coupled column ion chromatography (IC)-inductively coupled plasma mass spectrometry (ICP-MS) is presented for speciation of chromium in waste waters. By coupling an anion column with a cation column, both the cationic Cr(III) and anionic Cr(VI) species can be analyzed with detection limits below 0.5 μg/1. The separation of the interfering ions (chloride, chlorate, perchlorate, sulphate, sulphite, sulphide, thiosulphate, carbonate, cyanide and some organic compounds) from the chromium peaks is discussed, and the use of different chromium isotopes for data acquisition is compared. Based on the results, m/z 52 was considered as an ideal isotope for speciation of chromium in waste waters by the coupled column IC-ICP-MS, because it did not suffer from polyatomic interferences and due to the high sensitivity for chromium. The analysis of the waste water samples should be performed as soon as possible after sampling according to the stability tests of the species.  相似文献   

18.
Hau J  Devaud S  Blank I 《Electrophoresis》2004,25(13):2077-2083
Capillary electrophoresis coupled to mass spectrometry (CE-MS) is reported for the first time as an alternative and powerful analytical method for the characterization and monitoring of N-substituted 1-amino-1-deoxyketoses (Amadori compounds). It allows rapid separation and identification of Amadori compounds, while benefiting from the well-known advantages of MS, such as specificity and sensitivity. Amadori compounds of several amino acids, such as glycine, valine, isoleucine, methionine, proline, and phenylalanine, as well as a cysteine-derived compound, were separated and/or discriminated using CE-MS/MS under standard conditions. The technique may also be useful to study the stability and degradation kinetics of other labile charged Maillard intermediates that play an important role in food and medical science.  相似文献   

19.
Yeh CF  Jiang SJ 《Electrophoresis》2005,26(7-8):1615-1621
A capillary electrophoresis-inductively coupled plasma-mass spectrometric (CE-ICP-MS) method for the speciation of six arsenic compounds, namely arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid, dimethylarsinic acid, arsenobetaine and arsenocholine is described. The separation has been achieved on a 70 cm length x 75 microm ID fused-silica capillary. The electrophoretic buffer used was 15 mM Tris (pH 9.0) containing 15 mM sodium dodecyl sulfate (SDS), while the applied voltage was set at +22 kV. The arsenic species in biological tissues were extracted into 80% v/v methanol-water mixture, put in a closed centrifuge tube and kept in a water bath, using microwaves at 80 degrees C for 3 min. The extraction efficiencies of individual arsenic species added to the sample at 0.5 microg As/g level were between 96% and 107%, except for As(III), for which it was 89% and 77% for oyster and fish samples, respectively. The detection limits of the species studied were in the range 0.3-0.5 ng As/mL. The procedure has been applied for the speciation analysis of two reference materials, namely dogfish muscle tissue (NRCC DORM-2) and oyster tissue (NIST SRM 1566a), and two real-world samples.  相似文献   

20.
Supercritical fluid chromatography with inductively coupled plasma-mass spectrometric detection is a new and useful technique for the analysis of organometallic compounds. An interface has been developed for coupling these techniques. The interface is compact, easy to assembel, and causes minimal disruption to either instrument. A series of organotin, organoarsenic, and organorion compounds has been used to evaluate the interface and ICPMS as a detector for SFC. The effect of analyte concentration and restrictor temperature on peak intensity has been investigated and the effect of the mobile phase on the plasma has also been studied to assess background interference from changes in the plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号