首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 256 毫秒
1.
A commercially available enzyme-linked immunosorbent assay (ELISA) test kit developed for detection of cooked beef in meat samples was used to determine appropriate heat treatment of rendered materials. An improved extraction procedure increased the absolute difference in R-values between 2 rendered materials treated under different conditions (average temperature 129 and 134 degrees C, respectively). To evaluate the influence of the main sterilization parameters on ELISA results, a factorial design approach was used. The parameters investigated were temperature, time, particle size, and meat composition. Lean meat samples containing beef and pork were sterilized under strictly controlled conditions in a laboratory autoclave. The experiments demonstrated that the R-values obtained with the ELISA test kit for beef are strongly influenced by temperature and time, whereas particle size has a minor influence. The proportion of bovine material did not have any impact on R-values. Autoclave-processed lean meat samples were analyzed by using an ELISA test kit for pork, which was validated in a collaborative trial. The ELISA test kit for pork proved to be more sensitive for the investigated parameters, thus verifying and extending previous investigations.  相似文献   

2.
An interlaboratory trial was conducted for the validation of an enzyme-linked immunosorbent assay (ELISA) method for determination of appropriate heat treatment of animal meal. A commercially available ELISA test kit developed for the identification of beef in cooked food was used in the study. Twelve laboratories from 7 European countries examined 2 different analytical protocols to establish the most appropriate analytical method. Three different samples were used, 2 animal waste materials sterilized at 129 and 134 degrees C (wet conditions), respectively, and a meat and bone meal material processed at dry conditions (maximum temperature, 140 degrees C). Statistical evaluation applying t-statistics showed that the animal meal treated according to European legislation (>133 degrees C) was clearly distinguishable from the 2 other test materials at a 99% confidence level using both analytical protocols. This method can be considered as a complementary test to the immunoassay developed for the detection of pork in cooked food that is already applied in routine analysis for the surveillance of rendering plants.  相似文献   

3.
Egg is one of the 5 major allergenic foods that are responsible for more than 3/4 of food allergies in children. Food-allergic responses can be controlled by avoidance of the offending foods. The applicability of a commercial enzyme-linked immunosorbent assay (ELISA) kit for the detection of egg in food products such as cookies, crackers, pretzels, salad dressings, and raw and cooked noodles was evaluated. A preliminary evaluation of an antibody-based biosensor was also performed. A National Institute of Standards and Technology (NIST) whole dried egg powder reference material, SRM 8415, was used as a standard. A homogeneous and stable aqueous egg suspension was prepared for the evaluation of the performance of the Veratox for Egg Allergen Test (Neogen Corp., Lansing, MI). This test does not detect egg yolk proteins. Each gram of the aqueous dried egg suspension contained 643 microg whole dried egg, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. When cookies, crackers, salad dressings, noodles, and ice cream were spiked at a level of 24 mg/kg SRM 8415, recoveries for whole egg averaged about 28%. All foods containing egg as indicated on the ingredient label were found positive by the Veratox test. No false positives occurred in samples that did not contain eggs. Similar results were obtained using the Naval Research Laboratory (NRL) array biosensor, an evanescent wave fluoroimmunosensor. Results for cooked noodles showed that they contained <1% of the egg found in uncooked noodles. A comparison of extracts from cooked and uncooked noodles by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) revealed differences in protein profiles. The boiling of the noodles could have reduced the immunoreactivity of the egg proteins to the antibodies used in the kit or rendered the egg proteins nonextractable.  相似文献   

4.
An enzyme-linked immunosorbent assay (ELISA) using a monoclonal antibody to a porcine thermal-stable muscle protein was developed for detection of pork in cooked meat products. The assay specifically detects porcine skeletal muscle, but not cardiac muscle, smooth muscle, blood, and nonmuscle organs. No cross-reactivity was observed with common food proteins. Validity of the assay was evaluated with laboratory formulated and commercial meat samples. The detection limit was determined as 0.5% (w/w) pork in heterologous meat mixtures. Overall, intra- and inter-assay coefficients of variation were 5.8 and 7.9%, respectively. The accuracy in analyzing market samples was 100% as verified by product labeling and confirmed by a commercial polycolonal antibody test kit.  相似文献   

5.
In a multilaboratory study, the effectiveness of an alternative method for rapid screening of Listeria species compared to traditional reference methods was demonstrated in a variety of food products. A collaborative study was conducted to compare the VIDAS Listeria species Xpress (LSX) method and the standard cultural methods for the detection of Listeria species in foods. Six food types were tested: vanilla ice cream, cheddar cheese, raw ground beef, frozen green beans, deli turkey, and cooked shrimp. Each food, inoculated with a different Listeria strain at two levels and uninoculated test portions, was analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study 1134 tests were analyzed in the statistical analysis. There were 490 positives by the VIDAS LSX method using the sample boiling step, 483 positives by the VIDAS LSX method using the Heat and Go system, and 439 positives by the standard culture methods. Overall, the Chi-square result for the VIDAS LSX method with boiling for all foods was 7.25, indicating a significant statistical difference between the VIDAS method and the standard methods at the 5% confidence. For the VIDAS LSX method with the Heat and Go system, the Chi-square result for all foods was 5.37, indicating a significant statistical difference between the VIDAS LSX assay with the Heat and Go system and the standard methods at the 5% level of significance. In both cases, the VIDAS method was more sensitive than the standard methods. The LSX method detects Listeria species in foods with negative or presumptive positive results in a minimum of 30 h compared to at least 5 days for the cultural methods. Based on the results of this collaborative study, it is recommended that the VIDAS LSX method be adopted as an AOAC Official Method for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry.  相似文献   

6.
Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.  相似文献   

7.
R L Patterson  S J Jones 《The Analyst》1990,115(5):501-506
An overview of developments that have occurred in meat species identification over the last decade is presented. It starts by noting the different requirements for speciation techniques over the period, describes the complex nature of meat in terms of chemical composition and shows how the chain of events from slaughter to retail gives rise to opportunities for deliberate adulteration or innocent contamination. The limitations of techniques such as electrophoresis and isoelectrofocusing are pointed out where the analysis of mixed meats is concerned; attention then focuses on the range of techniques based on antigen-antibody interactions: agar gel immunodiffusion, counter immuno-electrophoresis and enzyme-linked immunosorbent assay (ELISA) in three formats. The choice of analyte is discussed, firstly for the analyses of raw meat materials and secondly, for heat-processed meat products. In the first example, blood serum proteins are used almost exclusively despite the limitation that their presence does not necessarily denote the presence of the corresponding muscle tissue (meat). For cooked products, a new range of antisera are necessary, based on thermally stable components derived from the tissues. By using different formats of ELISA, it is demonstrated that different responses can be obtained for heat-processed meat versus processed offal, and that determination of a species meat content in a cooked mixed meat product is possible. Techniques for improving the specificity and performance of antisera are discussed briefly, with the future introduction of thermally stable, muscle-specific monoclonal antisera being seen as the way forward.  相似文献   

8.
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.  相似文献   

9.
Meat is a rich source of energy that provides high-value animal protein, fats, vitamins, minerals and trace amounts of carbohydrates. Globally, different types of meats are consumed to fulfill nutritional requirements. However, the increasing burden on the livestock industry has triggered the mixing of high-price meat species with low-quality/-price meat. This work aimed to differentiate different meat samples on the basis of metabolites. The metabolic difference between various meat samples was investigated through Nuclear Magnetic Resonance spectroscopy coupled with multivariate data analysis approaches like principal component analysis (PCA) and orthogonal partial least square-discriminant analysis (OPLS-DA). In total, 37 metabolites were identified in the gluteal muscle tissues of cow, goat, donkey and chicken using 1H-NMR spectroscopy. PCA was found unable to completely differentiate between meat types, whereas OPLS-DA showed an apparent separation and successfully differentiated samples from all four types of meat. Lactate, creatine, choline, acetate, leucine, isoleucine, valine, formate, carnitine, glutamate, 3-hydroxybutyrate and α-mannose were found as the major discriminating metabolites between white (chicken) and red meat (chevon, beef and donkey). However, inosine, lactate, uracil, carnosine, format, pyruvate, carnitine, creatine and acetate were found responsible for differentiating chevon, beef and donkey meat. The relative quantification of differentiating metabolites was performed using one-way ANOVA and Tukey test. Our results showed that NMR-based metabolomics is a powerful tool for the identification of novel signatures (potential biomarkers) to characterize meats from different sources and could potentially be used for quality control purposes in order to differentiate different meat types.  相似文献   

10.
A rehydratable dry-film plating method for Escherichia coli, the Petrifilm E. coli/Coliform (EC) Count Plate in foods, has been compared with the AOAC INTERNATIONAL most probable number (MPN) method. Eleven laboratories participated in the collaborative study. Three E. coli levels in 8 samples each of frozen raw ground turkey, frozen raw ground beef, and frozen cooked fish were tested in duplicate. Mean log counts for the Petrifilm plate procedure were not significantly different from those for the MPN procedure for cooked fish samples inoculated with low or high inocula levels, for samples of raw turkey inoculated at medium level, and for beef inoculated at low, medium, and high levels. Repeatability and reproducibility variances of the Petrifilm EC Plate method recorded at 24 h were as good as or better than those of the MPN method. The dry rehydratable film method for enumerating confirmed E. coli in poultry, meats, and seafood has been adopted first action by AOAC INTERNATIONAL.  相似文献   

11.
A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.  相似文献   

12.
For over ten years, there has been a considerable interest in determination of acrylamide in foodstuffs. It was known that both protein-rich and carbohydrates-rich foods cooked at high-temperatures can cause acrylamide formation. However, carbohydrates-rich foods such as potato chips and biscuit samples have been the common studied foods compared with protein-rich foods such as meat samples.In this study, determination of acrylamide in these two group foods was examined using HPLC-MS. For this purpose, firstly, the parameters that are thought to affect the response in the HPLC-MS analysis were optimized. The optimized conditions were found to be 0.3 ml min− 1 for flow rate of mobile phase, 40 µl for injection volume, 5 °C for column temperature and 70 V for fragmentor potential. The optimized method was applied for the determination of acrylamide levels in Turkish foodstuffs including grilled meat and chicken samples, potato chips, coffee and biscuit. The obtained concentrations for all studied foods were in the range of 20–250 µg kg− 1. The results showed that acrylamide concentrations highly varied depending on the kind of food samples.  相似文献   

13.
A multiplex polymerase chain reaction (PCR) detection method for the simultaneous detection of animal-derived components from deer, cow, sheep, pig and horse in edible meat was established, and a multiplex PCR detection kit for the rapid detection of animal-derived components was developed. According to the mitochondrial cytochrome b (Cyt b) gene of bovine species, sheep species, pig species and horse species and the mitochondrial cytochrome c oxidase subunit I (COX 1) gene of sika deer and red deer as the target gene sequences of primers, the specific primers of five different species were designed, the PCR system was optimized, and the multiplex PCR identification method of five animal-derived components was established. The minimum detection amount was determined by sensitivity test. The results showed that five meat specific amplification bands could be found at the same time in the same reaction system, including 173 bp fragment for venison, 148 bp for beef, 261 bp for pork, 100 bp for mutton and 424 bp for horse, indicating that the method is specific and stable. The minimum detection limit by this method was 1 ng/μL, showing a high sensitivity. According to the different sites in different areas of animal mitochondrial genes, a multiplex PCR detection method was established and a detection kit was developed, and the rapid, sensitive, stable and high-throughput detection of five animal-derived components and adulterated animal components in edible meat can be realized by using the kit.  相似文献   

14.
Consumer demand for both plant products and meat products enriched with plant raw materials is constantly increasing. Therefore, new versatile and reliable methods are needed to find and combat fraudulent practices in processed foods. The objective of this study was to identify oilseed species-specific peptide markers and meat-specific markers that were resistant to processing, for multispecies authentication of different meat and vegan food products using the proteomic LC-MS/MS method. To assess the limit of detection (LOD) for hemp proteins, cooked meatballs consisting of three meat species and hemp cake at a final concentration of up to 7.4% were examined. Hemp addition at a low concentration of below 1% was detected. The LOD for edestin subunits and albumin was 0.9% (w/w), whereas for 7S vicilin-like protein it was 4.2% (w/w). Specific heat-stable peptides unique to hemp seeds, flaxseed, nigella, pumpkin, sesame, and sunflower seeds, as well as guinea fowl, rabbit, pork, and chicken meat, were detected in different meat and vegan foods. Most of the oilseed-specific peptides were identified as processing-resistant markers belonging to 11S globulin subunits, namely conlinin, edestin, helianthinin, pumpkin vicilin-like or late embryogenesis proteins, and sesame legumin-like as well as 2S albumins and oleosin isoforms or selected enzymic proteins.  相似文献   

15.
The objective of this study was to utilize linear discriminant analysis (LDA) in the interpretation of capillary electrophoresis-sodium dodecyl sulfate polymer-filled capillary gel electrophoresis (CE-SDS) meat protein profiles for the identification of meat species. The specific objectives were 1) to collect quantitative data on water-soluble and saline-soluble proteins of different meat species obtained by CE-SDS and 2) to apply LDA on collected CE-SDS protein data for the development of a pattern recognition statistical model useful in the differentiation of meat species. Samples were raw beef top and eye round, boneless fresh pork ham and loin, turkey leg and breast meat, and mechanically deboned turkey meat collected on six different occasions, making a total of 42 samples. Additionally, 14 samples were used as test samples to determine the classification ability of the procedure. Quantitative protein data obtained by CE-SDS was used to generate separate LDA models for either water- or saline-soluble protein extracts. Although a saline solution was a more efficient meat protein-extracting agent, as shown by a higher total protein concentration and a larger number of peaks, water-soluble CE-SDS protein profiles gave more distinctive discrimination among meat species. The correct classification given by LDA on water-soluble protein data was 100% for all meat species, except pork (94%). Conversely, the correct classification on saline-soluble protein data was 88% for beef and mechanically deboned turkey meat, and 94% and 100% for turkey and pork meat, respectively. LDA proved to be a useful pattern recognition procedure in the interpretation of CE-SDS protein profiles for the identification of meat species.  相似文献   

16.
An interlaboratory study in 12 laboratories was performed to prove the validation of the ELISA method developed for the quantitative determination of mustard protein in foods. The ELISA kit used for this study is based on rabbit polyclonal antibody. This kit did not produce any false-positive results or cross-reactivity with in-house validation for a broad range of food matrixes with no detectable mustard protein. All participants obtained the Mustard ELISA kit with standard operational procedures, a list of samples, samples, and a protocol for recording test results. The study included 15 food samples and two spiked samples. Seven food matrix samples of zero mustard content and four samples with mustard declared as an ingredient showed mustard protein content lower than that of the first standard (0.42 mg/kg). Four samples with mustard declared as an ingredient revealed mustard protein content above 12.5 mg/kg (the highest standard). The statistical tests (Cochran, Dixon, and Mandel) and analysis of variance were used to evaluate the interlaboratory study results. Repeatability and reproducibility limits, as well as an LOQ (1.8 mg mustard proteins/kg) and LOD (0.5 mg mustard proteins/kg), for the kit were calculated.  相似文献   

17.
Irradiation is the most efficient non-thermal technology for improving hygienic quality and extending the shelf-life of food products. One of the adverse effects of food irradiation, however, is off-flavor production, which significantly affects the sensory preferences for certain foods. In this study, garlic (5%, w/w) and red wine (1:1, w/w) were added to ground beef to increase the radiation sensitivity of pathogens and improve meat odor/flavor. Samples were irradiated at 0 or 5 kGy in the presence of charcoal pack. SPME-GC–MS analysis was performed to measure the changes in the volatile compounds and sensory characteristics of the samples. The amount of total volatile compounds produced from ground beef was greater when the sample was irradiated. When garlic and red wine were added to the ground beef, the amount of volatile compounds significantly increased, and the amount of volatile compounds increased even further after irradiation. However, when the samples were irradiated with charcoal pack, the amount of volatile compounds decreased significantly. Sensory evaluation indicated that charcoal pack significantly increased the odor preferences for both irradiated and non-irradiated ground beef added with garlic. These results indicated that addition of charcoal pack to ground beef could reduce off-odor problems induced by irradiation, and this effect was consistent even when certain additives such as garlic and red wine were added.  相似文献   

18.
19.
Machiels D  Istasse L 《Talanta》2003,61(4):529-537
The aroma profile of cooked beef meat has been investigated by solid-phase microextraction (SPME) combined with gas chromatography-mass spectrometry (GC-MS). Out of more than 200 volatile compounds, 36 key odour-active compounds were selected for analysis. Several extraction times, desorption times, temperature conditions and fibre types were tested to achieve a fast and reproducible extraction, and a representative analysis of the aroma profile of cooked beef. Extraction conditions and fibre type significantly affected the majority of the target compounds. Divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre presented a better reproducibility at all extraction times and extracted more efficiently the less volatile compounds than the carboxen-polydimethylsiloxane (CAR-PDMS) fibre. The high molecular weight compounds seemed to achieve faster the equilibrium between the headspace and DVB-CAR-PDMS fibre. The use of SPME was shown to be a simple, sensitive, selective, representative, fast, and low-cost method for the evaluation of key odour-active compounds in cooked beef meat, even if further research on quantitative analysis of volatiles using SPME on solid samples has to be done.  相似文献   

20.
A collaborative study was conducted to validate new enrichment methods for the TECRA Listeria Visual Immunoassay (TLVIA). These new methods incorporate a newly formulated medium, TECRA Listeria Enrichrment Broth, which does not contain the highly toxic antifungal agent, cycloheximide. The new procedures will provide an alternative to the enrichment procedures described in AOAC Method 995.22. Three food types (raw ground beef, lettuce, and ice cream) were analyzed in the United States, and 2 food types (cooked turkey and cooked fish fillets) were analyzed in Australasia. Thirty collaborators participated in the study, 16 in Australasia and 14 in the United States. With the exception of one batch of ground beef, comparison of the proportion of positive test portions (p > or = 0.05) showed no significant difference between the TLVIA and the reference method for the 5 foods at 3 inoculation levels. For the one batch of naturally contaminated raw ground beef, the TLVIA gave significantly more confirmed positive results than the reference method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号