共查询到20条相似文献,搜索用时 15 毫秒
1.
Silvia Dulanská Boris Remenec Ján Bilohuščin Miroslav Labaška Bianka Horváthová Andrej Mátel 《Journal of Radioanalytical and Nuclear Chemistry》2013,298(1):439-442
This paper describes the use of IBC′s AnaLig®Pu-02 molecular recognition technology product to effectively and selectively pre-concentrate, separate and recover plutonium from urine samples. This method uses two-stage column separations consisting of two different commercial products, Eichrom’s Pre-filter Material and AnaLig®Pu-02 resin from IBC Advanced Technologies. By eliminating the co-precipitation techniques and the ashing steps to remove residual organics, the analysis time was reduced significantly. The method was successfully tested by adding known activities of reference solutions of 242Pu and 239Pu to urine samples. 相似文献
2.
Silvia Dulanská Igor Antalík Miroslav Labaška Boris Remenec Andrej Mátel 《Journal of Radioanalytical and Nuclear Chemistry》2013,295(3):1635-1639
A rapid separation method has been developed which allows measurement of plutonium, americium and strontium isotopes in the high active sample from CBRN Training and Testing Centre in Zemianske Kostolany (Slovakia) with high chemical recoveries and effective removal of matrix interferences. This method uses different commercial products stacked AnaLig® Pu-02, AnaLig® Sr-01 and DGA® Resin cartridges from IBC Advanced Technologies and Eichrom Technologies. The method allows rapid separation of plutonium, strontium and americium using a single multi-stage column in the vacuum box (cartridge technology) with rapid flow rates to minimize sample separation time. The 239,240Pu, 238Pu and 241Am were determined by alpha spectroscopy, 90Sr was counted on TRICARB 2900 TR by Cerenkov counting of its progeny 90Y. 相似文献
3.
Silvia Dulanská Boris Remenec Dušan Galanda Mojmír Němec Lívia Dvorská 《Journal of Radioanalytical and Nuclear Chemistry》2012,293(3):965-971
In this paper rapid separation methods for strontium determination using molecular recognition technology products 3M Empore? Sr disc, AnaLig® Sr-01 and extraction chromatography Sr® Resin were presented and statistical tested. The methods performance was investigated by analysis of NPL (High Alpha–Beta 2003) and (High Alpha–Beta 2005) intercomparison samples. The presented results were evaluated as correct for all experimental data. We used linear regression (with regression diagnostics), t test and the mean of variable using 90Sr with 3M Empore? Sr disc, AnaLig® Sr-01 and Sr® Resin. 相似文献
4.
5.
Silvia Dulanská Boris Remenec L’ubomír Mátel Erik Durkot 《Journal of Radioanalytical and Nuclear Chemistry》2012,293(1):81-85
A rapid separation method has been developed which allows measurement of plutonium, americium and strontium isotopes in the radioactive sludge from Nuclear power plant A1 Jaslovske Bohunice (NPP A1) with high chemical recoveries and effective removal of matrix interferences. This method uses different commercial products stacked AnaLig? Pu02, AnaLig? Sr01 and TRU? Resin cartridges from IBC Advanced Technologies and Eichrom Technologies. The method allows the rapid separation of plutonium, strontium and americium using a single multi-stage column in the vacuum box (cartridge technology) with rapid flow rates to minimize sample separation time. The 239,240Pu, 238Pu and 241Am were determined by alpha spectroscopy, 90Sr was counted on TRICARB 2900 TR by Cerenkov counting of its progeny 90Y. 相似文献
6.
Sezin Erarpat Süleyman Bodur Merve Fırat Ayyıldız Ömer Tahir Günkara Fatih Erulaş Dotse Selali Chormey Fatma Turak Türkan Börklü Budak Sezgin Bakırdere 《Biomedical chromatography : BMC》2020,34(10):e4915
This work presents a sensitive and rapid analytical method for the determination of oxcarbazepine in human plasma and urine samples. A vortex-assisted switchable hydrophilicity solvent-based liquid phase microextraction (VA–SHS–LPME) was used to preconcentrate oxcarbazepine from the samples before the determination by gas chromatography mass spectrometry. The switchable hydrophilicity solvent was synthesized by protonating N,N-dimethylbenzylamine with carbon dioxide to make it totally miscible with an equivalent volume of water. Parameters of the VA–SHS–LPME method including volume of switchable hydrophilicity solvent, concentration/volume of sodium hydroxide and vortex period were systematically optimized. Under the optimum conditions, good linearity ranging from 27.03 to 353.47 μg/kg was obtained for the analyte. Limit of detection and quantitation values were found to be 6.2 and 21 μg/kg (mass base), respectively. The relative standard deviation was calculated as 6.9% for six replicate measurements of the lowest concentration of the calibration plot. Satisfactory recovery results were calculated in the range of 97–100% for human plasma and urine samples spiked at five different concentrations. 相似文献
7.
Salgado-Petinal C Lamas JP Garcia-Jares C Llompart M Cela R 《Analytical and bioanalytical chemistry》2005,382(6):1351-1359
In this paper a solid-phase microextraction–gas chromatography–mass spectrometry (SPME–GC–MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)—venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline—in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL–1 urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified. 相似文献
8.
《Analytical letters》2012,45(1):152-163
AbstractA simple, sensitive, and selective fluorimetric method is reported for the determination of β-carotene in various food samples. Three fluorescent dyes, including fluorescein (F), eosin B (EB), and Congo red (CR), were characterized in a series of measurements to optimize the analytical response for the reliable, suitable, and sustainable determination of β-carotene. 3′,6′-Dihydroxyspiro[isobenzofuran-1(3H),9′-[9H]xanthen]-3-one, commonly known as fluorescein, was selected for the fluorimetric determination of β-carotene using a phosphate buffer. Under the optimum experimental conditions, β-carotene was determined across a range from 0.54 to 536.87?mg L?1 with a detection limit equal to 0.47?mg L?1. The novel method was demonstrated to be easy to use, cost effective, rapid, and less complex compared to a standard protocol that involves a time-consuming extraction followed by an expensive HPLC determination. 相似文献
9.
Yadollah Yamini Mahnaz Ghambarian Ali Esrafili Najmeh Yazdanfar Morteza Moradi 《International journal of environmental analytical chemistry》2013,93(13):1493-1505
The objective of the present study was to develop and validate a rapid, highly sensitive, and reliable extraction method to determine acrylamide in water samples. The method was based on the derivatisation of the acrylamide in the presence of KBr, HBr and saturated Br2 solution into 2,3-dibromopropionamide and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–electron capture detection (GC–ECD) of the analyte. Different parameters that affect the DLLME process such as types and volumes of disperser solvent, ionic strength of aqueous solution and extraction time were investigated and optimised. Under optimal conditions, excellent linearity was obtained between concentration of acrylamide and the response of ECD with correlation of determination (R2) of 0.9999. The precision of the method, which was determined by calculating the relative standard deviations (RSD) of the at least three replicate measurements, was 3.6%. The method presented in this study is sensitive enough for the determination of acrylamide in different water samples with the limit of detection (LOD) value of 1?ng?L?1. The mean percentage recoveries exceeded 91% for all of spiking levels in the real water samples. The results obtained from DLLME method are validated by EPA method 8032A. 相似文献
10.
Mara Gasparini Michele CuratoloWalter Assini Eros BozzoniNadia Tognoli Guglielmo Dusi 《Journal of chromatography. A》2009,1216(46):8059-8066
A confirmatory method for the simultaneous determination of nandrolone (α and β) and trenbolone (α and β) in urine samples by liquid chromatography electrospray mass spectrometry (LC–MS-MS) was developed. After an enzymatic deconjugation, the urine was subjected to a one-step cleanup on a commercially available immunoaffinity chromatography cartridge. The analytes were detected by liquid chromatography–positive ion electrospray tandem mass spectrometry using deuterium labelled internal standards. The analytical procedure was applicable to bovine and swine urine samples. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results obtained showed that the method was suitable for statutory residues testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. The decision limits (CCα) obtained, were between 0.54 and 0.60 μg L−1; the recovery was above 64% for all the analytes. Repeatability was between 1.6% and 5.7% and within-laboratory reproducibility between 1.6% and 6.0% for all the steroids. 相似文献
11.
12.
Hossein Ali Mashayekhi Parviz Abroomand-Azar Mohammad Saber-Tehrani 《International journal of environmental analytical chemistry》2013,93(6):516-524
A rapid and sensitive method has been developed for the determination of biphenyl and biphenyl oxide in water samples using dispersive liquid–liquid microextraction followed by gas chromatography. This method involves the use of an appropriate mixture of extraction solvent (8.0?µL tetrachloroethylene) and disperser solvent (1.0?mL acetonitrile) for the formation of cloudy solution in 5.0?mL aqueous sample containing biphenyl and biphenyl oxide. After extraction, phase separation was performed by centrifugation and biphenyl and biphenyl oxide in sedimented phase (5.0?±?0.3?µL) were determined by gas chromatography-flame ionisation (GC-FID) system. Type of extraction and disperser solvents and their volumes, salt effect on the extraction recovery of biphenyl and biphenyl oxide from aqueous solution have been investigated. Under the optimum conditions and without salt addition, the enrichment factors for biphenyl and biphenyl oxide were 819 and 785, while the extraction recovery were 81.9% and 78.5%, respectively. The linear range was (0.125–100?µg L?1) and limit of detection was (0.015?µg?L?1) for both analytes. The relative standard deviation (RSD, n?=?4) for 5.0?µg?L?1 of analytes were 8.4% and 6.7% for biphenyl and biphenyl oxide, respectively. The relative recoveries of biphenyl and biphenyl oxide from sea, river water and refined water (Paksan company) samples at spiking level of 5.0?µg?L?1 were between 85.0% and 100 %. 相似文献
13.
Cristiane Antoniazzi Camila Alves de Lima Rafael Marangoni Almir Spinelli Eryza Guimarães de Castro 《Journal of Solid State Electrochemistry》2018,22(5):1373-1383
This paper reports the voltammetric determination of 17β-estradiol in urine and buttermilk samples using a simple detector based on a carbon paste electrode (CPE) modified with copper(II) oxide (CuO). The CuO was obtained by the Pechini method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive (EDS), Fourier transform infrared (FTIR), and Raman spectroscopies. Cyclic voltammetry (CV) and square-wave voltammetry (SWV) demonstrated that the CuO-modified carbon paste electrode (CuO/CPE detector) displayed much higher electrocatalytic activity in the 17β-estradiol oxidation reaction than the CPE without modification, exhibiting a low detection limit of 21.0 nmol L?1 with a wide linear range from 60.0 to 800.0 nmol L?1 (R = 0.998). Satisfactory results were obtained for the determination of 17β-estradiol in human urine and buttermilk samples. The proposed electrochemical detector offers high repeatability, stability, fast response, low cost, and potential for practical application in the quantification of this hormone. 相似文献
14.
A method for enantiodiscrimination of α-chiral aldehydes is reported. The method utilizes circular dichroism (CD) spectroscopy and a sensing ensemble composed of 2-(1-methylhydrazinyl) pyridine (1) and Fe(II)(TfO)2. Aldehydes react rapidly with hydrazine (1) to form chiral imines, which form complexes with Fe(II). By monitoring the CD bands above 320 nm, one can determine the enantiomeric excess (ee) values of α-chiral aldehydes with an average absolute error of ±5%. The analysis was fast, and thus can have potential applications in high-throughput screening (HTS) of catalytic asymmetric induction. 相似文献
15.
Ketone handedness was discriminated using circular dichroism (CD) spectroscopy by monitoring the metal-to-ligand charge transfer (MLCT) bands of complexes between [Cu(I)((S)-1)(CH(3)CN)(2)]PF(6) and derivatized α-chiral cyclohexanones (4). This method was able to quantify the enantiomeric excess of unknown samples using a calibration curve, giving an absolute error of ±7%. The analysis was fast, allowing potential application of this assay in high-throughput screening (HTS). 相似文献
16.
Campins Falcó P Tortajada Genaro LA Meseger Lloret S Blasco Gomez F Sevillano Cabeza A Molins Legua C 《Talanta》2001,55(6):1079-1089
The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval was 0.92-50 mg l(-1) and seven samples can be processed per hour by an operator. No previous treatment of the urine sample is necessary. The FI method provides also good results. The lineal interval was 30-100 mg l(-1) and the sample rate was around 20 samples per hour. If increased albumin levels are detected in the urine, standard addition method or the calibration graphs with standards in presence of albumin are needed in order to obtain accurate results when FI method is employed. The obtained accuracy of the both methods allows its application as diagnostic tool to establish the urinary creatinine levels. 相似文献
17.
Silvia Dulanská Boris Remenec Erik Durkot Du?an Galanda ?ubomír Mátel 《Journal of Radioanalytical and Nuclear Chemistry》2012,293(3):847-850
Procedure for analysis of plutonium isotopes in soil samples was developed using a new molecular recognition technology product AnaLig?Pu-02 gel. Extraction chromatography TEVA? Resin was used for purification of plutonium phase to remove thorium impurities which interfere in Pu determination by alpha spectrometry. The performance of the method was successfully tested by analysis of a sand stimulant sample and a soil sample spiked with known activity of 239Pu. The results obtained for procedures were compared in terms of activities and recoveries. 相似文献
18.
Rosales-Conrado N León-González ME Pérez-Arribas LV Polo-Díez LM 《Analytical and bioanalytical chemistry》2008,390(2):759-768
Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity.
Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict
their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids—2,4-dichlorophenoxyacetic
acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic
acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked
human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 °C, with injection of 20 μL
low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array
detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration
range 25–150 μg L−1; recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples
from volunteers were between 3.5 and 6.0 μg L−1. The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without
previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately
resulting in the reduction of the sample-preparation time. 相似文献
19.
Laloup M Fernandez Mdel M Wood M Maes V De Boeck G Vanbeckevoort Y Samyn N 《Analytical and bioanalytical chemistry》2007,388(7):1545-1556
Sedative agents are used to facilitate sexual assault due to their ability to render the victim passive, submissive and unable to resist. The primary pharmacological effect of the benzodiazepine tetrazepam is muscle relaxation, whereas the benzodiazepine diazepam acts on the central nervous system (CNS) exerting mainly sedation effects. Therefore, contrary to tetrazepam, diazepam is an often-abused drug, which can potentially be used as a date-rape drug. In this study, we describe the detection of low amounts of diazepam in Myolastan (Sanofi-Synthelabo S.A., Brussels, Belgium) and Epsipam (Will-Pharma, Wavre, Belgium) 50 mg tablet preparations by LC-MS-MS, GC-FID and HPLC-DAD. Considering the important forensic implication of this finding, a study was conducted with volunteers receiving a single or repeated dosage of Myolastan. Urine, hair and preserved oral fluid samples were analysed using a previously described sensitive and specific LC-MS-MS detection method allowing for the simultaneous quantification of tetrazepam, diazepam, nordiazepam, oxazepam and temazepam. This study demonstrates that diazepam can be observed in urine samples even after a single dose of Myolastan. In addition, maintaining therapy for 1 week results in the detection of both diazepam and nordiazepam in urine samples and of diazepam in the first hair segment. Importantly, comparing urine and hair samples after a single intake of diazepam versus the single and 1 week administration of Myolastan shows that the possible metabolic conversion of tetrazepam to diazepam is a more plausible explanation for the detection of diazepam in biological samples after the intake of Myolastan. As such, these results reveal that the presence of diazepam and/or nordiazepam in biological samples from alleged drug-facilitated assault cases should be interpreted with care. 相似文献