首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
An electrochemiluminescent (ECL) aptamer based method is described for the determination of thrombin. Three-dimensional nitrogen-doped graphene oxide (3D-NGO) was placed on a glassy carbon electrode (GCE) to provide an electrode surface that displays excellent electrical conductivity and acts as a strong emitter of ECL. The modified electrode was further coated with chitosan via electrodeposition. Finally, the amino-modified aptamer was immobilized on the modified GCE. The interaction between thrombin and aptamer results in a decrease in ECL. The assay has a linear response in the 1 fM to 1 nM thrombin concentration range and a 0.25 fM lower detection limit (at an S/N ratio of 3). The method was applied to the determination of thrombin in spiked human plasma samples, and recoveries ranged between 94 and 105% (with RSDs of <3.6%). The calibration plot was recorded at potential and wavelength of fluorescence emission (wavelength:?445 nm; potential:?0 to -2 V).
Graphical abstract A bare glassy carbon electrode (GCE) does not display electrochemiluminescence (ECL). If, however, nitrogen-doped graphene quantum dots, chitosan, and three-dimensional nitrogen-doped graphene oxide (NGQD-chitosan/3D-NGO) are electrodeposited on the GCE, strong ECL can be observed. The ECL intensity decreased after aptamer and bovine serum albumin (BSA) were dropped onto the electrode (curve a). However, the ECL further decreases after addition of thrombin (TB; curve b).
  相似文献   

2.
A novel electrochemiluminescent (ECL) method for highly sensitive detection of gene mutations was designed based on the amplification strategy of dual-functional aluminum(III). A film composed of nafion and polyaniline (Nafion-PANI) was placed onto glassy carbon electrode (GCE) in order to improve conductivity and stability, and then cadmium sulfide quantum dots (CdS QDs) were attached as an ECL label. Al(III) was introduced in order to enhance the ECL signal intensity of the CdS QDs by filling the surface electronic defects of CdS QDs. The Al(III) ions also assist by improving sensitivity by promoting the electron transfer at the GCE and by retaining plenty of single-stranded DNA (ssDNA). The ECL is generated at typically ?1.5 V in the presence of containing K2S2O8. Compared to conventional ECL based DNA biosensors, the one described here – based on the use of dually functional Al(III) ions – enables ssDNA to be detected in the 1 f. to 10 nM concentration range, with a 6 f. detection limit. This method was applied to the quantitation of target ssDNA with different mismatching status in human serum. In our perception, it represents a highly attractive tool for the detection of ssDNA and has a particular potential in the diagnosis of hereditary diseases.
Graphical abstract Preparation and schematic illustration of dual-functional aluminum(III)-based electrochemiluminescent for detection of target ssDNA.
  相似文献   

3.
Three-dimensional structures comprising polypyrrole nanowires (PPyNWs) and molecularly imprinted polymer (MIP) were prepared by electropolymerization on the surfaces of a glassy carbon electrode (GCE). The modified GCE possesses both large surface area and good electrocatalytic activity for oxidizing dopamine (DA), and this leads to high sensitivity. The electropolymerized MIP has a large number of accessible surface imprints, and this makes the GCE more selective. Under optimal conditions and at a working voltage of typically 0.23 V (vs. SCE), the calibration plot is linear in the 50 nM to 100 μM DA concentration range, and the limit of detection is 33 nM. The sensor has been successfully applied to the analysis of DA in injections.
Graphical abstract Schematic of a three-dimensional nanocomposite based dopamine sensing platform based on the use of a molecularly imprinted polymer and poly(pyrrole) nanowires. The modified polypyrrole nanowires and molecularly imprinted polymer endowed high electrocatalytic capacity and good selectivity for dopamine recognition, respectively.
  相似文献   

4.
We describe a chemical exfoliation method for the preparation of MoS2 nanosheets. The nanosheets were incorporated into poly(3,4-ethylenedioxythiophene) (PEDOT) by electrodeposition on a glassy carbon electrode (GCE) to form a nanocomposite. The modified GCE is shown to enable simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Due to the synergistic effect of MoS2 and PEDOT, this electrode displays better properties in terms of electrocatalytic oxidation of AA, DA and UA than pure PEDOT, which is illustrated by cyclic voltammetry and differential pulse voltammetry (DPV). Under optimum conditions and at pH 7.4, the respective sensitivities and best working potentials are as follows: AA: 1.20 A?mM?1?m?2, 30 mV; DA: 36.40 A?mM?1?m?2, 210 mV; UA: 105.17 A?mM?1?m?2, 350 mV. The calculated detection limits for AA, DA and UA are 5.83 μM, 0.52 μM and 0.95 μM, respectively. The modified electrode was applied to the detection of the three species in human urine samples and gave satisfactory results.
Graphical abstract MoS2 nanosheets were prepared by a facile chemical exfoliation method. MoS2 and poly(3,4-ethylenedioxythiophene) nanocomposite modified glassy carbon electrodes were fabricated, which are shown to enable simultaneous determination of ascorbic acid, dopamine and uric acid with high sensitivity and selectivity.
  相似文献   

5.
This paper describes an electrochemiluminescent (ECL) based method for chiral recognition and detection of both glutamate (Glu) enantiomers. The luminophore luminol (Lum) was used as both the reductant and stabilizer of Ag nanoparticles (AgNP-Lum) which were combined with carbon quantum dots (C-dots) and placed on a glassy carbon electrode (GCE) along with the enzyme glutamate oxidase (GluOx). The use of these materials is found to result in strong amplification of ECL. The nanomaterials used were characterized by transmission electron microscopy (TEM) and Fourier transform infrared (FTIR). The stepwise fabrication of the electrode was verified by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions and by applying a typical potential of 0.6 V, the ECL increases linearly in the 5.0 μM to 5.0 mM Glu concentration range, with a 1.6 μM lower detection limit and satisfactory selectivity. A Glu logic gate idea has been designed that is based on this enzymatic biosensor.
Graphical abstract Schematic presentation of the electrochemiluminescent (ECL) biosensor. A glassy carbon electrode (GCE) was modified with C-dots and silver nanoparticles which were deoxidized by luminol (AgNP-Lum) for enzymatic specific detection.
  相似文献   

6.
A dual-responsive sandwich-type immunosensor is described for the detection of interleukin 6 (IL-6) by combining electrochemiluminescent (ECL) and electrochemical (EC) detection based on the use of two kinds of TiO2 mesocrystal nanoarchitectures. A composite was prepared from TiO2 (anatase) mesocages (AMCs) and a carboxy-terminated ionic liquid (CTIL) and then placed on a glassy carbon electrode (GCE). In the next step, the ECL probe Ru(bpy)3(II) and antibody against IL-6 (Ab1) were immobilized on the GCE. Octahedral anatase TiO2 mesocrystals (OAMs) served as the matrix for immobilizing acid phosphatase (ACP) and secondary antibody (Ab2) labeled with horseradish peroxidase (HRP) to form a bioconjugate of type Ab2-HRP/ACP/OAMs. It was self-assembled on the GCE by immunobinding. 1-Naphthol, which is produced in-situ on the surface of the GCE due to the hydrolysis of added 1-naphthyl phosphate by ACP, is oxidized by HRP in the presence of added H2O2. This results in an electrochemical signal (typically measured at 0.4 V vs. Ag/AgCl) that increases linearly in the 10 fg·mL?1 to 90 ng·mL?1 IL-6 concentration range with a detection limit of 0.32 fg·mL?1. Secondly, the oxidation product of 1-naphthol quenches the ECL emission of Ru(bpy)32+. This leads to a decrease in ECL intensity which is linear in the 10 ag·mL?1 to 90 ng·mL?1 concentration range, with a detection limit of 3.5 ag·mL?1. The method exhibits satisfying selectivity and good reproducibility which demonstrates its potential in clinical testing and diagnosis.
Graphical abstract A dual-responsive sandwich-type immunosensor was fabricated for the detection of interleukin 6 by combining electrochemiluminescence and electrochemical detection based on the use of two kinds of TiO2 mesocrystal nanoarchitectures.
  相似文献   

7.
The authors describe an enzyme-free amperometric method for the determination of glucose at nanomolar levels at near neutral pH values. A hybrid nanostructure composed of molybdenum disulfide and copper sulfide (MoS2-CuS) was prepared using L-cysteine as both the sulfur donor and the reducing agent. The nanohybrid was then immobilized on a glassy carbon electrode (GCE) by incorporating it into a film of poly(vinyl butyral). Transmission electron microscopy and Raman spectroscopy were utilized to characterize the MoS2-CuS nanohybrids. Three modified GCEs (MoS2/GCE, CuS/GCE and MoS2-CuS/GCE) were investigated with respect to their sensitivity to glucose, and the MoS2-CuS/GCE was found to perform best in displaying a limit of detection as low as 0.3 μM in pH 7.2 buffer at an applied potential of +0.18 V (versus Ag/AgCl). The repeatability and intermediate precision are below 7.0% at 0.05, 0.5 and 1.0 mM concentration levels. The method was applied to the determination of glucose in spiked human serum samples, and recoveries were between 92.3 and 110.7%. This detection scheme is rapid and cost-effective. Natural enzymes and additional electron mediators are not required.
Graphical Abstract MoS2-CuS hybrid nanostructures on a glassy carbon electrode were utilized for enzyme-free sensing of glucose at nanomolar levels.
  相似文献   

8.
A glassy carbon electrode (GCE) was modified with poly(L-arginine) (P-Arg), reduced graphene oxide (rGO) and gold nanoparticle (AuNP) to obtain an electrode for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp) in the presence of ascorbic acid (AA). The modified GCE was prepared via subsequent ‘layer-by-layer’ deposition using an electrochemical technique. The surface morphology of the modified electrode was studied by scanning electron microscopy, and electrochemical characterizations were carried out via cyclic voltammetry and electrochemical impedance spectroscopy. The modified electrode showed excellent electrocatalytic activity toward DA, 5-HT and L-Trp at pH 7.0. Figures of merit for the differential pulse voltammetric reponse are as follows: (a) Response to DA is linear in two intervals, viz. 1.0–50 nM and 1.0–50 μM DA concentration range, the typical working voltage is 202 mV (vs. Ag/AgCl), and the detection limit is 1 nM (at an S/N ratio of 3). For 5-HT, the respective data are 10 to 500 nM and 1.0 to 10 μM, 381 mV, and 30 nM. For L-Trp, the respective data are 10–70 nM and 10–100 μM, 719 mV, and 0.1 μM. The modified GCE is fairly selective. It was successfully applied to the simultaneous determination of DA, 5-HT, and L-Trp in spiked urine samples, and high recovery rates were found.
Graphical abstract Schematic presentation of the voltammetric sensor based on a glassy carbon electrode modified with poly(L-arginine), reduced graphene oxide (rGO) and gold nanoparticle (GCE/P-Arg/ErGO/AuNP) for simultaneous determination of dopamine (DA), serotonin (5-HT) and L-tryptophan (L-Trp).
  相似文献   

9.
The authors describe an electrochemiluminescence (ECL) based aptasensor for the pesticide aldicarb. The method is based on effective ECL energy transfer that occurs between the ruthenium(II) bipyridyl complex [referred to as Ru(bpy)3 2+] and gold nanoparticles (AuNPs). More specifically, multiwalled carbon nanotubes were modified with dendritic poly(L-arginine) labeled with Ru(bpy)3 2+, and the aptamers were taggedd with AuNPs. In the absence of aldicarb, the ECL emitted by Ru(bpy)3 2+ is enhanced by AuNPs under peak wavelength at at a wavelength of 610 nm. In the presence of aldicarb, the capture and competitive binding of aldicarb to the DNA aptamers causes their separation from the DPA6/Ru(bpy)3 2+/MWCNT. As a result, ECL intensity decreases linearly with increasing aldicarb concentrations in the range between 40 pM and 4 nM, with a detection limit of 9.6 pM. This aptamer switch is highly sensitive, selective and inexpensive. Conceivably, it can be adapted to formats for the determination of other pesticide residues by using different DNA aptamers.
Graphical abstract Schematic of the procedure for aptamer-based detection of aldicarb using the ECL signal of the Ru(bpy)3 2+ amplified by gold nanoparticles. This assay has high sensitivity, good selectivity, and low cost. It can presumably be transferred to other pesticide detection schemes.
  相似文献   

10.
The authors describe an electrochemiluminescent (ECL) DNA biosensor that is based on the use of gold nanoparticles (AuNPs) modified with graphite-like carbon nitride nanosheets (g-C3N4 NSs) and carrying a DNA probe. In parallel, nanoparticles prepared from gold-platinum (Au/Pt) alloy and carbon nanotubes (CNTs) were placed on a glassy carbon electrode (GCE). Once the g-C3N4 NHs hybridize with DNA-modified AuNPs, they exhibit strong and stable cathodic ECL activity. The Au/Pt-CNTs were prepared by electrochemical deposition of Au/Pt on the surface of the CNTs in order to warrant good electrical conductivity. On hybridization of immobilized capture probe (S1), target DNA (S2) and labeled signal probe (S3), a sandwich-type DNA complex is formed that produces a stable ECL emission at a typical applied voltage of ?1.18 V and in the presence of peroxodisulfate. Under optimized conditions, the method has a response to target DNA that is linearly related to the logarithm of its concentration in the range between 0.04 f. and 50 pM, with a 0.018 f. detection limit.
Graphical abstract Schematic presentation of an electrochemiluminescent DNA biosensor based on two-dimensional graphite-like carbon nitride nanosheets (g-C3N4 NSs) hybridized with gold nanoparticles. Abbreviations: MCH: 6-mercapto-1-hexanol; S1: Capture probe; S2: target DNA. 
  相似文献   

11.
The authors describe an amperometric sensor for dopamine (DA) by employing olive-like Fe2O3 microspheres (OFMs) as the electrocatalyst for DA oxidization. The OFMs were prepared by using a protein templated method. The structure and properties of the OFMs were characterized by scanning electron microscopy, X-ray powder diffraction, energy dispersive x-ray spectroscopy, cyclic voltammetry and electrochemical impedance spectroscopy. The OFMs possess excellent catalytic activity towards DA oxidization due to their unique morphology. The sensor responds to DA within less than 5 s. The sensor, best operated at a voltage of +0.2 V (vs. SCE) responds linearly in the 0.2 to 115 μM DA concentration range and has a 30 nM detection limit. The selectivity, reproducibility and long-term stability of the sensor are acceptable. It performs well when applied to spiked human urine samples.
Graphical abstract Olive-like Fe2O3 microspheres (OFMs), synthesized using egg white as template, display excellent catalytic activity towards dopamine (DA) oxidization due to their unique morphology. They were applied for DA detection using the amperometric technique. The electrochemical sensor exhibited a high sensitivity and a 30 nM detection limit. DAQ: dopaquinone.
  相似文献   

12.
The authors describe a composite material prepared from carbon nanohorns and poly(2-aminopyridine) that was obtained by electrochemical polymerization of 2-aminopyridine on carbon nanohorns. The material was used to modify a glassy carbon electrode (GCE) to obtain a sensor for non-enzymatic determination of hydrogen peroxide. The modified GCE was characterized by cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry. The modified electrode is shown to display excellent electrical conductivity and catalytic activity towards hydrogen peroxide, mainly due to the large specific surface area of carbon nanohorns, the good electron charge transfer properties resulting from the use of poly(2-aminopyridine), and their synergistic effect. The response of the modified GCE (best operated at a working potential of ?0.45 V vs. SCE) to H2O2 is linear in the 0.05 to 8 mM concentration range. The limits of detection (LOD) and quantitation (LOQ) are 3.6 μM and 12.4 μM, respectively. The electrode is selective, stable and reproducible, this making it a promising tool for non-enzymatic determination of hydrogen peroxide.
Graphical abstract A glassy carbon electrode was modified with carbon nanohorns and poly(2-aminopyridine) to obtain a sensor for H2O2
  相似文献   

13.
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at ?50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
Graphical abstract Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid is achieved on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups, through anodic treatment of glassy carbon and silane chemistry.
  相似文献   

14.
A nanocomposite consisting of cetyltrimethylammonium bromide (CTAB), Fe3O4 nanoparticles and reduced graphene oxide (CTAB-Fe3O4-rGO) was prepared, characterized, and used to modify the surface of a glassy carbon electrode (GCE). The voltammetric response of the modified GCE to 4-nonylphenol (NPh) was investigated by cyclic voltammetry and revealed a strong peak at around 0.57 V (vs. SCE). Under optimum conditions, the calibration plot is linear in the ranges from 0.03 to 7.0 μM and from 7.0 to 15.0 μM, with a 8 nM detection limit which is lower that that of many other methods. The modified electrode has excellent fabrication reproducibility and was applied to the determination of NPh in spiked real water samples to give recoveries (at a spiking level of 1 μM) between 102.1 and 99.1%.
Graphical abstract A nanocomposite consisting of cetyltrimethylammonium bromide (CTAB), Fe3O4 nanoparticles and reduced graphene oxide (CTAB-Fe3O4-rGO) was prepared and used to modify the surface of a glassy carbon electrode (GCE) for the differential pulse voltammetric (DPV) determination of 4-nonylphenol (NPh).
  相似文献   

15.
A glassy carbon electrode (GCE) was modified with a nanocomposite consisting of tetraoctylammonium bromide (TOAB), C60 fullerene, and palladium nanorods (PdNRs). The PdNRs were hydrothermally prepared and had a typical width of 20 ± 2 nm. The nanocomposite forms stable films on the GCE and exhibits a reversible redox pair for the C60/C60 ? system while rendering the surface to be positively charged. The modified GCE was applied to fabricate an electrochemical biosensor for detecting acetylcholinesterase (AChE) by measurement of the amount of thiocholine formed from acetylthiocholine, best at a working voltage of ?0.19 V (vs. SCE). The detection scheme is based on (a) measurement of the activity of ethyl paraoxon-inhibited AChE, and (b) measurement of AChE activity after reactivation with pralidoxime (2-PAM). Compared to the conventional methods using acetylthiocholine as a substrate, the dual method presented here provides data on the AChE activity after inhibition and subsequent reactivation, thereby yielding credible data on reactivated enzyme activity. The linear analytical range for AChE activity extends from 2.5 U L?1 to 250 kU·L?1, and the detection limit is 0.83 U L?1.
Graphical abstract Cyclovoltammetric acetylcholinesterase (AChE) activity assay is constructed based on the palladium nanorods composited with functionalized C60 fullerene (PdNR/C60 + TOAB), which aims to measure the signal change between ethyl paraoxon-inhibited and subsequent pralidoxime (2-PAM)-reactivated AChE activity.
  相似文献   

16.
A binary nanocomposite of type copper tungstate and polyaniline (CuWO4@PANI) is described that was obtained by single step polymerization on the surface of a glassy carbon electrode (GCE). The resulting electrode is shown to be a viable tool for voltammetric sensing of quercetin (Qn) in blood, urine and certain food samples. The nanocomposite was characterized by UV-visible absorption spectroscopy, Fourier-transform infrared spectroscopy, thermogravimetric analysis, X-ray diffraction and high-resolution transmission electron microscopy. Differential pulse voltammetry was applied to quantify Qn, typically at the relatively low working potential of 0.15 V (vs. Ag/AgCl). The modified GCE has a wide analytical range (0.001–0.500 μM) and a low detection limit (1.2 nM). The sensor is reproducible, selective and stable. This makes it suitable for determination of Qn in real samples without complicated sample pretreatment.
Graphical abstract Schematic of a copper tungstate and polyaniline nanocomposite modified glassy carbon electrode for voltammetric determination of quercetin in real samples.
  相似文献   

17.
A composite material obtained by ultrasonication of graphene oxide (GO) and multi-walled carbon nanotubes (MWCNTs) was loaded with manganese dioxide (MnO2), poly(diallyldimethylammonium chloride) and gold nanoparticles (AuNPs), and the resulting multilayer hybrid films were deposited on a glassy carbon electrode (GCE). The microstructure, composition and electrochemical behavior of the composite and the modified GCE were characterized by transmission electron microscopy, Raman spectra, energy-dispersive X-ray spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The electrode induces efficient electrocatalytic oxidation of dopamine at a rather low working voltage of 0.22 V (vs. SCE) at neutral pH values. The response is linear in the 0.5 μM to 2.5 mM concentration range, the sensitivity is 233.4 μA·mM ̄1·cm ̄2, and the detection limit is 0.17 μM at an SNR of 3. The sensor is well reproducible and stable. It displays high selectivity over ascorbic acid, uric acid and glucose even if these are present in comparable concentrations.
Graphical abstract Gold nanoparticles were self-assembled onto the surface of the MnO2 decorated graphene oxide-carbon nanotubes composites with poly(diallyldimethylammonium chloride) (PDDA) as a coupling agent. Further, a sensitive electrochemical sensor of dopamine was developed via immobilizing this nanocomposite on a glassy carbon electrode (GCE).
  相似文献   

18.
The authors describe a method for signal amplification of label-free voltammetric immunosensors. A glassy carbon electrode (GCE) was modified with Prussian Blue-platinum nanoparticles (PB-PtNPs) as a redox-active species that gives a strong amperometric signal at 0.18 V (vs. Ag/AgCl). Benefitting from the excellent electrical conductivity and the strong catalytic activity to H2O2, the modified GCE gives a strongly enhanced signal. The PB-PtNPs were incorporated into a polyaniline (PANI) hydrogel to further enhance the signal. The signal response of the PB-PtNP-PANI/GCE is larger by a factor of 7.6 than that of PB-PtNP/GCE. In order to further improve electrical conductivity and immobilize antibody, gold nanoparticles (AuNPs) were deposited on the surface of the PB-PtNP-PANI hydrogel. The AuNP-PB-PtNP-PANI hydrogel nanocomposite on the GCE was used in an immunosensor for the model analyte carcinoma antigen 125 (CA125), a biomarker for epithelial ovarian cancer, by immobilizing the respective antibody on the modified GCE. A linear response found for the 0.01 to 5000 U mL?1 CA125 concentration range, with a detection limit of 4.4 mU mL?1 (at an S/N ratio of 3). The electrochemical sensitivity is as high as 119.76 μA·(U/mL)?1·cm?2. The detection of CA125 in human serum showed satisfactory accuracy compared to a commercial chemiluminescent microparticle immunoassay (CMIA).
Graphical abstract Schematic of a nanocomposites consisting of gold nanoparticles, Prussian Blue, platinum nanoparticles and polyaniline hydrogel as a signal multi-amplification sensing substrate for the ultrasensitive immuno detection of carcinoma antigen 125 (CA125).
  相似文献   

19.
Various carbon nanomaterials for use in anodic stripping voltammetric analysis of Hg(II), Cu(II), Pb(II) and Cd(II) are screened. Graphene, carbon nanotubes, carbon nanofibers and fullerene (C60), dispersed in chitosan (Chit) aqueous solution, are used to modify a glassy carbon electrode (GCE). The fullerene-chitosan modified GCE (C60-Chit/GCE) displays superior performance in terms of simultaneous determination of the above ions. The electrodes and materials are characterized by electrochemical impedance spectroscopy, cyclic voltammetry, scanning electron microscopy, Raman spectroscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The excellent performance of C60-Chit/GCE is attributed to the good electrical conductivity, large surface area, strong adsorption affinity and unique crystalline structure of C60. Using differential pulse anodic stripping voltammetry, the assay has the following features for Hg(II), Cu(II), Pb(II) and Cd(II), respectively: (a) Peak voltages of +0.14, ?0.11, ?0.58 and???0.82 V (vs SCE); (b) linear ranges extending from 0.01–6.0 μM, 0.05–6.0 μM, 0.005–6.0 μM and 0.5–9.0 μM; and (c), detection limits (3σ method) of 3 nM (0.6 ppb), 14 nM (0.9 ppb), 1 nM (0.2 ppb) and 21 nM (2.4 ppb). Moreover, the modified GCE is well reproducible and suitable for long-term usage. The method was successfully applied to the simultaneous determination of these ions in spiked foodstuff.
Graphical abstract Compared with graphene, carbon nanotubes and carbon nanofibers, an electrode modified with fullerene in chitosan electrode displays superior performance for the simultaneous anodic stripping voltammetric detection of Hg(II), Cu(II), Pb(II) and Cd(II).
  相似文献   

20.
The authors describe an electrochemical approach for the preparation of a glassy carbon electrode (GCE) modified with graphene oxide and silver nanodentrites (AgNDs). The coating was obtained by using an aqueous solution containing silver nitrate, phosphate and ammonia. The phosphate anions act as a scaffold for the improved deposition of AgNDs. The effects of deposition potential and time and concentration of electrolyte on the formation of the AgNDs were optimized. The modified GCE displays good electrocatalytic activity towards the oxidation of dissolved hydrazine. The electron transfer coefficient and diffusion coefficient are 0.60 and 4.64 × 10?5 cm2 s?1 respectively. The electrode exhibits a linear response over the 100 nM to 670 μM hydrazine concentration range and a detection limit (LOD) of 33 nM. The sensitivity of the modified electrode is 2077 μA mM?1 cm?2 at a typical working voltage of 0.1 V (vs Ag/AgCl). This LOD is much lower than that of the allowable concentration of hydrazine in drinking water as defined by the US EPA and the WHO.
Graphical abstract Schematic of the 2-step fabrication of a glassy carbon electrode (GCE) modified with graphene oxide (GO) and silver nanodendrites (AgND) for use in a hydrazine sensor. First, Ag3PO4 is formed by adding AgNO3 and phosphate. Secondly, the formed Ag3PO4 is converted to a colorless complex by adding ammonia and by electrolytic growth of AgND on the GO/GCE.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏