首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 693 毫秒
1.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions—in some cases solutions made of tablets—were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.  相似文献   

2.
Electrospray ionization combined with tandem mass spectrometry was applied to a study of some representative chlorinated and nitrated isoflavones-potential metabolites of isoflavones in inflammatory cells. Upon collision-induced dissociation of deprotonated [M - H](-) ions of these compounds, a number of structurally characteristic product ions were produced. The product ion analysis of 3'- and 8-chlorodaidzein in the tandom mass spectra led to ready differentiation of these isomers. 3-Nitro derivatives of both genistein and daidzein have product ions due to the losses of HNO(2) and two OH groups. Chlorinated derivatives of isoflavones were detected in cell-based experiments and their structures were proposed by comparing the tandem mass spectra of their product ions with those of standards. This work provides a suitable analytical basis to aid the characterization of chlorinated and nitrated metabolites in studies in vivo and in vitro.  相似文献   

3.
Fragmentation mechanisms of protonated chalcone and its derivatives with different functional groups were investigated by atmospheric pressure chemical ionization with tandem mass spectrometry (MS/MS). The major fragmentation pathways were loss of the phenyl group from the A or B ring, combined with loss of CO. Losses of H(2)O and CO from the precursor ions of [M+H](+) are proposed to occur via rearrangements. Elimination of water from protonated chalcones was observed in all the title compounds to yield a stable ion but it was difficult to obtain skeletal fragmentation of a precursor ion. Loss of CO was found in the MS/MS spectra of all the compounds except the nitro-substituted chalcones. When the [M+H--CO](+) ion was fragmented in the MS/MS experiments, there were distinctive losses of 15 and 28 Da, as the methyl radical and ethylene, respectively. The ion at m/z 130, found only in the nitro-substituted chalcones, was assigned as C(9)H(6)O by Fourier transform ion cyclotron resonance (FTICR)-MS/MS; m/z 130 is a common fragment ion in the electron ionization (EI) spectra of chalcones. In order to more easily distinguish the constitutional isomers of these chalcones, breakdown curves were produced and these provided strong support in this study.  相似文献   

4.
The development of a method for selective detection of nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) among other polycyclic aromatic compounds (PACs) is described. The method is based on electrospray ionization mass spectrometry (ESI-MS), performed with a triple quadrupole analyzer and constant neutral loss (CNL) scanning. When subjected to ESI conditions, nitro-PAHs give rise to M(-), [M - H](-) and [M - H + 16](-) ions, which in turn produce fragments by losing 30 u, most probably NO. Other PACs do not undergo such fragmentations, and these differences can be exploited for selective detection of nitro-PAHs among other PACs. Nitro-PAHs can therefore be monitored through the loss of 30 u occurring under negative ion mode ESI conditions. Toward the full development of a screening method for nitro-PAHs, this article first discusses some general aspects of the negative ion mode full-scan ESI mass spectra obtained for these compounds and other PAH derivatives. Because the extent of observation of the loss of 30 u is sensitive to the ESI conditions used, the effects of ionization parameters such as solvent used, declustering voltage, and solvent flow rate are evaluated and discussed. Setting these parameters is very important, especially when interfacing a high performance liquid chromatography (HPLC) system with the ESI source of a triple quadrupole mass spectrometer. Preliminary results of on-line microbore HPLC/ESI-MS separations of PAC standards are presented, and elution/ionization conditions discussed.  相似文献   

5.
GC‐MS analysis was performed on the coking sludge from a coking wastewater treatment plant (WWTP) to allow detailed chemical characterization of polycyclic aromatic hydrocarbons (PAHs). The identification and characterization of the isomers of PAHs was based on a positive match of mass spectral data of their isomers with mass spectra databases or based on a comparison of electron impact ionization mass spectra and retention times of target compounds with those reference compounds. In total, 160 PAH compounds including numerous N‐, O‐, S‐, OH‐, and Cl‐containing derivatives were positively identified for the first time. Quantitative analysis of target compounds was performed in the selected ion‐monitoring mode using the internal standard method. The total concentrations of selected compounds in the coking sludge samples from the anaerobic tank, aerobic tank, hydrolytic tank, and secondary clarifier of the WWTP ranged from 1690 ± 585 to 6690 ± 522 mg/kg, which were much higher than those in other industrial and municipal sludges. PAHs with four and five rings were found to be the dominant compounds, and diagnostic ratios of these compounds suggested that they had the characteristics of coal combustion and pyrolysis.  相似文献   

6.
Traditionally, the screening of unknown pesticides in food has been accomplished by GC/MS methods using conventional library searching routines. However, many of the new polar and thermally labile pesticides and their degradates are more readily and easily analyzed by LC/MS methods and no searchable libraries currently exist (with the exception of some user libraries, which are limited). Therefore, there is a need for LC/MS approaches to detect unknown non-target pesticides in food. This report develops an identification scheme using a combination of LC/MS time-of-flight (accurate mass) and LC/MS ion trap MS (MS/MS) with searching of empirical formulas generated through accurate mass and a ChemIndex database or Merck Index database. The approach is different than conventional library searching of fragment ions. The concept here consists of four parts. First is the initial detection of a possible unknown pesticide in actual market-place vegetable extracts (tomato skins) using accurate mass and generating empirical formulas. Second is searching either the Merck Index database on CD (10,000 compounds) or the ChemIndex (77,000 compounds) for possible structures. Third is MS/MS of the unknown pesticide in the tomato-skin extract followed by fragment ion identification using chemical drawing software and comparison with accurate-mass ion fragments. Fourth is the verification with authentic standards, if available. Three examples of unknown, non-target pesticides are shown using a tomato-skin extract from an actual market place sample. Limitations of the approach are discussed including the use of A + 2 isotope signatures, extended databases, lack of authentic standards, and natural product unknowns in food extracts.  相似文献   

7.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns.The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS.The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers.  相似文献   

8.
Searchable MS/MS spectra libraries, constructed using the results of liquid chromatography coupled with electrospray ionization (ESI) tandem mass spectrometry (LC/MS/MS) with data-dependent acquisition on an ion trap mass spectrometer, are presented with regard to the identification and confirmation of a variety of closely related flavonoids in a set of biological samples. Flavonoids were found to exhibit a maximum amount of structurally specific MS/MS spectra at 45% of normalized collision energy on the instrument used, without wideband activation. These MS/MS spectra were then searched automatically against a 297-substance MS/MS library that contains many previously acquired spectra of standard flavonoids. The possible applications of this powerful technique to biological samples are also discussed. Daidzein and genistein were identified through the MS/MS spectra library while searching through LC/MS/MS data for plant and microbial extracts. Moreover, these compounds proved completely distinguishable from other flavonoids of closely related structures in the MS/MS spectra library, using the NIST MS search program. The applicability of the library-searchable spectra at low concentrations was demonstrated by successful identification of daidzein and genistein at 0.05 and 0.5 microg/mL, respectively.  相似文献   

9.
从充分利用气相色谱/质谱(GC/MS)提供的信息来鉴定GC流出组分的目的出发,并以脂肪醇分析为例讨论了GC保留指数在MS谱图解析及MS鉴定结果的合理性检验方面的作用。总结了GC保留的同系物规律、极性规律、加和规律及异构物规律来指导MS谱图解析。提出了含氧化合物官能团相对于-CH2-质量数的保留指数附加贡献值辅助MS确定化合物的类别。同时采用了GC/MS中选择离子检测方法(SIM)在分子离子峰受噪音干扰或太弱以至完全未观测到时来进一步佐证其相对分子质量。  相似文献   

10.
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers.  相似文献   

11.
The inter‐instrument and inter‐laboratory transferability of a tandem mass spectral reference library originally built on a quadrupole‐quadrupole‐time‐of‐flight instrument was examined. The library consisted of 3759 MS/MS spectra collected from 402 reference compounds applying several different collision‐energy values for fragmentation. In the course of the multicenter study, 22 test compounds were sent to three different laboratories, where 418 tandem mass spectra were acquired using four different instruments from two manufacturers. The study covered the following types of tandem mass spectrometers: quadrupole‐quadrupole‐time‐of‐flight, quadrupole‐quadrupole‐linear ion trap, quadrupole‐quadrupole‐quadrupole, and linear ion trap‐Fourier transform ion cyclotron resonance mass spectrometer. In each participating laboratory, optimized instrumental parameters were gathered solely from routinely applied workflows. No standardization procedure was applied to increase the inter‐instrument comparability of MS/MS spectra. The acquired tandem mass spectra were matched against the established reference library using a sophisticated matching algorithm, which is presented in detail in a companion paper. Correct answers, meaning that the correct compound was retrieved as top hit, were obtained in 98.1% of cases. For the remaining 1.9% of spectra, the correct compound was matched at second rank. The observed high percentage of correct assignments clearly suggests that the developed mass spectral library search approach is to a large extent platform independent. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
Like many new designer drugs of abuse, synthetic cannabinoids (SC) have structural or positional isomers which may or may not all be regulated under law. Differences in acute toxicity may exist between isomers which impose further burden in the fields of forensic toxicology, medicine and legislation. Isomer differentiation therefore becomes crucial from these standpoints as new designer drugs continuously emerge with just minor positional modifications to their preexisting analogs. The aim of this study was to differentiate the positional isomers of JWH‐081. Purchased standard compounds of JWH‐081 and its positional isomers were analyzed by gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS) first in scan mode to investigate those isomers who could be differentiated by EI scan spectra. Isomers with identical or near‐identical EI spectra were further subjected to GC‐tandem mass spectrometry (MS/MS) analysis with appropriate precursor ions. EI scan was able to distinguish 3 of the 7 isomers: 2‐methoxy, 7‐methoxy and 8‐methoxy. The remaining isomers exhibited near‐identical spectra; hence, MS/MS was performed by selecting m/z 185 and 157 as precursor ions. 3‐Methoxy and 5‐methoxy isomers produced characteristic product ions that enabled the differentiation between them. Product ion spectrum of 6‐methoxy isomer resembled that of JWH‐081; however, the relative ion intensities were clearly different from one another. The combination of EI scan and MS/MS allowed for the regioisomeric differentiation of the targeted compounds in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
In contrast to libraries with highly reproducible gas chromatography electron ionization mass spectra, current liquid chromatography (LC–MS) libraries are limited to specific instrument types. Therefore, the aim of the study was to prove whether a recently developed linear ion trap (LIT) LC–MSn screening approach and reference library can be transferred to an LC–MS/MS system with a quadrupole‐LIT hybrid mass analyzer using SmileMS, a sophisticated search algorithm. The LIT reference library was built with MS² and MS³ wideband spectra recorded on a ThermoFisher LXQ LIT with electrospray ionization in positive mode and full‐scan data‐dependent acquisition (DDA). Collision parameter optimizations, including different scan types and energies, were performed on an Applied Biosystems QTRAP 4000 system using electrospray ionization in positive mode and full‐scan DDA. Modified library sets were generated to improve the detection of a compound by the used search algorithm. Additionally, 100 authentic human urine samples were screened by both systems for proof of applicability. In the applicability study, 533 compounds were detected by the LXQ and 477 by the QTRAP system using enhanced product ion scan and a modified database. The presented data showed that the LIT screening approach and reference library could be used successfully on a QTRAP instrument with some limitations. These should be overcome by further optimizations regarding DDA settings for better sensitivity and further library modifications to reduce spectra mismatches. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
In vivo nitration of tyrosine residues is a post-translational modification mediated by peroxynitrite that may be involved in a number of diseases. The aim of this study was to evaluate possibilities for site-specific detection of tyrosine nitration by mass spectrometry. Angiotensin II and bovine serum albumin (BSA) nitrated with tetranitromethane (TNM) were used as model compounds. Three strategies were investigated: (i) analysis of single peptides and protein digests by matrix-assisted laser desorption/ionization (MALDI) peptide mass mapping, (ii) peptide mass mapping by electrospray ionization (ESI) mass spectrometry and (iii) screening for nitration by selective detection of the immonium ion of nitrotyrosine by precursor ion scanning with subsequent sequencing of the modified peptides. The MALDI time-of-flight mass spectrum of nitrated angiotensin II showed an unexpected prompt fragmentation involving the nitro group, in contrast to ESI-MS, where no fragmentation of nitrated angiotensin II was observed. The ESI mass spectra showed that mono- and dinitrated angiotensin II were obtained after treatment with TNM. ESI-MS/MS revealed that the mononitrated angiotensin II was nitrated on the side-chain of tyrosine. The dinitrated angiotensin II contained two nitro groups on the tyrosine residue. Nitration of BSA was confirmed by Western blotting with an antibody against nitrotyrosine and the sites for nitration were investigated by peptide mass mapping after in-gel digestion. Direct mass mapping by ESI revealed that two peptides were nitrated. Precursor ion scanning for the immonium ion for nitrotyrosine revealed two additional partially nitrated peptides. Based on the studies with the two model compounds, we suggest that the investigation of in vivo nitration of tyrosine and identification of nitrated peptides might be performed by precursor ion scanning for the specific immonium ion at m/z 181.06 combined with ESI-MS/MS for identification of the specific nitration sites.  相似文献   

15.
In order to assess and maintain the quality of surface waters, target compound monitoring is often not sufficient. Many unknown micro-contaminants are present in water, originating in municipal, industrial or agricultural effluents. Some of these might pose a risk to drinking water production and consequently to human health. The possibilities of screening surface water and identification of these non-target water pollutants with modern data acquisition possibilities of hybrid quadrupole-orthogonal acceleration time of flight mass spectrometers (Q-TOF), such as data-dependent MS to MS/MS switching were investigated. Using model compounds, a procedure for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening of water extracts was developed, enabling the detection and identification of compounds at levels < or = 0.25 microg/l in surface water. Based on the accurate mass the elemental compositions for the precursor and product ions are calculated. The calculated chemical formulae are searched against the Merck index, the NIST library, an own database containing about 2,500 water pollutants (pesticides and other contaminants) as well as a CI-CID library containing tandem MS spectra of about 100 water contaminants. The developed approach was applied for the identification of unknown compounds, present in native surface water extract. For three of these compounds, structures were proposed. Confirmation of the proposed structures with standards was beyond the scope of this study.  相似文献   

16.
气相色谱QSRR研究在质谱谱库检索定性中的应用   总被引:1,自引:0,他引:1  
对质谱谱图相似的多取代烷基苯各位置异构体,根据一种从苯、单取代烷基苯及双取代烷基苯保留指数预测相关多取代烷基苯保留指数的方法,测定了基础化合物在OV-1毛细管柱上的保留指数,预测了相关多取代烷基苯在OV-1上的保留指数。利用该保留数据,结合质谱,给予了正确定性,从而解决了质谱谱库检索定性时对于各位置异构体难于定性的困难。  相似文献   

17.
Fixed-energy sequential tandem mass spectrometry (MS(n)) capabilities offered by quadrupole ion trap instruments have been explored in a systematic study of six isomers of Gal-Fucalpha-OBenzyl disaccharides. Under collision-induced dissociation (CID), sodiated molecular species generated in the positive-ion electrospray ionization mode yield simple and predictable mass spectra. Information on interglycosidic linkages and configurations can be deduced from the relative intensities of the selected diagnostic fragments arising from the glycosidic bond cleavages and corroborated by the fragments arising from cross-ring cleavages. As the CID patterns are not dependent on the number of prior tandem mass spectrometric steps, structures can be unambiguously assigned by matching the spectra with a library. The rules governing the fragmentation behavior of this class of oligosaccharides were tested for a representative isomeric disaccharide, Glcbeta1,3Fucalpha-OAllyl. The findings establish a basis for using MS(n) with a quadrupole ion trap instrument to elucidate structures of hexose-fucose subunits from more complicated oligosaccharides. Energy-resolved mass spectra were also acquired by CID tandem triple-quadrupole mass spectrometry. The breakdown behavior of the molecular ions revealed patterns which could differentiate stereoisomers of Gal-Fuc disaccharides over a range of collision energy from 20 to 50 eV.  相似文献   

18.
This work presents a strategy for elucidation of unknown migrants from plastic food contact materials (baby bottles) using a combination of analytical techniques in an untargeted approach. First, gas chromatography (GC) coupled to mass spectrometry (MS) in electron ionisation mode was used to identify migrants through spectral library matching. When no acceptable match was obtained, a second analysis by GC‐(electron ionisation) high resolution mass spectrometry time of flight (TOF) was applied to obtain accurate mass fragmentation spectra and isotopic patterns. Databases were then searched to find a possible elemental composition for the unknown compounds. Finally, a GC hybrid quadrupole‐TOF‐MS with an atmospheric pressure chemical ionisation source was used to obtain the molecular ion or the protonated molecule. Accurate mass data also provided additional information on the fragmentation behaviour as two acquisition functions with different collision energies were available (MSE approach). In the low‐energy function, limited fragmentation took place, whereas for the high‐energy function, fragmentation was enhanced. For less volatile unknowns, ultra‐high pressure liquid chromatography‐quadrupole‐TOF‐MS was additionally applied. Using a home‐made database containing common migrating compounds and plastic additives, tentative identification was made for several positive findings based on accurate mass of the (de)protonated molecule, product ion fragments and characteristic isotopic ions. Six illustrative examples are shown to demonstrate the modus operandi and the difficulties encountered during identification. The combination of these techniques was proven to be a powerful tool for the elucidation of unknown migrating compounds from plastic baby bottles. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
In order to quickly confirm a potentially hazardous psychoactive designer drug (a compound in which part of the molecular structure of a stimulant or narcotic has been modified), we created a psychoactive drugs data library by performing analysis using liquid chromatography with photodiode array spectrophotometry (LC/PDA) and gas chromatography-mass spectrometry (GC/MS). The data in this library consist of the LC capacity factor (k′) ratios in relation to the internal standard, the ultraviolet (UV) spectra and the MS spectra of 104 compounds. By performing a comparative study of the data in this report with the analytical data for commercial and illegal drug products, it is possible to quickly identify the psychoactive designer drugs in 205 purchased products by using the library. Further, it is possible to analogize the structure of drugs for which there is no matching data in the library using similar data.Furthermore, when structural isomers of controlled substances have detected from the presented library, similarity of their biological effects on human will be predicted, thus leading to regulate their public circulation. Examples of these types of isomers include, for instance, the narcotic 3,4,5-trimethoxyamphetamine (TMA) and its positional isomers 2,4,5-trimethoxyamphetamine (TMA-2) and 2,4,6-trimethoxyamphetamine (TMA-6), or the narcotic 1-(3-chlorophenyl)piperazine (3CPP) and its isomers 1-(o-chlorophenyl)piperazine (2CPP) and 1-(p-chlorophenyl)piperazine (4CPP). Differentiation of these compounds is necessary in regulating them, and we report here the results of a study of a method to confirm these compounds using the present library.  相似文献   

20.
An automated liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method is presented for the screening and confirmation of 16 beta-blocking drugs in clinical and autopsy urine samples. The described method involved C(18) solid phase extraction, LC separation and MS analysis on a triple-stage quadrupole mass analyser. Samples were initially pre-screened for the presence of any beta-blocking drugs using LC/MS with selected ion monitoring. Any compounds tentatively identified as beta-blocking drugs on the basis of their LC retention time and protonated molecular ion were then automatedly subjected to a second analysis in which the relevant MS/MS product ion mass spectra were acquired. These product ion mass spectra were then automatically searched against a 400-substance mass spectral library containing previously acquired beta-blocking drugs. The results demonstrated that library search of beta-blocking drugs in urine with MS/MS product ion mass spectra was more reliable and produced fewer false negatives than library searching with mass spectra derived from single-stage quadrupole MS. The limits of identification in the MS/MS product ion scan ranged from 0.02 mg l(-1) for carvedilol to 1.2 mg l(-1) for pindolol, the majority of the values being below 0.2 mg l(-1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号