首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
提出了用浓硝酸沉淀并分离大量基体钼,ICP-AES同时测定钼酸铵中14个杂质元素的方法,考虑了钼基体、酸度、谱线干扰及背景影响等情况。在未引入其它任何试剂的情况下,用硝酸既除去了大量的钼基体,又调整了溶液的酸度,用标准加入法测定钼酸铵中的杂质元素,无需加入高纯基准试剂进行基体匹配,有效降低了分析成本,又消除了由于忽略基准物质中杂质元素的含量给分析测定带来的误差。回收率在85%~112%之间。  相似文献   

2.
采用电感耦合等离子体原子发射光谱法(ICP-AES)测定了锌精矿中Ca,Mg,Cu,Pb,Fe,As,Cd,Sb八种元素的含量。其测定范围:0.1%≤w(Ca,Mg,As,Cu,Pb)≤5.0%,0.05%≤w(Cd)≤2.0%,1.0%≤w(Fe)≤10.0%,0.03%≤w(Sb)≤0.5%。经加标回收实验,各元素的加标回收率为95%~104%(n=3),相对标准偏差RSD小于0.27%~4.7%(n=11)。方法快速,准确、可靠,适用于锌精矿中Fe,Cu,Pb,Cd,Ca,Mg,As,Sb含量的同时测定。  相似文献   

3.
鲜魔芋及其种植土壤中矿物元素的ICP-AES法测定   总被引:2,自引:0,他引:2  
采用电感耦合等离子体原子发射光谱法(ICP-AES)测量了不同产区鲜魔芋球茎及其种植土壤中10种矿物元素的含量,并初步讨论其相关性;采用湿法消化处理样品并考察了不同元素测定的精密度、回收率;测定的相对标准偏差(RSD)均小于2%,回收率为95%-104%,结果可信度高。  相似文献   

4.
采用微波消解样品,运用电感耦合等离子体原子发射光谱法同时测定山药中K,Na,Ca,Mg,Zn,Fe,Cu,Mn,Se,Pb,Cd和Cr 12种元素。结果表明:方法简便、快速、准确;山药富含对人体有益的K,Ca,Fe,Mg,Zn,Mn,Se等矿物质元素,其肉质中重金属元素Pb,Cd,Cr含量均未超过国家食品卫生标准。  相似文献   

5.
采用硝酸-盐酸-氢氟酸高压封闭消解样品,电感耦合等离子体原子发射光谱法测定玄武岩中的8种微量元素。实验确定了方法的分解条件以及测定元素的检出限及干扰条件。用国家一级标准物质GBW07105(玄武岩)进行方法验证,检测结果与标准值基本吻合,符合地质矿产开发的要求。  相似文献   

6.
建立了测定金鸡胶囊中Ca、Mg、Mn、Fe、Cu、Zn和Sr 7种无机元素含量的分析方法.采用浓硝酸和高氯酸(8+2)的混合酸溶解样品,利用电感耦合等离子体原子发射光谱法(ICP-AES)对各种元素进行测定.金鸡胶囊含有丰富的对人体有益的无机元素,对待测样品的测定结果表明,Ca、Mg、Fe、Mn、Zn、Sr和Cu的含量...  相似文献   

7.
采用硝酸-盐酸-氢氟酸高压封闭消解样品,电感耦合等离子体原子发射光谱法测定锰结核和富钴结壳中的18种常、微量元素。实验过程中优化了仪器工作条件,选择了最佳的分析谱线。实验结果表明,方法的检出限低,精密度高,RSD小于2.0%(n=6),方法的线性相关系数r0.999 8,用来同时测定海洋沉积物中的多种金属元素,能满足检测需求。  相似文献   

8.
采用硝酸-盐酸-氢氟酸高压封闭消解样品,电感耦合等离子体光谱法测定锰结核GBW07296和富钴结壳GSMC-1标准物质中的18种常、微量元素。实验过程中确定了最佳工作条件,选择了最佳分析谱线。实验结果表明,该方法线性相关系数良好r>0.999 8,方法检出限低,精密度高,RSD小于2.0%(n=6),可同时测定锰结壳中的多种金属元素,方法完全能满足岩石、土壤、海洋沉积物中多个元素的检测需求。  相似文献   

9.
建立用电感耦合等离子体原子发射光谱法测定蒙乃尔(Monel)合金中Al、B、Co、Cr、Fe、Mn、Ti、Mg、Si、W、Sn、Ca、Mo、V 14种元素含量的分析方法。称取0.100 0 g样品,置于聚四氟乙烯烧杯中,先加入10 mL反王水,再加入1 mL磷酸和10 mL质量浓度为30%的酒石酸,进行电热板消解,在优化的仪器工作条件下对基体匹配的混合标准工作溶液进行测定。结果表明,以钇元素作为内标,14种元素在一定质量浓度范围内与光谱强度具有良好的线性关系,相关系数均不小于0.999 3,检出限为0.000 9%~0.0054%,测定结果的相对标准偏差为0.51%~4.28%(n=8),样品加标回收率为95.0%~110.0%。该方法适用于蒙乃尔合金中多种元素的测定。  相似文献   

10.
电感耦合等离子体发射光谱法测定铝合金中多元素   总被引:3,自引:0,他引:3  
提出了用电感耦合等离子体发射光谱法(ICP-AES)同时测定铝合金中铜,镁,锰,铁,硅,锌的分析方法。经试验选择各元素的最佳光谱线和工作条件。试验结果表明:用此方法测定铝合金标准样品中铜、镁、锰、铁、硅、锌,方法的准确度和精密度符合GB/T 6987.6—1986的技术要求。  相似文献   

11.
同时溶解和ICP-AES同时测定焊锡材料中的铅、锡和银   总被引:11,自引:0,他引:11  
铅锡银合金被广泛应用在焊料、耐磨合金等领域,对它们的检测目前主要有容量法[1]、原子光谱法[2,3]等。在该合金分析中,样品中铅锡银的溶解是分析中最重要的步骤,目前常用的样品溶解方法有:稀王水溶解铅锡法[2]、浓硫酸浓硝酸溶解锡银法[1]、稀硝酸溶解银法[4]。无论哪一种样品  相似文献   

12.
建立了内标法测定钢铁样品中化学成分的ICP-OES分析方法。利用铟元素作为内标物质,消除了铁基体元素对被测元素的干扰,减少了废气、废液的产生。钢铁样品中16种被测元素的检测范围在0.001%-20.00%之间,检出限为0.001-0.030μg/mL,回收率为97%-110%。该方法减少了高纯物质的使用。  相似文献   

13.
Hematite, goethite and siderite were found in geological samples using a simple, fast and low cost electroanalytical technique called voltammetry of immobilized microparticles (VMP). A carbon paste electrode was carefully rubbed onto the studied samples (an iron ore and ferrous oolites) to attach some microparticles to the surface of the electrode, and subsequently a potential scan was performed in two aqueous media to obtain the voltammogram which might be considered as the fingerprint of the sample deposited on the electrode. Each peak was related to an electrode process on the electrode whose peak potential indicates the type of iron compound. All the results were confirmed by commonly used analytical techniques to detect the presence of the different phases. All of this makes VMP an analytical tool very useful to save time and reduce analysis costs for geologist.  相似文献   

14.
15.
Simultaneous determination of several elements (U, Ta, Mn, Zr and W) with inductively coupled plasma atomic emission spectrometry (ICP-AES) in the presence of spectral interference was performed using chemometrics methods. True comparison between artificial neural network (ANN) and partial least squares regression (PLS) for simultaneous determination in different degrees of overlap was investigated. The emission spectra were recorded at uranium analytical line (263.553 nm) with a 0.06 nm spectral window by ICP-AES. Principal component analysis was applied to data and scores on 5 dominant principal components were subjected to ANN. A 5-5-5 (input, hidden and output neurons) network was used with linear transfer function after both hidden and output layers. The PI,S model was trained with five latent variables and 20 samples in calibration set. The relative errors of predictions (REP) in test set were 3.75% and 3.56% for ANN and PLS respectively.  相似文献   

16.
建立了离子体发射光谱仪测定钢中铈元素的方法。为消除共存元素对铈分析游线的光谱干扰,选择Ce413.380nm作为分析线,铈含量在0.005%-0.50%之间工作曲线线性良好。对于含量范围在0.005%-0.10%的铈元素,回收率为85.6%-12.5%,测定结果的相对标准偏差小于9.74%(n=8);对于含量范围在0.10%-0.50%的铈元素,回收率为99.5%-103.0%,测定结果的相对标准偏差小于3.52%(n=8)。该方法适宜钢中含量范围在O.005%-0.50%的铈元素的测定。  相似文献   

17.
微波消解-ICP-AES法测定茶叶中微量元素   总被引:10,自引:0,他引:10  
在微波消解器中,以HNO3-HClO4分解茶叶,然后用ICP-AES法测定样品溶液中的Ba,Ca,Cu,Fe,Mn,Pb,Zn,本法简便快速,污染少,回收率为90.2% ̄106.3%,相对标准偏差为1.7% ̄6.2%。  相似文献   

18.
Using dextran as both reductant and stabilizing agent, nanopetals(ZnO-Au NPs) were easily synthesized and possessed a petal-like morphology. The feature structure and size of such ZnO-Au NPs were adjustable by regulating the amount of chloroauric acid(HAuCl4). Moreover, the electrochemical property of the obtained NPs was evaluated by being immobilized on the glassy carbon electrode(GCE), which performed both high sensitivity and stability in dopamine(DA) determinations. Furthermore, the as-prepared ZnO-Au NPs could also detect DA and uric acid(UA) simultaneously in the mixture without interference, indicating good selectivity and showing promising potential in biosensing.  相似文献   

19.
准确测定润滑油中元素的含量对于监控润滑油使用性能和预测各种润滑机械故障具有重要的意义。介绍了高温灰化、溶剂稀释、湿法消解、乳化、压力融弹、微波消解6种前处理方法在ICP-AES测定润滑油元素含量中的应用。  相似文献   

20.
试样用HCl和HNO3分解,制成含2%~3%王水的样品溶液,在最佳条件下,用电感耦合等离子体原子发射光谱(ICP-OES)法测定样品中铁的含量。方法相对标准偏差RSD(n=12)为0.41%~1.6%,精密度和准确度均符合地质矿产实验室测试质量管理规范(区域地球化学普查样品化学成分分析)要求。适用于地球化学调查样品批量样品中铁的测定,方法已应用于实际工作中,结果满意。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号