首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new, fast and low-cost sample preparation for the determination of sulfonamide (SA) residues in chicken muscle by LC technique has been developed. The procedure involves single extraction of sample with acetonitrile, followed by a rapid clean-up and was called "dispersive solid-phase extraction" (dispersive SPE). Using dispersive SPE 25 mg of octadecyl sorbent was added to 1 ml of acetonitrile extract, mixed and centrifuged. The acetonitrile layer was evaporated and residue was dissolved in acetate buffer (pH 3.5). Analysed compounds were detected by fluorescence detector after pre-column derivatization with fluorescamine. The separation of analytes was performed with gradient elution with mobile phase methanol: 2% acetic acid and RP-LC analytical column. The whole procedure was evaluated for six sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfametoxypirydazine, sulfametoxazole and sulfadimetoxine) according to the European Commission Decision 2002/657/EC. Specificity, decision limit (CCalpha), detection capacity (CCbeta), trueness and precision were determined during validation process. The dispersive SPE with octadecyl sorbent was found suitable for sample preparation before sulfonamide determination in chicken muscle. As it was found the most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 90%. The used analytical conditions allow to successively separate all the tested sulfonamides with the limit of detection at the level of 1-5 microg/kg. The method is simple, rapid and more effective than conventional methods.  相似文献   

2.
A new, rapid, and efficient method for determining the fumagillin residues in honey was developed. The samples extracted were analyzed using LC/MS/MS. Chromatographic separation of fumagillin was performed in gradient mode on a C8 column (100 x 2.0 mm, 5 microm) at 40 degrees C. The mobile phase consisted of a mixture of 2 mM ammonium formate-0.01% formic acid solution and methanol; the flow rate was set to 0.2 mL/min. Under these conditions, it was possible to measure fumagillin and its isomers as a single peak. The sample preparation procedure used is based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, which is fast (approximately 30 min) and uses less organic solvent. The fumagillin was extracted with acetonitrile containing 0.1% formic acid, then purified using a solid-phase extraction method with an Oasis mixed-mode weak anion-exchange cartridge. The overall recovery of fumagillin ranged from 88.1 to 99.4%; the intra- and interassay CVs were <4.5% and <4.9%, respectively. The LOQ was 0.1 microg/kg. LC/MS/MS coupled with the QuEChERS method showed strong potential as a method for determining fumagillin residues in honey.  相似文献   

3.
A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1).  相似文献   

4.
The cyanotoxin β-methylamino-l-alanine (BMAA) has received renewed attention as an environmental risk factor for sporadic cases of amyotrophic lateral sclerosis (ALS) (Nunn et al., Brain Res 410:375–379, 1987). The aim of the present study was to develop and to validate an analytical procedure that allows the quantification of native BMAA and of its natural isomer, 2,4 diaminobutyric acid (DAB), in brain tissues. An analytical procedure was previously reported by our group for the determination of underivatized BMAA in environmental samples. It included a step of sample clean-up by solid phase extraction (SPE) with a mixed-mode sorbent and the analyses were performed by LC/MS-MS using hydrophilic interaction chromatography and multiple reactions monitoring scan mode. As brain tissues have a higher lipid content, the crucial step of sample clean-up had been optimized by evaluating the efficiency of the addition of a liquid/liquid extraction step prior to the SPE procedure or alternatively, of washing steps to the SPE extraction procedure. The efficiency was checked by visualizing the complexity of the resulting chromatograms in LC/MS and their performance by using spiked brain samples. The optimized analytical procedure, including a washing step with cyclohexane to the SPE with a recovery yield close to 100 %, was validated using the total error approach and allowed the quantification of BMAA in a concentration level ranging from 20 to 1,500 ng/g in brain samples. Finally, the feasibility of implementation of this procedure was verified in human brain samples from two patients who died of ALS.  相似文献   

5.
A rapid dispersive micro‐solid phase extraction (D‐μ‐SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM‐41 was used as sorbent in d ‐μ‐SPE of the azole compounds from biological fluids. Important D‐μ‐SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB‐C18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile–0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v /v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1–10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra‐ and inter‐day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3–114.8%. The MCM‐41‐D‐μ‐SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis.  相似文献   

6.
We previously reported a solid-phase extraction (SPE) method for determination of the neurotoxin domoic acid (DA) in both seawater and phytoplankton by liquid chromatography–tandem mass spectrometry (LC–MS/MS) with the purpose of sample desalting without DA pre-concentration. In the present study, we optimized the SPE procedure with seawater and phytoplankton samples directly acidified with aqueous formic acid without addition of organic solvents, which allowed sample desalting and also 20-fold pre-concentration of DA in seawater and phytoplankton samples. In order to reduce MS contamination, a diverter valve was installed between LC and MS to send the LC eluant to waste, except for the 6-min elution window bracketing the DA retention time, which was sent to the MS. Reduction of the MS turbo gas temperature also helped to maintain the long-term stability of MS signal. Recoveries exceeded 90% for the DA-negative seawater and the DA-positive cultured phytoplankton samples spiked with DA. The SPE method for DA extraction and sample clean-up in seawater was extended to mammalian fluids and tissues with modification in order to accommodate the fluid samples with limited available volumes and the tissue extracts in aqueous methanol. Recoveries of DA from DA-exposed laboratory mammalian samples (amniotic fluid, cerebrospinal fluid, plasma, placenta, and brain) were above 85%. Recoveries of DA from samples (urine, feces, intestinal contents, and gastric contents) collected from field stranded marine mammals showed large variations and were affected by the sample status. The optimized SPE–LC–MS method allows determination of DA at trace levels (low pg mL−1) in seawater with/without the presence of phytoplankton. The application of SPE clean-up to mammalian fluids and tissue extracts greatly reduced the LC column degradation and MS contamination, which allowed routine screening of marine mammalian samples for confirmation of DA exposure and determination of fluid and tissue DA concentrations in experimental laboratory animals.  相似文献   

7.
陈瑞清  俞道进  陈锋  黄一帆 《色谱》2010,28(10):997-1000
建立了测定鸡肉组织中癸氧喹酯(DEC)残留的高效液相色谱-串联质谱(HPLC-MS/MS)方法。样品经乙腈提取,正己烷脱脂,固相萃取(SPE)小柱净化;采用0.1%甲酸乙腈溶液-0.1%甲酸水溶液(78:22, v/v)为流动相,电喷雾正离子电离(ESI+)模式,多反应监测(MRM)检测模式,以内标法进行定量。结果表明: DEC在1~200 μg/L范围内呈良好的线性关系,相关系数(r2)大于0.99; 1、10、100 μg/kg 3个添加水平的回收率为78.2%~107.4%,日内、日间相对标准偏差(RSD)均小于15%,方法检出限为0.25 μg/kg,定量限为0.5 μg/kg。该方法简便、灵敏、精确,可用于鸡肉组织中DEC药物残留的确证检测。  相似文献   

8.
A novel solid-phase extraction (SPE) method was developed for extraction and cleanup of 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THC-COOH), the major metabolite of the active principle of marijuana, delta9-tetrahydrocannabinol, from urine samples. The protocol utilizes a polymeric mixed-mode cationic sorbent, Strata-X-C, which exhibits strong retention for the metabolite facilitating a more rigorous organic wash to eliminate matrix components/endogenous materials. Acetonitrile containing acetic acid was used as the elution solvent and is compatible with both LC-MS and GC-MS modes of analysis. The hydrophobic retention of Strata-X-C was demonstrated to be higher than a neutral polymeric sorbent, Strata-X, of the same backbone but devoid of the cation-exchange moiety (sulfonic acid), by LC studies employing homologous paraben probes. Simultaneously, the polar (non-ionic) interaction capability of Strata-X-C is also greater than that of Strata-X, as assessed through regioisomeric nitrophenol probes. These two features enable the metabolite to be retained strongly on Strata-X-C. Good linearity and precision was obtained for THC-COOH by GC-MS analysis of its trimethylsilyl derivative in the range 1-50 ng. A simplified room temperature instantaneous derivatization procedure was developed that is suitable for high-throughput screening of THC-COOH.  相似文献   

9.
The recent worldwide shortage of acetonitrile has prompted interest in alternative solvents for liquid chromatography/mass spectrometry (LC/MS). In this work, acetone was substituted for acetonitrile in the separation of a peptide mixture by reversed‐phase high‐performance liquid chromatography (RP‐HPLC) and in the positive electrospray ionization mass spectrometry (ESI‐MS) of individual peptides. On both C12 and C18 stationary phases, the substitution of acetone for acetonitrile as the organic component of the mobile phase did not alter the gradient elution order of a five‐peptide retention standard, but did increase peak width, shorten retention times, and increase peak tailing. Positive ESI mass spectra were obtained for angiotensin I, bradykinin, [Leu5]‐enkephalin, and somatostatin 14 dissolved in both acetonitrile/water/formic acid (25%/75%/0.1%) and acetone/water/formic acid (25%/75%/0.1%). Under optimized ESI‐MS conditions, the mass spectral response of [Leu5]‐enkephalin was increased two‐fold when the solvent contained acetone. The substitution of acetone for acetonitrile resulted in only slight changes in the responses of the remaining peptides. A higher capillary voltage was required for optimum response when acetone was used. Compared with acetonitrile/water/formic acid (50/50/0.1%), more interfering species below m/z = 140 were found in the ESI‐MS spectra of acetone/water/formic acid (50/50/0.1%). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
HR011303 is a novel and highly selective urate transporter 1 (URAT1) inhibitor. In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for quantification of HR011303 in beagle dog plasma. Plasma samples were pretreated with protein‐precipitation extraction by acetonitrile and added with a trifluoromethyl substituted analog of HR011303 as internal standard. The chromatographic separation was performed on a Shiseido C18 column (100 × 4.6 mm, i.d., 5 μm) by mobile phases consisting of 5 mm ammonium–formic acid (100:0.1) and acetonitrile–formic acid (100:0.1) solutions in gradient elution. The MS detection was conducted in electrospray positive ionization with multiple reactions monitoring at m/z 338 → 240 for HR011303 and m/z 328 → 230 for the internal standard using 25 eV argon gas collision induced dissociation. The established LC–MS/MS method showed good selectivity, sensitivity, precision and accuracy. The plasma pharmacokinetics of HR011303 in beagle dogs following both oral and intravenous administration were then successfully evaluated using this LC–MS/MS method.  相似文献   

11.
The simultaneous analysis of aflatoxins B1, G1, B2, G2 and ochratoxin A in beer was carried out by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). Mycotoxins were extracted, purified and concentrated from the beer sample in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric sorbent. Optimization of different parameters, such as type of SPE sorbent, type and amount of wash solvent and pH of the sample, was carried out. The mobile phase consisted of a gradient of methanol + water (0.1% HCOOH) and a reversed-phase C18 column was used for the separation. The mass spectrometer used an electrospray ionization source operated in the positive mode to detect aflatoxins and in the negative mode to detect ochratoxin. UPLC/MS/MS is a rapid and sensitive technique that allows the separation of the five toxins in only 3.2 min. The limit of detection is 1 pg.  相似文献   

12.
Microextraction by packed sorbent (MEPS) is a new format for solid-phase extraction (SPE) that has been miniaturized to work with sample volumes as small as 10 μL. The commercially available presentation of MEPS uses the same sorbents as conventional SPE columns and so is suitable for use with most existing methods by scaling the reagent and sample volumes. Unlike conventional SPE columns, the MEPS sorbent bed is integrated into a liquid handling syringe that allows for low void volume sample manipulations either manually or in combination with laboratory robotics. The key aspect of MEPS is that the solvent volume used for the elution of the analytes is of a suitable order of magnitude to be injected directly into GC or LC systems. This new technique is very promising because it is fast, simple and it requires very small volume of samples to produce comparable results to conventional SPE technique. Furthermore, this technique can be easily interfaced to LC/MS and GC/MS to provide a completely automated MEPS/LC/MS or MEPS/GC/MS system. This extraction technique (MEPS) could be of interest in clinical, forensic toxicology and environmental analysis areas. This review provides a short overview of recent applications of MEPS in clinical and pre-clinical studies for quantification of drugs and metabolites in blood, plasma and urine. The extraction of anti-cancer drugs, β-blockers drugs, local anaesthetics, neurotransmitters and antibiotics from biological samples using MEPS technique will be illustrated.  相似文献   

13.
A rapid and inexpensive multiresidue method for determining pesticides in fruits and vegetables is presented. Extraction of a 15 g sample with 15 mL acetonitrile was followed by buffering with magnesium sulfate, sodium chloride, sodium citrate dihydrate, and disodium citrate. Acidification with formic acid prior to dispersive cleanup with aminopropyl sorbent and magnesium sulfate was used to stabilize base-sensitive pesticides such as chlorothalonil. Extracts were concentrated to 2 g/mL. Analyses were conducted by GC/ion trap detector MS, GC-halogen-specific detector, and LC/triple quadrupole MS. Accuracy and repeatability for 166 compounds in tomato, potato, and cabbage were 70-120% and <20% CV in 85% of the compounds, respectively. Reproducibility over a 4 month period in multiple commodities and analytical conditions was 62-124%, with CVs better than 30% for 91% of the compounds. Supply cost/sample was reduced 66%, and time to extract a batch of 24 samples was reduced by half compared to the prior method that used a 50 g sample, 100 mL acetonitrile, multiple SPE columns, and additional instrumentation. Additional extraction studies were conducted in tomatoes, oranges, and green beans at 4 g/mL using a GC/MS triple quadrupole system with a programmable temperature vaporization inlet. Recoveries of 70-120% were achieved in 93% of all compounds in green beans, 95% in tomatoes, and 97% in oranges.  相似文献   

14.
A feasibility study was performed in order to study the possibilities in using molecularly imprinted polymers (MIPs) as sorbent material in solid-phase extraction (MISPE) for clean-up of clenbuterol from urine. A binding study of clenbuterol in several solvents was performed on a clenbuterol imprinted polymer as well as on a blank polymer. These binding experiments were used to find suitable loading, washing and elution solvents for the MISPE procedure. Extraction of clenbuterol from calf urine was performed by directly loading a 10-ml urine sample onto the MIP column. Thereafter the column was washed with 10 ml of acetonitrile containing 1% acetic acid, and finally clenbuterol was eluted with 6 ml of methanol containing 10% acetic acid. A recovery of 65% was obtained. This recovery could be increased up to 75% if a sample volume of 1 ml was used or up to 100% if urine was freeze-dried and the residue was dissolved in acetonitrile and spiked with clenbuterol prior to analysis. Chromatograms of the wash and eluate solutions show an efficient clean-up, which supports the potential of MISPE for clean-up of trace amounts of clenbuterol from calf urine.  相似文献   

15.
张秀尧  蔡欣欣  李毅 《分析化学》2012,40(8):1267-1273
建立了快速检测食品中蜡样芽孢杆菌呕吐毒素Cereulide的超高效液相色谱三重四极杆质谱联用分析方法.样品提取液经硅胶和Carb固相萃取柱净化后,以0.1%甲酸-0.2 mmol/L乙酸铵溶液和0.1%甲酸-乙腈溶液作为流动相进行梯度洗脱,在Acquity BEH 300 C18柱上实现分离,正离子ESI-MS/MS MRM方式检测,以13C6-Cereulide作为内标的稳定同位素稀释法进行定量分析.一次进样分析时间为7 min.米饭、添加33%玉米胚油的米饭和婴儿配方奶粉中平均加标回收率分别为85.7%~87.5%,85.3%~110%和94.2%~113%;相对标准偏差为4.6%~13%,5.9%~9.1%和3.4%~6.5%(n=6);定量限为10 ng/kg (S/N=10).方法灵敏、准确,适合于食品样品中Cereulide的测定,并已成功应用于食物中毒样品的检测.  相似文献   

16.
A rapid and high-throughput isotope dilution LC-MS/MS method with online sample pre-concentration and clean-up using anionic mixed-mode SPE was described for the determination of closantel and rafoxanide in edible bovine and ovine tissues. Tissue samples were extracted with acetonitrile and acetone mixture (60:40, v/v). Sample pre-concentration, clean-up and analysis were completed simultaneously with the online MAX SPE LC-MS/MS system. Closantel-(13) C(6) and rafoxanide-(13) C(6) were used as the internal standards to improve the precision of the method. The method was validated with edible ovine and bovine tissues (muscle, kidney and liver) fortified at three different levels. The accuracy and RSD were 86-106% and ≤14%, respectively. This high-throughput method was suitable for routine quantitative analysis of closantel and rafoxanide in food safety surveillance samples.  相似文献   

17.
Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.  相似文献   

18.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

19.
Xu J  Chen J  Shao L  Li X 《色谱》2011,29(5):450-453
建立了采用超高效液相色谱-串联质谱同时检测口腔卫生用品(牙膏及漱口水)中甲硝唑、替硝唑、奥硝唑、二甲硝咪唑和洛硝唑的方法。试样以0.1%(体积分数)的甲酸水溶液/乙腈(95:5, v/v)稀释,经高速离心后过滤膜净化,采用Cloversil C18色谱柱(100 mm×2.1 mm, 3.5 μm)分离,以0.1%甲酸水溶液和乙腈为流动相梯度洗脱,质谱检测,外标法定量。5种硝基咪唑类化合物在1.0~60.0 μg/L质量浓度范围内线性关系良好,相关系数r均不小于0.9992;在10.0、20.0和100 mg/kg加标水平的平均回收率为91.5%~108%,相对标准偏差为1.14%~5.22%;方法的定量限(LOQ,以信噪比为10计)为2.0 mg/kg。该方法可靠、稳定,可满足口腔卫生用品中硝基咪唑类药物含量检测与确证的需要。  相似文献   

20.
In this study, fourteen highly polar aminoglycoside (AGs) antibiotics were selected. Various stationary phases were tested, including Obelisc R, ZIC-HILIC, BEH amide and aminopropyl. The nature of the stationary phase, mobile phase (water or buffer solutions and acetonitrile), pH (percentage of formic acid), gradient conditions and injection solvents were systematically studied as relevant parameters for tuning retention selectivity and detectability of AGs in liquid chromatography electrospray tandem mass spectrometry (LC–(ESI)–MS/MS). Only the two zwitterionic phases (Obelisc R and ZIC-HILIC) achieved a proper chromatographic separation considering interferences due to the crosstalk effect in low resolution mass spectrometers. The water/acetonitrile mobile phase containing 1% formic acid used with Obelisc R provided more sensitivity than the highly concentrated buffered mobile phases required for ZIC-HILIC. A solid phase extraction (SPE) clean-up procedure with polymeric weak cation exchange (WCX) cartridges was optimized for honey, milk and liver samples. Different brands of cartridges and elution solvents were tested, and the Taurus WCX offered the best recovery rate with a buffer elution at pH 3. The final optimized method was validated in these matrices according to Decision 2002/657/EC. A monitoring campaign for sixty honey, milk and liver samples was carried out at the Food Authority Control in Geneva. The concentration of dihydrostreptomycin (DSTP) found in one ovine liver exceeded the established maximum residue levels (MRLs) within the European and Swiss legislations but it was compliant taking into account the validation data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号