首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
The rapidly growing, competitive biopharmaceutical market requires tight bioprocess monitoring. An integrated, automated platform for the routine online/at-line monitoring of key factors in the cell culture medium could greatly improve process monitoring. Mono- and disaccharides, as the main energy and carbon source, are one of these key factors. A CE-LIF method was developed for the analysis of several mono- and disaccharides, considering requirements and restrictions for analysis in an integrated, automated monitoring platform, such as the possibility for miniaturization to microchip electrophoresis. Analysis was performed after fluorescent derivatization with 8-aminopyrene-1,3,6-trisulfonic acid. The derivatisation reaction and the separation BGE were optimized using design of experiments. The developed method is applicable to the complex matrix of cell culture medium and proved transferable to microchip electrophoresis.  相似文献   

2.
Flow manipulation in sweeping microchip capillary electrophoresis (CE) is complicated by the free liquid communication between channels at the intersection, especially when the electroosmotic flows are mismatched in the main channel. Sweeping in traditional CE with cationic micelles is an effective way to concentrate anionic analytes. However, it is a challenge to transfer this method onto microchip CE because the dynamic coating process on capillary walls by cationic surfactants is interrupted when the sample solution free of surfactants is introduced into the microchip channels. This situation presents a difficulty in the sample loading, injection and dispensing processes. By adding surfactant at a concentration around the critical micelle concentration and by properly designing the voltage configuration, the flows in a microchip were effectively manipulated and this sweeping method was successfully moved to microchip CE using tetradecyltrimethylammonium bromide (TTAB). The sweeping effect of cationic surfactant in the sample solution was discussed theoretically and studied experimentally in traditional CE. The flows in a microchip were monitored with fluorescence imaging, and the injection and sweeping processes were studied by locating the detection point along the separation channel. A detection enhancement of up to 500-fold was achieved for 5-carboxyfluorescein.  相似文献   

3.
Fung YS  Lau KM 《Talanta》1998,45(4):641-656
A new capillary electrophoresis (CE) procedure was developed for simultaneous determination of both organic and inorganic anions in rain water using a background electrolyte (BGE) containing 5 mM molybdate, 0.15 mM CTAH, 0.01% PVA and 5 mM Tris buffer to adjust pH at 7.9. Under optimised conditions, good repeatability (RSD for sulphate in migration time=0.36% and peak area=4.2%), low detection limit (2 ppb for chloride) and satisfactory working range (50 ppb-20 ppm for hydrodynamic injection, 10 ppb-3 ppm for electrokinetic injection for chloride) were obtained. The reliability of the CE procedure developed was established by satisfactory recovery tests and good agreement of results obtained by both the CE and ion chromatography (IC) methods. The procedure developed had been successfully applied for field monitoring of rainwater showing good repeatability and capability of detecting trace anions at ppb levels beyond the IC working range. Thus, the new CE procedure developed provides a quick, sensitive, economic and reliable method to meet the need for the simultaneous determination of both organic and inorganic anions in the acid rain monitoring programme.  相似文献   

4.
The present study reports a novel method for the separation of the high-molecular-weight anionic polysaccharides, iota, kappa, and lambda carrageenans, in capillary electrophoresis (CE). Carrageenan samples are first derivatised with 9-aminopyrene-1,4,6-trisulfonic acid (APTS), separated in an ammonium acetate background electrolyte (BGE) and detected with laser-induced fluorescence (LIF). The effects of changes of instrumental parameters (temperature, injection mode, field strength) and the composition of the BGE (concentration and pH) are reported, and are explained in terms of the physical chemistry of the BGE and the biopolymers. Optimal separation conditions for kappa, iota, and lambda carrageenans, including an APTS internal standard, were found in a polyvinyl alcohol coated capillary with an ammonium acetate BGE of low concentration (25 mM) and moderate pH (8.0). This BGE gave the best reproducibility in tests on iota/kappa mixtures, with relative standard deviations (RSDs) in migration times and normalised peak areas (relative to the APTS internal standard) of less than 0.1% and 1%, respectively. Using this BGE at 50 degrees C and a voltage of 30 kV, all three carrageenan subtypes were separated in a run time of 3 min.  相似文献   

5.
Kok MG  de Jong GJ  Somsen GW 《Electrophoresis》2011,32(21):3016-3024
Analyte responses in CE‐ESI‐MS using negative ionization are frequently relatively low, thereby limiting sensitivity in metabolomics applications. In order to enhance the ionization efficiency of anionic metabolites, BGEs and sheath liquids (SLs) of various compositions were evaluated. Pressure‐induced infusion and CE‐MS experiments showed that addition of triethylamine (TEA) to the BGE and SL enhanced analyte intensities. A BGE consisting of 25 mM TEA (pH 11.7) and an SL of water–methanol (1:1, v/v) containing 5 mM TEA was selected, providing separation and detection of ten representative test metabolites with good reproducibility (migration time RSDs<1%) and linearity (R2>0.99). This BGE yielded lower limits of detection (0.7–9.1 μM) for most test compounds when compared with common CE‐MS methods using a BGE and SL containing ammonium acetate (NH4Ac) (25 and 5 mM, respectively). CE‐MS of human urine revealed an average amount of 231 molecular features in negative ionization mode when TEA was used in the BGE and SL, whereas 115 and 102 molecular features were found with an NH4Ac‐containing BGE and SL, employing a bare fused‐silica (BFS) and Polybrene‐dextran sulfate‐Polybrene (PB‐DS‐PB)‐coated capillary, respectively. With the CE‐MS method using TEA, about 170 molecular features were observed that were not detected with the NH4Ac‐based CE‐MS methods. For more than 82% of the molecular features that were detected with the TEA as well as the NH4Ac‐containg BGEs (i.e. common features), the peak intensities were higher using TEA with gain factors up to 7. Overall, the results demonstrate that BGEs and SLs containing TEA are quite favorable for the analysis of anionic metabolites in CE‐MS.  相似文献   

6.
Lee D  Shamsi SA 《Electrophoresis》2002,23(9):1314-1319
Enantiomeric separations of six anionic and two neutral racemates were achieved using a fully substituted heptakis(6-hydroxyethylamino-6-deoxy)-beta-cyclodextrin (beta-CD-EA) as a chiral selector. As beta-CD-EA provides a dynamic coating on the capillary wall, reverse-polarity capillary electrophoresis (CE) configuration is applied for separations of anionic and neutral chiral compounds. Chiral separations of various classes of anionic and neutral enantiomers were found to be highly dependent on pH because the degree of protonation of beta-CD-EA can alter the shape of the CD cavity by charge repulsion, altering complexation, aiding selectivity, and leading to better enantiomeric separation. In general, the chiral resolution of anionic enantiomers was enhanced at higher pH. This suggests that carboxylate or phosphate groups on the analyte may interact with the protonated amine groups of cationic CD. The successful enantioseparation was achieved in a pH range of 6.6-7.8 for all six anionic analytes, in the presence of 10 mM beta-CD-EA.  相似文献   

7.
Yao X  Wang J  Zhang L  Yang P  Chen G 《Talanta》2006,69(5):1285-1291
A microchip capillary electrophoresis (CE)–amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an amperometric detection cell containing a one-dimensionally adjustable disc detection electrode in a Plexiglas holder. It facilitates the precise three-dimensional alignment between the channel outlet and the detection electrode without a complicated three-dimensional manipulator. The performance of this unique system was demonstrated by separating four nitroaromatic pollutants (nitrobenzene, 2,4-dinitrotoluene, 2,4,6-trinitrotoluene, and p-nitrobenzene). Factors influencing their separation and detection processes were examined and optimised. The four analytes have been well-separated within 120 s in a 75 cm long separation channel at a separation voltage of +2000 V using an electrophoretic separation medium containing 15 mM borax and 15 mM sodium dodecyl sulfate (pH 9.2). Highly linear response is obtained for the four analytes over the range of 0–5 ppm with the detection limits ranging from 12 to 52 ppb. The present system demonstrated long-term stability and reproducibility with relative standard deviations of less than 5% for the peak current (n = 9). The new approach for the microchannel–electrode alignment should find a wide range of applications in other microfluidic analysis systems.  相似文献   

8.
Summary Amino acids in extracts of plant tissue were separated and detected by capillary zone electrophoresis (CZE) with indirect UV detection. Various aromatic carboxylates such as salicylate, benzoate, phthalate and trimellitate were investigated as background electrolytes (BGEs). A BGE of benzoate gave the best resolution and detector response. Amino acids were separated at a highly alkaline pH to charge amino acids negatively. Separation was achieved by the co-electroosmotic flow (Co-EOF) by the addition of the cationic surfactant myristyltrimethyl-ammonium bromide (MTAB) to the electrolyte. The condtions affecting the separation of amino acids, including electrolyte pH, concentrations of both benzoate and MTAB, were investigated and optimised. Separation of a mixture of 17 amino acids at pH 11.20 with indirect UV detection at 225 nm was achieved with a BGE of 10 mM benzoate containing 1.0 mM MTAB at pH of 11.20. Detection limits ranged between 10 and 50 μM. The proposed method was demonstrated by the determination of amino acids in extracts of Eucalypt leaves with direct injection of samples.  相似文献   

9.
An online preconcentration technique by dynamic pH junction was studied to improve the detection limit for anionic arsenic compounds by CE. The main target compound is roxarsone, or 3-nitro-4-hydroxyphenylarsonic acid, which is being used as an animal feed additive. The other inorganic and organoarsenic compounds studied are the possible biotransformation products of roxarsone. The arsenic species were separated by a dynamic pH junction in a fused-silica capillary using 15 mM phosphate buffer (pH 10.6) as the BGE and 15 mM acetic acid as the sample matrix. CE with UV detection was monitored at a wavelength of 192 nm. The influence of buffer pH and concentration on dynamic pH junction were investigated. The arsenic species focusing resulted in LOD improvement by a factor of 100-800. The combined use of C18 and anion exchange SPE and dynamic pH junction to CE analysis of chicken litter and soils helps to increase the detection sensitivity. Recoveries of spiked samples ranged between 70 and 72%.  相似文献   

10.
A background electrolyte (BGE) containing a 100 mM concentration of an alkylammonium cation with ethyl, propyl or butyl groups provides an excellent medium for separation of anions by capillary electrophoresis (CE). Two major effects were noted. Use of one of a series of alkylammonium cations in the BGE at a selected pH provides a simple and effective way to vary and control electroosmotic flow (EOF) over a broad range. It is believed that the alkylammonium cations are coated onto the capillary surface through a reversible dynamic equilibrium. Secondly, alkylammonium cations modify the electrophoretic migration of sample anions and the electroosmotic migration of neutral organic analytes by association interaction. This selective interaction results in improved anion separations and permits the simultaneous separation of neutral analytes. The degree of association interaction varies with the bulk and hydrophobicity of the alkylammonium cations. Incorporation of an aliphatic amine salt of moderate molecular weight in the running electrolyte provides a valuable new way to vary the migration times of sample anions and to optimize their resolution. The interactions between alkylammonium cations and sample anions or neutral organics appear to take place entirely within the liquid phase and do not require a polymeric or micellar pseudo phase.  相似文献   

11.
Fritz JS 《Electrophoresis》2003,24(10):1530-1536
Although nonionic compounds can be separated by micellar electrokinetic chromatography (MEKC), application of this technique is restricted by a somewhat limited elution range. Incorporation of organic solvents in the background electrolyte (BGE) greatly extends the scope of MEKC and provides a major variable in optimizing the separation of neutral analytes. This paper provides a systematic review of the principles and scope of the separation of neutral analytes by capillary electrophoresis (CE) in organic-aqueous solution. The methods surveyed include those that use tetraalkylammonium salts, dioctyl sulfosuccinate, lauryl poly(oxyethylene) sulfate. Polyaromatic hydrocarbon (PAH) compounds can be separated using sodium hexadecyl sulfate in 70% methanol (30% aqueous) to 100% methanol.  相似文献   

12.
Rapid quantitative microchip capillary electrophoresis (CE) for online monitoring of drinking water enabling inorganic ion separation in less than 15 s is presented. Comparing cationic and anionic standards at different concentrations the analysis of cationic species resulted in non-linear calibration curves. We interpret this effect as a variation in the volume of the injected sample plug caused by changes of the electroosmotic flow (EOF) due to the strong interaction of bivalent cations with the glass surface. This explanation is supported by the observation of severe peak tailing. Conducting microchip CE analysis in a glass microchannel, optimized conditions are received for the cationic species K+, Na+, Ca2+, Mg2+ using a background electrolyte consisting of 30 mmol/L histidine and 2-(N-morpholino)ethanesulfonic acid, containing 0.5 mmol/L potassium chloride to reduce surface interaction and 4 mmol/L tartaric acid as a complexing agent resulting in a pH-value of 5.8. Applying reversed EOF co-migration for the anionic species Cl-, SO42- and HCO3- optimized separation occurs in a background electrolyte consisting of 10 mmol/L 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) and 10 mmol/L HEPES sodium salt, containing 0.05 mmol/L CTAB (cetyltrimethylammonium bromide) resulting in a pH-value of 7.5. The detection limits are 20 micromol/L for the monovalent cationic and anionic species and 10 micromol/L for the divalent species. These values make the method very suitable for many applications including the analysis of abundant ions in tap water as demonstrated in this paper.  相似文献   

13.
A system of microchip capillary electrophoresis/electrospray ionization mass spectrometry (microchip-CE/ESI-MS) for rapid characterization of proteins has been developed. Capillary electrophoresis (CE) enables rapid analysis of a sample present in very small quantity, such as at femtomole levels, at high resolution. Faster CE/MS analysis is expected by downsizing the normal capillary to the microchip (microchip) capillary. Although rapidity and high resolution are advantages of CE separation, electroosmotic flow (EOF) instability caused by the interaction between proteins and the microchannel surface results in low reproducibility in the analysis of basic proteins under neutral pH conditions. By coating the microchannel surface with a basic polymer, polyE-323, basic proteins, which have pI values of over 7.5, could be separated and detected by microchip-CE/MS on quadrupole (Q) and time-of-flight (TOF) hybrid instruments. By increasing the cone and collision voltages during the analysis by microchip-CE/ESI-MS of a small protein, some product ions, which contain the sequence information, could also be obtained, i.e., 'top-down' analysis of the protein could be accomplished with this microchip-CE/MS system. To our knowledge, this is the first report of 'top-down' analysis of a protein by microchip-CE/MS. Since it requires a much shorter time and a smaller sample amount for analysis than the conventional liquid chromatography (LC)/ESI-MS method, microchip-CE/MS promises to be suitable for the high-throughput characterization of proteins.  相似文献   

14.
A new method for the CE separation of nine tricyclic antidepressants (TCAs), viz. amitriptyline, clomipramine, desipramine, doxepin, fluphenazine, imipramine, nortriptyline, promazine, and thioridazine, is described. The capillary was statically coated with a layer of poly(N,N-dimethylacrylamide) (PDMA) to suppress the EOF, and beta-CD was used as an additive in the BGE solution. The optimal resolution of nine TCAs was obtained by using a 1% v/v PDMA-coated capillary and a BGE solution of 50 mM sodium phosphate buffer (pH 3.0) containing 0.5 mM beta-CD. Efficiencies were typically >10(5 )plates/m. Complete separation of nine TCAs could be achieved in about 28 min; the two diastereomers of doxepin and the two enantiomers of thioridazine could also be separated. The RSD values of migration time and peak area of the TCAs were in the ranges 0.5-0.8 and 3.3-4.9% (n = 10), respectively. In combination with a suitable sample clean-up technique, such as hollow fiber-based liquid phase microextraction (HF-LPME), the polymer-coated capillary can be employed for the CE-UV analysis of TCAs in human plasma.  相似文献   

15.
The paper reports the results of a study carried out to evaluate the use of three 1‐alkyl‐3‐methylimidazolium‐based ionic liquids as non‐covalent coating agents for bare fused‐silica capillaries and additives of the electrolyte solutions (BGE) for CE of basic proteins in the co‐EOF separation mode. The three ionic liquids are differentiated from each other by the length of the alkyl group on the imidazolium cation, consisting of either an ethyl, butyl or octyl substituent, whereas tetrafluoroborate is the common anionic component of the ionic liquids. Coating the capillary with the ionic liquid resulted in improved peak shape and protein separation, while the EOF was maintained cathodic. This indicates that each ionic liquid is effective at masking the protein interaction sites on the inner surface of the capillary, also when its adsorption onto the capillary wall has not completely neutralized all the negative charges arising from the ionization of the silanol groups and the ionic liquid is not incorporated into the BGE employed for separation. Using the coated capillaries with BGE containing the ionic liquid employed for the coating, at concentration low enough to maintaining the EOF cathodic, both peak shape and protein separation varied to different extents, based on the particular ionic liquid used and its concentration. Fast and efficient separation of the model basic protein mixture in co‐electroosmotic CE is obtained with the 1‐butyl‐3‐methylimidazolium tetrafluoroborate coated capillary and 100 mM acetate buffer (pH 4.0) containing 4.4 mM 1‐butyl‐3‐methylimidazolium tetrafluoroborate as the BGE.  相似文献   

16.
A capillary electrophoresis (CE) procedure with contactless conductivity detection (C(4)D) has been developed for monitoring of neutral mono- and disaccharides in drinks and foodstuffs. The separation of a mixture of seven neutral saccharides (glucose, fructose, galactose, mannose, ribose, sucrose and lactose) employed a quartz capillary, 5 μm i.d., with an effective length of 18.3 cm, and 75 mM NaOH (pH 12.8) as the background electrolyte (BGE). The limit of detection (LOD) values obtained lied within a range from 0.4 μmol L(-1) for lactose to 0.9 μmol L(-1) for ribose, with a separation time shorter than 140 s. The procedure was successfully applied to determinations of saccharides in fruit juices, Coca-Cola, milk, red and white wines, yoghurts, honey and a foodstuff additive.  相似文献   

17.
In this work, a capillary electrophoretic method for the rapid quantitation of atorvastatin (AT) in a lipitor tablet was investigated and developed. Method development included studies of the effect of applied potential, buffer concentration, buffer pH, and hydrodynamic injection time on the electrophoretic separation. The method was validated with regard to linearity, precision, specificity, LOD, and LOQ. The optimum electrophoretic separation conditions were 25 mM sodium acetate buffer at pH 6, with a separation voltage of 25 kV using a 50 microm capillary of 33 cm total length. Sodium diclofenac was used as an internal standard. Analysis of AT in a commercial lipitor tablet by electrophoresis gave quite high efficiency, coupled with an analysis time of less than 1.2 min in comparison to LC. Once the separation was optimized on capillary, it was further miniaturized to a microchip platform, with linear imaging UV detection using microchip electrophoresis (MCE). Linear imaging UV detection allowed for real-time monitoring of the analyte movement on chip, so that the optimum separation time could be easily determined. This microchip electrophoretic method was compared to the CE method with regard to speed, efficiency, precision, and LOD. This work represents the most rapid and first reported analysis of AT using MCE.  相似文献   

18.
Measurement of binding constant by chip electrophoresis is a very promising technique for the high throughput screening of non-covalent interactions. Among the different electrophoretic methods available that yield the binding parameters, continuous frontal analysis is the most appropriate for a transposition from capillary electrophoresis (CE) to microchip electrophoresis. Implementation of this methodology in microchip was exemplified by the measurement of inclusion constants of 2-naphtalenesulfonate and neutral phenols (phenol, 4-chlorophenol and 4-nitrophenol) into beta-cyclodextrin by competitive assays. The issue of competitor choice is discussed in relation to its appropriateness for proper monitoring of the interaction.  相似文献   

19.
Diao P  Yuan H  Huo F  Chen L  Xiao D  Paau MC  Choi MM 《Talanta》2011,85(3):1279-1284
A simple and sensitive method has been developed for simultaneous analysis of three catecholamines: dopamine (DA), epinephrine (EP) and norepinephrine (NE) in urine by capillary electrophoresis (CE) coupled with in-column fiber-optic light-emitting diode-induced fluorescence detection (ICFO-LED-IFD). Fluorescein isothiocyanate was used as the fluorescence tagged reagent for derivatization of DA, EP and NE. The CE conditions for separation of these catecholamines were systematically investigated. It was found that catecholamines could be more effectively separated by adding β-cyclodextin (β-CD) and acetonitrile (ACN) to a background electrolyte (BGE) of sodium borate. The migration times are 10.61, 10.83 and 11.14 min for DA, EP and NE, respectively and the catecholamines are completely separated within 11.5 min under the optimal condition of a BGE containing 10% v/v ACN, 20 mM β-CD and 20 mM sodium borate (pH 9.5), and an applied voltage of 13 kV. The relative standard deviations of migration time and peak area for these catecholamines are less than 0.16 and 2.0%, respectively. The limit of quantifications (LOQs) for DA, EP and NE are 3.5, 1.0 and 3.1 nM whereas the limit of detections (LODs) for DA, EP and NE are 1.0, 0.3 and 0.9 nM, respectively. Our proposed CE method provides low LOQ and LOD values. This CE-ICFO-LED-IFD methodology has been successfully applied to analyze catecholamines in human urine samples with good accuracy and satisfactory recovery.  相似文献   

20.
In this paper, we describe the use of an integrated circuit (IC) microchip system as a detector in multiplex capillary electrophoresis (CE). This combination of multiplex capillary gel electrophoresis and the IC microchip technology represents a novel approach to DNA analysis on the microchip platform. Separation of DNA ladders using a multiplex CE microsystem of four capillaries was monitored simultaneously using the IC microchip system. The IC microchip-CE system has advantages such as low cost, rapid analysis, compactness, and multiplex capability, and has great potential as an alternative system to conventional capillary array gel electrophoresis systems based on charge-coupled device (CCD) detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏