共查询到6条相似文献,搜索用时 15 毫秒
1.
Sohee Cho Kyoung-Jin Shin Su-Jin Bae Ye-Lim Kwon Soong Deok Lee 《Electrophoresis》2020,41(18-19):1600-1605
DNA analysis of degraded samples and low-copy number DNA derived from skeletal remains, one of the most challenging forensic tasks, is common in disaster victim identification and genetic analysis of historical materials. Massively parallel sequencing (MPS) is a useful technique for STR analysis that enables the sequencing of smaller amplicons compared with conventional capillary electrophoresis (CE), which is valuable for the analysis of degraded DNA. In this study, 92 samples of human skeletal remains (70+ years postmortem) were tested using an in-house MPS-STR system designed for the analysis of degraded DNA. Multiple intrinsic factors of DNA from skeletal remains that affect STR typing were assessed. The recovery of STR alleles was influenced more by DNA input amount for amplification rather than DNA degradation, which may be attributed from the high quantity and quality of libraries prepared for MPS run. In addition, the higher success rate of STR typing was achieved using the MPS-STR system compared with a commercial CE-STR system by providing smaller sized fragments for amplification. The results can provide constructive information for the analysis of degraded sample, and this MPS-STR system will contribute in forensic application with regard to skeletal remain sample investigation. 相似文献
2.
Diana C. Vinueza-Espinosa Daniel R. Cuesta-Aguirre Assumpció Malgosa Cristina Santos 《Electrophoresis》2023,44(17-18):1423-1434
Poor nuclear DNA preservation from highly degraded skeletal remains is the most limiting factor for the genetic identification of individuals. Mitochondrial DNA (mtDNA) typing, and especially of the control region (CR), using next-generation sequencing (NGS), enables retrieval of valuable genetic information in forensic contexts where highly degraded human skeletal remains are the only source of genetic material. Currently, NGS commercial kits can type all mtDNA-CR in fewer steps than the conventional Sanger technique. The PowerSeq CRM Nested System kit (Promega Corporation) employs a nested multiplex-polymerase chain reaction (PCR) strategy to amplify and index all mtDNA-CR in a single reaction. Our study analyzes the success of mtDNA-CR typing of highly degraded human skeletons using the PowerSeq CRM Nested System kit. We used samples from 41 individuals from different time periods to test three protocols (M1, M2, and M3) based on modifications of PCR conditions. To analyze the detected variants, two bioinformatic procedures were compared: an in-house pipeline and the GeneMarker HTS software. The results showed that many samples were not analyzed when the standard protocol (M1) was used. In contrast, the M3 protocol, which includes 35 PCR cycles and longer denaturation and extension steps, successfully recovered the mtDNA-CR from highly degraded skeletal samples. Mixed base profiles and the percentage of damaged reads were both indicators of possible contamination and can provide better results if used together. Furthermore, our freely available in-house pipeline can provide variants concordant with the forensic software. 相似文献
3.
Jinding Liu Wenyan Li Jiaqi Wang Deqing Chen Zidong Liu Jie Shi Feng Cheng Zeqin Li Jianbo Ren Gengqian Zhang Keming Yun 《Electrophoresis》2019,40(14):1795-1804
Unbalanced and degraded mixtures (UDM) are frequently encountered during forensic DNA analysis. For example, forensic DNA units regularly encounter DNA mixture signal where the DNA signal from the alleged offender is masked or swamped by high quantities of DNA from the victim. Our previous data presented a new kind of DNA markers that composed of a deletion/insertion polymorphism (DIP) and a SNP and we termed this new kind of microhaplotypes DIP‐SNP (combination of DIP and SNP). Since such markers could be designed short enough for degraded DNA amplification, we hypothesized that DIP‐SNP markers are applicable for typing of UDM. In this study, we developed a new set of DIP‐SNPs with short amplicons which were complement to our prior developed system. The multiplex PCR and SNaPshot assay were established for 20 DIP‐SNPs in a Chinese Han population. The DIP‐SNPs were capable of detecting the minor contributor's allele in home‐made DNA mixture with sensitivities from 1:100 to 1:1000 with a total of 1 –10 ng input DNA. Moreover, this system successfully typed the degraded DNA whether it came from the single source or mixture samples. In Chinese population, the system showed an average informative value of 0.293 and combined informative value of 0.998363862. Our results demonstrated that DIP‐SNPs may serve as a valuable tool in detection of UDM in forensic medicine. 相似文献
4.
Agarose gel electrophoresis, a very routine procedure, requires molecular weight standards; these are usually manufactured from plasmid or viral DNA fragments, or more recently, from PCR products of defined sizes. We describe here the preparation of a molecular weight standard from a completely different DNA source - the uniquely organized genome of the beetle Tenebrio molitor. The standard can be used to accurately size DNAs between 150 and 4500 bp, a useful range of sizes for many agarose gel electrophoresis applications, including separation of PCR products and plasmid cloning targets. In addition, it is easy to prepare, inexpensive, and rivals the best of the commercial ladders. 相似文献
5.
In the present study, a comparison between a disposable electrochemical DNA biosensor and a Vibrio fischeri-based luminescent sensor for the detection of toxicants in water samples was made.In order to realize this study, a disposable electrochemical DNA biosensor has been reported. The DNA biosensor is assembled by immobilizing double stranded Calf Thymus DNA onto the surface of a disposable carbon screen-printed electrode. The oxidation signal of the guanine base, obtained by a square wave voltammetric scan, is used as analytical signal to detect the DNA damage; the presence of low molecular weight compounds with affinity for nucleic acids is measured by their effect on the guanine oxidation peak.Wastewater samples provided during First European Interlaboratory Exercise on water toxicity in the course of the project SWIFT-WFD were analyzed, and biosensor results were compared with a currently used toxicity test ToxAlert®100 based on the bioluminescence inhibition of Vibrio fischeri. This test have been used because is rapid, easy handling and cost effectively responses for the toxicity assessment in real water samples.The results showed a promising correlation between two tests used for the detection of toxic compounds in water samples. 相似文献
6.
《印度化学会志》2022,99(12):100799
A charge transfer hydrogen bonded complex was prepared and experimentally explored in an acetonitrile (ACN) medium between the proton acceptor (electron donor) 2, 3-Diamino-5-bromopyridine and the proton donor (electron acceptor) chloranilic acid. The stoichiometry of the charge transfer complex is 1:1. The Benesi-Hildebrand equation is used to calculate the molar absorptivity (εCT), association constant (KCT) and other spectroscopic physical characteristics. The solid compound was synthesized and studied using several spectroscopic methods. The presence of charge and proton transfers in the resultant complex was supported by 1H NMR, FT-IR and SEM-EDX investigations. The complex DNA binding ability was investigated using electron absorption spectroscopy, and the CT complex binding mechanism is intercalative. The intrinsic binding constant (Kb) value is 5.2 × 106M?1. The good binding affinity of the CT complex makes it potentially suitable for usage as a pharmaceutical in the future. Molecular docking calculations have been performed between CT complex and DNA (ID = 1BNA) to study the CT-DNA interaction theoretically. To corroborate the experimental findings, calculations based on DFT were carried out in the gas and PCM analysis where the existence of charge and hydrogen transfers. Finally, good agreement between experimental and theoretical computations was observed confirming that the basis set used is appropriate for the system under examination. 相似文献