首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Electron ionization (EI) gas chromatography/mass spectrometry (GC/MS) analysis of pentafluorobenzyl ester-trimethyl sllyl ether (PFB-TMS) derivatives of hydroxy-subshtuted fatty acids provides structural information comparable to that obtained in analysis of methyl ester-trimethyl silyl ether (Me-TMS) derivatives. Use of this derivative eliminates the need to prepare two separate derivatives, the PFB-TMS derivative for molecular weight determination by electron capture ionization (negative ions) analysis and the Me-TMS derivative for structural determination by EI GC/MS analysis. The relative abundance of fragment ions observed during EI GC/MS analysis of these derivatized unsaturated fatty acids indicates the location of the —OTMS substituents relative to double bond positions in those cases studied. The most abundant fragment ions are observed when the compound contains an unsaturation two carbon atoms removed from the —OTMS ether carbon (the β-OTMS position). The “saddle effect” observed in the GC/MS analyses of some derivatized monohy— droxy unsaturated fatty acids is suggested to be due to a thermally allowed pericyclic double bond rearrangement and indicates the presence of a conjugated diene one carbon atom removed from the —OTMS ether carbon (the α-OTMS position). The saddle effect is most prominent for fatty acids that contain additional unsaturation separated by a single methylene unit from the conjugated diene moiety.  相似文献   

2.
Summary The structure of glycolaldehyde and glyceraldehyde was determined using gas chromatography — mass spectrometry. Glycolaldehyde and glyceraldehyde, mixed with lactic acid, 2-furoic acid, furoin, xylose and ascorbic acid were separated on a capillary column coated with SE-52 as trimethylsilyl derivatives. The mass spectra show two dimeric forms for TMS-glycolaldehyde and one dimeric form for TMS-glyceraldehyde.  相似文献   

3.
The gas chromatographic and mass spectrometric properties of the monohydroxy acids 5-hydroxyeicosatetraenoic acid (5-HETE), 12-hydroxyeicosatetraenoic acid (12-HETE) and 15-hydroxyeicosatetraenoic acid (15-HETE) as their methyl ester trimethylsilyl, methyl ester allyldimethylsilyl and methyl ester tert.-butyldimethylsilyl ethers were investigated. The gas chromatographic properties of the trimethylsilyl and tert.-butyldimethylsilyl derivatives were found to be excellent while the allyldimethylsilyl derivative required a well deactivated column. The mass spectra of these silyl derivatives with the exception for 12-HETE did not exhibit particularly intense ions in the upper mass region. A quantitative analysis by selected-ion monitoring of the most intense ion in the upper mass region of respective mass spectrum demonstrated that a detection limit in the low picogram range could only be obtained for 12-HETE. Since the mass spectra indicated that the double bonds exerted a strong influence on the fragmentation pattern, the trimethylsilyl, allyldimethylsilyl and tert.-butyldimethylsilyl ethers of the methyl esters of the reduced analogues of the monohydroxy acids were prepared. The saturation of the double bonds completely altered the fragmentation patterns and very intense ions carrying a high percentage of the total ion abundance were found in all of the mass spectra. The developed technique was utilized for measurements of 5-HETE in lung tissue samples from patients with lung cancer.  相似文献   

4.
The fragmentation pathways for the dimethyl ester trimethylsilyl ether derivatives of some 3-hydroxydicarboxylic acids have been found by using B/E 2nd B2/E linked scans and isotope substitution techniques. Most of the fragments are due to ionization at silicon, which induces a fragmentation pattern that intimately reflects the structure of the compounds.  相似文献   

5.
The fragmentation pathways for the dimethyl ester trimethylsilyl enol ether derivatives of some 3-oxodicarboxylic acids have been found by using B/E and B2/E linked scans, collisional activated decomposition and isotope substitution techniques. The trimethylsilyloxy group strongly directs the decomposition processes, and induces a fragmentation pattern that intimately reflects the structure of the compounds.  相似文献   

6.
7.
This paper reports the extension of our multiresidue analysis (MA) procedure with 18 natural and synthetic steroids; permitting the identification and quantification, in total of 81 pollutants from one solution, by a single injection, as their trimethylsilyl (TMS)-oxime ether/ester derivatives, by gas chromatography-mass spectrometry (GC-MS), within 31 min. As a novelty to the field, basic researches, such as fragmentation pattern analysis and derivatization optimization studies were performed for androsterone, transdehydroandrosterone, transandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxy-progesterone-acetate, stigmasterol and β-sitosterol. Results confirmed that (i) the TMS oxime-ether derivatives of the keto steroids provide from 1.40 times (gestodene) up to 4.25 times (norethisterone) higher responses compared to their TMS-ether ones, and (ii) the distribution of syn/anti oximes is characteristic to the ketosteroid species examined. Based on our optimized mass fragmentation, solid phase extraction (SPE) and derivatization studies separations have been performed in the total ion current (TIC) mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Responses, obtained with derivatized standards proved to be linear (hydroxysteroids), or have been calculated from calibration curves (ketosteroids) in the range of 1.88-750ng/L levels. Limit of quantitation (LOQ) values varied between 1.88ng/L and 37.5ng/L concentrations. The most important practical messages of this work are the high androsterone (0.744-4.28μg/L), transandrosterone (0.138-4.00μg/L), coprostanol (2.11-302μg/L), cholesterol (0.308-41μg/L), stigmasterol (1.21-8.40μg/L) and β-sitosterol (1.12-11.0μg/L) contents of influent wastewaters. β-Estradiol (100ng/L) and estriol (54ng/L) were found in one influent sample, only. Reproducibilities, characterized with the relative standard deviation percentages (RSD%) of measurements, varied between 1.73 RSD% (β-estradiol) and 5.4 RSD% (stigmasterol), with an average of 4.82 RSD%.  相似文献   

8.
9.
哒嗪酮-类肟醚菊酯衍生物的合成研究   总被引:3,自引:0,他引:3  
刘天麟  周懿波 《有机化学》2000,20(5):758-763
从2-叔丁基-4,5-二氯哒嗪酮出发,以两种方法合成了中间体2-叔丁基-4-氯-5-(4-溴甲基苯氧)哒嗪酮(3)。3与肟反应合成了含哒嗪酮的苄基肟醚类化合物4a~4l。在相转移催化条件下,3与芳香醛肟反应得到单一的产物4,与芳香酮肟反应则生成4和5的混合物。文中讨论了反应物的空间效应、亲核试剂对该反应区域选择性的影响,并论证了产物的构型。  相似文献   

10.
A highly selective and sensitive method for the determination of 30 meta- and para-substituted alkylphenols from phenol (C0) to nonylphenol (C9) in biota is described. Dichloromethane extracts of spiked cod liver and muscle samples are cleaned up by gel permeation chromatography, derivatised with pentafluorobenzoyl chloride and analysed by gas chromatography-mass spectrometry with negative-ion chemical ionisation. Quantification is done with isotope dilution of five internal standards of different chain length. The detection limits were in the low microg/kg levels. There were encountered problems with background levels of 4-nonylphenol. 4-Nonylphenol isomers were found in a number of plastic and rubber products used in the laboratory.  相似文献   

11.
12.
A novel analytical procedure was developed for the rapid determination of disease biomarkers of maple syrup urine disease (MSUD),L-valine,L-leucine,L-isoleucine, andL-phenylalanine in dried blood spots. Amino acids extracted from neonatal dried blood spots were rapidly derivatized with bis-(trimethylsilyl)trifluoroacetamide (BSTFA) and then analyzed by gas chromatography-mass spectrometry (GC-MS). Derivatization conditions and the method validation were studied: optimal derivatization conditions were acetonitrile as reaction solvent, a temperature of 100°C, and a reaction time of 30 min. The proposed method provided a detection limit lower than 2.0 μM, recovery between 92% and 106%, and relative standard deviation less than 8.0%. The method was further tested in screening for neonatal MSUD by determination ofL-valine,L-leucineL-isoleucine, andL-phenylalanine in blood samples. The experimental results show that GC-MS following BSTFA derivatization is a rapid, simple, and sensitive method for the determination of amino acid disease biomarkers in blood samples, and is a potential tool for fast screening of MSUD. Figure  相似文献   

13.
Picolinyl ester derivatives of common fatty acids can be readily desorbed by fast atom bombardment (FAB) as positive ions and then collisionally activated. Collisionally activated spectra of the (M + H)+ ions of the derivatives reveal that structurally informative remote-charge-site fragmentations occur. The presence of substitutents such as double bond, branch points, cyclopropane rings, hydroxy groups, and epoxy rings interrupts the fragmentation process in such a way that the substituent can be identified and its location on the alkyl chain can be determined. This method is also applicable to the picolinyl esters of short-chain fatty acids and to the analysis of mixtures of fatty acid derivatives. The approach is advantageous becasue the epicolinyl ester derivatives are also amenable to gas chromatography/mass spectrometry (GC/MS). Therefore, the FAB-MS/MS approach developed here is complementary to GC/MS.  相似文献   

14.
An exhaustive GC-MS acquisition study was performed, for the simultaneous analysis of natural and synthetic steroids and cholic acids (in order to insert them into the last tierce of our multiresidue analysis system), such as androsterone, β-estradiol, transdehydroandro-sterone, transdehyroandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxyprogesterone-acetate, lithocholic acid, stigmasterol, cholic acid, chenodeoxycholic acid, β-sitosterol, ursodeoxycholic acid, 3-hydroxy-7-ketocholic acid and dehydrocholic acid, in total 26 compounds. As novelties to the field, for the trimethylsilyl (TMS) oxime ether/ester derivatives of steroids and cholic acids, at first, a tandem mass spectrometric (MS/MS), multiple reaction monitoring (MRM) type acquisition method has been developed in a single run; also for the first time, the three acquisition techniques, the full scan (FS), the selective ion monitoring (SIM), in our case the multiple ion monitoring (MIM) and the currently optimized MRM methods, have been compared; all three, in parallel, under strictly the same derivatization/instrumental conditions, both in matrix free solutions and municipal wastewater from two Hungarian wastewater treatment plants (WWTPs). Critical evaluation of the three acquisition protocols was collated on their analytical performances and validated under the same conditions. The data of six point calibration curves for FS, MIM and MRM methods, showed that both R2 (0.9995, 0.9858, 0.9975) and RSD (5.3, 5.8, 5.0), for two parallel derivatizations, each injected three times, proved to be independent of the acquisition processes. Whereas, for the method limit of quantification (LOQ) and the instrument limit of quantification (ILQ) values showed considerable differences. LOQ data, were decreasing in the FS, MIM, MRM line (expressed in ng/L), for all steroids and cholic acids. The same trend was determined in terms of the ILQ values. The practical utility of the optimized acquisition techniques was confirmed by the quantitation of the steroids and cholic acids contents of wastewater samples. Results confirmed the importance of the MRM acquisition method, even in comparison to the MIM one: with particular interest in selected cases: avoiding the extreme overestimation of the β-estradiol (156-1325%) and that of the ethinylestradiol (582-831%) concentrations in the wastewater samples.  相似文献   

15.
Summary This paper describes the fragmentation patterns and the GC-MS quantitation possibilities of the trimethylsilyl derivatives of thirty-one aromatic carboxylic acids, using ion trap detection (ITD). Sixteen aralkyl carboxylic acids, including those containing a saturated aliphatic side chain {phenylacetic, 2-phenylbutyric, phenylglycolic (mandelic acid), β-phenyllactic, 3-hydroxyphenylacetic, β-phenylpyruvic and 3-(4-hydroxyphenyl)-propionic acids} and those with an unsaturated aliphatic side chain {cinnamic, 2-hydroxycinnamic (o-coumaric), 4-methoxycinnamic, 3-hydroxycinnamic (m-coumaric), 4-hydroxycinnamic (p-coumaric), 4-hydroxy-3-methoxycinnamic (ferulic acid), 3,4-dihydroxycinnamic (caffeic), and 4-dihydroxy-3,5-dimethoxycinnamic (sinapic) acids}, as well as, the fifteen hydroxy(methoxy) benzoic acids {benzoic, 2-hydroxybenzoic (salicylic), 3-hydroxybenzoic, 4-hydroxybenzoic, 3,5-dimethoxybenzoic, 3,4-dimethoxybenzoic (veratric), 2,6-dihydroxybenzoic (γ-resorcylic), 3-methoxy-4-hydroxybenzoic (vanillic), 2,5-dihydroxybenzoic (gentisic), 2,4-dihydroxybenzoic (β-resorcylic), 3,4-dihydroxybenzoic (protocatechuic), 3,5-dihydroxybenzoic (α-resorcylic), 2,4,5-trimethoxybenzoic (asaronic), 3,5-dimethoxy-4-hydroxybenzoic (syringic) and 3,4,5-trihydroxybenzoic (gallic) acids}, provided distinct fragmentation characteristics that were very useful for their identification and simultaneously quantitation. Based on 1–20 ng amounts of acids, very informative ions of high mass with considerable intensities ([M+TMS]+, [M+1]+), , ([M−CH3]+) were obtained. In the case of the cinnamic acid derivatives, several odd electron fragments are formed by the loss of CO, HCHO and/or Si(CH3)4 molecules. In the case of benzoic acids the molecular ion proved to be abundant in three, the [M−CH3]+ ion in nine cases out of fifteen. The special MacLafferty rearrangement product ([C6H5Si(CH3)2]+) was obtained in different yields. In addition to the TIC values, at least three, and in most cases four, selective fragment ions could be utilized for quantitation. The reproducibility of the data in the concentration range of 1–20 ng acids proved to be between 1.2 and 13.0% (R.S.D.). Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997  相似文献   

16.
17.
A comparison of the elution properties of the major protein amino acids as their N(O)-acyl alkyl ester derivatives (O-n-propyl, -n-butyl, -isopentyl; N(O)-trifluoroacetyl, -heptafluorobutyryl) on open-tubular glass capillary columns coated with SE-30, OV-17, OV-210 and EGA is described. A single-column separation to the baseline of the protein amino acids as their N(O)-heptafluorobutyryl n-butyl ester derivatives in less than 35 min was obtained on the SE-30 column. OV-210 columns have properties complementary to those of SE-30 columns and can be used as an aid to compound identification from retention time data. Separations of the amino acids from beer and dialysate from uremic patients are used to illustrate the practical posibilities of the method.  相似文献   

18.
Summary Gas chromatographic — mass spectrometric study of the trifluoroacetyl-methyl esters of sulfur- and hydroxyl-containing amino acids such as methionine, cysteine, D-,-dimethylcysteine (D-penicillamine), serine, and threonine was carried out. Sterling hydrogen treated graphitized thermal carbon black (HTGTCB) was used as the adsorbent. The Henry's constants, and the initial differential adsorption heats of these amino acid derivatives were determined on the HTGTCB surface by gas chromatography.Introduction of two methyl groups into the -position of a cysteine molecule (,-dimethylcysteine) stimulates the intramolecular nonvalent interactions increasing the internal rotation barriers in the molecule. This is revealed in the sharply reduced retention of the ,-dimethylcysteine derivative on the HTGTCB surface (as compared to the cysteine derivative) and it also influences the fragmentation pathways under electron impact.Deceased.  相似文献   

19.
This work describes a GC-MS method for enantioselective separation of amino acids. The method is based on a derivatization reaction which employs a mixture of alkyl chloroformate-alcohol-pyridine, as reagents to obtain the N(O,S)-alkyl alkoxy carbonyl esters of amino acids. Various reaction parameters are investigated and optimized to achieve a reproducible derivatization procedure suitable for separation of amino acid enantiomers on Chirasil-L-Val chiral stationary phase. In particular, the following topics are investigated for 20 proteinogenic amino acids: (i) the proper reagent and reaction conditions to obtain the highest derivative yield; (ii) the amino acid reactivity and the MS properties of the obtained derivatives; (iii) the linearity and sensitivity of the analytical method; (iv) the retention behavior of the derivatives and their enantiomeric separation on the Chirasil-L-Val chiral stationary phase. By combining the resolution power of the Chirasil-L-Val column and the high selectivity of the SIM MS detection mode, the described procedure enables the enantiomeric separation and quantification of 16 enantiomeric pairs of amino acids. The procedure is simple and fast and reproducible. It displays a wide linearity range at ppb detection limits for quantitative determinations: these properties make this derivatization method a suitable candidate for amino acid GC-MS analysis on board of the spacecrafts in space exploration missions of solar system body environments.  相似文献   

20.
A simple, highly selective and sensitive method for the determination of 14 representative alkylphenols from phenol (C0) to nonylphenol (C9) in produced water is described. Solid-phase extraction (SPE) by anion-exchange sorbent is used to extract alkylphenols from produced water. The samples are then derivatised by pentafluorobenzoyl chloride and analysed on GC-MS (negative ion chemical ionisation, NCI). The derivatisation procedure has been validated by means of two-level factorial design (2(7-4)) experiments. Quantification is done with isotope dilution of five internal standards of different alkyl chain length. The detection limits were at low ng/l levels. A comparison with GC-MS analysis of non-derivatised alkylphenol samples revealed the advantage of derivatisation as described in the method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号