首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Among various mutation detection methods, constant denaturant capillary electrophoresis (CDCE) is one of the most common techniques for rapid identification of known or unknown mutations. In this report, a CDCE analysis method with homemade linear polyacrylamide (LPA) kit was developed on ABI 310 genetic analyzer, the effect and relationship of various denaturing factors in CDCE analysis were investigated and K-ras gene mutations of 31 coloerctal cancer patients were detected. Results indicate that, with the increase of chemical danaturant concentration, the optimum temperature was lowered, and when the concentration of urea (formamide) was higher than 7 M (40%), the homoduplex and heteroduplex of mutant samples were separated with difficulty. Detection results of K-ras gene in colorectal samples indicated that mutations were present in eight (26%) of 31 patients; most mutations were localized in codon 12, which is thought to be a critical step and plays an important role in human colorectal carcinogenesisas.  相似文献   

2.
3.
This paper describes a prototype instrument for high-throughput fraction collection with capillary array electrophoresis (CAE). The design of the system was based on a comprehensive collection approach, in which fractions from all capillaries were simultaneously collected in individual collection microwells in predefined time intervals. The location of the fractions in the microwells on the collection plate was determined by monitoring the individual zone velocities close to the end of each capillary. The collection microwell plate was fabricated from buffer-saturated agarose gel, which maintained permanent electrical contact with the separation capillaries during the collection process. Since the collection gel plate consisted of over 90% water, liquid evaporation from the collection wells was minimized. A 12-capillary array instrument was built with two-point detection using a side illumination scheme. The collection performance was demonstrated by reinjection of selected fractions of a double-stranded DNA (dsDNA) separation. The identity of collected DNA fragments was confirmed by PCR and sequencing.  相似文献   

4.
Cheng YQ  Yao B  Zhang HD  Fang J  Fang Q 《Electrophoresis》2010,31(19):3184-3191
A high-speed DNA fragment separation system was developed based on a short capillary and a slotted-vial array automated sample introduction system. The injection process of DNA sample in a short capillary was investigated systematically with three injection techniques including constant-field-strength, low-field-strength and translational spontaneous injections. Under the optimized conditions, picoliter-scale sample plugs (corresponding to ca. 20-μm plug length) were obtained, which ensure the high-speed and high-efficiency separation for DNA fragments with a short effective separation length. Other separation conditions including the sieving matrix concentration, separation field strength and effective separation length were also optimized. The present system was applied in the separation of ΦX174-Hae III digest DNA marker. With an effective separation length of 2.5 cm, the separation could be achieved in <100 s with plate heights ranging from 0.21 to 0.74 μm (corresponding to plate numbers from 4.86 × 10(6) to 1.36 × 10(6)/m). The repeatabilities for the migration time of the eleven fragments were between 0.4 and 1.1% RSD (n=8). By using the automated continuous injection method, the separation for four different DNA samples could be achieved within 250 s. The present system was further applied in the fast sizing of real DNA samples of PCR products.  相似文献   

5.
An automatic DNA fragment collector using capillary array gel electrophoresis has been developed. A sheath flow technique is used for not only detection but also collection of DNA fragments. In a sheath flow cell, the DNA fragments separated by 16 capillaries flow independently into corresponding sampling capillaries. The fraction collector consists of 16 sampling trays and each sampling tray is set beneath each end of the sampling capillaries to collect the flow-through DNA fragments. Certain DNA fragments are automatically sorted by controlling the movement of the sampling trays according to the signals from the system. The collector experimentally separated two mixtures of polymerase chain reaction (PCR) products: one prepared by using eight different sizes (base lengths from 161 to 562) of DNAs; and the other prepared by a differential display (DD) method with cDNA fragments. Collected DNA fragments are amplified by PCR and measured by electrophoresis. DNA fragments with base length differences of one (base lengths 363 and 364) were successfully separated. A separated DNA fragment from the DD sample was also successfully sequenced. In addition, differentially expressed DNA fragments were automatically sorted by comparative analysis, in which two similar cDNA fragment groups, labeled by two different fluorophores, respectively, were analyzed in the same gel-filled capillary. These results show that the automatic DNA fragment collector is useful for gene hunting in research fields such as drug discovery and DNA diagnostics.  相似文献   

6.
毛细管电泳柱端安培检测装置的研制   总被引:2,自引:1,他引:2  
研制了一种新型的毛细管电泳柱端型安培检测装置。以直径为6μm的碳纤维微电极为工作电极,在自组装的ACS-2000毛细管电泳仪上,考察了用不同内径毛细管分离时分离电压对背景噪声的影响。利用该装置同时测定了3种苯二酚的异构体。  相似文献   

7.
Hydrophilic polymers, hydroxypropylmethyl cellulose (HPMC) and polyethylene oxide (PEO), were employed both for the dynamic coating of the capillary surface and for the sieving matrix. Although PEO showed somewhat better coating efficiency, it was found that both HPMC and PEO as the dynamic coating polymers were not able to maintain the capillary surface coating during the separation of deoxyribonucleic acid (DNA) fragments. However, the continuous supply of PEO chain from the bulk made it possible to maintain the surface coating. An interesting result was obtained with DNA intercalating dye, ethidium bromide (EB). Better resolution was obtained with the use of EB probably due to the change of radius of gyration (Rg) of DNA.  相似文献   

8.
Gao L  Patterson EE  Shippy SA 《The Analyst》2006,131(2):222-228
A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.  相似文献   

9.
The DNA fragment detection focusing technique has further enhanced the sensitivity and information of DNA targets. The DNA fragment detection method was established by capillary electrophoresis with laser‐induced fluorescence detection and restriction endonuclease chromatographic fingerprinting (CE‐LIF‐REF) in our experiment. The silica capillary column was coated with short linear polyarclarylamide (SLPA) using nongel sieving technology. The excision product of various restricted enzymes of DNA fragments was obtained by REF with the molecular biology software Primer Premier 5. The PBR322/BsuRI DNA marker was used to establish the optimization method. The markers were focused electrophoretically and detected by CE‐LIF. The results demonstrate that the CE‐LIF‐REF with SLPA can improve separation, sensitivity and speed of analysis. This technique may be applied to analysis of the excision product of various restricted enzymes of prokaryotic plasmid (pIRES2), eukaryote plasmid (pcDNA3.1) and the PCR product of codon 248 region of gastric cancer tissue. The results suggest that this method could very sensitively separate the excision products of various restricted enzymes at a much better resolution than the traditional agarose electrophoresis. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
The paper is focused on the powerful prediction ability of the quantitative DNA sieving model in DNA separations by capillary electrophoresis, which was proposed by us previously. First, the DNA resolution can be predicted by the theory. The model predicts that the most difficult and easiest separation will be 184bp/192bp and 234bp/267bp respectively, which is consist with experimental results. Furthermore, the average relative differences of predicted and experimental resolution values (R(S)) for ssDNA 184b/192b or dsDNA 184bp/192bp were all smaller than 2.8% if the diffuse parameter D considered was 8×10(-5) cm(2)/s. Secondly, the optimum polymer concentrations for DNA separation were also calculated by the model, and the results show that polymer concentration should be as high as possible in DNA separation. Thirdly, the sieving ability of polymer will be predicted by the model. Polymer with smaller k, a polymer parameter calculated by the model, is prior to use as DNA sieving media.  相似文献   

11.
In order to study kin17 protein-DNA affinity, we have developed a fast and reproducible capillary electrophoresis (CE) analysis of a strongly basic protein: kin17 protein, using a nonpermanent coating based on poly(ethylene oxide) (PEO) to avoid adsorption of kin17. The coating procedure was optimized to provide a residual and stable electroosmotic flow (EOF = 5 x 10(-5) cm(2)/V x s), exhibiting RSD of 0.3% and excellent long-term stability. Good intraday and interday reproducibility of kin17 migration times (0.8 and 0.3% relative standard deviation (RSD), respectively) enabled us to consider that the recovery percentage obtained for kin17 protein was satisfactory (79%). The potential of this PEO-based coating procedure was evaluated for affinity CE method in order to study the affinity of kin17 protein for two single-stranded DNA (ssDNA) models: polydeoxyadenylic acid and polydeoxycytidilic acid (pdA and pdC). Binding constants (1.5 x 10(7) +/- 17% and 1.7 x 10(7) + 25%M(-1)) were evaluated assuming a 1:1 affinity between kin17 and pdA or pdC, respectively.  相似文献   

12.
Johns C  Macka M  Haddad PR 《Electrophoresis》2004,25(18-19):3145-3152
Indirect photometric detection in capillary electrophoresis (CE) has been predominantly performed in the UV region, in part due to a lack of suitable high-intensity and low-noise light sources in the visible spectral region. A new photometric detector based on light-emitting diodes (LEDs) as light sources and compatible with a commercially available CE instrument has been designed and constructed and its performance evaluated. The utility of this detector was successfully demonstrated by the indirect photometric detection of anions using a dye as probe and absorbance measured in the visible region. The detector exhibited very low baseline noise (around 0.03 mAU), stable output, and improved upper limit of detection linearity (502 mAU) compared with previously used LED detectors. The detector was tested for indirect detection of anions separated with an electrolyte containing 4 mM Orange G as the indirect detection probe, 10 mM histidine as an isoelectric buffer, and 0.05% hydroxypropylmethylcellulose to suppress the electroosmotic flow. Extremely low detection limits were obtained ranging from 0.16-0.36 microM (excluding chloride 0.56 microM), with separation efficiencies in the range of 154,000-274,000 theoretical plates.  相似文献   

13.
The analysis of microbial communities is of increasing importance in life sciences and bioengineering. Traditional techniques of investigations like culture or cloning methods suffer from many disadvantages. They are unable to give a complete qualitative and quantitative view of the total amount of microorganisms themselves, their interactions among each other and with their environment. Obviously, the determination of static or dynamic balances among microorganisms is of fast growing interest. The generation of species specific and fluorescently labeled 16S ribosomal DNA (rDNA) fragments by the terminal restriction fragment length polymorphism (T-RFLP) technique is a suitable tool to overcome the problems other methods have. For the separation of these fragments polyacrylamide gel sequencers are preferred as compared to capillary sequencers using linear polymers until now because of their higher electrophoretic resolution and therefore sizing accuracy. But modern capillary sequencers, especially multicapillary sequencers, offer an advanced grade of automation and an increased throughput necessary for the investigation of complex communities in long-time studies. Therefore, we adapted a T-RFLP technique to an automated high-throughput multicapillary electrophoresis device (ABI 3100 Genetic Analysis) with regard to a precise qualitative and quantitative characterization of microbial communities.  相似文献   

14.
D Liang  L Song  S Zhou  V S Zaitsev  B Chu 《Electrophoresis》1999,20(14):2856-2863
A new separation medium, poly(N-isopropylacrylamide)-g-poly(ethyleneoxide) (PNI-PAM-g-PEO) solution, used for double-stranded (ds) DNA separation by capillary electrophoresis (CE) is presented. This type of grafted copolymer has a good self-coating ability for quartz capillary tubing and a slightly temperature-dependent viscosity-adjustable property, making it easier to use. One bp resolution was achieved within 12.5 min by using 8% w/v PNIPAM-gPEO in 1 x TBE (Tris-borate-ethylenediaminetetraaceticacid) buffer with an effective column length of 10 cm and an applied electric field strength of 200 V/cm. The PNIPAM-g-PEO solutions had a high sieving ability for relatively small sized DNAs with the relative standard derivation for the first 10 runs being less than 0.9% by using the same polymer solution. With 8% w/v PNIPAM-g-PEO solution in a 1.5 cm column and 2400 V as the running voltage, phiX174/HaeIII digest could be clearly separated within 24 s.  相似文献   

15.
Wang J  Peng Z  Yang J  Wang X  Yang N 《Talanta》2008,75(3):817-823
Coupled capillary electrophoresis (CE) with end-column electrogenerated chemiluminescence (ECL) was adopted for the quantitative detection of clindamycin. Clindamycin enhanced ECL intensity of tris(2,2'-bypyridine)ruthenium(II) (Ru(bpy)(3)(2+)) as a coreactant. Under the optimized conditions, the ECL intensity was linear with the concentration of clindamycin over the range from 5.0 x 10(-7) to 1.0 x 10(-4)M with a detection limit of 1.4 x 10(-7)M. The proposed CE-ECL was successfully applied for the detection of clindamycin in pharmaceutical and clinic samples. The interaction of clindamycin with hemoglobin was also investigated. The binding constant of clindamycin with hemoglobin was estimated to be 3.6 x 10(3)M(-1).  相似文献   

16.
Liang D  Song L  Chen Z  Chu B 《Electrophoresis》2001,22(10):1997-2003
The effect of the separation medium in capillary electrophoresis consisting of a low-molecular-mass poly(N,N-dimethylacrylamide) (PDMA) solution on the DNA separation by adding a small amount of montmorillonite clay into the polymer matrix is presented. On the separation of the pBR322/HaeIII digest, both the resolution and the efficiency were increased by adding 2.5-5.0 x 10(-5) g/mL clay into the 5% w/v PDMA with a molecular mass of only 100 K. Moreover, there was no increase in the migration time of DNA fragments. Similar results were observed by using a C-terminated pGEM-3Zf(+) sequencing DNA sample in a sequencing buffer. Experimental data also showed that the addition of clay increased the viscosity of the polymer solution. We attribute this effect to the structural change of the polymer matrix caused by the exfoliated clay sheets, whereby the thin clay sheets function like a "dynamic cross-linking plate" for the PDMA chains and effectively increase the apparent molecular mass of PDMA.  相似文献   

17.
The possibility of using polymer mixtures with different chemical compositions as a DNA sequencing matrix by capillary electrophoresis (CE) has been exploited. Polyacrylamide (PAM, 2.5%, w/v) having a molecular mass of 2.2 x 10(6) has been mixed with poly(N,N-dimethylacrylamide) (PDMA) having molecular masses of 8000, 470000 and 2.1 x 10(6) at concentrations of 0.2, 0.5 and 1% (w/v). Unlike polymer mixtures of the same polymer with different molecular masses, the use of polymer mixtures with different chemical compositions encounters an incompatibility problem. It was found that the incompatibility increased with increasing PDMA molecular mass and PDMA concentration, which resulted in decreased efficiency in DNA sequencing. Also, the incompatibility had a more pronounced effect on the efficiency as the base number was increased. However, by choosing a low-molecular-mass PDMA of 8000 and a low concentration of 0.2% (w/v), the incompatibility of PAM and PDMA has been alleviated. At the same time, the advantage of using polymer mixtures revealed a higher efficiency for such a polymer mixture when compared with PAM. The mixture also endowed the separation medium with a dynamic coating ability. An efficiency of over 10 x 10(6) theoretical plates per meter has been achieved by using the bare capillaries without the additional chemical coating step.  相似文献   

18.
Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).  相似文献   

19.
The determination of the sequence selectivity of DNA-damaging agents is very important in elucidating the mechanism of action of anti-tumour drugs. The development of automated capillary DNA sequencers with fluorescent labelling has enabled a more precise method for DNA sequence specificity analysis. In this work we utilized the ABI 3730 capillary sequencer with laser-induced fluorescence to examine the sequence selectivity of cisplatin with purified DNA sequences. The use of this automated machine enabled a higher degree of precision of both position and intensity of cisplatin-DNA adducts than previously possible with manual and automated slab gel procedures. A problem with artefact bands was overcome by ethanol precipitation. It was found that cisplatin strongly formed adducts with telomeric DNA sequences.  相似文献   

20.
S Inagaki  Y Esaka  M Sako  M Goto 《Electrophoresis》2001,22(16):3408-3412
We have developed a method for the detection of DNA adducts by combining capillary electrophoresis (CE) with the specificity of amperometric detection. Guanine is the most easily damaged base of the four normal DNA bases and many adducts of guanine have been found in DNA. These guanine adducts are often electrochemically active, while the normal bases with the exception of guanine are not. Therefore, CE with amperometric detection will be a promising method to study DNA damage. The four normal deoxynucleosides and two damaged deoxnucleosides N2-ethyldeoxyguanosine (N2-ethyl-dG) and 8-hydroxydeoxyguanosine (8-OH-dG), were completely separated by micellar electrokinetic chromatography (MEKC). Deoxyguanosine and the two damaged deoxynucleosides were identified using amperometric detection. The sensitivity of our system was comparable to that of UV detection. Analysis of DNA hydrolysis products was also performed briefly using this method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号