1.
《Electroanalysis》2003,15(10):862-865
An integrated microfluidic device is used to derivatize, separate, and amperometrically detect amino acids and peptides in the presence of naphthalene‐2,3‐dicarboxyaldehyde (NDA). The integrated system offers a rapid (4 min) simultaneous measurements of 5 amino acids (Arg, Lys, Gly, Cys, PhenA) down to the 3.2 μM level in connection to a precolumn reaction chamber, an electrophoretic separation channel, and an end‐column thick‐film carbon‐electrode detector. The effect of the separation voltage, detection potential, reagent concentration, and other variables on the response is examined. Calibration and precision experiments indicate a linear and reproducible response. Applicability for the separation and detection of small peptides is demonstrated. Such on‐chip generation of electroactive products offers great promise for detecting other nonelectroactive analytes.  相似文献   

2.
选择了L-精氨酸和L-苯丙氨酸为分离样品体系,根据电泳实验提出样品基本参数,通过模拟计算考察了进样管道宽度和进样时间对进样方差的贡献;根据分离度与分离长度拟合曲线确定电泳芯片的有效分离长度;对化学发光柱后衍生管道施加的夹流电压进行了模拟优化,得出氨基酸体系分离分析的电泳芯片设计方案和操作参数为:进样管道宽度为分离管道宽度的1/2,简单进样充样时间应大于5 s,分离管道有效分离长度为30 mm,衍生夹流比1.0~1.6。根据模拟优化结果提出了电泳芯片设计方案,采用整体浇注法制作带有柱后衍生反应器的PDMS电泳芯片,按照模拟计算提出的电压操作参数实现了精氨酸和苯丙氨酸样品体系的准确进样、芯片电泳分离和柱后衍生化学发光检测。电泳过程模拟结果和实验结果相结合,考察了柱后衍生对样品谱带展宽的影响,简单进样过程样品泄露引起的谱峰拖尾现象,并讨论了夹流进样法对减小进样方差和抑制样品泄露的贡献。  相似文献   

3.
Free amino acids were quantitatively determined in cerebrospinal fluid (CSF) and plasma samples from patients with aseptic meningitis by a newly developed high performance liquid chromatographic (HPLC) method. The method of analysis was based on precolumn derivatization of orthophthaladehyde in the presence of 2-mercaptoethanol and detection was made at Eex = 340 nm and Eem = 450 nm. The method was sensitive and the limit for detection was less than 1 pmol for most of the amino acids. It took 45 min to separate 26 amino acids with highly reproducible results, giving a coefficient of variance for retention times and integrated areas less than 0.4% and 2%, respectively, after five replicate runs. The results accumulated in 10 patients were compared statistically with 11 age-matched healthy controls. Among the amino acids almost all the neurotransmitter candidates, such as aspartic acid, glutamic acid, glutamine, glycine, tyrosine, phenylalanine and gamma-aminobutyric acid (GABA), were significantly increased in the patients' CSF, whereas arginine and threonine were low. No change was observed in plasma amino acids in patients as compared to healthy controls. The higher levels of most of the neurotransmitters, especially GABA, aspartic acid and glutamic acid, could be used diagnostically in assessing the progression and remission in aseptic meningitis.  相似文献   

4.
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split–flow sampling interface integrated on the micro-chip. The microfluidic system measured 20×70×3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 μm I.D.×60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h−1 throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 μl and carrier flow-rate of 2.0 ml min−1. Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8–80 s, at separation lengths of 25–35 mm and electrical field strengths of 250–1500 V cm−1, with plate heights in the 0.7–3 μm range.  相似文献   

5.
This study develops a novel capillary electrophoresis (CE) microfluidic device featuring a conventional cross-form injection system and an expansion chamber located at the inlet of the separation channel. The combined injection system/expansion chamber arrangement is designed to deliver a high-quality sample band into the separation channel such that the detection performance of the device is enhanced. Numerical simulations are performed to investigate the electrokinetic transport processes in the microfluidic device and to establish the optimal configuration of the expansion chamber. The results indicate that an expansion chamber with an expansion ratio of 2.5 and an expansion length of 500 microm delivers a sample plug with the correct shape and orientation. With this particular configuration, the peak intensities of the sample are sharp and clearly distinguishable in the detection region of the separation channel. Therefore, this configuration is well suited for capillary electrophoresis applications which require a highly sensitive resolution of the sample plug. The novel CE microfluidic device developed in this study has an exciting potential for use in high-performance, high-throughput chemical analysis applications and in many other applications throughout the field of micro-total-analysis-systems.  相似文献   

6.
A high‐speed CE system for multiple samples was developed based on a short capillary and an automated sample introduction device consisting of a commercial multi‐well plate and an x‐y‐z translation stage. The spontaneous injection method was used to achieve picoliter‐scale sample injection from different sample wells. Under the optimized conditions, a 40 μm‐long sample plug (corresponding to 78‐pL plug volume) was obtained in a 50 μm id capillary, which ensured both the high separation speed and high separation efficiency. The performance of the system was demonstrated in the separation of FITC‐labeled amino acids with LIF detection. Five FITC‐labeled amino acids including arginine, phenylalanine, glycine, glutamic acid, and asparagine were separated within 15 s with an effective separation length of 1.5 cm. The separation efficiency ranged from 7.96 × 105/m to 1.12 × 106 /m (corresponding to 1.26–0.89 μm plate heights). The repeatability of the peak heights calibrated with an inner standard for different sample wells was 2.4 and 2.7% (n = 20) for arginine and phenylalanine, respectively. The present system was also applied in consecutive separations of 20 different samples of FITC‐labeled amino acids with a whole separation time of less than 6 min.  相似文献   

7.
A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.  相似文献   

8.
We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.  相似文献   

9.
Polystyrol microchannel-microheater chips were fabricated on the basis of imprinting and photolithography techniques. The solution (i.e., methanol) temperature in the vicinity of the microheater (width = 100 or 200 microm and length = 100 microm) integrated in the channel (width = 100 microm and depth = 20 microm) was evaluated on the basis of the temperature-dependent fluorescence lifetime of Rhodamine B as a function of a flow rate and the voltage applied to the heater. The study demonstrated that the fabricated chip acted certainly as a microheater. The chip was then applied to the thermal reaction between benzaldehyde and malononitrile in methanol. Under optimum conditions, benzilidenemalononitrile as the product of the reaction was obtained in a 96% yield with the reaction time of 84 s.  相似文献   

10.
The fabrication and performance of an electrophoretic separation chip with integrated optical waveguides for absorption detection is presented. The device was fabricated on a silicon substrate by standard microfabrication techniques with the use of two photolithographic mask steps. The waveguides on the device were connected to optical fibers, which enabled alignment free operation due to the absence of free-space optics. A 750 microm long U-shaped detection cell was used to facilitate longitudinal absorption detection. To minimize geometrically induced band broadening at the turn in the U-cell, tapering of the separation channel from a width of 120 down to 30 microm was employed. Electrical insulation was achieved by a 13 microm thermally grown silicon dioxide between the silicon substrate and the channels. The breakdown voltage during operation of the chip was measured to 10.6 kV. A separation of 3.2 microM rhodamine 110, 8 microM 2,7-dichlorofluorescein, 10 microM fluorescein and 18 microM 5-carboxyfluorescein was demonstrated on the device using the detection cell for absorption measurements at 488 nm.  相似文献   

11.
The growing importance of analyzing the human genome to detect hereditary and infectious diseases associated with specific DNA sequences has motivated us to develop automated devices to integrate sample preparation, real-time PCR, and microchannel electrophoresis (MCE). In this report, we present results from an optimized compact system capable of processing a raw sample of blood, extracting the DNA, and performing a multiplexed PCR reaction. Finally, an innovative electrophoretic separation was performed on the post-PCR products using a unique MCE system. The sample preparation system extracted and lysed white blood cells (WBC) from whole blood, producing DNA of sufficient quantity and quality for a polymerase chain reaction (PCR). Separation of multiple amplicons was achieved in a microfabricated channel 30 microm x 100 microm in cross section and 85 mm in length filled with a replaceable methyl cellulose matrix operated under denaturing conditions at 50 degrees C. By incorporating fluorescent-labeled primers in the PCR, the amplicons were identified by a two-color (multiplexed) fluorescence detection system. Two base-pair resolution of single-stranded DNA (PCR products) was achieved. We believe that this integrated system provides a unique solution for DNA analysis.  相似文献   

12.
Schiro PG  Kuyper CL  Chiu DT 《Electrophoresis》2007,28(14):2430-2438
This paper describes the use of two-beam line-confocal detection geometry for measuring the total mobility of individual molecules undergoing continuous-flow CE separation. High-sensitivity single-molecule confocal detection is usually performed with a diffraction limited focal spot (approximately 500 nm in diameter), which necessitates the use of nanometer-sized channels to ensure all molecules flow through the detection volume. To allow for the use of larger channels that are a few micrometers in width, we employed cylindrical optics to define a rectangular illumination area that is diffraction-limited (approximately 500 nm) in width, but a few micrometers in length to match the width of the microchannel. We present detailed studies that compare the performance of this line-confocal detection geometry with the more widely used point-confocal geometry. Overall, we found line-confocal detection to provide the highest combination of signal-to-background ratio and spatial detection efficiency when used with micrometer-sized channels. For example, in a 2 microm wide channel we achieved a 94% overall detection efficiency for single Alexa488 dye molecules when a 2 microm x 0.5 microm illumination area was used, but only 34% detection efficiency with a 0.5 microm-diameter detection spot. To carry out continuous-flow CE, we used two-beam fluorescent cross-correlation spectroscopy where the transit time of each molecule is determined by cross-correlating the fluorescence registered by two spatially offset line-confocal detectors. We successfully separated single molecules of FITC, FITC-tagged glutamate, and FITC-tagged glycine.  相似文献   

13.
This article presents a new, simple and rapid continuous separation method by combination of flow injection with capillary electrophoresis designed for the analysis of basic traditional Chinese medicines. The device was produced using commercial capillary and components readily available in analytical laboratory. In double-T configuration, the designed horizontal separation channel was 25 microm i.d. x 146 mm length (an effective separation length of 93 mm) quartz capillary, with two vertical elicitation arms produced from 0.5 mm i.d. pump tubing. The capillary was embedded in a 40 x 20 x 3 mm organic glass base. Using the double-T configuration, continuous introduction of a series of samples was achieved. More than 3.00 resolution for ephedrine and pseudo-ephedrine were obtained using 100 mm borate buffer (pH 9.80) within 8 min in 25 microm separation channel with an electrical field strength of 137 V/cm (UV detection at 215 nm). The linear calibration range was 50-1500 microg/mL (ephedrine, r = 0.9982; pseudo-ephedrine, r = 0.9990) for both analytes. The limits of detection were 2.65 micro g/mL for ephedrine and 2.92 microg/mL for pseudo-ephedrine. In this device, the contents of ephedrine and pseudo-ephedrine in five Chinese medicinal preparations were determined with RSDs (n = 5) in range 1.16-4.51% and recoveries in range 90.4-114.6%.  相似文献   

14.
The present report describes the preparation and characterization of large-bore particle-entrapped monolithic precolumns, which are suitable for incorporation into a two-dimensional liquid chromatography (2D-LC) system for proteome analysis. The fritless precolumns with different inner diameter (i.d.) (320 and 530 microm) were rapidly and successfully prepared by entrapping octadecylsilica (ODS) particles (5 microm, 300 A) prepacked into fused silica capillaries with a sol-gel network, which was formed by hydrolysis and polycondensation of methyltriethoxysilane (MTES). By optimizing the composition of the sol solution, the resulting large-bore monolithic precolumns of 5 mm length allow a flow rate of 20 microL/min loading buffer at a reasonable low back pressure of 25 bar or less and are capable of withstanding up to 300 bar inlet pressure. Scanning electron micrograms of the precolumns profile showed that the evolving sol-gel network joined particles to each other and onto the column wall, and no cracking or shrinkage of the column bed was observed even in 530 microm-i.d. capillary. The performance of the particle-entrapped monolithic precolumns used for preconcentration and desalting of proteolytic digest was evaluated by on-line coupling the large-bore precolumns with a capillary reversed-phase liquid chromatographic (RPLC) column followed by UV detection. The laboratory-made monolithic precolumns with 320 and 530 microm i.d. were characterized by using BSA tryptic digest or peptide standards as the analytes with respect to sample loading capacity, linearity, recovery and reproducibility, etc. The results indicate that the large-bore and short precolumns (5 mm x 320 microm i.d. or 5 mm x 530 microm i.d.) allow sample fast loading at a flow rate of 30 or 60 microL/min. The precolumns also have a mass loading capacity for BSA peptides of about 70 microg and for standard peptides of about 80 microg. Good linear calibration curves (R2 > 0.99) were obtained and the limits of detection (signal-to-noise ratio, S/N = 3) were improved by more than 60-fold and were between 0.53 and 1.32 ng/microL even with a UV absorbance detector. The total recovery was found to be approximately 90-100% for BSA digest and standard peptides. The day-to-day relative standard deviation (RSD) values for recoveries of BSA peptides on a single precolumn ranged from 4.66 to 7.56% and 2.68 to 3.05% for precolumn back pressure, while the column-to-column RSD values were 3.51-6.13% and 1.22-1.26% for recoveries of BSA peptides and precolumn back pressure, respectively. With good precolumn reproducibility, no significant degradation or decrease in precolumn performance was showed even after approximately 150 preconcentration/desorption cycles. The precolumns also proved to be resistant to salt buffer with high concentration and low-pH mobile phase. The large-bore particle-entrapped monolithic precolumns will be further used in a high-throughput 2D-LC array system coupled with tandem matrix assisted laser desorption/ionization-time of flight-time of flight-mass spectrometry (MALDI-TOF-TOF-MS) detection for proteome analysis.  相似文献   

15.
Experimental studies document that increased asymmetric dimethylarginine (ADMA) blood levels inhibit NOS significantly, reducing NO generation. ADMA measurement often needs sample cleanup by SPE prior to chromatography and precolumn derivatization that cannot be easily employed in a routine clinical setting. We set up a new reliable CE method to measure ADMA, symmetric dimethylarginine (SDMA), and arginine without sample extraction or precolumn derivatization in order to examine their concentrations in human plasma. Sample was concentrated prior to CE injection and analytes were monitored by UV detection. CE analysis was performed in an uncoated fused-silica capillary, 75 microm id and 60.2 cm length (50 cm to the detection window), injecting 1 s water plug (0.5 psi) followed by 10 s of the sample (0.5 psi). Separation was carried out in a 50 mmol/L Tris-phosphate run buffer at pH 2.30, 15 degrees C and 15 kV (75 microA) at normal polarity. Recovery of plasma ADMA was 101-104% and inter-day CV was less than 3%. Assay performance was evaluated measuring the levels of arginine and its dimethyl derivatives in 77 subjects. Passing-Bablok regression and Bland-Altman test for methods comparison suggest that the data obtained by our method and by a reference CE-LIF assay are similar.  相似文献   

16.
A microfluidic device with integrated waveguides and a long path length detection cell for UV/Vis absorbance detection is presented. The 750 microm U-cell detection geometry was evaluated in terms of its optical performance as well as its influence on efficiency for electrophoretic separations in the microdevice. Stray light was found to have a strong effect on both, the sensitivity of the detection and the available linear range. The long path length U-cell showed a 9 times higher sensitivity when compared to a conventional capillary electrophoresis (CE) system with a 75 microm inner diameter (ID) capillary, and a 22 times higher sensitivity than with a 50 microm ID capillary. The linear range was comparable to that achieved in a 75 microm ID capillary and more than twice as large as in a 50 microm ID capillary. The use of the 750 microm U-cell did not contribute significantly to band broadening; however, a clear quantification was made difficult by the convolution of several other band broadening sources.  相似文献   

17.
This work describes a microfluidic device integrated with multichamber polymerase chain reaction (PCR) and multichannel separation for parallel genetic analysis. The microdevice consists of three functional units: temperature control, multiple PCR (four chambers PCR), and multiple channel separation (four separation channels, each channel connected to a PCR chamber). Platinum (Pt)/titanium (Ti) microheater was used to ensure homogeneous temperature field, and Pt-chip sensor was used for temperature monitoring. The interface between chip-PCR and chip separation was simplified by connecting the PCR chamber with separation channel directly. After chip-PCR, PCR products were introduced into parallel separation channels for subsequent separation/detection by applying an electric field automatically. This microdevice was successfully applied for detection of pathogens including hepatitis B virus (HBV) and Mycobacterium tuberculosis (MTB), and genotyping of human leucocyte antigen (HLA)-B27 as well, demonstrating the feasibility of the integrated microdevice for parallel genetic analysis.  相似文献   

18.
An interface design is presented that facilitates automated sample introduction into an electrokinetic microchip, without perturbing the liquids within the microfluidic device. The design utilizes an interface flow channel with a volume flow resistance that is 0.54-4.1 x 10(6) times lower than the volume flow resistance of the electrokinetic fluid manifold used for mixing, reaction, separation, and analysis. A channel, 300 microm deep, 1 mm wide and 15-20 mm long, was etched in glass substrates to create the sample introduction channel (SIC) for a manifold of electrokinetic flow channels in the range of 10-13 microm depth and 36-275 microm width. Volume flow rates of up to 1 mL/min were pumped through the SIC without perturbing the solutions within the electrokinetic channel manifold. Calculations support this observation, suggesting a leakage flow to electroosmotic flow ratio of 0.1:1% in the electrokinetic channels, arising from 66-700 microL/min pressure-driven flow rates in the SIC. Peak heights for capillary electrophoresis separations in the electrokinetic flow manifold showed no dependence on whether the SIC pump was on or off. On-chip mixing, reaction and separation of anti-ovalbumin and ovalbumin could be performed with good quantitative results, independent of the SIC pump operation. Reproducibility of injection performance, estimated from peak height variations, ranged from 1.5-4%, depending upon the device design and the sample composition.  相似文献   

19.
A new fabrication procedure for integration of ultraviolet transparent pure-silica planar waveguides, fiber couplers and high-aspect ratio submicrometer channels is presented. Only a single photolithographic mask step is required. The channels are 80-90 microm deep and the width can be reduced to about 0.5 microm, corresponding to a height-to-width ratio of more than 150. The core of the waveguides consists of pure silicon dioxide, which is favorable over doped silica, due to the absence of absorption centers associated with the dopants. This furthermore improves the long-term stability of the waveguides, because of an increased radiation resistance of the glass. The propagation loss decreases from 1.0 dB/cm at 200 nm to 0.2 dB/cm at 800 nm, which, to our knowledge, is the lowest propagation loss reported for integrated planar waveguides in the ultraviolet wavelength region to date. The effective optical path length is 1.2 mm for an absorbance cell with a nominal length of 1.0 mm, indicating effective suppression of stray light. The limit of detection for paracetamol when present in the entire channel network was determined to 3 microg/mL. Finally, the applicability of the fabricated devices for capillary electrophoresis was evaluated by separation of caffein, paracetamol and ketoprofone using absorbance detection at 254 nm.  相似文献   

20.
A fluorescence-based integrated optics microfluidic device is presented, capable of detecting single DNA molecules in a high throughput and reproducible manner. The device integrates microfluidics for DNA stretching with two optical elements for single molecule detection (SMD): a plano-aspheric refractive lens for fluorescence excitation (illuminator) and a solid parabolic reflective mirror for fluorescence collection (collector). Although miniaturized in size, both optical components were produced and assembled onto the microfluidic device by readily manufacturable fabrication techniques. The optical resolution of the device is determined by the small and relatively low numerical aperture (NA) illuminator lens (0.10 effective NA, 4.0 mm diameter) that delivers excitation light to a diffraction limited 2.0 microm diameter spot at full width half maximum within the microfluidic channel. The collector (0.82 annular NA, 15 mm diameter) reflects the fluorescence over a large collection angle, representing 71% of a hemisphere, toward a single photon counting module in an infinity-corrected scheme. As a proof-of-principle experiment for this simple integrated device, individual intercalated lambda-phage DNA molecules (48.5 kb) were stretched in a mixed elongational-shear microflow, detected, and sized with a fluorescence signal to noise ratio of 9.9 +/-1.0. We have demonstrated that SMD does not require traditional high numerical aperture objective lenses and sub-micron positioning systems conventionally used in many applications. Rather, standard manufacturing processes can be combined in a novel way that promises greater accessibility and affordability for microfluidic-based single molecule applications.  相似文献   