首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In continuation of our efforts to discover novel nitric oxide-releasing non-steroidal anti-inflammatory drugs (NO-NSAIDs) as potentially "Safe NSAIDs," we report herein the design, synthesis and evaluation of 21 new NO-NSAIDs of commonly used NSAIDs such as aspirin, diclofenac, naproxen, flurbiprofen, ketoprofen, sulindac, ibuprofen and indomethacin. These prodrugs have NO-releasing disulfide linker attached to a parent NSAID via linkages such as an ester (compounds 9-16), a double ester (compounds 17-24), an imide (compounds 25-30) or an amide (compounds 31-33). Among these NO-NSAIDs, the ester-containing NO-aspirin (9), NO-diclofenac (10), NO-naproxen (11), and the imide-containing NO-aspirin (25), NO-flurbiprofen (27) and NO-ketoprofen (28) have shown promising oral absorption, anti-inflammatory activity and NO-releasing property, and also protected rats from NSAID-induced gastric damage. NO-aspirin compound 25, on further co-evaluation with aspirin at equimolar doses, exhibited comparable dose-dependent pharmacokinetics, inhibition of gastric mucosal prostaglandin E(2) (PGE(2)) synthesis and analgesic properties to those of aspirin, but retained its gastric-sparing properties even after doubling its oral dose. These promising NO-NSAIDs could therefore represent a new class of potentially "Safe NSAIDs" for the treatment of arthritic pain and inflammation.  相似文献   

2.
A high-sensitivity on-column preconcentration method, anion selective exhaustive injection (ASEI)-sweeping in micellar electrokinetic capillary chromatography (MEKC) has been developed for the analysis of non-steroidal anti-inflammatory drugs (NSAIDs): diclofenac sodium, ibuprofen, fenoprofen, naproxen, and ketoprofen in water samples. To achieve the best results of the ASEI-sweeping-MEKC method, conditions which affected preconcentration were examined, including the sodium dodecyl sulfate concentration, composition of the sample matrix, composition and injection length of the water plug, the concentration and the injection length of the high-conductivity buffer, and finally the sample injection time. Under the optimum stacking conditions the method was validated for the determination of the studied NSAIDs in river water samples with limits of detection ranging between 29 and 58 ng mL?1, and without any previous sample pretreatment.  相似文献   

3.
Three on-column preconcentration techniques were compared to analyse a group of nonsteroidal anti-inflammatory drugs (NSAIDs) using micellar electrokinetic capillary chromatography (MEKC) under pH-suppressed electroosmotic flow (EOF) in water samples. The analysed drugs were ibuprofen, fenoprofen, naproxen, ketoprofen, and diclofenac sodium. The micellar background electrolyte (BGE) solution was formed by 75 mM sodium dodecyl sulfate (SDS), 40% (v/v) acetonitrile, and 25 mM sodium phosphate at pH 2.5. When this BGE solution was used the applied voltage was reversed, -10 kV, and the drugs were separated within 20 min. The on-column preconcentration modes, characterised all of them for the sample matrix removal out of the capillary by itself under a reverse potential at the same time as the EOF was reduced, were stacking with reverse migrating micelles (SRMM), stacking with reverse migrating micelles-anion selective exhaustive injection (SRMM-ASEI), and field-enhanced sample injection with reverse migrating micelles (FESI-RMM). The sensitivity was improved up to 154-, 263-, and 63-fold, respectively when it was calculated through the peaks height. The optimised methods were validated with spiked mineral water by combining off-line solid-phase extraction (SPE) and the proposed on-line sample stacking strategies. The detection limits (LODs) of NSAIDs in mineral water were at ng/L levels.  相似文献   

4.
The electrooxidation of several non-steroidal anti-inflammatory drugs (indomethacin, mefenamic acid, and diclofenac) was investigated on nanoparticles of Ni–curcumin-complex-modified glassy carbon (n-GC) electrode in alkaline solution. Surfaces studies were performed by scanning electron micrographs and atomic force microscopy. The oxidation process and its kinetics were studied using cyclic voltammetry and chronoamperometry techniques and also pseudo-steady-state polarization measurements. Voltammetric studies indicated that, in the presence of drugs, the anodic peak current of low-valence nickel species increases, followed by a decrease in the corresponding cathodic current. This pattern indicates that drugs were oxidized on the redox mediator immobilized on the electrode surface via an electrocatalytic mechanism. A mechanism based on the electrochemical generation of Ni(III)-active sites and their subsequent consumption by drugs was proposed. The rate constants of the catalytic oxidation of drugs and the electron-transfer coefficient are reported. A sensitive, simple, and time-saving amperometric procedure was developed for the analysis of these drugs in bulk form and for the direct assay of tablets, using the n-GC electrode.  相似文献   

5.
Concern is growing over the contamination of the environment with pharmaceutical residues, among which non-steroidal anti-inflammatory drugs (NSAIDs) are one of the most abundant groups. Their widespread appearance in the aquatic environment is because of their high consumption and their incomplete removal during wastewater treatment. Because effective operation of wastewater-treatment plants is important for minimising the release of xenobiotic compounds, for example pharmaceutical products, into the aquatic environment, our study focuses on removal of commonly used NSAIDs (ibuprofen, naproxen, ketoprofen, diclofenac) and clofibric acid in a specially designed small-scale pilot wastewater treatment plant (PWWTP). This study shows that, except for diclofenac, steady-rate removal of NSAIDs over a two-year monitoring period has been achieved. Elimination of the compounds in the PWWTP was ≥87% for ibuprofen, naproxen and ketoprofen but only 49–59% for diclofenac. We also studied clofibric acid. Results after one month of operation revealed 30% elimination with no sign of adaptation by the biomass. Also described are degradation products of diclofenac, which we were able to identify because of the similarity of their mass spectra with those in the NIST library and by comparing the retention times of different compounds. Although the structures of these compounds were confirmed with a high probability (99%), we still need to compare the fragmentation of authentic compounds with degradation products formed under our experimental conditions. Degradation products of ibuprofen, naproxen, ketoprofen, and clofibric acid were found but these must be identified by use of high-resolution mass spectrometry and analysis of authentic compounds.  相似文献   

6.
In this study, a three-phase hollow fiber liquid-phase microextraction (HF-LPME) method combined with liquid chromatography–mass spectrometry was developed for direct determination of four non-steroidal anti-inflammatory drugs (ketoprofen, naproxen, diclofenac and ibuprofen) in sewage sludge. The drugs were extracted from non-spiked and spiked slurry samples with different amounts of sludge into an organic phase and then back-extracted into an aqueous phase held in the lumen of the hollow fiber. High enrichment factors ranging from 2761 to 3254 in pure water were achieved. In sludge samples, repeatability and inter-day precision were tested with relative standard deviation values between 10–18% and 7–15%, respectively. Average concentrations of 29 ± 9, 138 ± 2, 39 ± 5 and 122 ± 7 ng/g were determined in dried sludge from Källby sewage treatment plant (Sweden) for ketoprofen, naproxen, diclofenac and ibuprofen, respectively.  相似文献   

7.
梁彦明  宋航  付超  郑文丽 《分析化学》2003,31(10):1253-1255
用WHELK-O1手性色谱柱,在正相条件下测定了几种非甾体类解热镇痛药物萘普生、布洛芬、酮基布洛芬和苯氧布洛芬等中对映体的含量。结果表明:这种手性固定相色谱柱能够以正己烷和异丙醇为流动相,简便、快速、准确地测定非甾类药物中对映体的含量。  相似文献   

8.
An analytical method for the simultaneous determination of seven non-steroidal anti-inflammatory drugs (naproxen, ketoprofen, diclofenac, piroxicam, indomethacin, sulindac and diflunisal) and the anticonvulsant carbamazepine in river and wastewater is reported. The method involves pre-concentration and clean-up by solid-phase microextraction using polydimethylsiloxane/divinylbenzene fibers, followed by liquid chromatography with diode array detection analysis. Owing to the fact that river water samples did not contain interferences and no sensitivity changes due to sample matrix were observed, external calibration was implemented. Standardization was also applied in order to carry out the prediction step by preparing only two diluted standards that were subjected to the pre-concentration step and a set of standards prepared in solvent. For the analysis of wastewater samples, in contrast, it was necessary to implement standard addition calibration in combination with the multivariate curve resolution-alternating least squares (MCR-ALS) algorithm, which allowed us to overcome matrix effect and exploit the second order advantage. Recoveries ranging from 72% to 125% for all pharmaceuticals proved the accuracy of the proposed method in river water samples. On the other hand, wastewater sample recoveries ranged from 83% to 140% for all pharmaceuticals, showing an acceptable performance – considering this sample contains no modeled interferences.  相似文献   

9.
Non-steroidal anti-inflammatory drugs (NSAIDs) are pharmaceutical compounds with anti-inflammatory, analgesic, and antipyretic effects. Herein, a simple and rapid high-temperature liquid chromatography and superheated water chromatography method was developed and validated for the trace determination of NSAID residues of ketoprofen, naproxen, sodium diclofenac, and ibuprofen in water samples. The NSAIDs were separated in less than five minutes using buffered distilled water as the mobile phase and ODS Zirconia RP-C18 column as the stationary phase. Linearity was observed in the van’t Hoff plots of the tested drugs by employing a low acetonitrile percentage (20% ACN) in the mobile phase, without any significant changes in their retention mechanisms. However, nonlinear van’t Hoff plots were obtained for the superheated water chromatography data of the tested drugs because of significant changes in their retention factors, transition stage of the stationary phase, or the mobile phase properties. The limits of detection for ketoprofen, naproxen, sodium diclofenac, and ibuprofen were 14, 2, 4.2, and 32 µg L?1, respectively, and their limits of quantification were 44, 8, 12, and 98 µg L?1, respectively. The accuracy and precision parameters were determined for selected drugs, where the relative standard deviations were in the range of ± 0.2179–2.6741%. In addition, these conditions were employed for the removal of NSAIDs from the water samples using carbon nanotubes. The proposed system was applied for the separation and analyses of drugs in water and pharmaceutical samples, and acceptable recoveries of 90.48–98.15% for the water samples and 99.9–100.08% for the pharmaceutical samples were obtained.  相似文献   

10.
The permeabilities of several water-soluble drugs through excised hairless rat skin from their aqueous suspensions were investigated by using newly designed two-chamber diffusion cells. Disodium cromoglycate, diclofenac sodium, dopamine hydrochloride, isoproterenol hydrochloride, diltiazem hydrochloride and papaverine hydrochloride were selected as water-soluble drugs. Indomethacin, a lipophilic drug, and deuterium oxide (D2O) were used for comparison. The skin permeability coefficients of these water-soluble drugs were 100--1000 times lower than that of indomethacin. Since these drugs have high solubility in the donor solution (distilled water or lactate buffer), however, the skin permeation rates, which are in general proportional to the product of skin permeability coefficient and solubility of drugs in the drug-donor compartment, were comparable to or higher than that of indomethacin (1.7 micrograms/cm2/h): the skin permeation rate of dopamine hydrochloride (458 micrograms/cm2/h) was about 300 times higher than that of indomethacin. The water-soluble drugs with lower molecular weight and higher solubility in water showed higher skin permeation rates. These results suggest that some water-soluble drugs with low molecular weight and high solubility in water might be good candidates for transdermal drug delivery.  相似文献   

11.
A series of 4-(methylsulfonyl)aniline derivatives were synthesized in order to obtain new compounds as a potential anti-inflammatory agents with expected selectivity against COX-2 enzyme. In vivo acute anti-inflammatory activity of the final compounds 11-14 was evaluated in rat using an egg-white induced edema model of inflammation in a dose equivalent to 3 mg/Kg of diclofenac sodium. All tested compounds produced significant reduction of paw edema with respect to the effect of propylene glycol 50% v/v (control group). Moreover, the activity of compounds 11 and 14 was significantly higher than that of diclofenac sodium (at 3 mg/Kg) in the 120-300 minute time interval, while compound 12 expressed a comparable effect to that of diclofenac sodium in the 60-240 minute time interval time, and compound 13 showed a comparable effect to that of diclofenac sodium at all experimental times. The result of this study indicates that the incorporation of the 4-(methylsulfonyl)aniline pharamacophore into naproxen, indomethacine, diclofenac and mefanamic acid maintained their anti-inflammatory activity and may increase selectivity towards the COX-2 enzyme which will be confirmed in the future by assessing COX-2: COX-1 inhibitory ratios using a whole blood assay.  相似文献   

12.
An open tubular wall-coated capillary column containing histidine functional groups was prepared and employed for the capillary electrochromatographic separation of non-steroidal anti-inflammatory drugs. The anion exchange along with the hydrogen bonding and hydrophobic properties of the surface coating allowed the separation of analytes with very similar ionic mobility. Selectivity and resolution were studied by changing the pH over the range from 3.5 to 5.0 and the concentration of the buffer from 10 to 25 mM, as well as variation of the organic modifier, such as methanol, ethanol and 1-propanol over the range 7.5 to 20%. The optimum experimental conditions for the separation of a drug mixture, which consisted of indoprofen, ketoprofen, suprofen, naproxen, flurbiprofen, fenoprofen and ibuprofen were using a mixture of acetate buffer (20 mM, pH 5.0)-ethanol (1:5, v/v) as background electrolyte and an applied voltage of -20 kV with UV detection at 220 nm. The separation of these drugs could be achieved with an average plate number of 1.0 x 10(5) m(-1).  相似文献   

13.
The present work describes the development and validation of a method for the determination of five non-steroidal anti-inflammatory drugs (NSAIDs: clofibric acid, ibuprofen, naproxen, diclofenac and ketoprofen) in water samples. The fully automated method includes in situ aqueous derivatization followed by analyte enrichment by microextraction by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS). The MEPS variables, such as sample volume, elution solvent, elution volume, fill and injection speed and washing steps were optimized. It was possible to use the MEPS polymer (silica-C18) 250 times. Ibuprofen-d3 was used as internal standard. The reproducibility of the method, calculated as the relative standard deviation (RSD), was below 10% for all compounds. Detection limits in ultrapure water were between 3.0 and 110 ngL(-1) for ibuprofen and ketoprofen, respectively. External calibration was used in the determination of NSAIDs in several types of water samples, including tap, river, sea and influent and effluent wastewater. The results obtained revealed the presence of ibuprofen and naproxen in the influent wastewater sample and of naproxen in the effluent wastewater sample.  相似文献   

14.
A vesicle-forming chiral cationic surfactant (1R,2S)-(-)-N-dodecyl-N-methyl-ephedrinium bromide was evaluated as a pseudo-stationary phase in micellar electrokinetic chromatography (MEKC) for enantioseparation of eight non-steroidal anti-inflammatory drugs e.g., carprofen, flurbiprofen, fenoprofen, ibuprofen, indoprofen, ketoprofen, naproxen and suprofen by capillary electrophoresis. The effects of varying experimental conditions such as pH and concentration of surfactant in the running buffer on the enantiomer separation of the drugs are reported. A mixture of five of the above drugs was separated and each enantiomeric pair was also separated simultaneously in a single run by use of the surfactant. The strong electrostatic interactions between the analytes and the vesicles seemed to have a major role in the enantiomeric separation of the profens.  相似文献   

15.
Dispersive liquid–liquid microextraction (DLLME) has been proved to be a powerful tool for the rapid sample treatment of liquid samples providing at the same time high enrichment factors and extraction recoveries. A new, simple and easy to handle one step in-syringe set-up for DLLME is presented and critically discussed in this paper. The novel approach avoids the centrifugation step, typically off-line and time consuming, opening-up a new horizon on DLLME automation. The suitability of the proposal is evaluated by means of the determination of non-steroidal anti-inflammatory drugs in urine by liquid chromatography/ultraviolet detection. In the presented approach an ionic liquid is used as extractant. The target drugs can be determined in urine within the concentration range 0.02–10 μg mL−1, allowing their determination at therapeutic and toxic levels. Limits of detection were in the range from 8.3 ng mL−1 (indomethacin) to 32 ng mL−1 (ketoprofen). The repeatability of the proposed method expressed as RSD (n = 5) varied between 2.5% (for ketoprofen) and 8.6% (for indomethacin).  相似文献   

16.
The European Union has regulated the use of non-steroidal anti-inflammatory drugs (NSAIDs) in animal production and requires its member states to detect their residues in different matrices. In this work, a detailed MS and MS/MS study by ion-trap mass spectrometry of fourteen NSAIDs is described. Two multi-residue reversed-phase LC/ESI-MS/MS methods were developed, one for the determination of salicylic acid, naproxen, carprofen, flurbiprofen, ibuprofen, niflumic acid and meclofenamic acid in the negative ion mode, and the other for the determination of ketoprofen, suxibutazone, diclofenac, mefenamic acid, tolfenamic acid, phenylbutazone and its metabolite oxyphenbutazone in the positive ion mode. It was thus possible to confirm up to 14 different NSAID residues in serum and plasma samples of farmed animals, after chromatographic separation by a linear gradient. These substances were chosen as representative of different chemical subclasses of NSAIDs. The two methods were also validated in-house at three contamination levels, evaluating specificity and calculating mean recoveries, repeatability and within-laboratory reproducibility. The MS/MS product ion spectra were successfully used for the qualitative identification of all the drugs tested. All the NSAIDs, apart from salicylic acid, were recovered in high amounts, ranging between 71.6% and 100.9%.  相似文献   

17.
The European Union regulated the use of non-steroidal anti-inflammatory drugs (NSAIDs) in animal production and set the official analytical controls to detect their residues in plasma, serum, and milk within the frame of national monitoring programs in each member state. In this work, a multi-residue reversed-phase high-performance liquid chromatography with diode array detector (DAD) method is described for the simultaneous determination of 13 NSAIDs in serum and plasma of farm animals. Chromatographic separation by a C12 stationary phase column with a linear gradient is able to resolve all the compounds considered: salicylic acid, ketoprofen, flurbiprofen, phenylbutazone and its metabolite (oxyphenbutazone), carprofen, ibuprofen, naproxen, niflumic acid, suxibutazone, diclofenac, mefenamic acid, and tolfenamic acid. These compounds are chosen as the most representative of the different NSAID chemical sub-classes. The DAD analysis allows the confirmation of all drugs on the basis of their own UV-vis spectrum, according to the requirements of the European Council Decision 2002/657/EC. Moreover, the method is in-house validated, evaluating mean recoveries, specificity, repeatability, and within-laboratory reproducibility as the performance parameters required by the Decision. The results of this study indicate the method is specific and repeatable, with the mean percentage recoveries of the drugs ranging between 72.5% and 104.5%. Only salicylic acid has poor recovery, with results ranging between 36.3% and 54.9%.  相似文献   

18.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

19.
In this paper, an electromembrane extraction (EME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of six widely used non-steroidal anti-inflammatory drugs (NSAIDs): salicylic acid (SAC), ketorolac (KTR), ketoprofen (KTP), naproxen (NAX), diclofenac (DIC) and ibuprofen (IBU). The drugs were extracted from basic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 1-octanol impregnated in the walls of a S6/2 Accurel® polypropylene hollow fiber, and into a basic aqueous acceptor solution resent inside the lumen of the hollow fiber with a potential difference of 10 V applied over the SLM. Extractions that were carried out in 10 min using a potential of 10 V from pH 12 NaOH aqueous solutions shown concentration enrichments factors of 28-49 in a pH 12 NaOH aqueous acceptor solution. The proposed method was successfully applied to urban wastewaters. Excellent selectivity was demonstrated as no interfering peaks were detected. The procedure allows very low detection and quantitation limits of 0.0009-9.0 and 0.003-11.1 μg L−1, respectively.  相似文献   

20.
An analytical method based on LC and UV detection has been developed for the determination of anti-inflammatory compounds and estrogens in water samples. The drugs investigated were diclofenac, ketoprofen, ibuprofen, naproxen, clofibric acid, estriol, 17beta-estradiol, estrone and ethynylestradiol. The detection limits were in the range of 6-74 microg/L and 0.041 -0.16 mg/L for acidic pharmaceuticals and estrogens, respectively, using narrow-bore C18 analytical column. Analyte enrichment from water samples was achieved by SPE procedure using polymeric Strata-X cartridges. Average recoveries obtained from 2.5 L of surface water sample were in the range of 77-98%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号