首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A robust analytical method, using reversed-phase high-performance liquid chromatography with gradient elution and photodiode-array detection, was used to measure six purines and beta-NAD+ in acid-soluble extracts of samples taken from six different regions of human term placenta. Resolution of the analyte peaks in chromatographic profiles of the extracts, and the use of optimized integration, allowed simultaneous quantitation of all seven analytes from a single chromatogram. Peak purity was confirmed via on-line analysis of peak spectra, utilizing the purity parameter treatment of spectral data. Major placental purines were adenosine, inosine, hypoxanthine and adenine. Except for adenine, concentrations of the purines varied by two-fold or more between different regions of each placenta, but concentration ratios, i.e., adenosine/inosine and inosine/hypoxanthine, were similar. The findings indicate that the pathway of ATP breakdown to hypoxanthine in ischemic human term placenta is via adenosine, and that regional differences in placental concentrations of adenosine and its metabolites may result from regional differences in degree of ischemia.  相似文献   

2.
This paper describes a simple and sensitive high-performance liquid chromatographic method for measuring adenosine, inosine and hypoxanthine in cell suspensions. The method involves direct injection of the filtered sample on a microbore C18 reversed-phase column with UV detection at 259 nm. The mobile phase consisted of 125 mM potassium dihydrogenphosphate, 1.0 mM tetrabutylammonium hydrogen-sulfate, 1.5% acetonitrile and 20 mM triethylamine, pH 6.5. The minimum detectable amounts (signal-to-noise ratio of 3:1) were 2.0 pmol of adenosine, 2.5 pmol inosine and 3.5 pmol of hypoxanthine. The limits of quantitation were 2.9 +/- 0.2 pmol for adenosine, 4.2 +/- 0.3 pmol for inosine and 4.9 +/- 0.4 pmol for hypoxanthine. This method was used to quantitate adenosine release by dispersed rat renal outer medullary cells (tubules) under conditions of normoxia and hypoxia.  相似文献   

3.
《Analytical letters》2012,45(14):2267-2274
A simple and sensitive liquid chromatography assay following solid phase extraction was developed for simultaneous determination of adenosine and inosine in sheep plasma. The system consisted of a Symmetry C18 column, a mobile phase composed of acetonitrile, 100 mM sodium dihydrogen phosphate and water, and ultraviolet detection at 254 nm. The method showed good sensitivity (limits of detection for adenosine and inosine were 30 and 50 ng/ml, respectively, in the plasma samples), repeatability, and linearity. The developed method was applied to sheep plasma samples from a study examining the cardio active potential of the combination of adenosine and inosine.  相似文献   

4.
Abstract

Ion suppression-reversed phase high performance liquid chromatography, using 0.6 M ammonium dihydrogen phosphate as eluent, produces base-line separations of deoxyribonucleotides. The effects of pH and ionic strength are described. This isochratic system is simple, reproducible and fast, requiring less than 30 min for a complete separation, and is suitable for in vitro studies.  相似文献   

5.
A simple binary solvent method has been developed for the simultaneous determination of creatine (Cr), phosphocreatine (PCr), ATP, ADP, AMP, GTP, GDP, IMP, NAD, inosine, adenosine, hypoxanthine and xanthine. This allows separation of the most important nucleotides present in myocardial biopsies as, for example, in studies using 31P NMR spectroscopy. In NMR spectra ATP and PCr are the only visible high-energy phosphates, therefore the status of other nucleotides and bases cannot be determined. The nucleotides, AMP degradation products, PCr and Cr in pig and rat heart muscle were resolved with 35 mM K2HPO4, 6 mM tetrabutylammonium hydrogensulfate buffer, pH 6.0, and a binary acetonitrile gradient on medium-bore, 250 mm or 125 mm x 3.9-4.6 mm I.D. steel octadecyl-bonded (C18) columns at a flow-rate of 1.5 or 1.0 ml/min. This method, optimized for use with older high-performance liquid chromatography pumps (100 microliters displacement heads), resolves the major porcine and rat myocardial nucleotides and degradation products within 22 min. The amounts found in normoxic porcine muscle are: Cr 9.21 +/- 0.75; hypoxanthine 1.40 +/- 0.14; PCr 7.20 +/- 1.2; IMP 1.34 +/- 0.13; beta NAD 1.82 +/- 0.23; AMP 0.10 +/- 0.04; GDP 0.05 +/- 0.02; ADP 1.23 +/- 0.09; GTP 0.19 +/- 0.01; ATP 4.45 +/- 0.32 mumol/g wet weight. The method, incorporating adenosine tetraphosphate as an internal standard, allows the documentation of changes in both the high-energy phosphates and their degradation products in a single analysis of myocardial samples as small as 200 micrograms (wet weight).  相似文献   

6.
Goyal RN  Gupta VK  Chatterjee S 《Talanta》2008,76(3):662-668
Voltammetric determination of adenosine and inosine has been carried out at single-wall carbon nanotubes (SWNTs) modified pyrolytic graphite electrode (PGE) at pH 7.2 using Osteryoung square wave voltammetry (OSWV). The modified electrode exhibits remarkable electrocatalytic properties towards adenosine and inosine oxidation with a peak potential of approximately 1229 mV and 1348 mV, respectively. Linear calibration curves are obtained over the concentration range 0.5 microM to 1.0 mM in adenosine and 10 microM to 1.0 mM in inosine with sensitivity of 1.0 microA microM(-1) and 1.9 microA microM(-1) for adenosine and inosine respectively. The limit of detection for adenosine and inosine was found to be 0.51x10(-7) M and 2.04x10(-7) M, respectively. The proposed method was also used to estimate these compounds in human blood plasma and urine samples and the method was validated using HPLC.  相似文献   

7.
A high-performance liquid chromatographic method is described for the separation and quantitation of several purine compounds, including hypoxanthine. The isocratic separation of a standard mixture of nine compounds is achieved within 20 min on a reversed-phase Nucleosil 100-5C18 column, with a mobile phase of KH2PO4 (300 mM, pH 4.0)-methanol-acetonitrile-tetrahydrofuran (97.9:1:1:0.1, v/v). Uric acid, guanine, hypoxanthine, uridine, xanthine, allopurinol, inosine, guanosine and 7-methylxanthine were almost completely baseline-separated, with detection limits in the range 0.5-1.2 pmol per injection. The influence of the concentrations of buffer and tetrahydrofuran on the quality of separation are described. The within-day and the day-to-day precision were satisfactory (e.g. coefficients of variation of less than 1.5 and ca. 6.0%, respectively, for peak heights). The recovery of [3H]hypoxanthine added to samples was 86 +/- 1%. Hypoxanthine was quantified in human plasma samples obtained at various times during coronary artery bypass grafting. The hypoxanthine levels measured immediately after release of the aortic cross-clamp were significantly higher than those determined under control conditions (18.8 +/- 7.0 and 3.4 +/- 1.0 microM, respectively).  相似文献   

8.
A capillary zone electrophoretic method was developed for the separation of the high-ceiling loop diuretic Torasemide and three of its metabolites (M1, M3 and M5) using an experimental design approach. Two different experimental designs were employed to optimize the developed method: (i) a fractional factorial design examining six factors at two levels (2(6-2)) and (ii) a central composite design examining two factors at two levels (2(2)+2x2+p). The factors studied were: pH, buffer concentration, proportion of boric acid in the mixed boric acid:potassium dihydrogen phosphate background electrolyte, temperature, applied voltage and percentage of organic modifier. Resolution between peaks was established as response. Separation of the four studied compounds was achieved in less than 8 min, using an electrolyte of 20 mM boric acid:potassium dihydrogen phosphate (75:25 v/v) with 15% MeOH adjusted to pH 9.7 with KOH, at a potential of 28 kV. Detection wavelength and temperature were 206 nm and 35 degrees C, respectively.  相似文献   

9.
A simple and rapid capillary electrophoretic method was developed for the simultaneous determination of micro-molar adenosine, hypoxanthine and inosine in enzyme assays without using radioactive labeled substrates. Prior to electrophoretic separation, addition of acetonitrile and sodium chloride to the assay solution and brief centrifugation are recommended for the purpose of sample cleanup and sample stacking. Under the optimal condition, the good separation with high efficiency was achieved in 6 min. Using deoxyadenylate as an internal standard, the linear range of the method was 5-200 microM, and the concentration limits of detection of adenosine, hypoxanthine and inosine were 2.2, 3.6 and 1.4 microM, respectively. Application of the proposed method was demonstrated by the activity assay of 5'-nucleotidase from Hep G2 cells.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method for determining glycarbylamide (GB) in chicken tissue was developed. GB was extracted with acetonitrile, followed by solid-phase extraction cleanup using a Bond Elut cartridge column with neutral alumina. After the extract had been evaporated to dryness, the residue was dissolved in 1.0 mL 0.1 N sodium hydroxide. Then 1.0 mL 0.1 M potassium dihydrogen phosphate solution was added to it. HPLC separation was done on a 250 x 4.6 mm id TSK-GEL ODS 80 column with 0.05M potassium dihydrogen phosphate as the mobile phase. Ultraviolet detection was done at a wavelength of 260 nm. The calibration curve of standard GB solutions was linear between 0.16 and 3 micrograms/mL (correlation coefficient, r = 0.999). The recovery of GB from chicken muscle spiked at 0.8 microgram/g was 88.6 +/- 2.3% (mean +/- standard deviation, n = 5), and the lower limit of determination was 0.05 microgram/g in chicken muscle.  相似文献   

11.
A simple method is described for simultaneous determination of six main nucleosides and bases including adenine, uracil, adenosine, guanosine, uridine and inosine in Cordyceps by capillary electrophoresis (CE). Chemometric optimization based on central composite design was employed to find the optimum resolution. The optimum factor space was defined by three parameters: buffer concentration, pH and concentration of acetonitrile as organic modifier. Resolution (Rs) was employed to evaluate the response function. A running buffer composed of 500 mM boric acid, adjusted pH to 8.6 with sodium hydroxide and 12.2% acetonitrile as modifier was found to be the most appropriate for the separation. The contents of the six components were determined by using adenosine monophosphate as an internal standard. Furthermore, hierarchical clustering analysis based on characteristics of 32 peaks in CE profiles from the tested 12 samples showed that natural and cultured Cordyceps were in different clusters. Adenosine and inosine were extracted as markers for discrimination of natural Cordyceps. The result of clustering based on the two peaks characteristics was in excellent agreement with that based on 32 peaks'. Thus, adenosine and inosine could be used as markers for quality control of natural and cultured Cordyceps.  相似文献   

12.
Yang FQ  Li S  Li P  Wang YT 《Electrophoresis》2007,28(11):1681-1688
A CEC method is described for the simultaneous determination of 11 nucleosides and nucleobases including cytosine, uracil, uridine, hypoxanthine, 2'-deoxyuridine, inosine, guanosine, thymidine, adenine, adenosine, and cordycepin in Cordyceps using 5-chlorocytosine arabinoside as internal standard (IS). Chemometric optimization based on central composite design was employed to find the optimum conditions. The factors for optimization were defined as three parameters: voltage, pH, and concentration of ACN as organic modifier. The resolution (R(s)) between inosine and guanosine, as well as the entire run time were employed to evaluate the response function. A running buffer composed of 4 mM ammonium acetate and 2 mM triethylamine (TEA) adjusted to pH 5.3 using acetic acid, and containing 3% ACN as modifier, with gradient voltage (0-4 min: 20 kV, 4-12 min: linear gradient from 20 to 30 kV; 12-16 min: 30 kV) were found to be the optimum conditions for the separation. Separation of the 11 investigated compounds and 5-chlorocytosine arabinoside was achieved within 16 min. The contents of the 11 compounds in natural and cultured Cordyceps sinensis, and cultured Cordyceps militaris were also compared. The result showed that CEC is an efficient method for analysis of nucleosides and nucleobases in Cordyceps, which is helpful to control the quality of this valued traditional Chinese medicine.  相似文献   

13.
陈沛金  颜治  涂小珂  肖锋  梁宏 《色谱》2015,33(7):771-776
建立了化妆品中维生素C及其3种衍生物(抗坏血酸葡糖苷(AA-2G)、抗坏血酸磷酸酯镁(AA-2P)、抗坏血酸乙基醚(Only VCE))的高效液相色谱分析方法。化妆水、水乳液等含油脂较少的样品先采用30 mL 0.02 mol/L磷酸二氢钾溶液(pH 3.0)直接提取,然后定容至50 mL;面膏等含油脂较高及凝胶类、啫喱类的样品先加入1.0 mL二氯甲烷分散均匀后再加25 mL 0.02 mol/L磷酸二氢钾溶液(pH 3.0)提取。提取液在12000 r/min下离心后用0.22 μm滤膜过滤。样品分析采用YMC-Triart C18色谱柱,以0.02 mol/L磷酸二氢钾溶液(pH 3.0)和甲醇溶液为流动相,梯度洗脱,流速为1.0 mL/min,柱温为25 ℃,使用二极管阵列检测器(DAD)检测,检测波长为250 nm,外标法定量。结果显示:4种化合物在其线性范围内线性关系良好,相关系数(r2)均大于0.9999;方法的定量限(以信噪比为10计)为0.04~0.08 g/kg;添加水平为0.25~5.0 g/kg时的回收率为95.6%~101.0%,相对标准偏差为0.62%~3.0%。该方法前处理简单、回收率高、精密度好,适用于化妆品中维生素C及其衍生物的测定。  相似文献   

14.
李方楼  赵欣捷  许国旺 《分析化学》2006,34(10):1366-1370
合成了硅胶基硝化苯硼酸亲和色谱材料,首先对间氨基苯硼酸进行硝基化,制得3-氨基-4-硝基苯硼酸功能基团,通过γ-缩水甘油醚氧丙基三甲氧基硅烷把功能基团键合到硅胶基体上,在20.7MPa压力下装成亲和色谱预柱(35mm×4.6mmi.d.)。用该预柱通过六通阀后接ODS分析柱(250mm×4.6mmi.d.),构成中心切割二维HPLC。该系统能对含有顺二羟基结构的化合物进行在线富集,实现生物复杂样品直接进样分离分析。使用该系统对尿中多种修饰核苷进行了分离分析,以pH值7.95的0.25mol/LNH4Ac碱性缓冲液把实际尿样(100μL)中核苷保留在预柱上,生物大分子无保留通过,再切换六通阀,以pH4.50的25mmol/LKH2PO4酸性洗脱液把保留在预柱上的核苷洗脱,进样到下一级ODS分析柱柱头上聚焦,然后用梯度洗脱法(pH4.50的25mmol/LKH2PO4缓冲液与体积比60∶40的甲醇-水梯度混合构成洗脱液)完成核苷在ODS分析柱上的分离(紫外检测260nm),11种目标核苷的分离分析取得了良好的定性定量结果。  相似文献   

15.
Abstract

A simple HPLC method with minimal sample preparation and good reproducibility for the determination of trazodone in serum is described. Basified serum samples were extracted using ethyl acetate containing diazepam as the internal standard (IS). Chromatography was performed on a cyanopropylsilane column with 15 μL sample injection. The mobile phase consisted of 0.02 M ammonium phosphate, pH 7.5 : acetonitrile (70:30 v/v). The eluent was monitored at 220 nm. The serum standard curve was linear from 10.0 to 8000.0 ng/mL serum. The overall within-run quality control CV was 6.3% for five concentrations (20.0, 40.0, 100.0, 250.0 and 1000.0 ng/mL) and the overall recovery from serum was 85.4%. This method has been applied to the analysis of human serum samples.  相似文献   

16.
应用毛细管区带电泳法测定分别以冬虫夏草菌丝体粉和鹿茸血为主要原料制品中的多种核苷和碱基成分。对实验条件进行了优化,结果表明,以20mmol/L硼砂-15mmol/Lβ-环糊精为缓冲溶液(pH=9.4),分离电压22kV,检测波长254nm,电动进样为10kV、5s时,在10min内同时分离测定了虫草素、腺嘌呤、鸟嘌呤、尿嘧啶、腺苷、次黄嘌呤、尿苷、鸟苷和肌苷。各组分在0.2~200μg/mL范围内呈线性关系,检出限的范围是0.07~1.67μg/mL。5个批次的冬虫夏草菌丝粉保健品中腺嘌呤、尿嘧啶、腺苷、鸟苷、尿苷5组分的定量结果分别在0.15~0.19mg/g、0.72~0.92mg/g、1.44~1.59mg/g、1.51~2.32mg/g和1.77~2.56mg/g范围内,加标回收率的范围是82.83%~109.21%;2个批次的鹿茸血保健品中次黄嘌呤、尿苷的定量结果在36.55~49.97μg/mL和86.08~108.97μg/mL范围内,加标回收率的范围分别是89.68%~96.79%和99.05%~102.81%。  相似文献   

17.
Adriamycin, adriamycinol, adriamycinone and duanorubicin were simultaneously determined by the development of an on-line plasma clean-up system. A short protein-coated Lichrosorb, RP-8, RP-2, CN and muBondapak phenyl as well as ODS silica have been examined for their performance as pre-columns. The drugs and metabolites were separated from weakly retained plasma components through two steps; phosphate buffer saline, pH 7.4 and 15% acetonitrile in 0.1 M sodium dihydrogen phosphate, pH 3. The chromatographic conditions were: ODS/TM column, flow rate 1 ml/min, 35% acctonitrile in 0.1 M sodium dihydrogen phosphate (pH 3) containing 0.3% heptafluorobutyric acid as mobile phase. The detection was carried out using fluorescence monitor operated at an emission 555 nm and excitation 460 nm. Good resolution was obtained within 13 min. This method is reproducible for analysis of drugs and metabolites (99.3-100.1%, CV < 2%) in plasma.  相似文献   

18.
Ion chromatography on a 4.0-mm-long (3.0 mm ID) ion exchange column is presented. Using a 10 mM phosphate buffer (pH 2.22) the separation of up to six UV-absorbing anions was obtained using the microcolumn, containing 5 microm RP support (Phenomenex Gemini) coated with the zwitterionic surfactant, (N-dodecyl-N,N-dimethylammonio) undecanoate. The short analytical column facilitated the application of a flow gradient programme over the flow range 0.3-5 mL/min resulting in optimum resolution of nitrite, nitrate, benzoate, iodide, thiocyanate and trichloroacetate in less than 10 min. The effect of both eluent concentration and pH on the retention of six selected anions was investigated, showing a strong pH capacity dependence. The microcolumn was found to exhibit no selectivity towards chloride and so was well suited to the analysis of saline samples. To illustrate this, the rapid analysis of a concentrated iodized table salt sample (20 g/L) was carried out. Following standard addition, a concentration of 3.55 +/- 0.05 microg iodide/g and 1.05 +/- 0.02 microg iodate/g in the solid salt sample was determined.  相似文献   

19.
建立了动物肝脏组织中维吉尼亚霉素M1残留的液相色谱-电喷雾电离三重四级杆质谱(LC-ESI-MS/MS)的测定方法。样品经0.2 mol/L NH4H2PO4和乙酸乙酯提取,分散型固相萃取PSA填料净化,采用正离子扫描多反应监测(MRM)模式下液质联用仪进行定性和定量分析。该方法省去耗时的固相萃取过程,回收率在67.2%~90.3%之间,RSD<10.0%;检测限为0.5μg/kg,定量限为1.0μg/kg。  相似文献   

20.
We have revisited the direct analysis experiments reported by Tomer and co-workers in the MALDI-TOFMS analysis of phosphopeptide-loaded immobilized metal ion affinity chromatography (IMAC) beads (Zhou, W.; Merrick, B. A.; Khaledi, M. G.; Tomer, K. B. J. Am. Soc. Mass Spectrom. 2000, 11, 273-282). The results described herein provide no evidence to support a laser-induced direct desorption of phosphopeptides chelated on IMAC beads. However, we have established that solubilization of mono-phosphopeptides from their immobilized Fe3+-NTA chelates does occur effectively in solutions containing certain MALDI matrices. Particularly effective is 2,5-dihydroxybenzoic acid (2,5-DHB), which apparently forms a stronger chelation complex with Fe3+-NTA than mono-phosphopeptides. With regard to the disparity observed between the low pH value of MALDI matrices (saturated 2,5-DHB(aq) approximately pH 2) and the high pH values of conventional IMAC eluents (typically above pH 7), we have also investigated the influence of eluent pH on the recovery of phosphopeptides from IMAC media. Finally, we have confirmed the importance of employing ammonium dihydrogen phosphate as buffer to achieve effective liberation of mono- and all poly-phosphopeptide species from Fe3+-NTA IMAC resin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号